• 제목/요약/키워드: bioequivalence test

검색결과 200건 처리시간 0.024초

클래리스로마애신 정제의 생물학적 동등성 평가 (Bioequivalence of Two Clarithromycin Tablets)

  • 김종국;이사원;최하곤;고종호;이미경;김인숙
    • Biomolecules & Therapeutics
    • /
    • 제6권2호
    • /
    • pp.219-224
    • /
    • 1998
  • The bioequivalence of two clarithromvcin products was evaluated with 16 normal male volunteers (age 23-28 yr, body weight 57.5-75.517g) following single oral dose. Test product was ReYon Clarithromycin tablets (ReYon Pharm. Corp., Korea) and reference product was Klarici $d_{R}$ tablets (Abbott Korea). Both products contain 250 mg of clarithromucin. One tablet of the test or the reference product was administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). The determination of clarithromycin was accomplished using a modified agar well diffusion bioassay. As a result of the assay validation, the quantification of clarithromycin in human serum by this technique was possible down to 0.03$\mu$g/ml using 100$\mu$l of serum. The coefficient of variation (C.V.) was less than 10%. Average drug concentrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products P>0.05); the area under the curve to last sampling time (24 hr) (AU $Co_{24hr}$ (8.10$\pm$ 1.26 vs 8.22$\pm$ 1.627g . hr/ml), AUC from time zero to infinite (AU $Co_{\infty}$) (8.61 $\pm$ 1.28 vs 8.84$\pm$ 1.71 $\mu$g . hr/ml), maximum plasma concentration ( $C_{msx}$) (0.87$\pm$0.22 vs 0.88$\pm$0.19 $\mu$g/ml) and time to maximum plasma concentration ( $T_{max}$) (2.69 $\pm$0.48 vs 2.56$\pm$ 0.51 hr). The differences of mean AU $Co_{24h}$, $C_{msx}$ and $T_{msx}$ between the two products (1.44, 1.39, and 4.65%, respectively) were less than 20%. The power (1-$\beta$) and treatment difference ($\Delta$) for AU $Co_{24hr}$, and $C_{max}$ were more than 0.8 and less than 0.2, respectivly. Although the power for $T_{max}$ was under 0.8, $T_{max}$. of the two products was not significantly different each other (p>0.05). These results suggest that the bioavailability of ReYon Clarithromycin tablets is not significantly different from that of Klarici $d_{R}$ tablets. Therefore, two products are bioequivalent based on the current results. results.sults.sults.s.s.s.s.s.s.s.

  • PDF

LC/MS/MS를 이용한 가바펜틴 300 mg 캡슐의 성인 지원자에 대한 생물학적 동등성 및 약물동태 연구 (Bioequivalence and Pharmacokinetic study of Gabapentin 300mg Capsules using Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS) in Volunteers)

  • 정지훈;권준택;윤휘열;강원구;권광일
    • 한국임상약학회지
    • /
    • 제16권1호
    • /
    • pp.63-68
    • /
    • 2006
  • Gabapentin, 1-(aminomethyl-1-cyclohexyl)acetic acid, is anew antiepileptic drug related to ${\gamma}-aminobutyric$ acid(GABA) currently being introduced in therapy worldwide. The bioavailability and pharmacokinetics of gabapentin capsules were examined in 22 volunteers who received a single oral dose in the fasting state by randomized balanced $2{\times}2$ crossover design. After dosing, blood samples were collected for a period of 24 hours and analyzed by liquid chromatography-tandem mass spectrometry (LC/MS/MS). Time course of plasma gabapentin concentration was analyzed with non-compartmental and compartmental approaches. $WinNonlin^{(R)}$, the kinetic computer program, was used for compartmental analysis. One compartment model with first-order input, first-order output with no lag time and weighting by $1/(predieted\;y)^2$ was chosen as the most appropriate pharmacokinetic model for the volunteers. The major pharmacokinetic parameters $(AUC_{0-24hr},\;AUC_{inf},\;C_{max}\;and\;T_{max})$ and other parameters $(K_a,\;K_{el},\;V_d/F\;and\;Cl/F)$ of $Gapentin^{TM}$ (test drug) and $Neurontin^{TM}$ (reference drug) were estimated by non-compartmental analysis and compartmental analysis. The 90% confidence intervals of mean difference of logarithmic transformed $AUC_{0-24hr}\;and\;C_{max}$ were $log(0.9106){\sim}log(1.l254)\;and\;log(0.8521){\sim}log(1.0505)$, respectively. It shows that the bioavailability of the test drug is equivalent with that of the reference drug. There was no statistically significant difference between the two drugs in all pharmacokinetic parameters.

