• Title/Summary/Keyword: beryllium

Search Result 91, Processing Time 0.026 seconds

Neutronic assessment of BDBA scenario at the end of Isfahan MNSR core life

  • Ahmadi, M.;Pirouzmand, A.;Rabiee, A.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.7
    • /
    • pp.1037-1042
    • /
    • 2018
  • The present study aims to assess the excess induced reactivity in a Miniature Neutron Source Reactor (MNSR) for a Beyond Design Basis Accident (BDBA) scenario. The BDBA scenario as defined in the Safety Analysis Report (SAR) of the reactor involves sticking of the control rod and filling of the inner and outer irradiation sites with water. At the end of the MNSR core life, 10.95 cm of Beryllium is added to the top of the core as a reflector which affects some neutronic parameters such as effective delayed neutrons fraction (${\beta}_{eff}$), the reactivity worth of inner and outer irradiation sites that are filled with water and the reactivity worth of the control rod. Given those influences and changes, new neutronic calculations are required to be able to demonstrate the reactor safety. Therefore, a validated MCNPX model is used to calculate all neutronic parameters at the end of the reactor core life. The calculations show that the induced reactivity in the BDBA scenario increases at the end of core life to $7.90{\pm}0.01mk$ which is significantly higher than the induced reactivity of 6.80 mk given in the SAR of MNSR for the same scenario but at the beginning of the core's life. Also this value is 3.90 mk higher than the maximum allowable operational limit (i.e. 4.00 mk).

The applicability study and validation of TULIP code for full energy range spectrum

  • Wenjie Chen;Xianan Du;Rong Wang;Youqi Zheng;Yongping Wang;Hongchun Wu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4518-4526
    • /
    • 2023
  • NECP-SARAX is a neutronics analysis code system for advanced reactor developed by Nuclear Engineering Computational Physics Laboratory of Xi'an Jiaotong University. In past few years, improvements have been implemented in TULIP code which is the cross-section generation module of NECP-SARAX, including the treatment of resonance interface, considering the self-shielding effect in non-resonance energy range, hyperfine group method and nuclear library with thermal scattering law. Previous studies show that NECP-SARAX has high performance in both fast and thermal spectrum system analysis. The accuracy of TULIP code in fast and thermal spectrum system analysis is demonstrated preliminarily. However, a systematic verification and validation is still necessary. In order to validate the applicability of TULIP code for full energy range, 147 fast spectrum critical experiment benchmarks and 170 thermal spectrum critical experiment benchmarks were selected from ICSBEP and used for analysis. The keff bias between TULIP code and reference value is less than 300 pcm for all fast spectrum benchmarks. And that bias keeps within 200 pcm for thermal spectrum benchmarks with neutron-moderating materials such as polyethylene, beryllium oxide, etc. The numerical results indicate that TULIP code has good performance for the analysis of fast and thermal spectrum system.

Risk Assessment of Airborne Toxic Metals in Thejon Industrial Complex (대전공단지역의 대기중 독성금속에 대한 위해도 평가)

  • Lee, Jin Hong;Yun, Mi Jung;Nam, Byung Hyun;Wang, Chang Keun;Kang, Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.2
    • /
    • pp.1-8
    • /
    • 1999
  • The research centers on the concentration profile and risk assessment of toxic metals for ambient air in Taejon industrial complex. Airborne concentrations of each toxic metal for risk assessment were obtained from 2-year sampling by high volume air sampler and analysis by ICP-MS and ICP-AES in the complex. The long-term arithmetic mean of human carcinogen, arsenic, hexavalent chromium and nickel subsulfide was 5.53, 2.16 and $3.46ng/m^3$ while the mean of probable human carcinogen, beryllium, cadmium and lead was 0.08, 2.35, $293.29ng/m^3$, respectively. And the long-term arithmetic mean concentration of non-carcinogenic metal, manganese was $55.91ng/m^3$. The point risk estimate for the inhalation of carcinogenic metals was $3.6{\times}10^{-5}$, which was higher than a risk standard of $10^{-5}$. About 75% of the cancer risk was to the inhalation of human carcinogen, arsenic. Thus, it is necessary to properly manage arsenic risk in Taejon industrial complex. The point hazard index by the inhalation of manganese was 1.1. Therefore, an investigation into Taejon industrial complex is needed to obtain more fine long-term concentration data for airborne non-carcinogenic metals including manganese.

