• Title/Summary/Keyword: behavior of pollutants

Search Result 125, Processing Time 0.024 seconds

Analysis of Behavior Characteristics of Water Pollutants in Yeongsan River Using 3D Hydraulic Model (3차원 수리 모델을 이용한 영산강 수질오염물질의 수체 내 거동 특성 분석)

  • Hye Yeon Oh;Eun Jung Kim;Jung Hyun Choi
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.6
    • /
    • pp.439-450
    • /
    • 2023
  • The Yeongsan River, a major water resource for Jeollanam-do, that is adjacent to industrial complexes and agricultural areas, is exposed to water pollution. Therefore, it is necessary to investigate the impact of water pollution incidences and prepare response systems for river environment safety for other water resources in the future. Environmental Fluid Dynamics Code (EFDC) was applied to the mainstream of the Yeongsan River where residential, commercial, and agricultural areas are located to analyze the behavior of pollutants conducting the scenario analysis. Considering the pollutants that affected the study area, two pollutants, oil and benzene, with different physical and chemical characteristics were selected for the analysis. As a result of comparing the actual and simulated values of the water elevation, temperature, and flow rate, it was confirmed that the model adequately reproduced the hydraulic characteristics of the Yeongsan River. The oil flow dynamics showed that an increase in flow rate led to reduction in the maximum height of the slick. Notably, the behavior of the oil was predominantly influenced by the wind conditions. In the case of benzene, lower flow scenarios exhibited decreased arrival times and residence times accompanied by an elevation in the maximum concentration levels. From the results of pollutant behavior in the study area, it is feasible to utilize the section of tributary confluence for collection and the weir area for dilution. This study enhances the understanding of the pollutant's behavior with different characteristics and develops effective control systems tailored to the physicochemical attributes of pollutants.

The Pollution Potential of Animal Production Systems : Origin and Atmospheric Cycling of Their Pollutants (축산환경의 오염 잠재력 : 축산오염 물질의 발생과 대기환경계 순환)

  • 김기현;김동균;윤종만
    • Journal of Animal Environmental Science
    • /
    • v.1 no.2
    • /
    • pp.155-164
    • /
    • 1995
  • Despite considerable progresses made in our understanding of environmental fate of pollutants stemming from animal production systems, relatively little is known about the processes and mechanisms regulating their dispersement (via emission) into and deposition from the earth's atmospheric system. Here we present and summarize up-to-date knowledge on this topic with a main emphasis on their origin, physico-chemical characteristics, and geochemical distribution behavior.

  • PDF

Evaluation of Air Pollution Monitoring Networks in Seoul Metropolitan Area using Multivariate Analysis (다변량분석법을 활용한 수도권지역의 대기오염측정망 평가)

  • Choi, Im-Jo;Jo, Wan-Keun;Sin, Seung-Ho
    • Journal of Environmental Science International
    • /
    • v.25 no.5
    • /
    • pp.673-681
    • /
    • 2016
  • The adequacy of urban air quality monitoring networks in the largest metropolitan city, Seoul was evaluated using multivariate analysis for $SO_2$, $NO_2$, CO, PM10, and $O_3$. Through cluster analysis for 5 air pollutants concentrations, existing monitoring stations are seen to be clustered mostly by geographical locations of the eight zones in Seoul. And the stations included in the same cluster are redundantly monitoring air pollutants exhibiting similar atmospheric behavior, thus it can be seen that they are being operated inefficiently. Because monitoring stations groups representing redudancy were different depending on measurement items and several pollutants are being measured at the same time in each air monitoring station, it is seemed to be not easy to integrate or transmigrate stations. But it may be proposed as follows : the redundant stations can be integrated or transmigrated based on ozone of which measures are increasing in recent years and alternatively the remaining pollutants other than the pollutant exhibiting similar atmospheric behavior with nearby station's can be measured. So it is considered to be able to operate air quality monitoring networks effectively and economically in order to improve air quality.

Behavior of Indoor Organic Pollutants Dissolved into the Ringer's Solution (수액제에 유입되는 실내 유기오염물질의 거동)

  • 김만구;정영림
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.315-322
    • /
    • 1996
  • Recently, hospital acquired infections have an increase interest as a public problems, which are caused of indoor pollutants in hospital. Microorganisms, ethylene oxide, formaldehyde, and anesthetic gases are main hazardous pollutants in hospital. The possible pathways of the infection are a respiratory channel as well as a blood channel. The blood channel is concerned since these pollutants might be dissolved into the Ringer's solution. The objective of this research was to evaluate the removal efficiencies of adsorption trap for formaldehyde and microorganisms as indoor pollutants which permeated into the Ringer's solution. Dissolved formaldehyde in the solution was increased with the injection dose time. The amount of dissolved formaldehyde was 67.5 $\pm$ 9.5% in Ringer's solution when injection dose time was controlled about 7hrs. An adsorption trap was designed for preventing formaldehyde and microorganisms to be permeated into Ringer's solution. The adsorption trap was packed with 0.4g of active carbon (60/80 mesh) in a sterilized plastic tube (7.79 cm length, 0.46 cm i.d.) and both ends were packed with glass wool. Devised infusion set equipped with the adsorption trap showed 99.9% of removal efficiency for formaldehyde. Microorganism numbers detected on sterilized water for injection and 5% dextrose infusion used in the hospital were 2,695 $\times 10^3$ cells/l and 4,190 $\times 10^3$ cells/l, respectively. Removal efficiency by the adsorption trap was 92.3 $\pm$ 8.5% as for microorgnisms.

