• Title/Summary/Keyword: below

Search Result 16,752, Processing Time 0.042 seconds

Prevalent Characteristics of Fowl Typhoid and Antibiotic Susceptibility of Salmonella gallinarum (닭 티푸스의 발생상황과 Salmonella gallinarum의 항균제 감수성)

  • 박노찬;도재철;조광현;장성준;권헌일;박덕상
    • Korean Journal of Veterinary Service
    • /
    • v.18 no.2
    • /
    • pp.113-123
    • /
    • 1995
  • The present study was conducted to investigate the prevalent characteristics of Fowl Typhoid and antibiotic susceptibility of Salmonella gallinarum isolated from 56 infective or dead chickens of 20 egg laying farms in Kyung Buk province during the period from August to December 1994. 1. Among 416, 000 chickens of 92 flocks in 20 egg laying farms, 17, 360 chickens of 31 flocks were died of Fowl Typhoid. 2. Salmonella gallinarum was isolated from 56 chickens in liver and spleen, and then blood of infective chickens was positive to Pullorum antigen. 3, In the survey of gross lesion of 56 chickens, 43 chickens(76.8%) were swelled at liver, 39(69.6%) were swelled at spleen, 12(21.4%) were changed with bronze, 3(5.4% ) were hemorrhagic in peritoneal cavity. 4. In transmission pattern, 4 farms were outbreaked the entrance of chicken house at first, but the others were outbreaked at various place. They were transmitted at right and left directions in flock. 5. 2 farms confirmed at the early stage of infection were eradicated by removing infective chickens and administrating antibiotics, but 18 farms at chronic stage were not. 6. The biochemical properties of 112 Salmonella gallinarum from chickens were generally identical to those of the referance, but H$_2$S was not productive, cellobiose was fermentive. 7 Minimum inhibitory concentration(MIC) of 20 isolates was performed by using 21 antibiotics, MICs of Amikacin(Ak), Gentamicin(Gm), Kanamycin(Km), and Tetracycline (Tc) were below 1.6 ug/ml, Ampicillin(Am), Furazolidone(Fu) and Neomycin(Nm) were below 3.1 ug/ml, Cephalothin(Ce), Cefazoline(Cf) and Chloramphenicol(Cm) were below 6.3 ug/ml, Nalidixic acid(Na), Polymyxin(Po) and Rifampicin(Rf) were below 12.5 ug/ml, Penicillin (Pm) was below 25 ug/ml, Colistin(Co) and Streptomycin(Sm) were below 50 ug/ml, Sulfamerazine(Sr) and Sulfamethazine (St) were below 200 ug/ml, Lincomycin(Lm) and Spiramycin(Sp) were below 400 ug/ml, Bacitracin(Ba) was below 800 ug/ml. 8. Among the 20 isolates, all(100%) of those were sensitive to Ak, Am, Ce, Cf, Cm, Fu, Gm, Km, Na, Nm, Po, Rf, Sr, St and Tc, but 6 isolates(30%) were resistent to Co, 20(100% ) to Ba, Lm, Pm, Sm, and Sp. The drug resistance patterns were simple which 6 strains were BaCoLmPmSmSp type, and 14 were BaLmPmSmSp type.

  • PDF

Characterization of airborne bioaerosol concentration at the apartment in chungnam area (충남 지역 공동주택의 미생물농도 분포특성에 대한 연구)

