• Title/Summary/Keyword: bed change

Search Result 677, Processing Time 0.027 seconds

Enhancement of Surface Hardness of Zirconia Ceramics by Hydroxyapatite Powder Bed Sintering (Hydroxyapatite 분위기 소결을 통한 지르코니아 표면 경도 강화)

  • Choi, Min-Geun;Lim, Ji-Ho;Kong, Kyu-Hwan;Jeong, Dae-Yong;Lee, Wonjoo;Li, Long-Hao;Kong, Young-Min
    • Korean Journal of Materials Research
    • /
    • v.24 no.12
    • /
    • pp.677-681
    • /
    • 2014
  • To increase the mechanical property of zirconia, we have investigated the phase change and the resulting hardness of zirconia ceramics by hydroxyapatite (HA) powder bed sintering. It was observed using X-ray diffraction that the cubic zirconia phase, which has a higher hardness value than that of the tetragonal phase, was obtained at the surface of 3 mol% $Y_2O_3$ doped tetragonal zirconia polycrystal (3Y-TZP) ceramics during the sintering process; in our experimental conditions, the phase change at the surface increased as the sintering time increased. We believe that the observed crystalline phase change originated from the decomposition of HA and the diffusion of CaO, as follows. CaO, which was derived from the decomposition of HA at high temperature ($1400^{\circ}C$), diffused into the surface of 3Y-TZP and acted as a stabilizer. As a result, the Vickers hardness value of the treated specimens was higher than that of the non-treated specimen due to the formation of the cubic phase on the surface of 3Y-TZP.

Light environment and physiological response of Panax ginseng I. Experience on light in natural habitat,through cultivation under forest and artificial shade, and change of light control technique (인삼의 광환경과 생리반응 I.자생지. 임간 및 일복 재배에서 광경험과 광조절 방법의 변천)

  • Park, Hoon
    • Journal of Ginseng Research
    • /
    • v.7 no.2
    • /
    • pp.172-192
    • /
    • 1983
  • Light environment and growth of Panax ginseng In habitat and cultivation under natural shade were renewed. Grower's experiences on ginseng stand In relation to light environment were assessed. Change of shading method and grower's concepts on light requirement of ginseng plant in Korea, Manchuria and Japan was counted. Growth of wild ginseng was better under rich light. Optimum crown density index appeared to be 0.7 In natural habitat and 0.4 to 0.7 for the cultivation in forest. Change of light Intensity in forest was greatest in May and reached near to constant value (from 40% to 3% for broad leaf deciduous forest and loom 4% to 2% for pine forest). Insufficient light condition induced long and thin stem, poor flowering and seed bearing, and sequent dormancy. Relation between light and ginseng strand was not clear but light Interception with cool weather was effective. Topography and orientation of bed have been deeply considered for light environment. Panel or bark of won were used for shading in deep forest manly In Manchuria while reed blind and straw thatch were used in Korea. Kinds and number of shades material and seasonal or daily schedule have been simplified probably by labor pressure due to eulargement of plantation. Post height has been greater while width of roof, bed and ditch has changed lisle. Scientific survey in the past omitted important light control methods (complete light hardening etc) which has been practiced in specific areas. The concept and technique of light control in the past in Korea were delicate and intensive including the control of temperature and moisture. For the application of old concept in modem cultivation precise Investigation of the technique including the measurement of light, temperature and moisture is needed.