  • PDF

In situ measurement-based partitioning behavior of perfluoroalkyl acids in the atmosphere

  • Kim, Seung-Kyu;Li, Donghao;Kannan, Kurunthachalam
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.281-289
    • /
    • 2020
  • Environmental fate of ionizable organic pollutants such as perfluoroalkyl acids (PFAAs) are of increasing interest but has not been well understood because of uncertain values for parameters related with atmospheric interphase partitioning behavior. In the present study, not only the values for air-water partition coefficient (KAW) and dissociation constant (pKa) of PFAAs were induced by adjusting to in situ measurements of air-water distribution coefficient between vapor phase and rainwater but also gas-particle partition coefficients were also estimated using three-phase partitioning model of ionizable organic pollutants, in situ measurements of PFAAs in aerosol and air vapor phase, and obtained parameter values. The pKa values of PFAAs we obtained were close to the minimum values suggested in literature except for perfluorooctane sulfonic acids, and COSMOtherm-modeled KAW values were assessed to more appropriate among suggested values. When applying parameter values we obtained, it was predicted that air particle-associated fate and transport of PFAAs could be negligible and PFAAs could distribute ubiquitously along the transection from urban to rural region by pH-dependent phase transfer in air. Our study is expected to have some implications in prediction of the environmental redistribution of other ionizable organic compounds.

Study on Electrochemical Sensing Property of Harbor Pollutants using Viologen Derivative (Viologen 유도체를 이용한 항만오염물질의 전기화학적 센싱 특성 연구)

  • Park, Sang-Hyun;Lee, Dong-Yun;Kwon, Young-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.119-120
    • /
    • 2008
  • In this paper, viologen derivative is used as charge transfer material to develop sensors for detecting the organic pollutants which are the main reason of harbor pollution. We fabricated self-assembled monolayers of viologen derivative on gold electrode of QCM and investigated an electrochemical behavior property. We also determined electrochemical sensing property about environmental pollution materials such as bezene, phosphate and surfactant through quantitative and qualitative analysis of charge transfer using intrinsic property of viologen derivative by temperature and concentration change. From the achieved results, we can apply and develope the detecting sensors for harbor pollutants.

  • PDF

Assessing pollutants' migration through saturated soil column

  • Smita Bhushan Patil;Hemant Sharad Chore;Vishwas Abhimanyu Sawant
    • Membrane and Water Treatment
    • /
    • v.14 no.2
    • /
    • pp.95-106
    • /
    • 2023
  • In the developing country like India, groundwater is the main sources for household, irrigation and industrial use. Its contamination poses hydro-geological and environmental concern. The hazardous waste sites such as landfills can lead to contamination of ground water. The contaminants existing at such sites can eventually find ingress down through the soil and into the groundwater in case of leakage. It is necessary to understand the process of migration of pollutants through sub-surface porous medium for avoiding health risks. On this backdrop, the present paper investigates the behavior of pollutants' migration through porous media. The laboratory experiments were carried out on a soil-column model that represents porous media. Two different types of soils (standard sand and red soil) were considered as the media. Further, two different solutes, i.e., non-reactive and reactive, were used. The experimental results are simulated through numerical modeling. The percentage variation in the experimental and numerical results is found to be in the range of 0.75- 11.23 % and 0.84 - 1.26% in case of standard sand and red soil, respectively. While a close agreement is observed in most of the breakthrough curves obtained experimentally and numerically, good agreement is seen in either result in one case.

Corrosion Behavior of Galvanized Steels with Outdoor Exposure Test in Korea for 36 Months (36개월간 국내 옥외폭로시험에 따른 아연도강의 부식거동)

  • Kim, K.T.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.231-241
    • /
    • 2018
  • Atmospheric corrosion is generally an electrochemical degradation process of metal. It can be caused by various corrosion factors of atmospheric component, weather, and air pollutants. Moisture, particles of sea salts, and sulfur dioxide are major factors in atmospheric corrosion. Galvanizing coating is one of the most efficient ways to protect iron from corrosion by zinc plating on the surface of the iron. Galvanized steels are being widely used in automobiles, building structures, roofing, and other industrial structures due to their high corrosion resistance compared to bare iron. Atmospheric corrosion of galvanized steel has shown complex corrosion behavior depending on coating process, coating thickness, atmospheric environment, and air pollutants. In addition, different types and kinds of corrosion products can be produced depending on the environment. Lifespan of galvanized steels is also affected by the environment. Therefore, the objective of this study was to determine the corrosion behavior of galvanized steel under atmospheric corrosion at six locations in Korea. When the exposure time was increased, content of zinc from GA surface decreased while contents of iron and oxygen tended to increase. On the other hand, content of iron was constant even after 36 months of exposure of GI.