• 제목/요약/키워드: bias ratio

검색결과 639건 처리시간 0.025초

Arsenic의 첨가량에 따른 방사선 검출센서 (a-Se)의 전기적 특성 비교 (The Comparison of Electric Characteristics of Radiation Detective Sensor(a-Se) with changing composition ratio of Arsenic)

  • 석대우;강상식;이동길;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.391-394
    • /
    • 2002
  • There has recently been much interest and research in developing digital x-ray systems based on using amorphous selenium(a-Se) photoconductors as the image receptor. The amorphous selenium layer that is currently being studied for use as an x-ray photoconductor is not pure a-Se but rather amorphous selenium alloyed with arsenic. We fabricated samples using the selenium and arsenic alloy with various concentrations of the arsenic. In this work, x-ray photoconductor using amorphous selenium alloyed with arsenic were fabricated with different concentrations of the arsenic (0.1 wt.%, 0.3wt.%, 0.5wt.%, 1wt.%, 1.5wt.%, 3wt.%, 5wt.%). The seven kind of samples was fabricated with a-Se alloyed with arsenic through vacuum thermal evaporation. We also investigate the arsenic concentration dependence on the device performance in radiation detector. The electric characteristics of radiation detector devices with changing additive ratio of the arsenic is performed by measuring the x-ray induced photocurrent and integrating it over time to find the total charge. The thickness of a-Se is $100{\mu}m$. Bias voltages $3V/{\mu}m$, $6V/{\mu}m$$9V/{\mu}m$ are applied at the samples. As results, the net charge of a-Se 0.3% As sample is $526.0pC/mR/cm^2$ at $9V/{\mu}m$ bias. The net charge is decreased as with the increasing additive ratio of arsenic.

  • PDF

유도 결합 플라즈마를 이용한 TiN 박막의 식각 특성 (Etch Characteristics of TiN Thin Films in the Inductively Coupled Plasma System)

  • 엄두승;강찬민;양성;김동표;김창일
    • 한국표면공학회지
    • /
    • 제41권3호
    • /
    • pp.83-87
    • /
    • 2008
  • This study described the effects of RF power, DC bias voltage, chamber pressure and gas mixing ratio on the etch rates of TiN thin film and selectivity of TiN thin film to $SiO_2$ with $BCl_3$/Ar gas mixture. When the gas mixing ratio was $BCl_3$(20%)/Ar(80%) with other conditions were fixed, the maximum etch rate of TiN thin film was 170.6 nm/min. When the DC bias voltage increased from -50 V to -200 V, the etch rate of TiN thin film increased from 15 nm/min to 452 nm/min. As the RF power increased and chamber pressure decreased, the etch rate of TiN thin film showed an increasing tendency. When the gas mixing ratio was $BCl_3$(20%)/Ar(80%) under others conditions were fixed, the intensity of optical emission spectra from radical or ion such as Ar(750.4 nm), $Cl^+$(481.9 nm) and $Cl^{2+}$(460.8 nm) was highest. The TiN thin film was effectively removed by the chemically assisted physical etching in $BCl_3$/Ar ICP plasma.

소화성 궤양에 대한 오패산의 치료효과 : 체계적 문헌고찰과 메타분석 (The Effect of Opae-san for Peptic Ulcer Disease: A Systematic Review and Meta-Analysis)

  • 이유리;조나경;김경순;최홍식;김승모
    • 대한한방내과학회지
    • /
    • 제39권6호
    • /
    • pp.1136-1149
    • /
    • 2018
  • Objectives: The aim of this study was to perform a meta analysis of randomized controlled trials (RCTs) that applied Opae-san to peptic ulcer. Methods: The databases NDSL, RISS, KISS, KISTI, Oasis, DBpia, Cochrane, EMBASE, Pubmed, and CNKI were searched to identify RCTs that evaluated the therapeutic response to Opae-san on peptic ulcer. The selected studies were assessed using Cochrane Group's risk of bias tool. Results: 12 RCTs were selected from a total of 312 identified. Combined therapies of Opae-san plus triple therapy were superior to only triple therapy in achieving the effective rate (risk ratio=1.26, 95% CI: 1.17 to 1.35, p<0.001, I2=0%), the helicobacter pylori eradication rate (risk ratio=1.23, 95% CI: 1.12 to 1.34, p<0.001, I2=7%) and the recurrence rate (risk ratio=0.31, 95% CI: 0.12 to 0.82, p=0.02, I2=0%). But only Opae-san was not superior in achieving the effective rate compared to anti gastric secretion drugs. Conclusions: The current evidence suggests that combined therapies of Opae-san plus triple therapy yield a higher effective rate, and helicobacter pylori eradication rate and a lower recurrence rate. However, in most of these studies, it is difficult to evaluate the bias and therefore better designed studies are needed.

LTE-A 기반 이종 네트워크에서 CRE 영역내 단말들의 수를 고려한 ABS 비율 산출 방법 (ABS Ratio Estimation Considering the Number of UEs in CRE Regions for LTE-A Heterogeneous Networks)

  • 선종석;노병희
    • 한국차세대컴퓨팅학회논문지
    • /
    • 제13권5호
    • /
    • pp.104-112
    • /
    • 2017
  • 3GPP에서는 HetNet에서 매크로셀과 스몰셀 간 송수신 전력 차이에 따른 트래픽 불균형을 완화하기 위해 업로드 자원이 더 효율적인 스몰셀을 선택하는 CRE (Cell Range Expansion)를 도입하였다. 그리고 이로 인한 신호 간섭 문제 해결을 위하여 ABS (Almost Blank Subframes) 방법이 제안되었다. 본 논문에서는 매크로셀 내의 스몰셀의 개수와 CRE로 확장된 지역에 위치한 단말, 매크로셀 단말의 비율에 따라 ABS 비율을 산출하는 방법을 제안한다. 제안한 방법을 LTESim 시뮬레이터상에 구현하여, 기존에 제안된 방법들과 성능을 비교하였다. 실혐 결과는, 제안된 방법이 기존 방법들과 비교하여 throughput 과 패킷 손실 성능을 향상시킴을 보여준다. 특히 성능 향상이 CRE 경계값에 의하여 달라짐을 보이고, 최적의 성능 개선을 구하기 위한 CRE 경계값이 존재함을 보인다.