  • PDF

세파클러 250 mg 캅셀의 생물학적 동등성 (Bioequivalence of Cefaclor (250 mg) Capsule)

  • 윤민혁;김호순;최용포;권광일
    • 한국임상약학회지
    • /
    • 제12권2호
    • /
    • pp.71-75
    • /
    • 2002
  • This study was carried out to compare the bioavailability of $Ceclex^{(R)}$ (test drug, cefaclor 250 mg/capsule) with that of $Ceclor^{(R)}$ (reference drug) and to estimate the pharmacokinetic parameters of cefaclor in healthy Korean adult. The bioavailability was examined on 20 healthy volunteers who received a single dose (250 mg) of each drug in the fasting state in a randomized balanced 2-way crossover design. After dosing, blood samples were collected for a period of 6hours. Plasma concentrations of cefaclor were determined using HPLC with UV detection. The pharmacokinetic parameters $(AUC_{0-6hr},\;C_{max},\;T_{max},\;AUC_{int},\;K_e,\;t_{1/2},\;Vd)$ F, and CL/F) were calculated with non-compartmental pharmacokinetic analysis. The ANOVA test was utilized for the statistical analysis of the $T_{max},\;log-transformed\;AUC_{0-6hr}\;log-transformed\;C_{max},\;t_{l/2},\;V_d/F$, and CL/F. The ratios of geometric means of AUC0-6hr and $C_{max}$ between test drug and reference drug were $103.2\%\;(6.74\;{\mu}g{\cdot}hr/ml\;vs\;6.53{\pm}g{\cdot}hr/ml)\;and\;100.4\%\;(4.85\;{\mu}g\ml\;vs\;4.82\;{\mu}g/ml)$, respectively. The $T_{max}$ of test drug and reference drug were $0.9\pm0.38\;hr\;and\;0.83\pm0.34$ hrs, respectively. The $90\%$ confidence intervals of mean difference of logarithmic transformed $AUC_{0-6h},\;and\;C_{max}$ were log $0.98{\sim}log$ 1.08 and log $0.88{\sim}log1.15$, respectively. It shows that the bioavailability of test drug is equivalent with that of reference drug. The estimated half-life of this study was longer $(1.21\pm0.27\;hrs\;vs\;0.5-1\;hr)$, the Vd/F was larger $(68.89\pm25.72L$ vs 24.9L), and the CL/F was higher $(38.62\pm7.09\;L/hr$ vs 24.9 L/hr) than the previously reported values.

  • PDF

굴루코파지 정(염산메트폴민 500 mg)에 대한 그리코민 정의 생물학적 동등성 (Bioequivalence of Glycomin Tablet to Glucophage Tablet (Metformin HCl 500 mg))

