• 제목/요약/키워드: biofilm process

검색결과 158건 처리시간 0.029초

Denitrifying PAO와 SBBR-MSBR을 이용한 생물학적영양소제거공정에서 탄소원 절약에 대한 연구 (Evaluation of COD Utilization for Biological Nutrient Removal with dPAO in SBBR-MSBR System)

  • 이한샘;한종훈;윤주환
    • 한국물환경학회지
    • /
    • 제27권5호
    • /
    • pp.646-653
    • /
    • 2011
  • The combined system of sequencing batch biofilm reactor (SBBR) and membrane SBR (MSBR) was operated with sewage to evaluate the COD utilization for biological nutrient removal (BNR). The SBBR was operated for nitrification reactor, while denitrifying PAO (dPAO) was cultivated in MSBR with anaerobic-anoxic operation. In the SBBR and MSBR system, the enhanced biological phosphorus removal (EBPR) was successfully achieved with higher N removal. The COD utilization in combined SBBR-MSBR system was significantly reduced compared to ordinary BNR (up to 3.1 g SCOD/g (N+P) and 1.6 g SCOD/g (N+P) with different C/N/P ratio). The results suggest that a dPAO process could effectively reduce carbon energy (=COD) requirement. The combination of oxic-SBBR and anaerobic-anoxic MSBR for dPAO utilization could be an attractive alternative to upgrade the process performance in weak sewage.

고정생물막을 이용한 기존 하수처리장의 생물학적 영양염 제커 신공정개발 (Development of New BNR Process Using Fixed-Biofilm to Retrofit the Existing Sewage Treatment Plant)

  • 김미화;이지형;전양근;박태주
    • 대한환경공학회지
    • /
    • 제22권6호
    • /
    • pp.1093-1101
    • /
    • 2000
  • 본연구의 목적은 국내의 기존 하 폐수처리장에 생물막을 적용하여 BNR공정으로 전환 및 개조하거나 생물막 공법을 적용한 BNR공정을 3차 처리로 적용할 수 있는 새로운 공정을 개발하는 데 있다. 우리 나라 하수의 $SCOD_{cr}/T-N(NH_4{^+}-N+NOx-N) $ 비는 다른 나라에 비하여 상대적으로 낮기 때문에 완전한 탈질화를 얻기 위해서는 외부탄소원을 반드시 공급해야만 한다. 본 연구에서의 $SCOD_{cr}/NH_4{^+}-N$비는 2.49이었으며, 실험기간 동안 유입수 $NH_4{^+}-N$농도는 25에서 37 mg/L로 변화되었다. 하수처리시 질소제거능을 향상시키기 위하여 R-1(무산소/중간침전조/호기성/무산소/호기성)과 R-2(호기성/중간침전조/무산소/무산소/호기성)의 생물막을 이용하는 두 공정을 적용하였다. 외부탄소원을 투여하지 않은 조건에서 $NH_4{^+}-N$와 T-N의 유출수질과 제거효율은 R-1공정이 R-2공정에 비하여 하수로부터 질소제거에 보다 적절한 것으로 평가되었다. 무산소 반응조의 $SCOD_{cr}/NOx-N$비와 T-N제거효율을 고려하였을 때, R-1공정이 원하수내 유기물질의 분배에 있어서 더 효과적인 것으로 사료되었다. R-1 공정과 R-2공정에서 1 g의 $NH_4{^+}-N$를 제거하는데 요구되는 알칼리도는 R-1과 R-2 각각 5.18과 5.76(g $CaCO_3/g$ removed $NH_4{^+}-N$)이었으며, 이는 활성슬러지 BNR공정에 비하여 낮았다.

