• Title/Summary/Keyword: bias effect

Search Result 1,466, Processing Time 0.03 seconds

Effect of Electrical Stimulation on Upper Extremity Function in Stroke Patients: A Systematic Review Based on Randomized Controlled Trials (뇌졸중 환자의 상지 기능에 기능적 전기 자극이 미치는 영향: 무작위대조군연구에 기초한 체계적 고찰)

  • Hwang, Su-jin;Seo, Yeon-ju
    • PNF and Movement
    • /
    • v.20 no.2
    • /
    • pp.147-156
    • /
    • 2022
  • Objective: Electrical stimulation is an assistive technology used to aid the recovery of upper limb use after stroke. The purpose of this systematic review was to determine the effects of electrical stimulation on upper extremity function in individuals with hemiparetic stroke and to develop an evidence base that supports the use of electrical stimulation for upper limb recovery after stroke. Design: A systematic review based on randomized controlled trials (RCTs). Methods: Studies published before April 20 2021 were collected for this review by searching PubMed, four other databases, and RCTs that reported the effects of electrical stimulation on upper extremity function in individuals with the characteristic stroke type. Information on the following parameters was extracted from each study: surname of first author, published year, country, participants, intervention, intervention's intensity, comparison, outcomes, additional therapy, and summary of results. This review also evaluated the bias within each study, including any selection bias, performance bias, detection bias, attrition bias, and reporting bias. Results: This review included five RCTs, and 208 stroke patients were included in the analysis. Stroke patients who underwent electrical stimulation showed significantly improved grip and pinch strengths, wrist range of motion, and basic daily living compared to those in the control group; however, there was no improvement in upper extremity function. Of the selected papers, 60% showed a "high risk" of performance bias, and 20% showed a "high risk" of detection bias. Conclusions: The results of this systematic review suggest that electrical stimulation provides some benefits to stroke patients, such as improved hand strength and range of motion. However, future studies are needed to provide clinical evidence of the effects of electrical stimulation on upper extremity function in stroke patients.

Impact of Diverse Configuration in Multivariate Bias Correction Methods on Large-Scale Climate Variable Simulations under Climate Change

  • de Padua, Victor Mikael N.;Ahn Kuk-Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.161-161
    • /
    • 2023
  • Bias correction of values is a necessary step in downscaling coarse and systematically biased global climate models for use in local climate change impact studies. In addition to univariate bias correction methods, many multivariate methods which correct multiple variables jointly - each with their own mathematical designs - have been developed recently. While some literature have focused on the inter-comparison of these multivariate bias correction methods, none have focused extensively on the effect of diverse configurations (i.e., different combinations of input variables to be corrected) of climate variables, particularly high-dimensional ones, on the ability of the different methods to remove biases in uni- and multivariate statistics. This study evaluates the impact of three configurations (inter-variable, inter-spatial, and full dimensional dependence configurations) on four state-of-the-art multivariate bias correction methods in a national-scale domain over South Korea using a gridded approach. An inter-comparison framework evaluating the performance of the different combinations of configurations and bias correction methods in adjusting various climate variable statistics was created. Precipitation, maximum, and minimum temperatures were corrected across 306 high-resolution (0.2°) grid cells and were evaluated. Results show improvements in most methods in correcting various statistics when implementing high-dimensional configurations. However, some instabilities were observed, likely tied to the mathematical designs of the methods, informing that some multivariate bias correction methods are incompatible with high-dimensional configurations highlighting the potential for further improvements in the field, as well as the importance of proper selection of the correction method specific to the needs of the user.

  • PDF

The Effects of Instruction and Stimulus Presentation Time in Attention Bias Modification Training on Social Anxiety Symptom Group (주의편향수정 훈련에서 지시문과 자극제시 시간의 효과: 사회불안증상 집단을 대상으로)

  • Kim, Seul-A;Hong, Chang-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.641-649
    • /
    • 2020
  • This study was conducted to examine the effects of instruction (explicit, implicit) and stimulus presentation time (300 ms, 500 ms) in ABM training. According to the Social Avoidance and Distress Scale (SADS) and the attention bias score (ABS), 60 undergraduate students were selected. All participants' SADS scores were above 82 and their ABS score was greater than 0. The training group was explicit-300 ms training group (n=10), explicit-500 ms training group (n=10), implicit-300 ms training group (n=10) and implicit-500 ms training group (n=10). In the implicit instruction group, only information about procedure was included. In the explicit instruction group, additional information about training manipulation (the probe always presented at the location of the preceding neutral stimuli) was provided. The control group were placebo-300 ms control group(n=10) and placebo-500 ms control group(n=10). After 8 sessions of training, the effect was only found in instruction conditions. The explicit training group showed significantly decreased SADS after training. ABS changed significantly in all three conditions but the treatment effect was most effective in the explicit instruction condition. No significant effect was found in the stimulus presentation time. These results suggest that explicit instruction might promote the effect of ABM training compared to implicit instruction.

