Relations of Safety Factor and Reliability Index for Pile Load Capacity (말뚝 기초지지력에 대한 안전율과 신뢰도지수 평가)

  • Kim, Dae-Ho;Lee, Jun-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.466-475
    • /
    • 2006
  • Reliability analysis between safety factor and reliability index for driven and bored pile load capacity was analyzed in this study. 0.1B, Chin, De Beer, and Davisson's methods were used for determining pile load capacity by using load-settlement curve from pile load test. Each method define ultimate, yield and allowable pile load capacities. LCPC method using CPT results was performed for comparing with results of pile load test. Based on FOSM analysis using load factors, it is obtained that reliability indices for ultimate pile load capacity were higher than those of yield and allowable condition. Present safety factor 2 for yield and allowable load capacities are not enough to satisfy target reliability index $2.0\sim2.5$. However, it is sufficient for ultimate pile load capacity using safety factor 3.

  • PDF

Field trial on the control effect of fipronil bait against German cockroaches

  • Ree Han-Il;Lee In-Yong;Jeon Soung-Hoo;Yong Tai-Soon
    • Parasites, Hosts and Diseases
    • /
    • v.44 no.3
    • /
    • pp.255-257
    • /
    • 2006
  • A field trial on the control effect of fipronil poison bait against German cockroaches (Blatella germanica) was carried out at different restaurant types in Sinchon, Seoul, Republic of Korea. Monitoring was performed applying food baited traps for 2 days per week. Reduction rates of German cockroaches by applying fipronil baits were 90.9% at Korean restaurants, 96.4% at Chinese restaurants, and 89.4% in beer hall kitchens after 4 weeks of the treatment. Overall average of the reduction rate was 93.9%. As the natural reduction rate at untreated restaurants was 11.5% after 4 weeks, a correction of the average reduction rate by applying the Abbot formula was 93.1 %.

An Experimental Study of Sonic/Supersonic Ejector Flows (음속/초음속 이젝터 유동에 관한 실험적 연구)

  • Kim, Hui-Dong;Choe, Bo-Gyu;Gwon, O-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.5
    • /
    • pp.640-647
    • /
    • 2002
  • An experimental investigation or the sonic and supersonic air ejector systems has beer conducted to develop design and prediction programs for practical ejector system. Five different primary nozzles have been employed to operate the ejector systems in the ranges of low and moderate operating pressure ratios. The ejector operating pressure ratio for the secondary chamber pressure to be minimized has a strong influence of the ejector throat ratio. The pressure inside the ejector diffuser is not dependent on the primary nozzle configurations employed but only a function of the ejector operating pressure ratio. Experimental results show that a supersonic ejector system is more desirable for obtaining high vacuum pressure of the secondary chamber than a sonic ejector system.

Spectrophotometric Study on the Complex of the Copper by 8-(p-Ethylbenzenesulfonamido) quinoline (분광광도법에 의한 8-(p-Ethylbenzenesulfonamido) quinoline과 구리와의 착물에 관한 연구)

  • Heung Lark Lee;Yung Kyu Park;Chul Heui Lee
    • Journal of the Korean Chemical Society
    • /
    • v.15 no.6
    • /
    • pp.378-384
    • /
    • 1971
  • A new analytical reagent 8-(p-ethylbenzenesulfonamido)quinoline(EBSQ) has been synthesized, and identified its structure. EBSQ forms copper chloroform-soluble complex in a basic solution (pH = 7.5∼10.5). The other optimum conditions for the spectrophotometric study of Cu-EBSQ have been established at 380 $m{\mu}$. Beer's law is followed in the concentration range of 0~44.5 ${\mu}g$ per 10 ml of chloroform. The composition of complex has been found to be $Cu(EBSQ-H)_2$and the over-all instability constant is calculated to be $1.22{\times}10^{-7}$. The absorption coefficient of the $Cu(EBSQ-H)_2$ complex is ${\varepsilon}$ = 15,800.

  • PDF

NDIR Multi-Gas Measurement System for Air Quality based on Wireless Sensor Network (무선센서네트워크 기반 공기질 측정을 위한 비분산적외선 복합가스측정시스템)

  • Paik, Seung Hyun;Lee, Jun Yeong;Jung, Sang Woo;Park, Hong Bae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.5
    • /
    • pp.299-304
    • /
    • 2016
  • As public interest in air quality and environment problem is increasing, many researches are being carried out the gas measurement system. Especially, Non-dispersive infrared (NDIR) measurements using Beer-Lambert gas sensing principle with very high selectivity and long life time are noted for reliable method. It is possible to detect various gases such as carbon dioxide (CO2), carbon monoxide (CO), and nitrogen dioxide (NO2), but many researches are mostly concentrated on CO2 sensor. The multi-gas measuring instrument is high price and unwieldy, therefore it is not suitable for wide area required numerous instrument. So we study the NDIR multi-gas measurement system for air quality based on wireless sensor network, and experiment the realized measurement system.

