• 제목/요약/키워드: bias ratio

검색결과 630건 처리시간 0.028초

Superhydrophobic nanostructured non-woven fabric using plasma modification

  • Shin, Bong-Su;Lee, Kwang-Reoul;Kim, Ho-Young;Moon, Myoung-Woon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.320-320
    • /
    • 2011
  • We describe fabrication of superhydrophobic surface on non-woven fabric (NWF) having nano-hairy structures and a hydrophobic surface coating. Oxygen plasma was irradiated on NWF for nano-texuring and a precursor of HMDSO (Hexamethydisiloxane) was introduced as a surface chemical modification for obtaining superhydrophobicity using 13.56 MHz radio frequency-Plasma Enhanced Chemical Vapor Deposition (rf-PECVD). O2 plasma treatment time was varied from 1 min to 60 min at a bias voltage of 400V, which fabricated pillar-like structures with diameter of 30 nm and height of 150 nm on NWF. Subsequently, hydrophobic coating using hexamethyldisiloxane vapor was deposited with 10 nm thickness on NWF substrate at a bias voltage of 400 V. We evaluate superhydrophobicity of the modified NWF with sessile drop using goniometer and high speed camera, in which aspect ratio of nanohairy structures, contact angle and contact angle hysteresis of the surfaces were measured. With the increase of aspect ratio, the wetting angle increased from $103^{\circ}$ to $163^{\circ}$, and the contact angle hysteresis decreased dramatically below $5^{\circ}$. In addition, we had conducted experiment for nucleation and condensation of water via E-SEM. During increasing vapor pressure inside E-SEM from 3.7 Torr to over 6 Torr which is beyond saturation point at $2^{\circ}C$, we observed condensation of water droplet on the superhydropobic NWF. While the condensation of water on oxygen plasma treated NWF (superhydrophilic) occurred easily and rapidly, superhydrophobic NWF which was fabricated by oxygen and HMDSO was hardly wet even under supersaturation condition. From the result of wetting experiment and water condensation via E-SEM, it is confirmed that superhydrophobic NWF shows the grate water repellent abilities.

  • PDF

지적전문가 지식 기반의 반자동 방식에 의한 지적불부합지 정리 방법 개발 (Semi Automatic Adjustment Method Development of Cadastral Non-coincidence based on knowledge of an expert on Cadastral)

  • 홍성언;김현석
    • Spatial Information Research
    • /
    • 제14권3호
    • /
    • pp.271-284
    • /
    • 2006
  • 본 연구에서는 지적도 전산파일과 현황을 참조할 수 있는 공간 데이터를 이용하여 지적불부합지를 정리할 수 있는 방법을 제시하고자 하였다. 방법론을 설계함에 있어 지적불부합지 정리의 정확성과 안정성 확보를 위해 지적전문가 지식을 기반으로 하는 반자동 방식을 모색하고자 하였다. 그리고 불부합지 유형 중에서 회전형, 편위형, 회전/편위형을 주 대상으로 하였다. 지적불부합지를 반자동으로 정리할 수 있는 프로토타입 시스템을 설계 구현하여 사례지역에 대해 매칭 기준점을 선정하고, 최적의 매칭 회전량(-0.4%)을 분석하여 불부합지를 보정하였다. 그러나 본 연구의 방법으로는 면적 증감형 및 불규칙유형의 불부합지를 정리하기에 한계성이 있는 것으로 나타나 이러한 유형에 대해서는 실측을 동반하여 정리하는 것이 효율적일 것으로 판단된다.

  • PDF

외부 환경영향에 대한 밀도비 의존 3영양단계의 개체군 동태 모델 (Modeling on Ratio-Dependent Three-Trophic Population Dynamics Responding to Environmental Impacts)

  • 이상희;최경희;전태수
    • 생태와환경
    • /
    • 제37권3호통권108호
    • /
    • pp.304-312
    • /
    • 2004
  • 수 생태계 내에서 흔히 볼 수 있는 3영양단계 먹이사슬 구조를 이루는 종들이 밀도비 의존 모델로써 구현 될 때 외부 환경에 대해서 어떻게 반응하는지를 연구하였다. 환경 요인은 주기적 요인과 일반적 노이즈 두 부분으로 나누었다. 주기적 요인이 온도로써 대표되었을 때 온도변이를 바이어스와 주기로 나누었고, 기타 복합적인 노이즈는 가우스 분포로 나타내었다. 온도변이 바이어스 ${\varepsilon}$, 온도주기 ${\Omega}$, 및 가우스 노이즈 크기 ${\'{O}}$가 서로 결합하여 3영양단계 먹이사슬에서 개체군 멸절을 포함한 다양한 개체군 동태를 보여 주었다. 변수의 적절한 값에 따라 '안정된 제한 사이클'이나 '이상한 끌개'를 보여 주었으며, 전체적으로 개체군 동태는 환경 변수에 따라 민감하게 반응하였고, 포식자 및 최상위포식자 개체군의 멸절시간이 조절되었다.