Current Increase Effect and Prevention for Electron Trapping at Positive Bias Stress System by Dropping the Nematic Liquid Crystal on the Channel Layer of the a-InGaZnO TFT's

  • Lee, Seung-Hyun;Heo, Young-Woo;Kim, Jeong-Joo;Lee, Joon-Hyung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.163-163
    • /
    • 2015
  • The effect of nematic liquid crystal(5CB-4-Cyano-4'-pentylbiphenyl) on the amorphous indium gallium zinc oxide thin film transistors(a-IGZO TFTs) was investigated. Through dropping the 5CB on the a-IGZO TFT's channel layer which is deposited by RF-magnetron sputtering, properties of a-IGZO TFTs was dramatically improved. When drain bias was induced, 5CB molecules were oriented by Freedericksz transition generating positive charges to one side of dipoles. From increment of the capacitance by orientation of liquid crystals, the drain current was increased, and we analyzed these phenomena mathematically by using MOSFET model. Transfer characteristic showed improvement such as decreasing of subthreshold slope(SS) value 0.4 to 0.2 and 0.45 to 0.25 at linear region and saturation region, respectively. Furthermore, in positive bias system(PBS), prevention effect for electron trapping by 5CB liquid crystal dipoles was observed, which showing decrease of threshold voltage shift [(${\delta}V$]_TH) when induced +20V for 1~1000sec at the gate electrode.

  • PDF

Investigation of bias illumination stress in solution-processed bilayer metal-oxide thin-film transistors

  • Lee, Woobin;Eom, Jimi;Kim, Yong-Hoon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.302.1-302.1
    • /
    • 2016
  • Solution-processed amorphous metal-oxide thin-film transistors (TFTs) are considered as promising candidates for the upcoming transparent and flexible electronics due to their transparent property, good performance uniformity and possibility to fabricate at a low-temperature. In addition, solution processing metal oxide TFTs may allow non-vacuum fabrication of flexible electronic which can be more utilizable for easy and low-cost fabrication. Recently, for high-mobility oxide TFTs, multi-layered oxide channel devices have been introduced such as superlattice channel structure and heterojunction structure. However, only a few studies have been mentioned on the bias illumination stress in the multi- layered oxide TFTs. Therefore, in this research, we investigated the effects of bias illumination stress in solution-processed bilayer oxide TFTs which are fabricated by the deep ultraviolet photochemical activation process. For studying the electrical and stability characteristics, we implemented positive bias stress (PBS) and negative bias illumination stress (NBIS). Also, we studied the electrical properties such as field-effect mobility, threshold voltage ($V_T$) and subthreshold slop (SS) to understand effects of the bilayer channel structure.

  • PDF

Surrounding rock pressure of shallow-buried bilateral bias tunnels under earthquake

  • Liu, Xin-Rong;Li, Dong-Liang;Wang, Jun-Bao;Wang, Zhen
    • Geomechanics and Engineering
    • /
    • v.9 no.4
    • /
    • pp.427-445
    • /
    • 2015
  • By means of finite element numerical simulation and pseudo-static method, the shallow-buried bilateral bias twin-tube tunnel subject to horizontal and vertical seismic forces are researched. The research includes rupture angles, the failure mode of the tunnel and the distribution of surrounding rock relaxation pressure. And the analytical solution for surrounding rock relaxation pressure is derived. For such tunnels, their surrounding rock has sliding rupture planes that generally follow a "W" shape. The failure area is determined by the rupture angles. Research shows that for shallow-buried bilateral bias twin-tube tunnel under the action of seismic force, the load effect on the tunnel structure shall be studied based on the relaxation pressure induced by surrounding rock failure. The rupture angles between the left tube and the right tube are independent of the surface slope. For tunnels with surrounding rock of Grade IV, V and VI, which is of poor quality, the recommended reinforcement range for the rupture angles is provided when the seismic fortification intensity is VI, VII, VIII and IX respectively. This study is expected to provide theoretical support regarding the ground reinforcement range for the shallow-buried bilateral bias twin-tube tunnel under seismic force.