  • 조혜영;문재동;이용복
    • Journal of Pharmaceutical Investigation
    • /
    • 제32권3호
    • /
    • pp.223-229
    • /
    • 2002
  • Metformin is an oral antihyperglycemic agent used in the therapy of noninsulin-dependent diabetes mellitus and does not cause hypoglycemia at the therapeutic dose. Its mechanism of action may involve an increased binding of insulin to its receptors and glucose uptake at the post-receptor level. The purpose of the present study was to evaluate the bioequivalence of two metformin tablets, Glucophage (Daewoong Pharmaceutical Co., Ltd.) and Glycomin (Ilsung Pharmaceuticals Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). The metformin release from the two metformin tablets in vitro was tested using KP VII Apparatus II method with various dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty four normal male volunteers, $23.75{\pm}1.96$ years in age and $68.77{\pm}10.41\;kg$ in body weight, were divided into two groups with a randomized $2{\times}2$ cross-over study. After one tablet containing 500 mg as metformin was orally administered, blood was taken at predetermined time intervals and the concentrations of metformin in serum were determined using HPLC with UV detector. Besides, the dissolution profiles of two metformin tablets were very similar at 떠1 dissolution media. The pharmacokinetic parameters such as $AVC_t,\;C_{max}\;and\;T_{max}$ were calculated. The ANOVA test was performed for the statistical analysis of the logarithmically transformed $AVC_t\;and\;C_{max}$, untransformed $T_{max}$. The results showed that the differences in $AVC_t,\;C_{max}\;and\;T_{max}$ between two tablets based on the Glucophage were 0.09%, 6.09% and -8.22%, respectively. There were no sequence effects between two tablets in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log(0.8) to log(1.25) $(e.g.,\;log(0.94){\sim}log(1.09)\;and \;log(1.01){\sim}log(1.15)$\;for\;AVC_t\;and\;C_{max},\;respectively)$, indicating that Glycomin tablet is bioequivalent to Glucophage tablet.

레보프라이드 정(레보설피리드 25 mg)에 대한 레보피드 정의 생물학적 동등성 (Bioequivalence of Levopid Tablet to Levopride Tablet (Levosulpiride 25 mg))

  • 조혜영;강현아;문재동;이용복
    • Journal of Pharmaceutical Investigation
    • /
    • 제32권2호
    • /
    • pp.127-133
    • /
    • 2002
  • Levosulpiride is the 1evo-enantiomer form of racemic sulpiride, a benzamide derivative selectively inhibiting dopaminergic $D_2$ receptors at the trigger zone both in the central nervous system and in the gastrointestinal tract. The purpose of the present study was to evaluate the bioequiva1ence of two levosulpiride tablets, Levopride (SK Pharmaceutical Co., Ltd.) and Levopid (Dae Won Pharmaceutical Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). The levosulpiride release from the two levosulpiride tablets in vitro was tested using KP VII Apparatus II method with various different kinds of dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty eight normal male volunteers, $23.82{\pm}3.26$ years in age and $69.13{\pm}8.58$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After one tablet containing 25 mg of levosulpiride was orally administered, blood was taken at predetermined time intervals and the concentrations of levosulpiride in serum were determined using HPLC method with fluorescence detector. The dissolution profiles of two levosulpiride tablets were very similar at all dissolution media. Besides, the pharmacokinetic parameters such as $AUC_t,\;C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t\;and\;C_{max}$ and untransformed $T_{max}$. The results showed that the differences in $AUC_t,\;C_{max}\;and\;T_{max}$ between two tablets based on the Levopride were -1.17%, 1.20% and -1.09%, respectively. There were no sequence effects between two tablets in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log(0.8) to log(1.25) $(e.g.,\;log(0.93){\sim}log(1.07)\;and\;log(0.90){\sim}log(1.14)\;for\;AUC_t\;and\;C_{max}$, respectively). The 90% confidence interval using untransformed data was within ${\pm}20%$ $(e.g.,\;-19.47{\sim}16.20\;for\;T_{max})$. All parameters met the criteria of KFDA guideline for bioequivalence, indicating that Levopid tablet is bioequivalent to Levopride tablet.

티로프라미드 주사제의 생물학적 동등성 평가를 위한 GC/MS 방법 (Bioequivalence Evaluation of the Tiropramide Formulation by GC/MS)

  • 명승운;김명수;김혜영;곽현태;민혜기;손동렬;홍영훈
    • 분석과학
    • /
    • 제14권3호
    • /
    • pp.221-229
    • /
    • 2001
  • 본 연구에서는 이미 허가되어 시판되고 있는 D제약의 "티로파주"(대조약, 염산티로프라미드로서 1mL당 16.67mg 함유)와 S제약의 "티램주"(시험약)이 생물학적으로 동등한지의 여부를 판정하고자 시행되었다. 두 제제를 건강한 성인 남자 16인의 지원자에게 라틴방격법에 따라서 근육 주사한 후, 고체-액체 추출법으로 추출하여, GC/MS로 티로프라미드의 혈장 중 농도를 측정하고 이로부터 최고 혈장중 농도 (Cmax), 최고 혈장중 농도 도달시간(Tmax), 혈장중 약물농도-시간 곡선하 면적(AUC)에 대하여 식품의약품안정청(이하 식약청이라 함)과 서울대학교 약학대학이 공동 개발한 분산분석 프로그램에 의하여 분산분석을 행하였다. 정량을 위한 검정 곡선의 상관계수는 $R^2=0.998$로 좋은 직선성을 나타내었고, 검출한계는 0.1ng/mL였다.

