• Title/Summary/Keyword: beta ray

Search Result 618, Processing Time 0.025 seconds

Computer Graphics / Molecular Mechanics Studies of ${\beta}$-Lactam Antibiotics. Geometry Comparison with X-Ray Crystal Structures

  • Chung, Sung-Kee;Chodosh, Daniel F.
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.2
    • /
    • pp.185-190
    • /
    • 1989
  • Geometries for a number of representative ${\beta}$ -lactam antibiotics (penams, cephems and monobactams) have been calculated by computer graphics/molecular mechanics energy minimization procedures using both MM2 and AMBER force fields. The calculated geometries have been found in reasonable agreement with the geometries reported in the X-ray crystal structures, especially in terms of the pyramidal character of the amide nitrogen in the ${\beta}$-lactam ring and the Cohen distance. Based on these calculations, it is suggested that the nitrogen atom in the monobactams may also have pyramidal geometries in the biologically active conformations.

Development of Effective ${\gamma}$-ray and ${\beta}$-ray Detection Methods For Low-Level Radioactive Wastes (극저준위 방사성 폐기물을 위한 효율적인 ${\gamma}$-선 및 ${\beta}$-선 측정 방법 개발)

  • Kwak, Sung-Woo;Yeom, Yu-Sun;Kim, Ho-Kyung;Cho, Gyu-Seong;Park, Joo-Wan;Kim, Chang-Lak;Song, Myung-Jae
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.393-398
    • /
    • 2001
  • The non-combustible RI wastes disposed of in hospital every year emit ${\gamma}$-ray or ${\beta}$-ray but their activities are very low to the extent of background. Development of more simple methods is needed because the conventional detection methods are so ineffective and complex. In this study, to solve this problem, detection method using efficiency curve for ${\gamma}$-ray emitting radioactive wastes measurement is proposed and experimental detection efficiency equation is also determined through HPGe's standard specimen measurement. For ${\beta}$-emitting radioisotopes detection, new measurement method using detection efficiency estimated by Monte Carlo simulation and SBD measurements is also proposed. According to the results of this paper, the unknown activity of low-level radioactive wastes without LSC requiring the preparation of standard sample and measurement for standard source detection efficiency could be determined efficiently and simply about ${\pm}17%$ in errors by using the theoretical detection efficiency and the SBD measurement result.

  • PDF

Effect on Pancreatic Beta Cells and Nerve Cells by Low LET X-ray (Low LET X-ray가 췌장 ${\beta}$ 세포와 신경세포에 미치는 효과)

  • Park, Kwang-Hun;Kim, Kgu-Hwan
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.21-28
    • /
    • 2014
  • Cultured pancreatic beta cells and nerve cells, it is given normal condition of 10% FBS (fetal bovine serum), 11.1 mM glucose and hyperglycemia codition of 1% FBS, 30 mM glucose. For low LET X-ray irradiated with 0.5 Gy/hr dose-rate(total dose: 0.5 to 5 Gy). Survival rates were measured by MTT assay. When non irradiated, differentiated in the pancreatic beta cells experiment is hyperglycemia conditions survival rate compared to normal conditions survival rate seemed a small reduction. However increasing the total dose of X-ray, the survival rate of normal conditions decreased slightly compared to the survival rate of hyperglycemia conditions, the synergistic effect was drastically reduced. When non irradiated, undifferentiated in the nerve cells experiment is hyperglycemia conditions survival rate compared to normal conditions survival rate seemed a large reduction. As the cumulative dose of X-ray normal conditions and hyperglycemia were all relatively rapid cell death. But the rate of decreased survivals by almost parallel to the reduction proceed and it didn't show synergistic effect.

Comparison of the PM-10 mass concentration in different measurement methods and meteorological conditions (측정방법 및 기상상태에 따른 PM-10 질량농도 비교)

  • Jung, Chang Hoon;Park, Jin Hee;Hwang, S.M.;Jung, Y.G.
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.53-62
    • /
    • 2009
  • In this study, the continuous monitoring of the concentration of PM-10 atmospheric particulate matter using beta ray attenuation method was compared with gravimetric method from September, 2006 to August, 2007. On the effects of the PM-10 concentration and mass difference by relative humidity and precipitation were considered. The result showed that the measurement error between beta ray method and gravimetric method are within -3~6% in average, which means PM-10 concentration data with beta ray method are relatively comparable. The current study also shows that the high PM-10 concentration events are mainly due to haze, Asian dust, and high relative humidity and the PM-10 mass concentration is closely related with relative humidity and precipitation events. Based on daily mean data, the PM-10 increases as relative humidity increases up to 70~80%, then decreases over 80% due to the precipitation. However, the distinct measurement discrepancy was not shown between beta ray method and gravimetric method based on current results. Consequently, this study shows that the collocated measurement in different instrument is essential in order to quantify the accuracy of PM-10. Furthermore, the more comprehensive and spatially distributed comparison is needed and this is remained for future study.

