• Title/Summary/Keyword: best constants

Search Result 112, Processing Time 0.028 seconds

Comparative Study on Various Ductile Fracture Models for Marine Structural Steel EH36

  • Park, Sung-Ju;Lee, Kangsu;Cerik, Burak Can;Choung, Joonmo
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.3
    • /
    • pp.259-271
    • /
    • 2019
  • It is important to obtain reasonable predictions of the extent of the damage during maritime accidents such as ship collisions and groundings. Many fracture models based on different mechanical backgrounds have been proposed and can be used to estimate the extent of damage involving ductile fracture. The goal of this study was to compare the damage extents provided by some selected fracture models. Instead of performing a new series of material constant calibration tests, the fracture test results for the ship building steel EH36 obtained by Park et al. (2019) were used which included specimens with different geometries such as central hole, pure shear, and notched tensile specimens. The test results were compared with seven ductile fracture surfaces: Johnson-Cook, Cockcroft-Latham-Oh, Bai-Wierzbicki, Modified Mohr-Coulomb, Lou-Huh, Maximum shear stress, and Hosford-Coulomb. The linear damage accumulation law was applied to consider the effect of the loading path on each fracture surface. The Swift-Voce combined constitutive model was used to accurately define the flow stress in a large strain region. The reliability of these simulations was verified by the good agreement between the axial tension force elongation relations captured from the tests and simulations without fracture assignment. The material constants corresponding to each fracture surface were calibrated using an optimization technique with the minimized object function of the residual sum of errors between the simulated and predicted stress triaxiality and load angle parameter values to fracture initiation. The reliabilities of the calibrated material constants of B-W, MMC, L-H, and HC were the best, whereas there was a high residual sum of errors in the case of the MMS, C-L-O, and J-C models. The most accurate fracture predictions for the fracture specimens were made by the B-W, MMC, L-H, and HC models.

PLASMA POLYMERIZED THIN FILMS GROWN BY PECVD METHOD AND COMPARISON OF THEIR ELECTROCHEMICAL PROPERTIES

  • I.S. Bae;S.H. Cho;Park, Z. T.;Kim, J.G.;B. Y. Hong;J.H. Boo
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.119-119
    • /
    • 2003
  • Plasma polymerized organic thin films were deposited on Si(100) glass and Copper substrates at 25 ∼ 100 $^{\circ}C$ using cyclohexane and ethylcyclohexane precursors by PECVD method. In order to compare physical and electrochemical properties of the as-grown thin films, the effects of the RF plasma power in the range of 20∼50 W and deposition temperature on both corrosion protection efficiency and physical properties were studied. We found that the corrosion protection efficiency (P$\_$k/), which is one of the important factors for corrosion protection in the interlayer dielectrics of microelectronic devices application, was increased with increasing RF power. The highest P$\_$k/ value of plasma polymerized ethylcyclohexane film (92.1% at 50 W) was higher than that of the plasma polymerized cyclohexane film (85.26% at 50 W), indicating inhibition of oxygen reduction. Impedance analyzer was utilized for the determination of I-V curve for leakage current density and C-V for dielectric constants. To obtain C-V curve, we used a MIM structure of metal(Al)-insulator(plasma polymerized thin film)-metal(Pt) structure. Al as the electrode was evaporated on the ethylcyclohexane films that grew on Pt coated silicon substrates, and the dielectric constants of the as-grown films were then calculated from C-V data measured at 1㎒. From the electrical property measurements such as I-V ana C-V characteristics, the minimum dielectric constant and the best leakage current of ethylcyclohexane thin films were obtained to be about 3.11 and 5 ${\times}$ 10$\^$-12/ A/$\textrm{cm}^2$ and cyclohexane thin films were obtained to be about 2.3 and 8 ${\times}$ 10$\^$-12/ A/$\textrm{cm}^2$.

