• 제목/요약/키워드: biological drinking water treatment

검색결과 76건 처리시간 0.032초

활성탄 재생이 자연유기물질의 흡착에 미치는 영향 (Effect of Reactivation of Activated Carbon on Adsorption of Natural Organic Matter)

  • 홍성호;최주솔
    • 상하수도학회지
    • /
    • 제21권3호
    • /
    • pp.323-329
    • /
    • 2007
  • There is no certain definition about advanced drinking water treatment but it is generally known as activated carbon process, membrane process or ozone process which can remove non-conventional pollutants such as taste and odor compounds, and micro-pollutants. There are more than 20 processes related to activated carbon as adsorber or biological activated carbon in Korea. The saturated carbon by pollutants can be reused by reactivation. However, the effect of reactivation on activated carbon is not well-understood in terms of changing physical properties of carbon to adsorption capacity of natural organic matter (NOM). In this study, the effects of reactivation on physical properties of activated carbon were investigated by isotherm and breakthrough of NOM. Ash content was increased from 8% to 13.3%. Iodine number is commonly used as an indicator for performance of reactivation. The iodine number was decreased about 20% after reactivating twice. The degree of reactivation can be evaluated by not only iodine number but also apparent density.

하수 유래 미량오염물질 현황과 관리 방안 고찰 (A review on status of organic micropollutants from sewage effluent and their management strategies)

  • 최상기;이웅배;김영모;홍석원;손희종;이윤호
    • 상하수도학회지
    • /
    • 제35권3호
    • /
    • pp.205-225
    • /
    • 2021
  • Due to the large-scale production and use of synthetic chemicals in industralized countries, various chemicals are found in the aquatic environment, which are often termed as micropollutants. Effluents of municipal wastewater treatment plants (WWTPs) have been identified as one of the major sources of these micropollutants. In this article, the current status of occurrence and removal of micropollutants in WWTPs and their management policies and options in domestic and foregin countries were critically reviewed. A large number of pharmaceuticals, personal care products, and industrial chemicals are found in WWTPs' influent, and are only partially removed by current biological wastewater treatment processes. As a result, some micropollutants are present in WWTPs' effluents, which can negatively affect receiving water quality or drinking water source. To better understand and assess the potential risk of micropollutants, a systematic monitoring framework including advanced analytical tools such as high resolution mass spectrometry and bioanalytical methods is needed. Some Western European countries are taking proactive approach to controlling the micropollutants by upgrading WWTP with enahnced effluent treatment processes. While this enahnced WWTP effluent treatment appears to be a viable option for controlling micropollutant, its implementation requires careful consideration of the technical, economical, political, and cultural issues of all stakeholders.

덕산(德山) 정수장(淨水場)에서의 BAC Pilot plant에 관한 연구(硏究) (A study on the BAC pilot plant in the Duk-san water works)

  • 이상봉;김동윤;임정아;이원권
    • 상하수도학회지
    • /
    • 제9권2호
    • /
    • pp.97-107
    • /
    • 1995
  • Today a conventional water treatment system has many problems. The ozone/GAC process, sometimes termed Biological Activated Carbon(BAC), appeared to be effective for the removal of soluble organic matters in the drinking water. The water quality of Nak-dong river in Pusan, generally shows BDOC 30-40% and NBDOC 60-70%. The pilot plant installed at the Duk-san water works that was been largest treatability(1,650,000ton/day) in Pusan. A experimental water in the pilot plant made use of the water after sand-filteration. Following results are drawn from this study. Initial adsorption velocity($DOC/DOC_o/T$) in the pure adsorption of GAG had a 0.0225, it's velocity changed to 0.006 after ozone added and the optimum ozone dose ranged of $1.4-2.0mgO_3/L$. A experimental water in the pilot plant composed with humic material(78%). Humic material composed with humic acid(20%) and fulvic acid(56%), and it's rate changed to 18 and 50% respectively after ozone added. DOC constantly decreased in the EBCTs and removal efficieny in the 15min of EBCT was 45-50%. It showed the largest removal rate of BDOC in the EBCT 5 and among the season, characteristics of removal varied. The HPC distributed over $10^6-10^7CFU/cm^3$ in the bed depth and among the season, distribution of HPC were differential.