  • PDF

Ultrasonic Backscattering Profiles from Zirconium Plate with Beryllium Diffusion Layer (베릴륨 표면확산 층을 가진 지르코늄 판재에서의 후방산란 프로파일)

  • Hwang, Y.H.;Choi, H.O.;Park, C.H.;Lee, Y.H.;Kwon, S.D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.342-348
    • /
    • 2003
  • Ultrasonic backscattering profiles of the Zr plates(with a thickness of 1.32mm) with/without Be-Zr alloy layer(with a thickness of $100{\mu}m$) were measured at various incidence positions to evaluate the characteristics of Be diffusion layer. Four principal subprofiles were observed in the backward ultrasound radiated from leaky Lamb waves. The angles and the intensities of the subprofile peaks decreased by the stiffening effect of Be layer. Generation and change of the subprofiles were explained by the acoustical property, collective group velocity and leaky factor difference of the plates under consideration. Backward radiation subprofiles turned out to be an useful method for evaluating thin diffusion layers on plates.

Health Risk Assessment of Airborne Toxic Metals in Taejon Third and Fourth Industrial Complexes (대전 3, 4 공단지역의 대기중 독성금속의 인체 위해도 평가)

  • Lee, Jin-Hong;Jang, Mi-Suk;Lim, Joung-Myung;Ku, Bu-Mi
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.4
    • /
    • pp.271-276
    • /
    • 2000
  • The research centers on the health risk assessment of airborne toxic metals in Taejon third and fourth industrial complexes. Total suspended particulates were collected on glass microfibre filters by high volume air samplers. Fifteen toxic metals including 6 carcinogenic metals were analyzed by ICP-MS and ICP-AES after the pre-treatment of mixed acid extraction. The following results were summarized from the research : 1) the concentrations of TSPs were $17.7{\sim}219.6{\mu}g/m^3$ while the arithmetic mean concentration was $101.7{\mu}g/m^3$; 2) the arithmetic mean concentrations of human carcinogens such as arsenic, hexavalent chromium and nickel subsulfide were 10.22, 6.96 and 6.42 $ng/m^3$, respectively while those of probable human carcinogens such as beryllium, cadmium and lead were 0.13, 3.41, 97.65 $ng/m^3$, respectively; 3) the point risk estimate for the inhalation of carcinogenic metals was $1.5{\times}10^{-4}$, which was much higher than a risk standard of $10^{-5}$; 4) approximately 93% of the cancer risk were to the inhalation of human carcinogens, arsenic and hexavalent chromium, which should be properly managed in Taejon third and fourth industrial complexes.

  • PDF

Theoretical Considerations on the Design of Metal Frames for Refractive Correction (시력교정용 금속테설계의 이론적고찰)

  • Kang, Hyunsik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.39-73
    • /
    • 1998
  • In the 60's to 70's, frame selection was a purely mechanical consideration almost entirely dominated by the optician and his subjective judgments. Toddy the cosmetic factor is predominant. The variety of frame color, materials, and style means that the main burden of selection has passed to the customer, leaving the optician control a subtle factor often difficult to exert. Common materials include nickel silver, Hi-nickel alloy, bronze, stainless steel, gold, gold plated, gold clad, copper beryllium, titanium and sometimes aluminium. In manufacturing of metal frames with the materials, even though fashion is the stimulant of consumer demand, all the metal frame for the prescription to refractive correction should be designed correctly styled eyewear which is cosmetically pleasing, functional correct, physically comfortable, mechanically and structurally perfectible, and temperamentally acceptable.

