• Title/Summary/Keyword: belite cement type

Search Result 13, Processing Time 0.023 seconds

A Study on the Properties of the Confined water ratio for Binder type and Replacement ratio (결합재의 종류 및 치환율에 따른 구속수비의 특성에 관한 연구)

  • Kwon Yeong-Ho;Lee Hyun-Ho;Lee Hwa-Jin;Ha Jae-Dam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.584-587
    • /
    • 2004
  • This research investigates the rheological behavior and the confined water ratio of the cement paste and binder condition in order to predict mix design proportion of the high flowing concrete. The purpose of this study is to determine the optimum replacement ratio of binders including fly ash, and lime stone powder by the cement weight. For this purpose, belite cement, blast furnace slag cement and ordinary portland cement are selected. As test results, the confined water ratio shows the following range ; OPC>blast furnace slag cement>belite cement. Therefore, belite cement is proved very excellent cementitious materials in a view point of the flowability. The optimum replacement ratio of lime stone powder is shown over $30\%$ in case of belite cement and about $10\%$ in case of slag cement type. Also, the optimum replacement ratio of fly ash is shown $30\%$ by the cement weight considering the confined water ratio and deformable coefficient of the paste condition.

  • PDF

An Experimental Study on the Construction Performances and Economical Evaluation of the Self-compacting Concrete by Cementitious Materials (결합재에 따른 자기충전 콘크리트의 시공성 및 경제성 평가에 관한 실험적 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.3
    • /
    • pp.315-322
    • /
    • 2017
  • The purpose of this study is to investigate experimentally the construction performances and economical evaluation of the self-compacting concrete in actual site work after selecting the optimum mix proportions according to cementitious materials. Slag cement type of 46.5% slag powder and belite cement of 51.4% $C_2S$ content, lime stone powder as binders are selected for site experiment including water cement ratio. Also, test items for optimum mix proportion are as followings ; (1) Slump flow, 500 mm reaching time, V-type flowing time and U-box height (2) Setting time, bleeding, shortening depth and adiabatic temperature rising (3) Mixing time in plant (4) Concrete quantity and cost, quality control in actual concrete work. As test results, (4) Optimum water-cement ratio ; Slag cement type 41.0% and belite cement 51.0% (2) Setting time and bleeding finishing time of slag cement are faster, bleeding content of slag cement is higher, shortening depth and adiabatic temperature rising of belite cement type are lower (3) Optimum mixing time in batcher plant is 75 seconds and concrete productive capacity is about $100{\sim}110m^3/hr$. (4) Belite cement type is lower than slag cement type in material cost 14.0%, and concrete quantity in actual concreting work save 3.3% in case of belite cement type. Therefore, self-compacting concrete of belite cement type is definitely superior to that of slag cement type in various test items without compressive strength development.

Synthesis and Hydration of Modified Belite Cement Clinker (Modified Belite Cement Clinker의 합성 및 수화반응)

  • 김창범;한기성;최상흘
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.2
    • /
    • pp.195-200
    • /
    • 1990
  • For the development of low energy cement, the belite cement clinker of calcium sulphoaluminate ferrite type was synthesized at 130$0^{\circ}C$ and containing C2S, C4A3S as the major minerals along with C3A, C4AF, CS by using limestone, dolomite, clay, iron ore, gypsum and alumina as raw materials. At over 130$0^{\circ}C$, C4A3S was decomposed and thus C3A was increased. When hydrated, this cement was hardened, producing ettringite, CSH, etc.

  • PDF

Properties of Belite with Cooling Rate (냉각속도의 변화에 따른 벨라이트의 특성)

