• Title/Summary/Keyword: binary mixing test

Search Result 8, Processing Time 0.021 seconds

An Experimental Study of a Heat pipe with Binary Mixture Working Fluid for Solar Collector (2 성분 혼합물을 작동유체로 사용하는 태양열 집열기용 히트파이프의 실험적 연구)

  • Jung, Eui-Guk;Boo, Joon-Hong;Chung, Won-Bok
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.13-18
    • /
    • 2003
  • Heat pipes with binary mixture fabricated and tested for applications where condenser temperature is in a range of $10^{\circ}C$ to $130^{\circ}C$. The pipe materials 8.0 mm O.D. cupper tube and the working fluids are ethanol-water mixtures. The total length of test of the heat pipe was 1710mm in which evaporator section was 1570mm, adiabatic section was 50mm and condenser section was 90mm. Mixing ratios of ethanol and water could be variable in mole fraction. Temperature of condenser section was $10^{\circ}C$, $80^{\circ}C$ and $130^{\circ}C$. Heat pipe performance experimental study was accomplished with change of mixing ratio in these temperatures. The fill charge ratio was 20% of the heat pipe volume. Wick structure was woven-wire and method of experimental work was that thermal load was increased 20W step until the heat pipe wall temperature reached at $150^{\circ}C$. Results were following: At coolant $10^{\circ}C$ and $130^{\circ}C$, mixing ratio that have beat thermal performance was 0.8M+ and at coolant $80^{\circ}C$, was 0.3 ${\sim}$ 0.5 M+.

  • PDF

Changes in Physico-chemical Properties of Single or Mixture State of DMF, MEK and Toluene in Synthetic Leather Factories (합성피혁제조업에서 취급하는 DMF, MEK, Toluene의 단일과 혼합물질 상태에 따른 물리·화학적 특성 변화)

  • Kim, Ki-Woong;Won, Yong Lim;Park, Dong Jin;Lee, Jung-Suk;Han, In-Soo;Lee, Su-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.238-245
    • /
    • 2014
  • Objectives: It was known that workers in synthetic leather company are mainly co-exposed to dimethylformamide(DMF) with methyl ethyl ketone(MEK) or toluene(TOL) instead of a single dimethylformamide. This study was examined to the physico-chemical properties in single DMF and binary mixture DMF with MEK or TOL. Materials: Physico-chemical properties were measured by Korean and American Standard Test Methods. Results: Boiling point, specific gravity and flash point in single DMF were significantly higher than binary mixture DMF with MEK or TOL and such difference was dependent on the mixing ratio of MEK and TOL, and low explosion limit in binary mixture DMF with TOL was only significantly lower than single DMF. However, Reid vapor pressure had significantly higher in binary mixture DMF with MEK or TOL compared with single DMF. Conclusions: Our results demonstrate that the binary mixture DMF with MEK or TOL synergistically increases volatilization of DMF. It was concluded that the interaction between DMF and MEK and/or TOL might play a key role in the volatilization process of DMF under environmental conditions of workplace.

Experimental Investigation of Electrochemical Corrosion and Chloride Penetration of Concrete Incorporating Colloidal Nanosilica and Silica Fume

  • Garg, Rishav;Garg, Rajni;Singla, Sandeep
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.440-452
    • /
    • 2021
  • Enhancement of durability and reduction of maintenance cost of concrete, with the implementation of various approaches, has always been a matter of concern to researchers. The integration of pozzolans as a substitute for cement into the concrete is one of the most desirable technique. Silica fume (SF) and colloidal nanosilica (CS) have received a great deal of interest from researchers with their significant performance in improving the durability of concrete. The synergistic role of the micro and nano-silica particles in improving the main characteristics of cemented materials needs to be investigated. This work aims to examine the utility of partial substitution of cement by SF and CS in binary and ternary blends in the improvement of the durability characteristics linked to resistance for electrochemical corrosion using electrical resistivity and half-cell potential analysis and chloride penetration trough rapid chloride penetration test. Furthermore, the effects of this silica mixture on the compressive strength of concrete under normal and aggressive environment have also been investigated. Based on the maximum compression strength of the concrete, the optimal cement substituent ratios have been obtained as 12% SF and 1.5% CS for binary blends. The optimal CS and SF combination mixing ratios has been obtained as 1.0% and 12% respectively for ternary blends. The ternary blends with substitution of cement by optimal percentage of CS and SF exhibited decreased rate for electrochemical corrosion. The strength and durability studies were found in consistence with the microstructural analysis signifying the beneficiary role of CS and SF in upgrading the performance of concrete.

Optimization of Conditions for the Preparation of W/O Emulsion Containing Eugenolchitosan (Eugenolchitosan 함유 유중수적형 유화 형성 조건 최적화)

  • Kim, Je-Jung;Chang, Pahn-Shick;Jung, Byung-Ok;Park, Dong-Ki
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.423-428
    • /
    • 2003
  • Stabilities of W/O emulsions containing eugenolchitosan (EuCs) prepared from chitosan and eugenol were compared to determine the optimal conditions for the ratio of water (core phase) to corn oil (continuous phase), the concentration of EuCs, storage temperature, and the extent of homo-mixing. The optimal ratio of water to corn oil was 2:3 (w/w). The effects of EuC concentrations, and singular vs. binary system of emulsifiers on the storage stability of the emulsion were investigated with EuCs and polyoxyethylene sorbitan monolaurate. The emulsion was stable, showing more than 95% emulsion stability index (ESI) value, when the concentration of EuCs was more than 0.18% (w/v). ESI value of binary emulsifier system was almost equal to that of singular emulsifier system at the concentration of 0.18% (w/v). At this singular emulsifier system, the W/O emulsion formed by EuCs had ESI value of 100%. The optimal concentration of EuCs was determined as 0.18% (w/v). The highest stability of the emulsion was obtained from the homo-mixing at 11,000 rpm for 10 sec and the storage temperature ranging $25{\sim}65^{\circ}C$. EuCs produced from this study was mutagenecity-negative on Ames test and contained no heavy metal ions.