  • PDF

세파클러 캅셀제에 대한 생물학적 동등성 평가 (Bioequivalence of Cefaclor Capsules Following Single Dose Administration to Healthy Male Volunteers)

  • 복혜숙;김명민;권이오;최경업
    • 한국임상약학회지
    • /
    • 제7권1호
    • /
    • pp.17-21
    • /
    • 1997
  • Cefaclor is a second generation cephalosporin antibiotic that shows a potent antibacterial activity against both Gram-positive and Gram-negative bacteria, when it is orally administered. Due to its patent expiration, a number of generic drugs have been marketed, but not yet elucidated to ensure therapeutic equivalence. In this study, cefaclor capsules manufactured by Chong Kun Dang were bioequivallently assessed by comparing with $Ceclor^{TM}$ introduced originally by Daewoong Lilly. A total of 16 healthy male volunteers were evaluated in a randomized crossover manner with a 2-week washout period. Concentrations of cefaclor in plasma were measured upto 6 hours following a single oral administration of two capsules (500 mg of cefaclor) by high-performance liquid chromatography with UV detection. Although the plasma concentration at 6 hours was not detected, the computed half-life of cefaclor was approximately 0.5 hours. The area under the concentration-vs-time curve from 0 to 4 hours $(AUC_{0-4h})$ was calculated by the trapezoidal summation method. The differences in mean values of $AUC_{0-4h}$, peak plasma concentration $(C_{max})$, and time to peak concentration $(T_{max})$ between the two products were $4.63\%,\;1.84\%,\;and\3.28\%$, respectively. The least significant differences at $\alpha4= 0.05 for $AUC_{0-4h},\;C_{max},\;and\;T_{max}\;were\;6,53\%,\;4.05\%,\;and\;6.47\%$, respectively. In conclusion, the test drug was bioequivalent with the reference drug.

  • PDF

돼지에서 두 가지 Cefquinome 2.5% 제제의 생물학적 동등성 평가 (Bioequivalence Evaluation of Two Cefquinome 2.5% Injectable Products in Piglets)

  • 송인배;김태원;이홍기;김명석;황윤환;박병권;임종환;윤효인
    • 한국임상수의학회지
    • /
    • 제29권3호
    • /
    • pp.233-236
    • /
    • 2012
  • Cefquinome은 제4세대 cephalosporin으로 동물전용의약품으로 개발되었으며, ${\beta}$-lactamases에 대해서 매우 안정하고, 그람 음성 세균 및 양성 세균에 대한 광범위한 살균력을 가지고 있다. 본 연구는 현재 시판중인 cefquinome 주사제를 이유 자돈에 2 mg/kg 용량으로 근육 주사한 후 약물동태학적 특성을 파악하여 두 제제의 생물학적 동등성을 평가하였다. Cefquinome의 혈중 농도는 액체크로마토그래프/질량분석기를 이용하여 분석하였으며, 생물학적 동등성을 판정하기 위한 약물동태학적 인자로는 혈중 최고 농도 ($C_{max}$)와 혈장 농도 곡선하 면적 ($AUC_{0{\rightarrow}{\infty}}$)을 사용하였다. 시험약과 대조약의 혈중 최고 농도는 $4.34{\pm}0.58{\mu}g/mL$$4.22{\pm}0.47{\mu}g/mL$로 각각 나타났으며, 혈장 농도 곡선 하 면적은 $10.43{\pm}1.96{\mu}g{\cdot}h/mL$$10.25{\pm}2.98{\mu}g{\cdot}h/mL$로 관찰되었다. 로그변환한 약물동태학적 인자의 평균비율의 90% 신뢰 구간은 $C_{max}$의 경우 0.941-1.115이었고, $AUC_{0{\rightarrow}{\infty}}$의 경우 0.927-1.172로서 생물학적 동등성 기준인 0.8-1.25를 모두 만족시켰다. 이상의 결과로 시판중인 두 cefquinome 제제는 생물학적으로 동등하다고 판단된다.