Spectrophotometric Determination of Ion Pair Extraction of Quaternary Amines with Metanil Yellow (Metanil Yellow에 의한 4급 Amine류의 Ino Pair 추출 흡광도 정량 (II) - Benzalkonium Chloride, Cetylpyridinium Chloride 및 Dimenhydrinate의 정량)

  • 김영수;최종환
    • YAKHAK HOEJI
    • /
    • v.35 no.1
    • /
    • pp.15-21
    • /
    • 1991
  • Quaternary amines which are widely used as medicines are nitrogen compounds. Metanil yellow(MY) and benzalkonium chloride(BKC) were mixed and added to 10ml of the buffer solution and then the solution was shaken for 5 minutes. The maximum absorption wavelength of the reaction product was 402 nm. Dichloromethane was the best extracting solvent among the several organic solvents and the most suitable pH range was 2~8. When the BKC-MY calibration curve was made in the best experimental condition, the Lambert-Beer's law was obeyed in the range of BKC concentration of 2$\times$$10^{-6}$~9$\times$$10^{-6}$M by UV spectrophotometer. This method was possible to determine quaternary ammonium salts in the pharmaceutical preparation.

  • PDF

Normalization and Search of the UV/VIS Spectra Measured from TLC/HPTLC (TLC/HPTLC에서 측정된 자외/가시부 스펙트럼의 표준화 및 검색)

  • Kang, Jong-Seong
    • YAKHAK HOEJI
    • /
    • v.38 no.4
    • /
    • pp.366-371
    • /
    • 1994
  • To improve the identification power of TLC/HPTLC the in situ reflectance spectra obtained directly from plates with commercial scanner are used. The spectrum normalization should be carried out prior to comparing and searching the spectra from library for the identification of compounds. Because the reflectance does not obey the Lambert-Beer's law, there arise some problems in normalization. These problems could be solved to some extent by normalizing the spectra with regression methods. The spectra are manipulated with the regression function of a curve obtained from the correlation plot. When the parabola was used as the manipulating function, the spectra were identified with the accuracy of 97% and this result was better than that of conventionally used the point and area normalization method.

  • PDF

NUMERICAL METHOD FOR THE ASTRONOMICAL ALMANAC AND ORBIT CALCULATIONS (천체력 및 궤도 계산법)

  • Kim, Gap-Seong
    • Publications of The Korean Astronomical Society
    • /
    • v.8 no.1
    • /
    • pp.137-151
    • /
    • 1993
  • We have calculated the astronomical almanac 1994 and simulated the trajectory of a satellite orbit considering all perturbative forces with various initial conditions. In this work, Gauss Jackson multistep integration method has been used to calculate our basic equation of motion with high numerical accuracy. It has beer. found that our results agree well with the Astronomical Almanac Data distributed by JPL of NASA and the orbit simulations have been carried out with fast speed, stability and excellent round-off error accumulation, comparing with other numerical methods. In order to be carried out our works on almanac and orbit calculations easily by anyone who uses a personal computer, we have made a computer program on graphical user interface to provide various menus for detail works selected by a mouse.

  • PDF

Production of Brewer's Yeast Extract by Enzymatic Method (효소 분해법에 의한 맥주효모 추출물의 제조)

  • 이시경;박경호;백운화;유주현
    • Microbiology and Biotechnology Letters
    • /
    • v.21 no.3
    • /
    • pp.276-280
    • /
    • 1993
  • Cell lytic enzyme, 5'-phosphodiesterase, and AMP-deaminase were used to produce yeast extract as a natural seasoning from beer yeast cells. Prior to the addition of cell lytic enzyme, heat treatment was performed to increase the cell wall degradation` the optimum condition of the cell lytic enzyme was 50C at pH 7.0. The production yields by the enzymatic method and conventional autolysis method were 42% and 35%, respectively. The total quantity of 5'-nucleotides, GMP and IMP, produced by enzymatic method was increased by 45% than that by the conventional method. Futhermore, the operation time of enzymatic method was only 6.5 hrs, significantly reduced from 24 hrs of the conventional method.

  • PDF

Spectrophotometric Determination of Nickel in Steel with Di-2-pyridylmethanone 2-Thiophenecarboxylic Hydrazone

  • Nakanishi, Tsutomu
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.469-475
    • /
    • 1995
  • Di-2-pyridylmethanon 2-thiophenecarboxylie hydrazone(DPMTCH) was synthesized and used as a chromogenic reagent in the spectrophotometric determination of nickel in steel. The proton disc spectrophotometrically, were $pK_{a1}= 2.66$ and $pK_{a2}= 10.98$ ${\mu}=0.5(NaCl)$. Nickel(II) reacts with DPMTCH to form a 1:2 metal-2-ligand ratio complex, the xylene solution of which has an absorption maximum at 417 nm. Beer's law is obeyed over the range $0-1.17\;mg\;ml^{-1}$ of nickel(II). The molar absorptivity of the nickel(II) complex is $4.17{\times}10^4l\;mol^{-1}\;cm^{-1}$. The precision of the method was estimated for 4.7 mg of nickel(II), the coefficient of variation for 15 replicate determinations being 0.34%.