  • PDF

회전원판접촉법(回轉圓板接觸法)에 의한 폐수처리(廢水處理)의 모형(模型)에 관한 연구(研究) (Models of Wastewater Treatment by Rotating Discs)

  • 정태학;박중현
    • 대한토목학회논문집
    • /
    • 제2권2호
    • /
    • pp.39-46
    • /
    • 1982
  • 회전원판접촉법(回轉圓板接觸法)에 의한 폐수처리(廢水處理)의 이해(理解)를 증진(增進)시키고 여러가지 조건(條件)의 변화(變化)에 따라 달라지는 처리효율(處理效率)을 산정(算定)하기 위하여 모형(模型)을 개발(開發)하고 Simulation을 통하여 정상상태(定常狀態)와 비정상상태(非定常狀態)에서의 모형(模型)을 분석(分析)하였다. 회전원판(回轉圓板)에 의한 기질제거모형(基質除去模型)은 용액(溶液)으로부터 미생물막내부(微生物膜內部)로의 기질전달(基質傳達)과 미생물(微生物)에 의한 기질(基質)의 분해(分解)에 의해 처리(處理)가 이루어진다고 가정(假定)하고 정립(定立)되었고 모형(模型)은 여러개의 요소(要素)로 나뉘어진 액체막(液體膜)과 미생물막(微生物膜), 그리고 용액중(溶液中)의 기질농도(基質濃度)에 관한 일련의 물질수지식(物質收支式)으로 구성(構成)된다. 정상상태(定常狀態)에서 처리효율(處理效率)은 기질(基質)의 확산계수(擴散係數)와 미생물(微生物)의 최대기질분해율(最大基質分解率)에 의해 좌우(左右)되고 확산(擴散)에 의한 영향은 용액중(溶液中)의 기질농도(基質濃度)가 낮고 최대기질분해율(最大基質分解率)이 높을 경우 현저하게 나타난다. 기질제거효율(基質除去效率)은 미생물막(微生物膜)의 두께가 얇을 때는 거의 두께에 비례(比例)하여 증가(增加)하나 두께의 증가(增加)에 따라 효율증가(效率增加)는 둔화(鈍化)되고 한계(限界)두께에 이르면 기질(基質)의 침투(浸透)가 불충분(不充分)하여 효율(效率)은 일정(一定)해진다. 비정상상태(非定常狀態)에서 유출수(流出水)의 수질(水質)은 반응조(反應槽)의 체적(體積)에 의해 영향을 받는다. 반응조(反應槽)의 체적증가(體積增加)는 첨두부하(尖頭負荷)에 대하여 첨두농도(尖頭濃度)를 낮게하는 완충효과(緩衝效果)를 나타내기 때문에 반응조(反應槽)는 균등조(均等槽)의 역할을 한다 할 수 있다.

  • PDF

생물막 반응조에서 아질산염 축적에 미치는 운전인자 영향과 하수슬러지 가용화에 의한 탈질반응의 외부탄소원 공급에 관한 연구 (Influence of Operating Parameters on Nitrite Accumulation in a Biofilm Reactor and Supplement of External Carbon Source for Denitrification by Sewage Sludge Solubilization)

  • 안혜민;이대성
    • 대한환경공학회지
    • /
    • 제35권1호
    • /
    • pp.57-63
    • /
    • 2013
  • 고농도 질소를 함유한 하 폐수를 아질산염 축적 경로를 통하여 처리하고자 생물막공정과 연속혼합반응조의 탈질공정을 결합하여 운전하였다. 생물막 반응조의 폴리에틸렌 담체 표면에 아질산염 산화균에 비해서 암모늄 산화균의 성장을 촉진하여 아질산염을 선택적으로 축적하고자 반응조 온도를 $35^{\circ}C$로 유지하면서 석달 이상 장기간 운전하였음에도 불구하고 유입수 암모늄(500 mg-N/L)의 일부만 아질산염(240 mg-N/L)으로 전환되었다. 하지만 pH를 7.5에서 8.0으로 증가시켰을 때, 아질산염 산화균들이 높은 암모니아 농도에 성장 저해를 받아 생물막 공정에서 아질산염 축적을 성공적으로 이끌어낼 수 있었다. 생물막 공정의 수리학적 체류시간을 12시간으로 운전하였을 때, 반응조의 성능이 급격하게 저하되어 유입수의 암모늄이 완전히 산화되지 않았다. 하수슬러지의 생분해성을 높이기 위해서 다양한 가용화 기술을 적용한 결과, 알칼리와 초음파 처리를 순차적으로 병합하였을 때, 가장 높은 가용화율(58%)을 얻을 수 있었으며, 이를 탈질반응조의 외부탄소으로 사용하였다. FISH 분석결과로부터 담체표면에 암모늄 산화균인 Nitrosomonas와 Nitrospirar계열의 미생물들이 우점종이었으며 일부 아질산염 산화균인 Nitrobacter 계열의 미생물도 소량이지만 관찰되었다.