  • Son Bu-Soon;Chun Jae-young;Yang Won-ho;Chung Tae-Woong
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.4 s.58
    • /
    • pp.21-30
    • /
    • 2005
  • This research was performed to measure the concentration distribution of bioaerosol in apartment houses in the region of Chungnam (Chunan, Asan) for 1 month, December, 2004. The results are as follows. 1. By using SDA method, the average concentration of total microbe and fungus in the air inside and outside apartment house below 4 years are $69,42cfu/m^3\;and\;15.66cfu/m^3$, while apartment house over 4 years, $214.58cfu/m^3\;and\;216.43cfu/m^3$, respectively With gravitational sedimentation method, the average concentration of total microbe and fungus of apartmenthouse below 4 years are $100.63cfu/m^3\;and\;22.83cfu/m^3$, while apartment house over 4 years, $216.43cfu/m^3\;and\;70.000cfu/m^3$, respectively. 2. The I/O ratio of floating germ of apartment house below 4 years and over 4 years are 2.87 and 5.12 for total microbe, and 3.32 and 8.28 for fungus, respectively. The I/O ratio of falling germ of apartment house below 4 years and over 4 years are 1.55 and 2.81 for total microbe, and 2.85 and 4.08 for fungus, respectively. The apartment house below 4 years shows a low I/O ratio in all cases. 3. The difference in concentration of microbe between inside master bedroom and living room of apartment house below 4 years is $13.183cfu/m^3$, total microbe, and $4.787cfu/m^3$, fungus, while, apartment house over 4 years, $43.531cfu/m^3$, total microbe, and $21.932cfu/m^3$, fungus. The measured differences are statistically significant. 4. Air sampler was used to verify the difference in concentration of microbe with the age of apartment house. The difference in concentration of total microbe and fungus for outside apartment house below 4 years and over 4 years are $49.82cfu/m^3$ and $3.78cfu/m^3$, respectively. The difference of inside living room shows $160.23cfu/m^3$ for total microbe and $28.01cfu/m^3$ for fungus, and the difference of inside master bedroom shows $225.43cfu/m^3$ for total microbe and $56.73cfu/m^3$ for fungus. The differences are statistically significant. The difference in concentration of outside apartment house below 4 years and years 4 years are $34.66cfu/m^3$, total microbe, and $15.66cfu/m^3$, fungus, while inside apartment house below 4 years and over 4 years, $196.93cfu/m^3,\;and\;78.67cfu/m^3$, respectively. The measured differences are statistically significant.

A Comparison of Cardio-Pulmanary Function by the use of a Single Axis Foot and SACH Foot in Below-Knee Amputation (하퇴 절단 환자의 족부 종류에 따른 심폐 기능의 비교)

  • Ahn, Wang-Hun;Kim, Young-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.1
    • /
    • pp.311-319
    • /
    • 2000
  • This study was to measure whether single axis foot or the SACH foot applied to below-knee amputation patients would bring positive changes to the patients' cardiopulmonary function, and help them to overcome their disability. The experiment took place at Asan Medical Center, University of Ulsan, from July 20th to November 20th, 1999 with 10 below-knee amputation patients. The patients were asked to equip single axis foot and SACH foot by turns and lead them to walk on a treadmill which was designed to increase its steep slope. Patients heart rate and blood pressure were recorded before and after their walking, The heart rate, systolic blood pressure, diastolic blood pressure of the patients who were equipped with, either SACH foot or single axis foot, have been increased with as the slant becoming steeper. The heart rates during the experiment did not show relevant changes according to the kind of foot used and the gradient, but the changes occurred before and after the walking(p=0.0001), The similar result of systolic blood pressure was found during the waking(p=0.01). Below-knee amputation patients are expected to walk and perform the routines better, no matter what type of foot is used, as long as they wear an artificial foot properly and taking features of foot product into consideration

  • PDF

Dielectric Properties of Carbon Black-Filled Polyethylene Matrix Composites (카본블랙 충진 Polyethylene Matrix Composites의 유전 특성)

  • Shin, Soon-Gi
    • Korean Journal of Materials Research
    • /
    • v.21 no.4
    • /
    • pp.196-201
    • /
    • 2011
  • It is known that the relative dielectric constant of insulating polyethylene matrix composites with conducting materials (such as carbon black and metal powder) increases as the conducting material content increases below the percolation threshold. Below the percolation threshold, dielectric properties show an ohmic behavior and their value is almost the same as that of the matrix. The change is very small, but its origin is not clear. In this paper, the dielectric properties of carbon black-filled polyethylene matrix composites are studied based on the effect medium approximation theory. Although there is a significant amount of literature on the calculation based on the theory of changing the parameters, an overall discussion taking into account the theory is required in order to explain the dielectric properties of the composites. Changes of dielectric properties and the temperature dependence of dielectric properties of the composites made of carbon particle and polyethylene below the percolation threshold for the volume fraction of carbon black have been discussed based on the theory. Above the percolation threshold, the composites are satisfied with the universal law of conductivity, whereas below the percolation threshold, they give the critical exponent of s = 1 for dielectric constant. The rate at which the percentages of both the dielectric constant and the dielectric loss factor for temperature increases with more volume fraction below the percolation threshold.

RTI Model and Its Applicability in Educational Settings for Students with Achievement of Below Basic Proficiency Level

  • Jun, Myongnam;Kim, Namok;Yang, Myonghee;Kwon, Daehoon;Hong, Daewoo;Choi, Hyeonah
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.79-83
    • /
    • 2015
  • The Response to Intervention(RTI) approaches is the method to help students who are at risk for learning difficulties in advance and provide an appropriate level of intervention. In this article, the characteristics of model RTI were reviewed for students with achievement of below basic proficiency level. We considered RTI as supporting system to document students' progress and its applicability for the general educational setting in Korean school. The tier of RTI make it possible the evidence based individual instruction and counseling, differentiated step-by step approach for students with achievement of below basic proficiency level. In conclusion, RTI can be used as educational tools for dealing with improvement of academic subjects learning, behavioral and emotional problem for students with achievement of below basic proficiency level. For building high quality implementing for RTI it is needed the collaboration of teachers, counselors and learning consultants and related educators.