  • PDF

음용수 중 변이원성 물질(MX)에 관한 연구 (The study of analysis of mutagen in drinking water)

  • 유은아;원정인
    • 분석과학
    • /
    • 제19권4호
    • /
    • pp.290-300
    • /
    • 2006
  • 세계적으로 음용수 공급을 위한 정수 공정에는 여러 가지 방법이 쓰이고 있다. 그 중 염소는 값이 싸고 비교적 사용하기 쉬우며 미생물 제거 효과가 좋아 가장 많이 사용되는 소독제이다. 그러나 소독과정 중에 독성을 가지는 소독부산물을 생성시키는 문제가 있다. 대표적인 소독부산물에는 트리할로메탄같은 휘발성 물질과 유기염소산같은 비휘발성 물질이 있고, 최근 새로이 3-chloro-4-dichloromethyl-5-hydroxy-2(5H)-furanone (MX)라는 물질이 대두되고 있다. MX는 음용수 중 총 변이원성의 20-50%에 해당하는 강력한 변이원성을 가지는 물질이다. 이에 WHO에서는 MX를 유해물질로 선정하였으나 분석적 어려움과 독성 자료의 부족으로 인해 아직 정확한 기준치가 설정되지는 않았다. MX는 음용수 중에 21.9-30.3 ng/L 수준의 미량이 존재하였으므로 좀 더 효율적인 분석방법이 요구된다. 따라서 본 연구에서는 전처리 방법의 개선을 위해 액체-액체 추출방법과 고체상 추출방법을 사용하여 그 추출효율이 더 좋은, 고체상 추출방법을 채택하였다. 이미 여러 국가에서 MX의 분포를 조사한 바 있으나 국내에서는 MX의 분포 조사가 미흡한 실정이다. 따라서 본 연구에서는 국내의 각 정수장별 MX 함량과 수계별 MX 함량을 조사하여 국내의 MX 분포 실태를 파악하고자 하였다. MX의 생성패턴을 알고자 염소투입량, 정수장으로부터의 거리, 계절 수온 및 여러 수질조건에 따라 MX생성과의 상관관계를 확인해 본 결과 MX의 생성은 염소투입량과 계절, 수온의 영향을 받는 것으로 나타났다. 또한 MX의 최적 소독방법을 마련하기 위한 기초 연구로서 오존이나 입상활성탄(GAC)을 사용하는 고도처리수에서의 MX 함량을 측정하였다. 본 연구 결과 MX의 생성은 염소 투입량과 계절, 수온의 영향을 받는 것으로 나타났고, 오존 처리한 고도처리수에서의 MX 생성이 최소화되는 것을 확인하였다.

Use of biofilter as pre-treatment of polluted river water for drinking water supply

  • Suprihatin, Suprihatin;Cahyaputri, Bunga;Romli, Muhammad;Yani, Mohamad
    • Environmental Engineering Research
    • /
    • 제22권2호
    • /
    • pp.203-209
    • /
    • 2017
  • Innovations in the biofiltration process can provide effective solutions to overcome crucial water pollution problems. The elimination of pollutants is a result of the combined effects of biological oxidation, adsorption and filtration processes. This research aims to evaluate the performance of quartz sand biofiltration for removing total suspended solids, turbidity, color, organic matter, and ammonium from polluted river water and develop an empirical model for designing quartz sand biofilters for the treatment of polluted river water. Experiments were conducted using two biofilter units filled with quartz sand as filter media. A set of experiments were performed to evaluate the effect of hydraulic retention time on biofilter performance in removing water contaminants. The kinetics of organic matter removal were also determined to describe the performance of the biofilter. The results show that biofiltration can significantly remove river water pollutants. Removal efficiency depends on the applied hydraulic retention time. At a hydraulic retention time of two hours, removal efficiencies of total organics, ammonium and total suspended solids were up to 78%, 82%, and 91%, respectively. A model for designing quartz sand biofiltration has been developed from the experimental data.