  • Kim, Jin-Ho;Park, Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.1
    • /
    • pp.68-73
    • /
    • 2001
  • Active belite cement clinker 합성을 위하여 안정제로 borax (3 wt%)를 사용하였으며, 1300, 1350, 140$0^{\circ}C$에서 소성하고, 각각의 소성온도에서 아세톤 급냉, 공냉, 로냉의 3가지 방법으로 냉각속도를 달리하여 합성하였다. 클링커의 특성분석은 TG-DTA, XRD, FT-IR, SEM-EDS로 조사 분석하였으며, free-CaO 함량은 KSL 5120의 ethylene glycol법으로 정량하였다. Borax(3 wt%)를 첨가한 시료의 시차열분석에서 ${\gamma}$상으로의 전이는 관찰되지 않았으며, 각각의 소성온도와 냉각속도에 따른 free-CaO 분석에서 0.07~0.14%의 범위로 낮게 나타났으며, borax가 첨가되지 않은 시료는 140$0^{\circ}C$에서 소성하고 급냉시켰지만 ${\gamma}$상으로 전이되어 dusting 현상을 나타내었다. Borax(3 wt%) 첨가된 시료의 SEM 미세구조는 140$0^{\circ}C$에서 소성하고 급냉시켰지만 ${\gamma}$상으로 전이되어 dusting 현상을 나타내었다. Borax(3 wt%) 첨가된 시료의 SEM 미세구조는 140$0^{\circ}C$에서 소성된 모든 시료와 135$0^{\circ}C$에서 소성하고 급냉과 공냉시킨 시료는 type I belite, type III belite($\alpha$상) 구조를 나타낸다. 135$0^{\circ}C$에서 소성하고 로냉한 시료와 130$0^{\circ}C$에서 소성된 모든 시료는 type II belite($\beta$상) 구조를 나타내었다.

  • PDF

A study on the quality performances of the high flowing concrete for binder types (분체의 종류에 따른 고유동 콘크리트의 품질성능에 관한 연구)

  • 권영호;이현호;하재담
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.567-572
    • /
    • 2002
  • This research investigates experimentally an effect on the quality performances of the high flowing concrete according to binder types. The purpose of this study is to determine the optimum mix proportion of the high flowing concrete having good flowability, viscosity and no-segregation. For this purpose, two types using belite cement+lime stone powder(LSP) and furnace slag cement+lime stone powder are selected and tested by design factors including water cement ratio, fine and coarse aggregate volume ratio. As test results of this study, the optimum mix proportion for binder types is as followings. 1) One type based belite cement ; water cement ratio $51^{\circ}C$, fine aggregate volume ratio $43^{\circ}C$ and coarse aggregate volume ratio $53^{\circ}C$, replacement ratio of LSP $42.7^{\circ}C$. 2) Another type based slag cement : water cement ratio $41^{\circ}C$, fine aggregate volume ratio $47^{\circ}C$ and coarse aggregate volume ratio $53^{\circ}C$, replacement ratio of LSP $13.5^{\circ}C$.

  • PDF

A Study on the Improvement for Workability of Concrete with Belite Cement (4종(벨라이트)시멘트의유동성 향상에 대한 연구)

  • 하상운;구본창;김동석;하재담;이종열
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.247-250
    • /
    • 2000
  • As construction technology advances, most of concrete structures are becoming larger and taller. Therefore, high strength and high quality concrete is necessary for them. Nowadays, the proposal of using type IV(belite cement) is investigated to satisfy high flowing, low heat, and ho호 strength. In this study, the flow value and compressive strength of mortar were investigated according to usage of AE high range water reducer. And the slump flow value, falling time and heigth difference of concrete with beilte cement and ordinary cement were examined depending on water cement ratio, sand ratio and unit water weigth, and compressive strength to checked depending on age.

  • PDF

Optimum Mix Proportion and Characteristics of the Combined Self Compacting Concrete according to Cement Types (시멘트 종류에 따른 병용계 자기충전 콘크리트의 최적배합비와 특성)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.1
    • /
    • pp.55-64
    • /
    • 2009
  • This study is aimed to derive the optimum mix proportion of the combined self compacting concrete according to cement types (blast-furnace slag cement and belite cement) and to propose the basic data to field construction work after evaluating the quality properties. Specially, lime stone powder (LSP) as binder and viscosity agent are used in the combined self compacting concrete because slurry wall of an underground LNG storage tank should be kept stability of quality during concrete working. Replacement ratio of LSP is determined by confined water ratio test and main design factors including fine aggregate ratio ($S_r$), coarse aggregate ratio ($G_v$) and water-cement ratio (W/C) are selected. Also, quality properties including setting time, bleeding content, shortening depth and hydration heat on the optimum mix proportion of the combined self compacting concrete according to cement type are compared and analyzed. As test results, the optimum mix proportion of the combined self compacting concrete according to cement type is as followings. 1) Slag cement type-replacement ratio of LSP 13.5%, $S_r$ 47% and W/C 41%. 2) Belite cement type-replacement ratio of LSP 42.7%, Sr 43% and W/C 51%. But optimum coarse aggregate ratio is 53% regardless of cement types. Also, as test results regarding setting time, bleeding content, shortening depth and hydration heat of the combined self compacting concrete by cement type, belite cement type is most stable in the quality properties and is to apply the actual construction work.