Shear stresses below the rectangular foundations subjected to biaxial bending

  • Dagdeviren, Ugur
    • Geomechanics and Engineering
    • /
    • v.10 no.2
    • /
    • pp.189-205
    • /
    • 2016
  • Soils are subjected to additional stresses due to the loads transferred by the foundations of the buildings. The distribution of stress in soil has great importance in geotechnical engineering projects such as stress, settlement and liquefaction analyses. The purpose of this study is to examine the shear stresses on horizontal plane below the rectangular foundations subjected to biaxial bending on an elastic soil. In this study, closed-form analytical solutions for shear stresses in x and y directions were obtained from Boussinesq's stress equations. The expressions of analytical solutions were simplified by defining the shear stress influence values ($I_1$, $I_2$, $I_3$), and solution charts were presented for obtaining these values. For some special loading conditions, the expressions for shear stresses in the soil below the corners of a rectangular foundation were also given. In addition, a computer program was developed to calculate the shear stress increment at any point below the rectangular foundations. A numerical example for illustrating the use of the presented solution charts was given and, finally, shear stress isobars were obtained for the same example by a developed computer program. The shear stress expressions obtained in this work can be used to determine monotonic and cyclic behavior of soils below rectangular foundations subjected to biaxial bending.

A study on the Character of Water Quality according to the Flux in Pal-Dang Reservoir (팔당호 유량변동에 따른 수질특성에 관한 연구)

  • 김종민
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.12-24
    • /
    • 1995
  • I tried to evaluate the reason of the monthly variation of water quality according to the hydrologic character of Pal- dang reservoir inflow variation. The result of this study is as below; 1 ) COD, BOD, Total- nitrogen and Total- phosphate concentration increase generally according to the flux and Total- phosphate concentration is the most affected item by flux. 2) COD, BOD, Total- nitrogen and Total- phosphate concentration increase according the flux, but they begin to decrease at the below point ; COD · 1,154 CMS, BOD : 1,007 (CMS cubicmeter per second ) and Inflow- Concentration interrelation formula is as below; table omitted.

  • PDF

The DFM-Aware Design with Statistically-based Approaches in 130nm and below

  • Jung, Won-Young;Kim, Taek-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.22-23
    • /
    • 2008
  • As technology continues to scale down dramatically into 130nm and below, the impacts of process-induced variations on interconnect as well as device become more severe and significant in 130nm and below design. In order to predict changes of circuit characteristics due to process-induced variations accurately and efficiently, the DFM-Aware design environment has been developed and verified.

  • PDF

Relations between Resonance Structures in Photoionization Spectra in Three-Channel-Systems Studied by Multichannel Quantum Defect Theory

  • Lee, Chun-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2168-2176
    • /
    • 2012
  • Relations between fitted parameters for photoionization spectra both below and above the thresholds in the systems involving 3 channels are obtained using phase-shifted version of the multichannel quantum-defect theory. Analytical continuation of the photoionization cross sections in the form of ${\langle}{\sigma}_{below}{\rangle}_{v_{below}}={\sigma}_{above}$ examined using several representations.

The Characteristics of Exhaust Emissions by Durability Test with Biodiesel Fuel (20%) in a Commercial CRDI Diesel Engine (상용 CRDI 디젤기관에서 바이오디젤유 20% 적용시 내구시험에 따른 배기배출물 특성)

  • Choi, Seung-Hun;Oh, Young-Taig
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.379-383
    • /
    • 2008
  • A CRDI diesel engine used to commercial vehicle was fueled with diesel fuel and 20% biodiesel blended fuel (BDF 20%) and tested at the Seoul-10 mode for 150 hours. Engine dynamometer testing was completed at regularly scheduled intervals to monitor the engine performance and exhaust emissions. To check the engine parts (valve, injector), the engine was inspected after 150 hours running test. It was concluded that there was no unusual deterioration of the engine, or the changes in engine power (below 1.9%), smoke (below 4.1%), NOx (below 3.7%) and durability characteristics in spite of operation of 150 hours run with BDF 20%. The difference of kinetic viscosity for engine oil (before and after durability testing) was below 0.19% at $100^{\circ}C$.