반고형 제제의 제품허가 후 변경사항을 다루는 SUPAC-SS (Usefulness of SUPAC-SS in Dealing with Postapproval Changes to Semisold Dosage Forms)

  • 조미현;석귀덕;사홍기
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권3호
    • /
    • pp.207-224
    • /
    • 2005
  • The objective of this study was to explore the principles of SUPAC-SS and its regulatory application in handling postapproval changes to nonsterile semisolid dosage forms. The types of postapproval changes that SUPAC-SS described were modifications in formulation (components and composition), batch size, manufacturing equipment & process, and the site of manufacturing. SUPAC-SS defined the levels of postapproval changes and what chemistry, manufacturing, and control tests should be conducted for each change level. The guidance also specified several occasions the manufacturers should perform in vitro release test (Franz cell diffusion test) and/or in vivo bioequivalence test. Finally, SUPAC-SS classified appropriate filing forms to be used in supporting postapproval changes. It was crystal clear that SUPAC-SS helped maintain the safety and quality of approved semisolid dosage forms when they were subject to certain postapproval changes. The availability of SUPAC-SS made contributions to reducing regulatory burdens of the industry, as well as expediting the postapproval process of regulatory agencies. This study also shed light on the background of relevant pharmaceutical sciences that the SUPAC-SS guidance adopted. Finally, the KFDA and the industry were strongly urged to implant a similar guidance in handling postapproval changes to semisolid dosage forms available in the Korean marketplace.

임상시험심사위원회 위원과 연구자를 대상으로 연구의 위험평가 설문조사 (Survey of Risk Evaluation in the Clinical Research for IRB Members and Researchers)

  • 최용성;이선주;임현우;최병인;이재원;오상철;신임희;허정식;권복규;김진석;유소영;조현인;이미경;신희영;김덕언
    • 대한기관윤리심의기구협의회지
    • /
    • 제1권1호
    • /
    • pp.5-21
    • /
    • 2019
  • Purpose: Institutional review board (IRB) classifies risks of clinical trials into less than minimal risk, minor increase over minimal risk, and more than minimal risk. Based on classification and evaluation for risk, IRB decides whether permitting consent exemption or asking additional protection for clinical research subject or not. The purpose of this study is to analyze how IRB members evaluate minimal risk by sending questionnaire survey with 12 predetermined scenarios. Methods: IRB members and researchers (pediatrician, gastroenterologist, neurologist, and neurosurgeon) in 11 different hospitals were asked to answer survey questions via email or online. We analyzed the differences of answers among several subgroups in each predetermined scenarios. Result: Responders were 212 personnel(110 researchers and 102 IRB members) from 11 centers. There were significant differences between IRB members and researchers in response such as blood sampling, skin prick test, one time catheterization in a girl, spinal tapping in child, non-enhance MRI in child, non-enhance MRI with chrolal hydrate in a child, spinal tapping without anesthesia in adult, bioequivalence test, gastric endoscopy, and non-enhance CT. significant differences between medical IRB members and non-medical members were also revealed in one time catheterization in a girl, spinal tapping in a child, non-enhance MRI in a child, bioequivalence test. Depending on researchers' department, they responded differently in several questionnaires as well. Conclusions: We have found that IRB members and researchers evaluate the risks differently. Researchers compared to IRB members, medical IRB members compared to non-medical members answered less than minimal risk in many cases. In assessing and evaluating the risks associated with the study, medical IRB members answered predetermined scenarios as less dangerous compared to non-medical IRB members. Difference among researchers where also revealed significantly. Researchers answered predetermined scenarios as less dangerous compare to other department researchers, especially in predetermined scenarios containing procedures they are familiar with.

  • PDF