연속순환 생물막 공정을 이용한 돈사 폐수 처리 (Swine Wastewater Treatment Using Continuos Circulation Biofilm Process)

  • 고병대;라창식
    • Journal of Animal Science and Technology
    • /
    • 제49권2호
    • /
    • pp.279-286
    • /
    • 2007
  • 반응물을 연속적으로 내부 순환시키는 생물막 연속회분식모래여과 공정을 고안하고 외부 탄소원이 전혀 사용되지 않는 조건하에서의 돈사폐수 처리특성을 평가하였다. 수직형과 경사형 모래여과조에서의 NOx-N 부하량에 따른 탈질율은 각각 19%와 3.8%로 수직형에서 5배 정도 높은 효율을 보임에 따라 수직형태의 모래여과조를 생물막 연속회분식 공정과 연계하여 운전하였다. 처리공정을 HRT 15일, 내부순환율 105L/hr.m3, 평균 암모니아성 질소 부하량 54g/m3.d 조건에서 운전하였을 때 STOC, NH4- N, TN의 처리효율은 각각 75%, 97%, 85%이었다. 생물막 연속회분식 반응조와 모래여과조간의 내부순환으로 TN의 제거효율이 약 14%증진되는 것으로 나타났으며 얻어진 질소제거효율 증진은 주로 모래여과조에서의 탈질에 의한 것으로 밝혀졌다. 또한 용해성 인의 경우 내부순환이 수행되지 않았을 시에는 유출수내 농도가 오히려 증가하였으나 내부순환시에는 약 57% 정도가 제거되는 것으로 나타남에 따라 반응물의 내부순환이 용해성 인의 제거효율 증진에도 기여함을 알 수 있었다. 시스템에서의 질소제거 양상을 분석해본 결과 최종 유출수내의 NH4-N은 부하량 60g/m3.d 수준에서 약 20mg/L 이하로 비교적 일정하였고 부하량이 100g/m3.d. 이상의 수준으로 상승함에도 80% 이상의 질소 제거효율을 보였다. 그러나 부하량 100g/m3.d 수준 이상에서부터 처리효율이 감소하는 것으로 나타나 외부탄소원이 전혀 사용되지 않는 운전조건에서의 질소의 적정 부하량은 약 100g/m3.d 정도인 것으로 판단되었다.

Optimization of membrane fouling process for mustard tuber wastewater treatment in an anoxic-oxic biofilm-membrane bioreactor

  • Chai, Hongxiang;Li, Liang;Wei, Yinghua;Zhou, Jian;Kang, Wei;Shao, Zhiyu;He, Qiang
    • Environmental Engineering Research
    • /
    • 제21권2호
    • /
    • pp.196-202
    • /
    • 2016
  • Membrane bioreactor (MBR) technology has previously been used by water industry to treat high salinity wastewater. In this study, an anoxic-oxic biofilm-membrane bioreactor (AOB-MBR) system has been developed to treat mustard tuber wastewater of 10% salinity (calculated as NaCl). To figure out the effects of operating conditions of the AOB-MBR on membrane fouling rate ($K_V$), response surface methodology was used to evaluate the interaction effect of the three key operational parameters, namely time interval for pump (t), aeration intensity ($U_{Gr}$) and transmembrane pressure (TMP). The optimal condition for lowest membrane fouling rate ($K_V$) was obtained: time interval was 4.0 min, aeration intensity was $14.6 m^3/(m^2{\cdot}h)$ and transmembrane pressure was 19.0 kPa. And under this condition, the treatment efficiency with different influent loads, i.e. 1.0, 1.9 and $3.3kgCODm^{-3}d^{-1}$ was researched. When the reactor influent load was less than $1.9kgCODm^{-3}d^{-1}$, the effluent could meet the third discharge standard of "Integrated Wastewater Discharge Standard". This study suggests that the model fitted by response surface methodology can predict accurately membrane fouling rate within the specified design space. And it is feasible to apply the AOB-MBR in the pickled mustard tuber factory, achieving satisfying effluent quality.