Effect of DC Bias on the Growth of Nanocrystalline Diamond Film over Poly-Silicon Substrate (DC Bias가 다결정 실리콘 기판 위 나노결정 다이아몬드 박막의 성장에 미치는 영향)

  • Kim, Seon-Tae;Gang, Chan-Hyeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.180-180
    • /
    • 2016
  • 보론이 도핑된 $3{\times}3cm$ 크기의 p 형 다결정 실리콘 기판의 표면을 경면연마한 후, 다이아몬드 입자의 seeding을 위해 슬러리 중 다이아몬드 분말의 입도를 5 nm로 고정하고 초음파 전처리 공정을 진행한 후, 다이아몬드 박막을 증착하였다. 다이아몬드 증착은 Microwave Plasma Chemical Vapor Deposition 장비를 이용하였으며, 공정 조건은 초기 진공 $10{\times}10^{-3}Torr$, 공정 가스 비율 $Ar:CH_4=200:2$, 가스 유량 202 sccm, 공정압력 90 Torr, 마이크로웨이브 파워 600 W, 기판 온도 $600^{\circ}C$이었다. 기판에 DC bias 전압을 인가하는 것을 공정 변수로 하여 0, -50, -100, -150, -200 V로 변화시켜가며, 0.5, 1, 2, 4 h 동안 증착을 진행하였다. 주사전자현미경과 XRD, AFM, 접촉각 측정 장비를 이용하여 증착된 다이아몬드 입자와 막의 특성을 분석하였다. 각 bias 조건에서 초기에는 다이아몬드 입자가 형성되어 성장되었다가 시간이 증가될수록 연속적인 다이아몬드 막이 형성되었다. Table 1은 각 bias 조건에서 증착 시간을 4 h까지 변화시키면서 얻은 다이아몬드 입자 또는 박막의 높이(두께)를 나타낸 것이다. 2 h까지의 공정 초기에는 bias 조건의 영향을 파악하기 어려운데, 이는 bias에 의한 과도한 이온포격으로 입자가 박막으로의 성장에 저해를 받는 것으로 사료된다. 증착시간이 4 h가 경과하면서 -150 V 조건에서 가장 두꺼운 막이 성장되었다. 이는 기판 표면을 덮은 다이아몬드 박막 위에서 이차 핵생성이 bias에 의해 촉진되기 때문으로 해석된다. -200 V의 조건에서는 오히려 막의 성장이 더 느렸는데, 이는 Fig. 1에 보이듯이 과도한 이온포격으로 Si/diamond 계면에서 기공이 형성된 것과 연관이 있는 것으로 보인다.

  • PDF

Effects of Trust, Stigma, Optimistic Bias on Risk Perception of Nuclear Power Plants (원자력발전소에 대한 공중의 신뢰, 낙인과 낙관적 편향성이 위험인식에 미치는 효과)

  • Song, Hae-Ryong;Kim, Won-Je
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.162-173
    • /
    • 2013
  • This study was to examine the effect of trust, stigma, optimistic bias on risk perception of nuclear power plants. For this study, we carried out a survey targeting residents, total of 383, living in Seoul. The findings showed that trust of general public on nuclear power plants influenced negatively on stigma. Second, trust of general public on nuclear power plants influenced not significantly on optimistic bias. Third, stigma of general public on nuclear power plants influenced positively on risk perception. Fourth, optimistic bias of general public on nuclear power plants influenced negatively on risk perception.

Effect of Bias for Snapshots Using Minimum Variance Processor in MFP (최소분산 프로세서를 사용한 정합장 처리에서 신호단편 수에 따른 바이어스의 영향)

  • 박재은;신기철;김재수
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.7
    • /
    • pp.94-100
    • /
    • 2001
  • When using a sample covariance matrix data in paucity of snapshots, adaptive matched field processing will have problem in inverting covariance matrix due to the rank deficiency. The general solutions are diagonal loading and eigenanalysis methods, but there is a significant bias in the power output. This paper presents a quantitative study of bias of power output and the performance of source localization through the simulation and the measured data analysis in fixed source case using the diagonal loading method for the minimum variance processor. Results show that the bias in power output is reduced and the performance of source localization is improved when the number of snapshots is greater than the number of array sensors.

  • PDF

DC Bias Current Influence to the Sensitivity of Orthogonal Fluxgate Sensor Fabricated with NiZn Ferrite Core (NiZn 페라이트코어를 이용하여 제작한 직교형 플럭스게이트 센서의 출력에 미치는 바이어스전류의 영향)

  • Shin, Kwang-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.3
    • /
    • pp.94-97
    • /
    • 2013
  • Orthogonal fluxgate sensor was fabricated with cylinder-shaped NiZn ferrite core, Cu wire through the core and pickup coil wound on the core, and the bias current effect on the output sensitivity of it was investigated. The output ($$\sim_\sim$$ sensitivity) of the sensor was largely dependent on the operation frequency, and the tendency of sensor output was similar to that of the impedance of pickup coil. The maximum output was obtained by adding the DC bias current of which value was over 50% of the excitation current. The output was saturated when the DC bias current was larger than 50% of the excitation current.