BAC Pilot Plant 를 이용한 겨울철 암모니아성 질소 제거 및 THMs 변화 (Removal of Ammonia Nitrogen and Reduction of THMs in Low Temperature by BAC Pilot Plant)

  • 강은조;서영진;이원권;전병희;이지형;윤정효;김동윤
    • 상하수도학회지
    • /
    • 제9권4호
    • /
    • pp.107-114
    • /
    • 1995
  • The raw drinking water quality is getting worse because of the winter drought and the conventional treatment system is'nt suitable to obtain the satisfied quality of water. So, the advanced water system, BAC(Biological Activated Carbon) process is said to be effective to remove dissolved organics and ammonia nitrogen. In our study, the BAC pilot plant using Nak-dong river water is tested in low temperature. Following results are found from the study. The ammonia nitrogen removal rate of BAC system using wood-based carbon (PICABIOL) was 99% in $6^{\circ}C$ temperature. Chlorine dosage in wood-based BAC effluent was reduced to 67% of that in sand filtered wate. It resulted from the removal of ammonia nitrogen. Also, THM formed by chlorine addition in wood-based BAC effluent was decreased to 65% of that in sand filtered water. In the case of dual-filter, the removal efficiency of ammonia nitrogen was increased 30% more than in conventional sand filter. According to this result, the ammonia nitrogen load to BAC system could be lessened by the use of dual-filter.

  • PDF

생물활성탄처리에서 제거된 유기물 특성 (Characterization of Organic Matters Removed by Biological Activated Carbon)

  • 김우항;오카다미츠마사
    • 한국환경과학회지
    • /
    • 제16권6호
    • /
    • pp.671-675
    • /
    • 2007
  • The objective of this study was to clarify the characteristics of the removed micropollutant since the breakthrough of adsorption ability was occurred in biological activated carbon(BAC) process. The removal efficiency of DOC (Dissolved Organic Carbon) was 36 % in the breakthrough of BAC occurred by NOM (Natural Organic Matter). The most of removal DOC was found out the adsorbable and biodegradable DOC (A&BDOC). But it was not clear to remove by any mechanism because A&BDOC have simultaneously the adsorption of activated carbon and biodegradation by microorganism in BAC. The removal of bromophenol was examined with BAC and rapid sand filter, for investigation of DOC removal mechanism in the breakthrough of BAC. In this experiment, BAC filter has been operated for 20 months for the treatment of reservoir water. The BAC filter was already exhausted by NOM. Bromophenol, adsorbable and refractory matter, was completely removed by BAC filter. Therefore, it might be removed by the adsorption in BAC. Adsorption isotherms of bromophenol were compared to two BACs which was preloaded with 500 daltons and 3,000 daltons of NOM. BAC preloaded with 3,000 daltons of NOM was not decreased to the adsorbability of bromophenol but BAC preloaded with 500 daltons of NOM was greatly decreased to it. These result indicated that NOM of low molecular weight can be removed by adsorption after a long period of operation and the breakthrough by NOM in BAC. Therefore, micropollutants might be removed through adsorption by saturated BAC.

정수처리에서 생물활성탄의 전처리로서 고급산화처리법의 평가 (Evaluation of Advanced Oxidation Process(AOP) as a Pretreatment Process of Biological Activated Carbon in Drinking Water Treatment)

  • 김우항
    • 한국환경과학회지
    • /
    • 제8권6호
    • /
    • pp.725-730
    • /
    • 1999
  • The advanced oxidation process (AOP) using ozone combined with hydrogen peroxide and ultraviolet treatment were evaluated for biodegradable dissolved organic carbon (EDOC) formation and dissolved organic carbon (DOC) removal. Oxidation treatment were conducted alone or combination with ozone, hydrogen peroxide and ultraviolet processes. Ozone dosage of ozone process was varied from $0.5mg/l{\ell}\cdot}min$ to $5mg/{\ell}{\cdot}min$. Ozone/hydrogen peroxide process was done using $20mg/{\ell}{\cdot}min$ of hydrogen peroxide concentration. Ozone/ultraviolet process was irradiated with $12mW/cm^2$ of density and 254nm. Ozone dosage was varied from $0.5mg/{\ell}{\cdot}min$ to $5mg/{\ell}{\cdot}min$ at the ozone/hydrogen peroxide and ozone/ultraviolet processes too. Contact time of all the process was 20 minutes. Oxidation treatment were performed on microfiltration effluent samples. BDOC formation was reached to an optimum at ozone dosage of $1.5mg/{\ell}{\cdot}min$ in the ozone/hydrogen peroxide process and $1mg/{\ell}{\cdot}min$ in ozone/ultraviolet process, after which BDOC formation was decreased at higher ozone dosages. But BDOC formation was increased with ozone dosages increasing in ozone process. The efficiency of DOC removal was higher AOPs than ozone process. Ozone/ultraviolet proces was the highest for DOC removal efficiency in each process. THMFP. removal efficiency by ozone/ultraviolet process was higher than that by each of ozone process and ozone/hydrogen peroxide process.