Pool Boiling Heat Transfer Coefficient of HFC32/HFC152a on a Plain Surface (평판 표면에서 HFC32/HFC152a 혼합냉매의 풀 비등 열전달계수)

  • Kang, Dong-Gyu;Lee, Yohan;Jung, Dongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.9
    • /
    • pp.484-492
    • /
    • 2013
  • Nucleate pool boiling heat transfer coefficients (HTCs) are measured with HFC32/HFC152a mixture at several compositions. All data are taken at the liquid pool temperature of $7^{\circ}C$, on a horizontal plain square surface of $9.53{\times}9.53$ mm, with heat fluxes of 10 $kW/m^2$ to 100 $kW/m^2$ with an interval of 10 $kW/m^2$, in the increasing order of heat flux. Test results show that the HTCs of these mixtures are up to 45% lower than those of the ideal HTCs calculated by a linear mixing rule with pure fluids' HTCs, due to the mass transfer resistance associated with non-azeotropic refrigerant mixtures. Pool boiling data show the deduction in HTCs with an increase in GTD of the mixture. The present mixture data agree well with five well known correlations, within 20% deviation.

Measurement and Evaluation of Flash Point for the DMF Contained Organic Solvent Mixtures (DMF함유 혼합 유기용제에 대한 인화점의 측정과 평가)

  • Lee, Jung-Suk;Han, Ou-Sup;Lee, Keun-Won
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.9-15
    • /
    • 2019
  • The flash points of DMF based organic solvent mixtures used in the synthetic leather manufacturing process were measured. The test group was composed of seven types of solvent mixtures, which included DMF, toluene, and MEK. Each flash point was tested according to the international standard test methods of KS M 2010. The flash points were then predicted using some prediction models and compared with the measured data. From the analysis results, the binary mixtures with a mole ratio of less than approximately 0.7 showed that the measured values were under 25 ℃. This showed that the expectation for the flammable risk lowering effects due to the mixing of high flash point materials was reduced. In addition, the predicted values were evaluated using the average absolute deviation (A.A.D). The results showed that the Le Chatelier's models had an "A.A.D" of 1.95 ℃ and were the closest to the measured values.

Petrology of host granites and enclaves from the Bohyeonsan area, Euiseong Basin (의성분지 보현산 일대 화강암류와 포획암에 대한 암석학적 연구)

  • 좌용주;김건기
    • The Journal of the Petrological Society of Korea
    • /
    • v.9 no.3
    • /
    • pp.187-203
    • /
    • 2000
  • Mafic microgranular enclaves (MME) occur in the granites from the Bohyunsan area. The host granites are generally of granodioritic and granitic compositions. The MME can be divided into magic mineral clusters, quartz diorite and diorite according to their occurrence. Halter variation diagrams show linear trends between the MME and the host granites. Though the rim compositions of plagioclase in the host granites and the MME are similar the core compositions of plagioclase in some host granites show abnormally high An content. The Mg/(Mg+Fe) ratio of hornblende in the host granites gradually increase from the core to the rim. The chemical composition of minerals in the host granites had been affected by more marc magma composition. The modelling of major elements of the MME and hybrid host granites also indicate that they result from simple mingling/mixing between a dioritic magma and the host granite magma. The MME are thus interpreted to be globules of a more mafic magma which intruded the granite magma. Partial equilibration has been achieved between the MME and the host granites after they were commingled with each other.

  • PDF

An Experimental Study on the Self-Consolidating Concrete with EP Nylon Fiber (EP 나일론섬유를 혼입한 자기충전콘크리트(SCC)에 관한 실험적 연구)

  • Ryou, Jae Suk;Lee, Yong Soo;Jeon, Joong Kyu;Jeon, Chan Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.159-168
    • /
    • 2011
  • In this study, we find out the feasibility of self-consolidating concrete with EP nylon fiber. Three kinds of method were used; when length of nylon fiber is differed for the experiment to investigate usability of nylon fiber with enhanced performance by dispersing-agent coating in self-consolidating concrete, when mixing in other organic fibers (polypropylene, cellulose) and in case of Binary Blended and Ternary Blended concrete mixed with different types of mineral admixtures (blast-furnace slag and fly ash). Based on the results of the experiment described above, comparison was made on the basic properties and dynamic characteristics of general fiber reinforced concrete mixed with enhanced performance nylon fiber and SCC mixed with enhanced performance nylon fiber as a Mock-up test prior to the experiment of application to the actual structure. Considering characteristics and durability of the fresh and hardened self-compacting concrete, dynamic characteristics and durability were found to be more outstanding when using nylon fiber for the mineral admixtures used, dynamic characteristics and durability were found to be more outstanding when using blast-furnace slag.