Periodontal health status, oral microbiome, white-spot lesions and oral health related to quality of life-clear aligners versus fixed appliances: A systematic review, meta-analysis and meta-regression

  • Ana Sandra Llera-Romero;Milagros Adobes-Martin;Jose Enrique Iranzo-Cortes;Jose Maria Montiel-Company;Daniele Garcovich
    • 대한치과교정학회지
    • /
    • 제53권6호
    • /
    • pp.374-392
    • /
    • 2023
  • Objective: Assess and evaluate the different indicators of oral health-related quality of life (OHRQoL) among patients treated with clear aligners (CAs) versus those treated with conventional fixed orthodontics (FAs). Methods: An electronic search was performed on the database is Web of Science, Scopus, and Embase databases. Randomized and non-randomized control trials, cross-sectional, prospective cohort and retrospective trials were included. Quality was assessed with risk of bias tool and risk of bias in non-randomised studies. Meta-analyses were performed with random effects models, estimating the standardized and non-standardized mean differences, odds ratio and risk ratio as the measure of effect. The effect on time was determined using a meta-regression model. Results: Thirty one articles were included in the qualitative synthesis and 17 in the meta-analysis. CAs had a significantly lower negative impact on QoL, with an "important" effect size, while the influence of time was not significant. Periodontal indicators plaque index (PI), gingival index (GI), probing depth (PD), and bleeding on probing show significantly better values in patients treated with CAs, with moderate to large effect sizes. PI and GI have a significant tendency to improve over time. In microbiological indicators, CAs present a lower biofilm mass without differences in the percentage of patients with high counts of Streptococcus mutans and Lactobacilli bacteria. The risk of white spot lesion onset is ten times lower in carriers of CAs. Conclusions: Patients wearing CAs show better periodontal indicators, less risk of white spot development, less biofilm mass and a better QoL than patients with FAs.

전력반도체 응용을 위한 용액 공정 인듐-갈륨 산화물 반도체 박막 트랜지스터의 성능과 안정성 향상 연구 (Solution-Processed Indium-Gallium Oxide Thin-Film Transistors for Power Electronic Applications)

  • 김세현;이정민;;김민규;정유진;백강준
    • 한국전기전자재료학회논문지
    • /
    • 제37권4호
    • /
    • pp.400-406
    • /
    • 2024
  • Next-generation wide-bandgap semiconductors such as SiC, GaN, and Ga2O3 are being considered as potential replacements for current silicon-based power devices due to their high mobility, larger size, and production of high-quality wafers at a moderate cost. In this study, we investigate the gradual modulation of chemical composition in multi-stacked metal oxide semiconductor thin films to enhance the performance and bias stability of thin-film transistors (TFTs). It demonstrates that adjusting the Ga ratio in the indium gallium oxide (IGO) semiconductor allows for precise control over the threshold voltage and enhances device stability. Moreover, employing multiple deposition techniques addresses the inherent limitations of solution-processed amorphous oxide semiconductor TFTs by mitigating porosity induced by solvent evaporation. It is anticipated that solution-processed indium gallium oxide (IGO) semiconductors, with a Ga ratio exceeding 50%, can be utilized in the production of oxide semiconductors with wide band gaps. These materials hold promise for power electronic applications necessitating high voltage and current capabilities.

Comparative Efficacy and Safety of Radiofrequency Ablation and Microwave Ablation in the Treatment of Benign Thyroid Nodules: A Systematic Review and Meta-Analysis

  • Hendra Zufry;Timotius Ivan Hariyanto
    • Korean Journal of Radiology
    • /
    • 제25권3호
    • /
    • pp.301-313
    • /
    • 2024
  • Objective: The current body of evidence lacks clarity regarding the comparative efficacy and safety of radiofrequency ablation (RFA) and microwave ablation (MWA) as minimally invasive treatments for benign thyroid nodules. The primary objective of this study is to clarify these concerns. Materials and Methods: A comprehensive search was conducted using the Cochrane Library, Scopus, Europe PMC, and Medline databases until October 10th, 2023, using a combination of relevant keywords. This study incorporated literature that compared RFA and MWA for benign thyroid nodules. The primary outcome was the volume reduction ratio (VRR) from baseline to follow-up. Secondary outcomes were symptom score, cosmetic score, ablation time, major complications rate, hemorrhage, hoarseness, skin burn, cough, and sympathetic nerve injury. We used Risk of Bias in Non-randomized Studies - of Interventions (ROBINS-I) tool to assess the risk of bias in the included studies. We employed random effects models to analyze the standardized mean difference (SMD) and odds ratio for the presentation of outcomes. Results: Nine studies with 2707 nodules were included. The results of our meta-analysis indicated similar efficacy between RFA and MWA in terms of VRR during the 1 (SMD 0.06; 95% confidence interval [CI]: -0.13 to 0.26; P = 0.52) and 3 (SMD 0.11; 95% CI: -0.03 to 0.25; P = 0.12) months of follow-up. VRR was significantly higher in RFA than in MWA at the 6 (SMD 0.25; 95% CI: 0.06-0.43; P = 0.008) and 12 month of follow-up (SMD 0.38; 95% CI: 0.17 to 0.59; P < 0.001). There were no significant differences between RFA and MWA in symptom scores, cosmetic scores, or the incidence of complications, including hemorrhage, hoarseness, skin burn, cough, and sympathetic nerve injury. Conclusion: RFA showed a higher VRR than MWA at 6 and 12-month follow-ups, with a comparable safety profile.