  • PDF

Reliability Demonstration Test Method for Electromagnetic Shielding Doorset with a Sub-Unit Subjected to Preventive Replacement (예방교체부품을 가지는 전자파차폐용 문세트의 신뢰성입증시험법)

  • Shin, Jung-Hun;Lee, Hyo-Kyung;Jang, Jin;Kim, Do-Sik;Nam, Tae-Yeon;Jung, Dong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.10
    • /
    • pp.1171-1177
    • /
    • 2014
  • An electromagnetic shielding doorset must satisfy requirements associated with both mechanical strength/durability and electromagnetic shielding. Among the primary components of the doorset, a finger strip-a leaftype spring normally made of beryllium copper-is a core part to shield electromagnetic waves as well as to endure repetitive dry sliding friction. This study presented a reliability demonstration test method for the doorset system and, by a simple and simultaneous implementation, of the replacement interval of the finger strip. A rigorous evaluation for the qualification of maintenance or replacement interval is included in the reliability demonstration test of any series system that holds critical maintenance sub-units.

절연절단 방식의 프로브 빔 제작

  • Hong, Pyo-Hwan;Gong, Dae-Yeong;Pyo, Dae-Seung;Lee, Jong-Hyeon;Lee, Dong-In;Kim, Bong-Hwan;Jo, Chan-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.449-449
    • /
    • 2013
  • 최근 반도체 소자의 집적회로는 점점 복잡해지고 있는 반면, 소자의 크기는 작아지고 있으며 그로 인해 패드의 크기가 작아지고 패드사이의 간격 또한 협소해지고 있다. 따라서 웨이퍼 단계에서 제조된 집적회로의 불량여부를 판단하기위한 검사 장비인 프로브카드(Probe Card)의 높은 집적도가 요구되고 있다. 하지만 기존의 MEMS 공법으로 제작되는 프로브 빔은 복잡한 제조 공정과 높은 생산비용, 낮은 집적도의 문제점을 가지고 있다. 본 연구에서는 이러한 문제점을 해결하기 위하여 간단한 제조 공정과 낮은 생산비용, 높은 집적도를 가지는 프로브 빔을 개발하기 위하여 절연절단 방식으로 BeCu (Beryllium-Copper) 프로브 빔을 제작하였다. 낮은 소비 전력으로 우수한 프로브 빔 어레이를 제작하기 위해서 가장 고려해야할 대상은 프로브 빔의 재료와 구조(형상)이다. 절연전단 방식으로 프로브 빔을 형성할 때 요구되는 Fusing current는 프로브 빔의 구조(형상)에 크게 영향을 받는다. 낮은 Fusing current는 소비 전력을 줄여주고, 절연절단으로 형성되는 프로브 빔의 단면(끝)을 날카롭게 하여 프로브 빔과 집적회로의 패드 간의 접촉 저항을 감소시킨다. 프로브 빔의 제작은 BeCu 박판을 빔 형태로 식각하여 제작하였으며, 실리콘 비아 홀(Via hole) 구조의 기판위에 정렬하여 soldering 공정을 통해 실리콘 기판과 BeCu 박판을 접합시켰다. 접합된 프로브 빔의 끝부분을 들어 올린 상태로 전류를 인가하여 stress free 상태로 만들어 내부 응력을 제거하였으며, BeCu 박판에 fusing current를 인가하여 BeCu 박판 프레임으로부터 제거를 하였다. 제작된 프로브 빔의 길이는 1.7 mm, 폭은 $50{\mu}m$, 두께는 $15{\mu}m$, 절단부의 단면적은 1$50{\mu}m^2$로 제작되었다. 그리고 프로브 빔의 절단부의 길이는 $50{\mu}m$ 부터 $90{\mu}m$까지 $10{\mu}m$ 증가시켜 제작되었다. 이후에 절연절단 공정에 요구되는 Fusing current를 측정하였고, 절연절단 후의 절단면의 형상을 SEM (Scanning Electron Microscope)장비를 통하여 확인하였다. 절단부의 길이가 $50{\mu}m$일 때 5.98A의 fusing current를 얻었으며, 절연절단 후 절단부 상태 또한 가장 우수했다. 본 연구에서 제안된 프로브 빔 제작 방법은 프로브카드 및 테스트 소켓(Test socket) 생산에 응용이 가능하리라 기대한다.