  • PDF

Non-astronomical Tides and Monthly Mean Sea Level Variations due to Differing Hydrographic Conditions and Atmospheric Pressure along the Korean Coast from 1999 to 2017 (한국 연안에서 1999년부터 2017년까지 해수물성과 대기압 변화에 따른 계절 비천문조와 월평균 해수면 변화)

  • BYUN, DO-SEONG;CHOI, BYOUNG-JU;KIM, HYOWON
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.1
    • /
    • pp.11-36
    • /
    • 2021
  • The solar annual (Sa) and semiannual (Ssa) tides account for much of the non-uniform annual and seasonal variability observed in sea levels. These non-equilibrium tides depend on atmospheric variations, forced by changes in the Sun's distance and declination, as well as on hydrographic conditions. Here we employ tidal harmonic analyses to calculate Sa and Ssa harmonic constants for 21 Korean coastal tidal stations (TS), operated by the Korea Hydrographic and Oceanographic Agency. We used 19 year-long (1999 to 2017) 1 hr-interval sea level records from each site, and used two conventional harmonic analysis (HA) programs (Task2K and UTide). The stability of Sa harmonic constants was estimated with respect to starting date and record length of the data, and we examined the spatial distribution of the calculated Sa and Ssa harmonic constants. HA was performed on Incheon TS (ITS) records using 369-day subsets; the first start date was January 1, 1999, the subsequent data subset starting 24 hours later, and so on up until the final start date was December 27, 2017. Variations in the Sa constants produced by the two HA packages had similar magnitudes and start date sensitivity. Results from the two HA packages had a large difference in phase lag (about 78°) but relatively small amplitude (<1 cm) difference. The phase lag difference occurred in large part since Task2K excludes the perihelion astronomical variable. Sensitivity of the ITS Sa constants to data record length (i.e., 1, 2, 3, 5, 9, and 19 years) was also tested to determine the data length needed to yield stable Sa results. HA results revealed that 5 to 9 year sea level records could estimate Sa harmonic constants with relatively small error, while the best results are produced using 19 year-long records. As noted earlier, Sa amplitudes vary with regional hydrographic and atmospheric conditions. Sa amplitudes at the twenty one TS ranged from 15.0 to 18.6 cm, 10.7 to 17.5 cm, and 10.5 to 13.0 cm, along the west coast, south coast including Jejudo, and east coast including Ulleungdo, respectively. Except at Ulleungdo, it was found that the Ssa constituent contributes to produce asymmetric seasonal sea level variation and it delays (hastens) the highest (lowest) sea levels. Comparisons between monthly mean, air-pressure adjusted, and steric sea level variations revealed that year-to-year and asymmetric seasonal variations in sea levels were largely produced by steric sea level variation and inverted barometer effect.

Optical Properties of Sputtered Ta2O5 Thin Films Using Spectroscopic Ellipsometty (분광타원법을 이용한 스퍼터된 Ta2O5 박막의 광학적 특성)

  • Kim, Sun-Hee;Lee, Eui-Hyun;Jung, In-Woo;Hyun, Jang-Hoon;Lee, Sung-Young;Kang, Man-Il;Ryu, Ji-Wook
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.2
    • /
    • pp.133-140
    • /
    • 2009
  • $Ta_{2}O_{5}$ thin films were deposited by RF magnetron sputtering method under various RF power, substrates and oxygen partial pressure. Elliptic constants were measured by using a phase modulated spectroscopic ellipsometer and analyzed with the Tauc-Lorentz dispersion formula and best fit method in the range of 310$\sim$1239 nm. Also, transmittance spectra of the films were measured by UV -Vis spectrophotometer in the range of 300$\sim$1000 nm. From these data, thickness of $Ta_{2}O_{5}$ and surface layer were analyzed and changes of magnitude and shape of dispersion of optical constants according to fabricated conditions were measured. Also, to evaluate thickness and optical constants data analyzed by Tauc-Lorentz dispersion formula, the measured and analyzed transmittance spectra were compared. In result of the comparison, two spectra were in good agreement each other. Accordingly, it indicates that our ellipsometric analysis is valid.