Tunnel i unction-Mangnetorsistance in Co-Al-O$_{x}$-NiFe with oxidation conditions of Al thickness

  • Jeon, Dong-Min;Park, Jin-Woo;Suh, Su-Jeong
    • 한국표면공학회지
    • /
    • 제34권5호
    • /
    • pp.494-498
    • /
    • 2001
  • Ferromagnets(FM)-Al-$O_{x}$ -Ferromagnets (FM) tunneling junctions were evaluated by changing the fabricating conditions of an Al-X$/_{x}$ layer. The junction composed of a thicker Al-$O_{x}$ shows the low resistance and the stable MR ratio about 16% in a wide range of oxidation time. For the junctions with the thinner Al-$O_{x}$ , they showed a fast increase of the barrier width as an increase of an oxidation time and exhibited a strong bias dependence. As oxidation time increased, the coercivity ($H_{c}$ ) of bottom Co layer increased gradually due to the local oxidation of Co bottom layer at a interface. However, the small formation of Co oxide did not largely influence on the deterioration of MR ratio.

  • PDF

Characteristics of a Carbon Nanotube-based Tunnel Magnetoresistance Device

  • Kim, Jinhee;Woo, Byung-Chill;Kim, Jae-Ryoung;Park, Jong-Wan;So, Hye-Mi;Kim, Ju-Jin
    • Journal of Magnetics
    • /
    • 제7권3호
    • /
    • pp.98-100
    • /
    • 2002
  • Tunnel magnetoresistive devices using an individual multi-walled carbon nanotube were fabricated and their low-temperature electrical transport propertiers were investigated. With the ferromagnetic Co electrodes, the multi-walled carbon nanotube exhibited hysteretic magnetoresistance curve at low temperatures. Depending on the temperature and the bias current, the magnetoresistance ratio can be as high as 16% at the temperature of 2.2 K. Such high magnetoresistance ratio indicates a long diffusion length of the multi-walled carbon nanotube.

Polarization-Diversity Cross-Shaped Patch Antenna for Satellite-DMB Systems

  • Lim, Jong-Hyuk;Back, Gyu-Tae;Yun, Tae-Yeoul
    • ETRI Journal
    • /
    • 제32권2호
    • /
    • pp.312-318
    • /
    • 2010
  • A small reconfigurable patch antenna is proposed to achieve polarization diversity for digital multimedia broadcasting systems at 2.6 GHz. To obtain polarization diversity, a pair of on-slit PIN diodes is inserted in each diagonal of a cross-shaped patch. Thus, four PIN-diodes on these slits are utilized to change the connection of the slits and thus achieve polarization. Bias circuits for the diodes are allocated in the cutting corner of the cross-shaped patch to minimize the antenna size. The antenna produces left-hand circular polarization, right-hand circular polarization, or linear polarization, depending on the PIN-diode status. Analysis of circular polarization operation is explicated. Measurements show a gain of about 1.5 dB, a cross polarization of about -20 dB, and an axial ratio of about 2.5 dB.

MEICP에 의한 (Ba,Sr)$TiO_3$ 박막의 식각 메커니즘에 관한 연구 (A Study on the Etching Mechanism of (Ba,Sr)$TiO_3$ Thin Films using MEICP)

  • 민병준;김창일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 전자세라믹스 센서 및 박막재료 반도체재료 일렉트렛트 및 응용기술
    • /
    • pp.52-55
    • /
    • 2000
  • In this study, (Ba,Sr)$TiO_3$(BST) thin films were etched with a magnetically enhanced inductively coupled plasma(MEICP) as a function Ar/$CF_4$ gas mixing ratio. Experiment was done by varying the etching parameters such as rf power, dc bias voltage and chamber pressure. The maximum etch rate of the BST films was 1700 ${\AA}/min$ under $CF_4/(CF_4+Ar)$ of 0.1, 600 W/350 V and 5 mTorr. The selectivity of BST to Pt and PR was 0.6, 0.7, respectively. X -ray photoelectron spectroscopy(XPS) studies shows that there are surface reaction between Ba, Sr, Ti and C, F radicals during the etching. To analyze the composition of surface residue remaining after the etching, films etched with different $CF_4$/Ar gas mixing ratio were investigated using XPS.

  • PDF