  • PDF

Analysis of Radiation Dose on Single Cells Using Therapeutic Radioisotopes Using the Monte Carlo Method (몬테카를로 방법을 이용한 치료용 방사성동위원소 사용 시 단일 세포에 대한 선량 분석)

  • Kim, Jung-Hoon;Kim, Yu-Soo
    • Journal of radiological science and technology
    • /
    • v.45 no.5
    • /
    • pp.433-438
    • /
    • 2022
  • Targeted radionuclides treatment (TRT) requires the establishment of treatment plans that consider various factors, such as the type of radionuclides, target organs, and administration methods. For this reason, in this study, the absorption dose of a single cell was analyzed according to the type of radioisotope used to treat target radionuclides. In this study, a simulation was performed on beta rays used in the treatment of target radionuclides at the cell level using MCNPX (ver. 2.5.0). First, according to the calculation formula, the beam path according to the type of radioisotope for treatment was calculated. Second, the amount of self-radiation by beta rays emitted from cell diameters of 5 ㎛ and 10 ㎛ cell nuclei was evaluated. As a result, it showed a high range proportional to the maximum energy of the beta-ray, and the highest self-dose distribution from 177 Lu radiation sources among therapeutic radioisotopes. This was analyzed as a result that is inversely proportional to the maximum energy of the beta-ray, and it suggests that the selection of a nuclide considering the range of the beta-ray is necessary in the treatment of target radionuclides in the future.

Dissolution Enhancements of Tiaprofenic Acid by ${\beta}-Cyclodextrin$ Complexation (${\beta}-Cyclodextrin$과의 복합체 형성에 의한 Tiaprofenic Acid의 용출증가)

  • Chun, In-Koo;Park, In-Sook
    • Journal of Pharmaceutical Investigation
    • /
    • v.16 no.2
    • /
    • pp.55-67
    • /
    • 1986
  • Inclusion complexation of tiaprofenic acid (TPA) with cyclodextrins $({\alpha}-,\;{\beta}-,\;{\gamma}-CyDs)$ in aqueous solution and in solid phase was investigated by solubility method, measurement of partition coefficient, ultra-violet, circular dichroism, infrared spectroscopies, powder X-ray diffractometry and differential scanning calorimetry. Investigations were made to prepare inclusion complexes of TPA with ${\beta}-CyD$ in solid powdered form by coprecipitation, freeze-drying, spray-drying and co-pulverization methods. The coprecipitation, freeze-drying and spray-drying methods were successful in obtaining inclusion complexes. The results showed that the latter two methods might be originally superior to the former in obtaining powdered inclusion completes. Especially, it was shown by powder X-ray diffractometry that spray-dried ${\beta}-CyD$ alone, TPA-spray-dried ${\beta}-CyD$ physical mixture, and spray-dried $TPA-{\beta}-CyD$ complex were amorphous. The dissolution behaviours of $TPA-{\beta}-CyD$ systems prepared by above four methods were compared with those of TPA alone and $TPA-{\beta}-CyD$ physical mixture, and the rates of dissolution of TPA in pH 1.2 buffer were greatly enhanced by inclusion complexation and copulverization.

  • PDF

Evaluation of Hydrocortisone Sustained-Release Suppositories Prepared with Eudragit-Polyethylene Glycol Solid Matrix (유드라짓 및 폴리에틸렌글리콜 고체 매트릭스로 제조한 히드로코르티손 좌제의 서방성 평가)

  • Han, Kun;Kim, Hak-Hyung
    • Journal of Pharmaceutical Investigation
    • /
    • v.20 no.1
    • /
    • pp.13-18
    • /
    • 1990
  • Hydrocortisone (HC) sustained-release suppositories were prepared by using a solid matrix of methacrylic acid-methacrylic acid methyl ester copolymer $(Eudragit\;L_{100}^{R}:\;EL)$ as a poorly water soluble carrier and polyethylene glycole 1540 (PEG) as an water soluble carrier. HC release rate was controlled by complexation with ${\beta}-cyclodextrin$ $({\beta}-CyD)$ which was confirmed by X-ray diffractometry, IR-spectroscopy and differential scanning calorimetry. Release rate of HC from the EL-PEG matrix suppositories decreased with increase of EL contents. The release rale from $HC-{\beta}-CyD$ complex decreased in the following order: $HC-{\beta}-CyD/PEG$ > HC/PEG > $HC-{\beta}-CyD/EL_{10%}-PEG$ > $HC/EL_{10%}-PEG$ > $HC-{\beta}-CyD/EL_{15%}-PEG$ > $HC/EL_{15%}-PEG$ > $HC-{\beta}-CyD/EL_{20%}-PEG$ > $HC/EL_{20%}-PEG$. The crystallinity of HC in polymer matrix was identified using X-ray diffractometer and the surface of matrix suppositories after release test was examined by scanning electron microscopy. The sustained release of HC from these matrix suppositories was attributed to the network structure of EL.