  • PDF

2-Wavelength Organic Light-Emitting Diodes Using Bebq2 Selectively Doped with (pq)2Ir(acac) (Bebq2에 (pq)2Ir(acac)가 선택 도핑된 2-파장 유기발광다이오드)

  • Kim, Min-Young;Ji, Hyun-Jin;Jang, Ji-Geun
    • Korean Journal of Materials Research
    • /
    • v.21 no.4
    • /
    • pp.212-215
    • /
    • 2011
  • New organic light-emitting diodes with structure of indium-tin-oxide[ITO]/N,N'-diphenyl-N, N'-bis-[4-(phenyl-m-tolvlamino)-phenyl]-biphenyl-4,4'-diamine[DNTPD]/1,1-bis-(di-4-poly-aminophenyl) cyclohexane[TAPC]/bis(10-hydroxy-benzo(h)quinolinato)beryllium[Bebq2]/Bebq2:iridium(III)bis(2-phenylquinoline-N,C2')acetylacetonate[(pq)2Ir(acac)]/ET-137[electron transport material from SFC Co]/LiF/Al using the selective doping of 5%-(pq)2Ir(acac) in a single Bebq2 host in the two wavelength (green, orange) emitter formation were proposed and characterized. In the experiments, with a 300${\AA}$-thick undoped emitter of Bebq2, two kinds of devices with the doped emitter thicknesses of 20${\AA}$ and 40${\AA}$ in the Bebq2:(pq)2Ir(acac) were fabricated. The device with a 20${\AA}$-thick doped emitter is referred to as "D-1" and the device with a 4${\AA}$-thick doped emitter is referred to as "D-2". Under an applied voltage of 9V, the luminance of D-1 and D-2 were 7780 $cd/m^2$ and 6620 $cd/m^2$, respectively. The electroluminescent spectrum of each fabricated device showed peak emissions at the same two wavelengths: 508 nm and 596 nm. However, the relative intensity of 596 nm to 508 nm at those wavelengths was higher in the D-2 than in the D-1. The D-1 and D-2 devices showed maximum current efficiencies of 5.2 cd/A and 6.0 cd/A, and color coordinates of (0.31, 0.50) and (0.37, 0.48) on the Commission Internationale de I'Eclairage[CIE] chart, respectively.

Influence of Blankholding Force and Blank Diameter on the Drawability and Quality of Very Small Cylindrical Cups (극소형 원통컵의 드로잉성과 품질에 미치는 블랭크 홀딩력과 블랭크 직경의 영향)

  • Lee, K.S.;Kim, J.B.;Jung, W.J.;Kim, J.H.
    • Transactions of Materials Processing
    • /
    • v.23 no.8
    • /
    • pp.489-494
    • /
    • 2014
  • Micro forming is an appropriate process to manufacture very small metal parts which can be employed in the field of electronic devices or electrically controlled mechanical systems. The purpose of the current study was to investigate the influences of both blankholding force and blank diameter for the deep drawing of very small cups. It is essential to control the blankholding force because improper force can result in defects such as wrinkles in the flange or cracks in the corner of the drawn cups. In the current study blankholding force was controlled by springs connected to the blankholder of a press die. Exchangeable bushing dies with various die-corner radii were also used. To obtain the limit drawing ratio for each working condition several sizes of circular specimens were prepared using blanking tools. Beryllium copper(C1720) alloy sheet of $50{\mu}m$ thickness was chosen for the experiments. The maximum limit drawing ratio of 2.1 was achieved experimentally for the conditions of the blankholder force(BHF)=5.3kgf and Rd=0.3mm. Both thickness and hardness along the central section of drawn cups were measured and compared for different drawing conditions. It was found that the deviation of measured data in the thickness and hardness distribution increases with increasing blankholder force and blank diameter.