• Title/Summary/Keyword: bending test of beam

검색결과 336건 처리시간 0.025초

충전형 합성보와 포밍앵글 기둥 접합부의 내진성능에 대한 실험적 평가 (Experimental Evaluation on Seismic Performance of Filled Composite Beam - to - Forming Angle Composite Column Connections)

  • 김형섭;이경구;구지모
    • 한국지진공학회논문집
    • /
    • 제20권1호
    • /
    • pp.71-77
    • /
    • 2016
  • In this study, the seismic performance of connections between filled composite beam (CG beams) and forming angle composite (FAC) column was experimentally evaluated. First, the bending tests were conducted on two CG beams and the axial tests were conducted on two FAC columns. Then, based on these preliminary test results, the cyclic loading test were performed on two interior connections between CG beam and FAC column. The main difference of two specimens is the plate shape of the CG beam. The test results showed that both specimens achieved the maximum story drift capacity over 0.04 radian which is required for special moment frame.

동전단 마스터곡선을 이용한 아스팔트 바인더의 노화 특성 평가 (Characteristics of Dynamic Shear Modulus Mastercurve of Aged or Unaged Asphalt Binders)

  • 윤태영;함상민;유평준
    • 한국도로학회논문집
    • /
    • 제15권1호
    • /
    • pp.87-94
    • /
    • 2013
  • PURPOSES: To characterize the aging effect on asphalt binder, dynamic shear modulus mastercurve of two typical asphalt binders are developed. METHODS: To develop dynamic shear modulus mastercurve, dynamic shear modulus at high temperature and creep stiffness at low temperature are measured by temperature sweep test and bending beam rheometer test, respectively. RESULTS: It is observed that the aging effect on asphalt binder can be clearly observed from dynamic shear modulus mastercurve and the mastercurve can be utilized to predict behavior of asphalt binder at wide range of temperature. CONCLUSIONS: It is confirmed that SBS 5% modified binder has more desirable mechanical property at low and high temperature as a pavement material comparing to PG64-22 binder and the mastercurve is an effective tool to evaluate the property of asphalt binder.

완전매입형 복합트러스 합성보의 내하력 평가 (The Study on Ultimate Strength of Fully Embedded Composite Truss Beam)

  • 천성봉;원대연;최홍식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.306-309
    • /
    • 2006
  • The fully embedded composite truss beam is developed based on composite member, truss system before composite and beam system after composite. The proper design concept and method of the fully embedded composite truss beam are discussed. A bending test on the fully embedded composite truss beam with span length 25.0m is carried out to investigate the flexural behavior and ultimate strength of the developed structure up to failure. A good agreement between the measured and predicted results are observed.

  • PDF

Bending Creep of Glulam and Bolted Glulam under Changing Relative Humidity

  • PARK, Junchul;SONG, Yojin;HONG, Soonil
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권5호
    • /
    • pp.676-684
    • /
    • 2020
  • This study was carried out in order to evaluate the bending creep deflection of glulams and bolted glulams beam-to-beam connection with steel-gusset plates and bolts under changing relative humidity. The two types of glulam beams (130 mm in width, 175 mm in thickness, and 3000 mm in length) used in this study were made from domestic larch and composed of seven layers. The gussets were made of 8-mm-thick steel plates. Creep testing was conducted under constant loads in an uncontrolled environment. The test was carried out in a room that was well ventilated through a window. The creep test specimens were loaded for 33,000 hours. A bending creep test for the glulams was conducted through four-point loading. The applied stresses were 20% and 30% of the MOR in the static bending test for the glulam and bolted glulam, respectively. After 33,000 hours, the creep deflection of the glulam at a 20% stress level increased by 39% to 99%, while the creep deflection of the glulam at a 30% stress level increased by 27% to 67%, as compared with instantaneous elastic deflection. The relative creep increased during autumn and winter, and recovered during spring and summer. The relative creep of the bolted glulams was changed abruptly by loading up to 5,000 hours, but stabilized after 5,000 hours, and then gradually increased until 33,000 hours. The relative creep of the bolted glulam increased 2.11 times on average after 33,000 hours.

반복하중하의 탄소섬유시트 보강보의 거동에 관한 연구 (A study on the behavior of beam strengthened with CFS under repeated loading)

  • 박정용;정진환;김성도;조백순
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.627-630
    • /
    • 2004
  • This paper investigates a study on the bending behavior of beam strengthened with CFS under repeated loading. The test specimen consisted of 20cm in width, 40cm in depth, and 15cm in CFS width. We find the strength decrease under repeated loading test comparing with the monotonic incremental loading test.

  • PDF

Measuring high speed crack propagation in concrete fracture test using mechanoluminescent material

  • Kim, Wha-Jung;Lee, Jae-Min;Kim, Ji-Sik;Lee, Chang Joon
    • Smart Structures and Systems
    • /
    • 제10권6호
    • /
    • pp.547-555
    • /
    • 2012
  • Measuring crack length in concrete fracture test is not a trivial problem due to high speed crack propagation. In this study, mechanoluminascent (ML) material, which emits visible light under stress condition, was employed to visualize crack propagation during concrete fracture test. Three-point bending test was conducted with a notched concrete beam specimen. The cracking images due to ML phenomenon were recorded by using a high speed camera as a function of time and external loadings. The experimental results successfully demonstrated the capability of ML material as a promising visualization tool for concrete crack propagation. In addition, an interesting cracking behavior of concrete bending fracture was observed in which the crack propagated fast while the load decreased slowly at early fracture stage.