  • PDF

한강수계 고도정수처리 공정에서의 유기물과 맛·냄새의 제거특성 (Removal Characteristics of Natural Organic Matter and Taste and Odor by Advanced Water Treatment Process around the Han River Water Supply System)

  • 임재림;이경혁;김성수;채선하
    • 상하수도학회지
    • /
    • 제21권1호
    • /
    • pp.13-25
    • /
    • 2007
  • The water treatment plants in Seoul Metropolitan Area, which are under Korea Water Resources Corporation(KOWACO)'s management, take water from Paldang Reservoir in Han River System for drinking water supply. There are taste and odor (T&O) problems in the finished water because the conventional treatment processes do not effectively remove the T&O compounds. As part of countermeasures for taste and odor control, KOWACO is planning to introduce advanced water treatment process such as ozone and GAC in near future. This study evaluated the removal characteristics of T&O and dissolved organic matter (DOM) to find design and operation parameters of advanced water treatment processes in a pilot-scale treatment plant. The GAC adsorption capacity for DOC in the two GAC system (GAC and $O_3$-GAC) at an EBCT of 14min was mostly exhausted after 9months. The differency of the removal efficiency of DOC between $O_3$-GAC and GAC increased with increasing operation time because the bioactivity in $O_3$-GAC process was enhanced by post-ozone process. Removal by conventional treatment was unable to reach the target TON(threshold odor number) of 3 but GAC systems at an EBCT(empty bed contact time) of 14 min were able to archive the target with few exception. During the high T&O episodes, PAC as a pretreatment together with GAC could be useful option for T&O control. However, substantial TON removal continued for more than two year (> 90,000 bed volumes). At the spiking of less concentration 26 to 61 ng/L in the influent of GAC systems, GAC absorber and $O_3$-GAC processes could meet the treatment target. The better spike control after 12 and 19 months of operation compared to that after 7 months of operation is a strong indication of biological control. The results presented in this study had shown that $O_3$-GAC process was found to be more effective for T&O control than GAC process. And the main removal mechanism in GAC systems were adsorption capacity and biodegradation.

단일개체군 생물막 반응기를 이용한 페놀폐수의 효율적 처리

  • 박근태;이준훈;이희정;최정순;손홍주;이상준
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 추계학술발표대회 및 bio-venture fair
    • /
    • pp.520-523
    • /
    • 2000
  • Phenol and other phenolic compounds are common constituents of aqueous effluents from processes such as polymeric resin production, oil refining and cokeing plants. Phenol is a both toxic and lethal of fish at relatively low concentrations e.g. 5-25 mg/L and imparts objectionable tastes to drinking water at far lower concentration. Therefore, the treatment of phenol effluent is important. Among the various techniques of phenol wastewater treatment, microbial teratment is a popular process. The breakdown of phenols by microorganisms has recived considerable attention, because of its biochemical interest and its industrial importance in effluent treatment. This research was performed to investigate the dynamics of microbial community, biofilm growth and the comparison of phenol removal efficiency by RBC (Rotating Biological Contactor) using Rhodococcus sp. EL-GT The experiment was carried out at rotating speed of 10ppm and hydraulic retention time of 7 hours. As time passed, phenol removal efficiency was gained highly. The RBC using Rhodococcus sp. EL-GT completely degraded 15 mM.

  • PDF