Desorption of Heavy Petroleum Oils and Heavy Metals from Soils by Flushing Agents (세정제에 의한 복합오염토양으로부터의 중질유 및 중금속 탈착 특성)

  • Yun, Sung Mi;Kim, Gil Ran;Lim, Hee Jun;Kim, Han S.
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.94-103
    • /
    • 2014
  • In this study washing efficiency and desorption isotherms for heavy petroleum oil (HPO), Zn, and Pb bound to complex contaminated soils were examined using various soil flushing agents. Sodium dodecyl sulfate (SDS), methanol, ethylene diamine tetraacetic acid (EDTA), and citric acid were selected as soil flushing agents. 3% (w/v) and 4% SDS showed the highest removal efficiency for HPO, but the difference was not statistically significant (p > 0.05). Thus, 3% SDS was chosen as the best soil flushing agent for HPO. In the case of heavy metals, 0.1-M EDTA showed the highest removal efficiencies. But 0.05-M citric acid was selected due to its economic and eco-friendly strengths. The desorption isotherms obtained using Freundlich and Langmuir models indicated that the maximum desorption characteristics ($K_F$ and $Q_{max}$) of HPO with 4% SDS and 90% methanol and heavy metals with 0.1-M EDTA and 0.1-M citric acid, respectively, were markedly lower than in other cases. In addition, when 4% SDS and 90% methanol were used for HPO in the range of $C_e$ higher than 600 mg/L, and when 0.1M citric acid and 0.1M EDTA were used for Zn and Pb in the range of $C_e$ higher than 300 and 100 mg/L, respectively, the distribution constant converged to certain levels. Thus, constant values of $K_U$ and $K_L$ were determined. It was found that these constants represent the maximum desorption capacity and they can be used as distribution coefficients of desorption equilibrium for the flushing agents. The results of this study provided fundamental information for the selection of the best agents as well as for the process design and operation of soil washing/soil flushing of complex contaminated soils.

Robust optimum design of MTMD for control of footbridges subjected to human-induced vibrations via the CIOA

  • Leticia Fleck Fadel Miguel;Otavio Augusto Peter de Souza
    • Structural Engineering and Mechanics
    • /
    • v.86 no.5
    • /
    • pp.647-661
    • /
    • 2023
  • It is recognized that the installation of energy dissipation devices, such as the tuned mass damper (TMD), decreases the dynamic response of structures, however, the best parameters of each device persist hard to determine. Unlike many works that perform only a deterministic optimization, this work proposes a complete methodology to minimize the dynamic response of footbridges by optimizing the parameters of multiple tuned mass dampers (MTMD) taking into account uncertainties present in the parameters of the structure and also of the human excitation. For application purposes, a steel footbridge, based on a real structure, is studied. Three different scenarios for the MTMD are simulated. The proposed robust optimization problem is solved via the Circle-Inspired Optimization Algorithm (CIOA), a novel and efficient metaheuristic algorithm recently developed by the authors. The objective function is to minimize the mean maximum vertical displacement of the footbridge, whereas the design variables are the stiffness and damping constants of the MTMD. The results showed the excellent capacity of the proposed methodology, reducing the mean maximum vertical displacement by more than 36% and in a computational time about 9% less than using a classical genetic algorithm. The results obtained by the proposed methodology are also compared with results obtained through traditional TMD design methods, showing again the best performance of the proposed optimization method. Finally, an analysis of the maximum vertical acceleration showed a reduction of more than 91% for the three scenarios, leading the footbridge to acceleration values below the recommended comfort limits. Hence, the proposed methodology could be employed to optimize MTMD, improving the design of footbridges.

A Simple Regression Model for Predicting the TC Intensity Change after Landfall over the Korean Peninsula (한반도 상륙 태풍의 강도변화 예측을 위한 단순회귀모형 개발)

  • Choi, Ki-Seon;Kim, Baek-Jo;Lee, Ji-Yun
    • Atmosphere
    • /
    • v.17 no.2
    • /
    • pp.135-145
    • /
    • 2007
  • We developed a simple regression model for predicting the intesity change (central pressure) of major tropical cyclones (TCs) for 24 hours after landfall using 51 TC cases which landed over the Korean Peninsula for 1951-2004. Clusters 1 and 4 with a relatively strong intensity of TC after landfall classified by Choi and Kim (2007) are used to develop a statistical model for the prediction of TC intensity change. Predicting parameters (falling constants) in the regression models $(P_t=P_0+alnt)$ are 6.46 and 10.11 for clusters 1 and 4, respectively. It might be mentioned that there is some feasibility in employing a simple regression model developed in this study for TC intensity change after landfall for operational purpose of TC forecasting compared with RSMC-Tokyo best-track in both TC cases of Clusters 1 and 4 and Ewiniar (0603) case, but the room for improvement of model still remains for further study.