Simulation of crack initiation and propagation in three point bending test using PFC2D

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming;Hedayat, Ahmadreza;Nezamabadi, Maryam Firoozi;Karbala, Mohammadamin
    • Structural Engineering and Mechanics
    • /
    • 제66권4호
    • /
    • pp.453-463
    • /
    • 2018
  • Three points bending flexural test was modelled numerically to study the crack propagation in the pre-cracked beams. The pre-existing double internal cracks inside the beam models were considered to investigate the crack propagation and coalescence paths within the modelled samples. Notch configuration effects on the failure stress were considered too. This numerical analysis shown that the propagation of wing cracks emanating from the tips of the pre-existing internal cracks caused the final breaking of beams specimens. It was also shown that when two notches were overlapped, they both mobilized in the failure process and the failure stress was decreased when the notches were located in centre line. However, the failure stress was increased by increasing the bridge area angle. Finally, it was shown that in all cases, there were good agreements between the discrete element method results and, the other numerical and experimental results. In this research, it is tried to improve the understanding of the crack propagation and crack coalescence phenomena in brittle materials which is of paramount importance in the stability analyses of rock and concrete structures, such as the underground openings, rock slopes and tunnel construction.

Nd:YAG 레이저빔을 이용한 아연도금강판(SECC)과 쾌삭강봉(SUM24L)의 용접에 관한 연구 (Welding behavior between Zn-coated steel plate and free cutting carbon steel rod by Nd:YAG laser beam)

  • 노영태;김병철;김도훈;윤갑식
    • 한국레이저가공학회지
    • /
    • 제4권3호
    • /
    • pp.30-39
    • /
    • 2001
  • This work was tamed out to apply a laser welding technique in joining between a Zn coated low carbon steel plate(SECC) and a free cutting carbon steel shaft(SUM24L) with or without W coating. Experiments were carried out and analysed by applying the FD(factorial design)method to obtain the optimum Laser welding condition. Optical microscopy, SEM, TEM and XRD analyses were performed in order to observe the microstructures in the fusion zone and the HAZ. Mechanical properties of the welded specimens were examined by microhardness test, tensile test and twist test. There was no flawed Zn in the fusion zone by EDS analysis. This means that during the welding process, Zn gas could be eliminated by appropriate shielding gas flow rate and butt welding gap. Ni coating itself did not influence on the tensile strength and hardness. However, twist bending strength and the weld depth of the Ni-coated free cutting carbon steel were lower as compared with those of the uncoated free cutting carbon steel. It was attributed to a lower absorbance of laser beam to the shin Ni surface. According to the results of the factorial design tests, the twist bending strength of welded specimens was primarily affected by pulse width, laser power, frequency and speed.

  • PDF

점탄성층을 삽입한 3층 적층보의 진동감쇠특성에 관한 연구 (A Study on the Characteristics of Vibration Damping of a Beam with Inserted Viscoelastic Layer)

  • 박응순;박세만;박명균;박상규
    • 소음진동
    • /
    • 제7권3호
    • /
    • pp.511-519
    • /
    • 1997
  • For a number of years it has been known that flexural vibration in a beam and plate can be damped by the application of layer of damping (viscoelastic) material that is in turn constrained by a backing layer or foil. In this study, a quantitative analysis of damping of the sandwich beam has been performed by using impact test. The damping is characterized by the loss factor .etha. in which the damping is normalized by imaginary part of the complex bending stiffiness of the beam. Results show that the relative thickness of the sandwich beam gives more effect on the riatural-frequencies and loss factor than the variation of width does. It is also shown that the Ross-Kerwin-Ungar equation and impact test can be effectively used to identify the damping characteristic of the sandwich beam and viscoelastic material.

  • PDF

Stuttgart 콘크리트 보 전단실험의 재해석을 통한 합리적 전단모델 연구 (A Study on the Rational Shear Model by interpretation of Stuttgart Beam Shear Test)

  • 김우;모귀석;정제평
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.884-889
    • /
    • 2003
  • Based on the reinterpretation of the well-known relationship between shear and the rate of change of bending moment in a reinforced concrete beam subject to combined shear and moment loads, the shortcomings of present truss models are discussed. The core of the theory is that a new perspective on the shear strength can be gained by viewing the internal stress filed in terms of the superposition of two base components of shear resistance; arch action and beam action. The arch action can be designed using the simple truss having curved compression chord, while the beam action between the two chords can be modeled using a parallel chord truss with MCFT or RA-STM. The compatibility of deformation associated to the two action is taken into account by employing a characteristic factor a. The new model was examined by the Stuttgart beam shear tests, and the results show that the present approach provides good estimates of stirrup contribution and concrete contributions.

  • PDF