유체 흐름 안에서 두 종의 생물막 성장 시뮬레이션 모델 (Simulation Model of Dual-Species Biofilm Growth in Hydrodynamic Flow)

  • 전원주;이상희
    • 한국시뮬레이션학회논문지
    • /
    • 제20권1호
    • /
    • pp.97-105
    • /
    • 2011
  • 하천에서, 생물막은 녹갈색의 얇은 막의 형태로 돌, 식물, 그리고 기타 구조물의 표면에 부착되어 있다. 생물막은 주로 영양물의 순환, 수질정화, 바닥 침전물 제거, 그리고 먹이사슬내의 에너지 흐름에 매우 중요한 역할을 한다. 본 연구에서, 우리는 유체 흐름 안에서, 독소-생산 종과 독소-민감 종의 복합적 생물막을 전산 모사하는 모델을 개발하였다. 유체 흐름으로는 균일한 흐름과 불 균일한 흐름 두 가지를 고려하였다. 균일한 흐름은 확률 프로세스로 구현되었으며, 불 균일한 흐름은 나비어-스톡스 방정식으로 구현되었다. 모델에서, 독소-생산종과 독소-민감종 간의 상호작용을 고려하기 위해, 종 개체의 번식률과 사망률이 고려되어졌다. 우리는 서로 다른 두 유체 흐름 내에서 전산 모사 되어진 생물막의 구조적 형상에 대해서 간략히 논의 하였다.

Pilot 규모의 상향류식 충전탑 반응기를 이용한 생활오수의 유기물 및 질소, 인 처리에 관한 연구 (A Study on Removal of Organics, Nitrogen and Phoschorus of Domestic Wastewater in Pilot-Scale Upflow Packed Bed Column Reactor)

  • 선용호
    • KSBB Journal
    • /
    • 제22권4호
    • /
    • pp.191-196
    • /
    • 2007
  • 본 연구는 급속한 산업 발전으로 인해 일어난 많은 수질오염 문제 중 생활하수의 처리방법에 관심을 기울여 생물막 공법을 이용하였는데, 이는 소규모 오폐수 처리장치에서 운전과 유지가 간단하고 활성슬러지 공정보다 넓은 부지를 필요로 하지 않기 때문이다. 생물막 공법 중 생물여상법의 변법을 적용한 Pilot 규모의 상향류식 충전탑형 반응기로 내부의 담체로는 폐토기와 폐비닐을 넣어 혐기조와 호기조를 구성하였고, 생활 오수로는 식당 오수를 이용하여 Lab.-Scale 실험 후 Pilot-Scale로 Scale-up하여 100여일 간에 걸쳐 실험을 수행하였다. 실험은 연속 포기시 일정 HRT에서 유기물과 질소, 인 제거율을 살펴보았다. 실험결과 $BOD_5$와 SS의 평균 제거율은 각각 94.33%와 87.77%로 높은 제거율을 보였으나, $COD_{Cr}$은 81.46%로 목표 제거율 90% 이상에 미치지 못하였고, T-N과 T-P도 각각 71.92%와 21.10%로 예상보다 약간 낮았다. 특히 $COD_{Cr}$와 T-N의 제거율은 지난 Lab.-Scale 때보다 약 10% 정도의 감소를 하여 Pilot-scale에 내외적인 문제가 작용한 것으로 보였다.