Directed evolution을 이용한 (S)-Ketoprofen ethlyester의 광학분활용 Esterase의 특성 개량

  • Kim, Seung-Beom;Kim, Ji-Hui;Yu, Yeon-U
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.445-449
    • /
    • 2003
  • As for the purpose, we first introduce an random mutation into wild-type gene to expand a mutation space, and then further recombine the mutant genes by staggered extension process PCR. As a result, we obtained the best clones 6-52 that showed a high activity and stability, from a round of error prone and staggered extension process PCR. The purified enzyme showed a similar pH stability to the wild-type enzyme and reveal a slightly high optimum pH at 12. In the optimum temperature, an identical dependency was also showed and a quite high stability in the thermal stability was obtained. Along with this, the enzyme was also stable at a reaction that supplement with a 15 % of ethanol as an additive. The addition of other solvents and surfactants did not improve the reaction and thus resulted in a similar profile to those of wild-type enzyme. The specific activity on the target compound rac-ketoprofen ethyl ester was calculated to be about 85, 000 unit, and the kinetic constants Km and Vmax were determined to be 0.2 mM and 90 mM/mg-protein/min respectively. The deduced amino acid alignment with the wild type enzyme revealed five mutations at L120P, I208V, T249A, D287H and T357A. Based on these observations, the site directed mutagenesis to delineate the mutagenic effect is under progress.

  • PDF

A Comparative Analysis of Pseudophase Ion-Exchange (PIE) Model and Berezin Pseudophase (BPP) Model: Analysis of Kinetic Data for Ionic Micellar-mediated Semi-ionic Bimolecular Reaction

  • Cheong, May-Ye;Ariffin, Azhar;Khan, M.Niyaz
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.7
    • /
    • pp.1135-1140
    • /
    • 2007
  • Pseudo-first-order rate constants (kobs) for the reaction of N-benzylphthalimide (NBPT) with HO- have been determined at 2.0 × 10?4 M NBPT, 1.0 × 10?3 and 2.0 × 10?3 M NaOH as well as varying concentrations of cetyltrimethylammonium bromide ([CTABr]T = 0.0-1.7 × 10?1 M). The effects of [CTABr]T ? CMC (with CMC representing the critical micelle concentration of CTABr) on kobs have been analyzed in terms of Berezin's pseudophase (BPP) model and pseudophase ion-exchange (PIE) model. Although both models give the best observed data fit with least-squares values not significantly different from each other, the calculated values of KS from BPP model appear to be more reliable compared to those from PIE model because the values of KS from BPP model are similar to the corresponding KS values determined spectrophotometrically.

Medical Image Restoration by Digital Image Processing (디지털영상처리를 이용한 의료영상복원)

  • Lee, Won-Seok;Chung, Kil-Soo;Lee, Yong-Gu
    • 전자공학회논문지 IE
    • /
    • v.49 no.2
    • /
    • pp.75-81
    • /
    • 2012
  • In this paper, restoration methods were applied to restore analog medicine images with an aged image added and then blurred by noises. To restore the aged image blurred by the blurring function and added by noises, it was applied to the restoration methods which are inverse filtering and wiener filtering which are linear restoration techniques and Lucy-Richardson's algorithm which is nonlinear restoration technique. Moreover, ROC curve, a subjective evaluation method, was applied to evaluate the image quality of the restoration image. The wiener filtering using the ratio of constants acquired better image than the inverse filtering, but both of them couldn't improve ability to make a diagnosis. The restoration image applied to Lucy-Richardson algorithm was the best performance of the applied techniques and its sensitivity and specitivity were improved by 15[%] as much performance as the original aged image.