Ratio and Product Type Exponential Estimators of Population Mean in Double Sampling for Stratification

  • Tailor, Rajesh;Chouhan, Sunil;Kim, Jong-Min
    • Communications for Statistical Applications and Methods
    • /
    • 제21권1호
    • /
    • pp.1-9
    • /
    • 2014
  • This paper discusses the problem of estimation of finite population mean in double sampling for stratification. In fact, ratio and product type exponential estimators of population mean are proposed in double sampling for stratification. The biases and mean squared errors of proposed estimators are obtained upto the first degree of approximation. The proposed estimators have been compared with usual unbiased estimator, ratio and product estimators in double sampling for stratification. To judge the performance of the proposed estimators an empirical study has been carried out.

Multivariate analysis of longitudinal surveys for population median

  • Priyanka, Kumari;Mittal, Richa
    • Communications for Statistical Applications and Methods
    • /
    • 제24권3호
    • /
    • pp.255-269
    • /
    • 2017
  • This article explores the analysis of longitudinal surveys in which same units are investigated on several occasions. Multivariate exponential ratio type estimator has been proposed for the estimation of the finite population median at the current occasion in two occasion longitudinal surveys. Information on several additional auxiliary variables, which are stable over time and readily available on both the occasions, has been utilized. Properties of the proposed multivariate estimator, including the optimum replacement strategy, are presented. The proposed multivariate estimator is compared with the sample median estimator when there is no matching from a previous occasion and with the exponential ratio type estimator in successive sampling when information is available on only one additional auxiliary variable. The merits of the proposed estimator are justified by empirical interpretations and validated by a simulation study with the help of some natural populations.

Estimation of the Population Mean in Presence of Non-Response

  • Kumar, Sunil;Bhougal, Sandeep
    • Communications for Statistical Applications and Methods
    • /
    • 제18권4호
    • /
    • pp.537-548
    • /
    • 2011
  • In this paper following Singh et al. (2008), we propose a modified ratio-product type exponential estimator to estimate the finite population mean $\={Y}$ of the study variable y in presence of non-response in different situations viz. (i) population mean $\={X}$ is known, and (ii) population mean $\={X}$ is unknown. The expressions of biases and mean squared error of the proposed estimators have been obtained under large sample approximation using single as well as double sampling. Some realistic conditions have been obtained under which the proposed estimator is more efficient than usual unbiased estimators, ratio estimators, product estimators and exponential ratio and product estimators reported by Rao (1986) and Singh et al. (2010) are found to be more efficient in many situations.

Ratio Cum Regression Estimator for Estimating a Population Mean with a Sub Sampling of Non Respondents

  • Kumar, Sunil
    • Communications for Statistical Applications and Methods
    • /
    • 제19권5호
    • /
    • pp.663-671
    • /
    • 2012
  • In the present study, a combined ratio cum regression estimator is proposed to estimate the population mean of the study variable in the presence of a non-response using an auxiliary variable under double sampling. The expressions of bias and mean squared error(MSE) based on the proposed estimator is derived under double (or two stage) sampling to the first degree of approximation. Some estimators are also derived from the proposed class by allocating the suitable values of constants used. A comparison of the proposed estimator with the usual unbiased estimator and other derived estimators is carried out. An empirical study is carried out to demonstrate the performance of the suggested estimator and of others; it is endow that the empirical results backing the theoretical study.

Modified Ramp Reset Waveform for High Contrast Ratio in AC PDPs

  • Kim, Jae-Sung;Yang, Jin-Ho;Ha, Chang-Hoon;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.199-202
    • /
    • 2002
  • In general, the background light produced during the reset period deteriorates the dark room contrast ratio in AC PDP. In this paper, we propose a modified ramp reset pulse that can reduce the background light to imperceptible level. In the new reset waveform, the discharges between the scan and sustain electrodes are minimized by applying a positive bias voltage to the sustain electrode and only the weak discharges between the scan and address electrodes occur during the reset period. We adopted a MgO coated phosphor layer to get the same level of voltage margin in the new reset pulse scheme compared to that of the conventional ramp reset pulse one. As a result, the voltage margin is maintained at the same level and the dark room contrast ratio is improved dramatically.

  • PDF

Biased SNR Estimation using Pilot and Data Symbols in BPSK and QPSK Systems

  • Park, Chee-Hyun;Hong, Kwang-Seok;Nam, Sang-Won;Chang, Joon-Hyuk
    • Journal of Communications and Networks
    • /
    • 제16권6호
    • /
    • pp.583-591
    • /
    • 2014
  • In wireless communications, knowledge of the signal-to-noise ratio is required in diverse communication applications. In this paper, we derive the variance of the maximum likelihood estimator in the data-aided and non-data-aided schemes for determining the optimal shrinkage factor. The shrinkage factor is usually the constant that is multiplied by the unbiased estimate and it increases the bias slightly while considerably decreasing the variance so that the overall mean squared error decreases. The closed-form biased estimators for binary-phase-shift-keying and quadrature phase-shift-keying systems are then obtained. Simulation results show that the mean squared error of the proposed method is lower than that of the maximum likelihood method for low and moderate signal-to-noise ratio conditions.