상향류 활성탄 생물막 공정을 이용한 정체 수역 수질 개선 및 공정 내 미생물 군집 해석 (Water Quality Improvement of Stagnant Water using an Upflow Activated Carbon Biofilm Process and Microbial Community Analysis)

  • 오유미;이재호;박정진;최기충;박태주;이태호
    • 대한환경공학회지
    • /
    • 제32권1호
    • /
    • pp.23-32
    • /
    • 2010
  • 정체수역에서는 자연적 흐름의 차단으로 인해 자정능력이 떨어지며, 영양염류의 축적으로 인해 부영양화와 같은 문제점이 발생한다. 또한 비점오염물질의 유입은 정체수역 내 난분해성 물질을 증가시킨다. 본 연구에서는 정체수역의 수질개선을 위해 무산소조, 호기1조, 호기2조로 구성된 장치형 상향류 활성탄 생물막 반응기를 도입하여 정체수의 연속적 순환에 따른 오염물질 농도의 변화를 모니터링 하였다. 정체수역을 모사하기 위하여 $2m^3$의 저장탱크에 유원지의 호소수를 저장하였으며, 수질개선을 위한 최적 유입 유량을 산출하기 위하여 HRT가 6 hr, 4 hr, 2 hr 가 되도록 호소수의 유입 유량을 변화시켰다. 이 가운데 HRT 4 hr에서 SS, $BOD_5$, $COD_{Mn}$, $COD_{Cr}$, TN, TP의 제거 효율이 각각 69.8, 83.0, 91.3, 74.1, 74.7, 88.9%로 가장 좋은 수질 개선 효과를 얻을 수 있었다. 이에 HRT를 4 hr로 고정하고 골프장 연못수를 운전했을 때 SS, $BOD_5$, $COD_{Mn}$, $COD_{Cr}$ TN, TP의 제거 효율이 각각 78.5, 78.0, 80.2, 74.9, 55.6, 97.5% 달성되었다. 각 조건에서의 미생물 군집 변화를 PCR-DGGE를 사용하여 분석 결과, 유입수를 골프장 연못수로 교체함에 따라 미생물 군집에 변화가 나타났다. 또한 FISH에 의해 유입 유량 변화에 따른 질산화 미생물량의 변화를 관찰한 결과, HRT 4 hr의 조건에서 질산화 미생물이 가장 우점화됨을 알 수 있었다. 미생물량 및 INT-DHA를 이용한 미생물 활성도 실험 결과, HRT를 낮게 유지하였을 때에도 감소되지 않았다. 따라서 상향류 활성탄 생물막 공정을 정체 수역의 효과적인 수질 개선에 충분히 적용할 수 있을 것으로 기대한다.

폭기식 잠수여상을 이용한 고밀도 양식장의 순환수 처리 -1. 해수중의 암모니아 제거 특성- (The Recycling Water Treatment of High Density Fish Culture System Using the Aerated Submerged Filter -1. Ammonia Removal Characteristics in Sea Water-)

  • 이헌모;이재관;정병곤;양병수
    • 한국수산과학회지
    • /
    • 제26권5호
    • /
    • pp.502-509
    • /
    • 1993
  • Submerged filter process was used to evaluate the nitrifying efficiency of ammonia in the recycling water of marine aquatic culture system. The ammonia removal efficiency was achieved as high as $99\%$ at the hydraulic surface loading rate of up to $4.3{\ell}/m^2-day$. And the nitrite accumulation did not occur in the reactor even when the hydraulic surface loading rate of up to $36.8{\ell}/m^2day$ was applied. In the present study, the relationship between the effluent ammonia concentration and ammonia surface loading rate was formulated as an equation. The attachment rate of biofilm on the filter media at the ammonia surface loading rate of 62.3 and $311.7mg/m^2day$ was 15 and $55mg/m^2-day$, respectively, showing the linear relationship between the attachment rate and ammonia loading rates. Biofilm thickness and density of the filter media were found to be the function of the ammonia loading rate.

  • PDF