  • PDF

Compensation of Light Scattering Method for Real-Time Monitoring of Particulate Matters in Subway Stations (지하역사 내 미세먼지 실시간 모니터링을 위한 광산란법 보정)

  • Kim, Seo-Jin;Kang, Ho-Seong;Son, Youn-Suk;Yoon, Sang-Lyeor;Kim, Jo-Chun;Kim, Gyu-Sik;Kim, In-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.533-542
    • /
    • 2010
  • The $PM_{10}$ concentrations in the underground should be monitored for the health of commuters on the underground subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. As for the measurement of $PM_{10}$ concentrations, instruments based on $\beta$-ray absorption method and gravimetric methods are being used. But the instruments using gravimetric method give us 20-hour-average data and the $\beta$-ray instruments can measure the $PM_{10}$ concentration every one hour. In order to keep the $PM_{10}$ concentrations under a healthy condition, the air quality of the underground platform and tunnels should be monitored and controlled continuously. The $PM_{10}$ instruments using light scattering method can measure the $PM_{10}$ concentrations every less than one minute. However, the reliability of the instruments using light scattering method is still not proved. The purpose of this work is to study the reliability of the instruments using light scattering method to measure the $PM_{10}$ concentrations continuously in the underground platforms. One instrument using $\beta$-ray absorption method and two different instruments using light scattering method (LSM1, LSM2) were placed at the platform of the Jegi station of Seoul metro line Number 1 for 10 days. The correlation between the $\beta$-ray instrument and the LSM2 ($r^2$=0.732) was higher than that between the $\beta$-ray instrument and the LSM1 ($r^2$=0.393). Thus the LSM2 was chosen for further analysis. Three different regression analysis methods were tested: Linear regression analysis, Nonlinear regression analysis and Orthogonal regression analysis. When the instruments using light scattering method were used, the data measured these instruments have to be converted to actual $PM_{10}$ concentrations using some factors. With these analyses, the factors could be calculated successfully as linear and nonlinear forms with respect to the data. And the orthogonal regression analysis was performed better than the ordinary least squares method by 28.45% reduction of RMSE. These findings propose that the instruments using light scattering method light scattering method can be used to measure and control the $PM_{10}$ concentrations of the underground subway stations.

The crystal and molecular structure of $\gamma$-hydroxy-.$\beta$-amino butyric acid

  • Kim, Yang-Bae
    • Archives of Pharmacal Research
    • /
    • v.8 no.1
    • /
    • pp.1-6
    • /
    • 1985
  • The crystal structure or $\gamma$-hydroxy-$\betha$-aminobutyric acid was determined by MULTAN system with X-ray intensity data on a diffractometer and refined by the least-squares method to an R-value 0.034 for 711 reflections. The crystals were orthorhombic, space group $P2_{1}2_{1}2_{1}$, Z = 4, with a = 10.220, b = 8.257 and c = 6.556$\AA$. The molecule takes the zwitterionic form and skeletal conformation is trans-transform. The molecules are held together by intra-and intermolecular NH-O and OH--O hydrogen bonds.

  • PDF

Relationships between TSP and PM10 Concentrations in the Ambient Atmosphere (대기 중 TSP와 PM10 농도의 관련성)

  • 최진수;백성옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 1998
  • Relationships between TSP and PM10 concentrations were evaluated using their respective data sets collected from Taegu and Kyeungsan areas during the period of December 1993 to November 1994. The collection of data was made using the gravimetric and $\beta$-ray absorption ($\beta$-MPM) methods for 7 days of every month from three urban sites in Taegu and one suburban site in Kyeungsan. Correlation coefficients between TSP and PM10 concentrations for these four sampling sites were found in the range of 0.85 $\sim$ 0.96. Correlation analysis was also conducted for $\beta$-PM concentration data that were measured only from the residential and commercial sites. The correlation coefficients between TSP and $\beta$-PM concentrations were 0.9 in the residential site and 0.8 in the commercial site. By contrast, the correlation coefficients between PM10 $\beta$-PM concentrations were almost identical for both the residential and commercial sites with a value of 0.88. The mean ratio for PM10 to TSP concentrations for all sites was appeared to be 0.68. The analysis of seasonal trends in PM10/TSP ratios showed that the contribution of PM10 to TSP concentrations was more significant during winter (0.70 $\sim$ 0.75) than during summer (0.61 $\sim$ 0.68). The results of this study may provide empirical informations on the compatability of aerosol data measured by different sampling methods.

  • PDF