Corrosion of Steel in Concrete Deteriorated by Freezing/Thawing and Carbonation (동결융해 및 중성화를 받은 콘크리트의 철근 부식 특성)

  • 정해문;김종우;이대근;최광일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.293-298
    • /
    • 1997
  • Corrosion of steel reinforcing in concrete deteriorated by freezing/thawing and carbonation was characterized. Concrete specimens were prepared using various kinds of cements such as ordinary portland cement (type I), low heat portland cement (type IV, belite rich cement), sulphate resistance portland cement (type V), blast furnace slag portland cement and ternary blended cement. Of various cements, type V and type IV with lower $C_3A$ content revealed better steel corrosion resistance after freezing/thawing and carbonation. $C_3A$ content in cement might affect freezing/thawing resistance in sea water.

  • PDF

An Experimental Study on the Rheological Properties of the Combined Self-Compacting Concrete by Quality Variations (품질변동에 따른 병용계 자기충전 콘크리트의 유동특성에 관한 실험적 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.277-285
    • /
    • 2014
  • The purpose of this study is to investigate experimentally the variation factors range having influence on the rheological properties of the combined self-compacting concrete according to materials quality, weighting error and site conditions. Two types cement (blast-furnace slag cement and belite cement), lime stone powder as binder and the optimum mix proportions in the preceded study are selected for this study. Also, variations for sensitivity test are as followings; (1) Concrete temperature 3 cases (2) Surface moisture of sand 5cases (3) Fineness modulus of sand 5cases (4) Specific surface of lime stone powder 3cases (5) Dosage of chemical admixture 5cases. Slump flow ($650{\pm}50mm$), 500 mm reaching time (($7{\pm}3sec$), V-type flowing time ($15{\pm}5sec$) and U-box height (min. 300 mm) are tested for sensitivity. As test results, the variations range for quality control are as followings. (1) Concrete temperature; $10{\sim}20^{\circ}C$(below $30^{\circ}C$) (2) Surface moisture of sand; $base{\pm}0.6%$ (3) Fineness modulus of sand; $2.6{\pm}0.2$ (4) Dosage of chemical admixture; $base{\pm}0.2%$ (5) Specific surface of lime stone powder $6000cm^2/g$. Compared with two types cement including based belite cement (binary type) and based slag cement (ternary type), the combined self-compacting concrete used belite cement type is most stable in the quality control because of high contents for lime stone powder and $C_2S$. It is to propose a control scheme of the combined self-compacting concrete in the actual construction work.

Study on Controlling of Cracks of Concrete Box Culvert in Early Ages (콘크리트 BOX암거 구조물의 초기 균열제어 연구)

  • 이주호;박경래;배한욱;박성규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.731-736
    • /
    • 2001
  • In this thesis, the study on controlling of cracks of concrete box culvert in early ages is presented. The optimum construction method and economical analysis were proposed also through the experiment of the material and field test. As a result of the experiment of the material, using fly ash, CSA expansive agent and BELITE cement(type IV) showed good result in the control of cracks induced by heat of hydration and shrinkage. As a result of construction test analysis, the maintenance time of form system did not show a big difference in controlling of cracks. Control of distribution of reinforcement, spacing of expansion joint and use of BELITE cement showed big differences in the control of cracks in early ages. As a result of economical analysis, control of construction variables before construction can make it possible to reduce the repair expense.

  • PDF