  • PDF

A Study on the Room Conversion Type when Converting a Patient Bed-Room into a Negative Pressure Isolation Room - Focused on Nationally designated Isolation Wards and Urgent Isolation Wards (일반병실을 음압격리병실로 전환 시 병실 전환 방식에 관한 연구 - 국가지정입원치료병상과 긴급치료병상을 중심으로)

  • Kim, Jiyoon;Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.4
    • /
    • pp.29-35
    • /
    • 2023
  • Purpose: The 2015 Middle East Respiratory Syndrome (MERS) outbreak and the recent COVID-19 pandemic have highlighted the lack of negative pressure isolation rooms and the fragility of the healthcare system. The need for healthcare facility transformation for respiratory infectious diseases has become more prominent due to COVID-19, and the purpose of this study is to provide a foundation for the rapid, economical, and safe construction of negative pressure isolation wards. Methods: This study analyzes the current status of hospitals that have been converted to negative pressure isolation rooms, and provides architectural plans and examples to provide a reference for bedroom change. Research data of this study have been obtained by analyzing the drawings of negative pressure isolation wards of nationally designated inpatient treatment beds and urgent isolation beds. In addition, the relevant literature of urgent isolation beds has been analyzed to derive bedroom change type. Result: In this study, a total of 21 isolation bed conversion methods have been presented. Implications: In order to change efficiently from a general ward to an isolation ward, it is necessary to consider the actual hospital's infectious disease transmission patterns and facility conditions.

A Study of Aerodynamical Effects on the Distance between Track Center of High Speed Train(I) (고속철도 선로중심 간격에 끼치는 공력 영향에 관한 연구(I))

  • Nam, Seong-Won;Kwon, Hyeok-Bin
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.129-134
    • /
    • 2007
  • When constructing a high-speed railroad, the reduction of the distance between track centers and the width of track bed may bring about the effect of cost savings. When, however, considering the influence that the increase of wind pressure due to the change of the distance between track centers may have on the stability of train operation, extensive technical review and overall studies need to be performed before the distance between track centers is determined. Therefore, in this study, the impact that the increase in wind pressure due to the change of aerodynamic phenomena with the change of the distance between track centers may have on two trains passing by each other was predicted, and the stability of train operation was analyzed in order to review the distance between track centers suitable to Honam HSR trains. In this study, we estimated the aerodynamical effects by the results of the real train experiments.

  • PDF

Comparison of Silver-containing Hydrofiber Dressing and Hydrophobic Dressing for Effects on MRSA-infected Full Thickness Skin Defect in the Rat (MRSA에 감염된 흰쥐의 전층피부결손에 대한 은 함유 하이드로화이버 드레싱과 소수성 드레싱의 효과의 비교)

  • Lee, Hun-Joo;Kang, So-Ra;Kim, Yang-Woo
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.359-368
    • /
    • 2011
  • Purpose: Aquacel Ag$^{(R)}$ is a hydrofiber wound dressing integrated with ionic silver. Sorbact$^{(R)}$ is a hydrophobiccoated dressing that uses the hydrophobic interaction with microbes. In this study, we compared the wound healing effects and the antibacterial effects of Medifoam$^{(R)}$, Betadine soaked, Aquacel Ag$^{(R)}$ and Sorbact$^{(R)}$ dressings against MRSA-infected wounds. Methods: Eighty rats were divided into four groups: Medifoam$^{(R)}$; Betadine soaked; Aquacel Ag$^{(R)}$; and Sorbact$^{(R)}$. A $1.5{\times}1.5cm$ square full-thickness wound was made on the dorsum of each rat and infected with MRSA. Twenty-four hours thereafter, each dressing was applied to the wound and changed every other day. One, 3, 7, 11 and 15 days after the wound infection, swab culture grade, wound bed appearance score, and wound defect size change were evaluated, and 7 and 15 days after, histologic evaluation was compared between the groups. Results: The bacteria load of wounds in the Sorbact$^{(R)}$ group decreased earlier than in the other groups. The wound bed appearance score of the Sorbact$^{(R)}$ group also increased quicker, compared with the other groups. However, the size of wounds of the Aquacel Ag$^{(R)}$ group decreased more rapidly, compared with other groups. From the histologic point of view, there was no significant difference between Betadine soaked, Aquacel Ag$^{(R)}$ and Sorbact groups. Conclusion: The hydrophobic dressing using Sorbact$^{(R)}$ showed a more rapid reduction in the MRSA load and an elevation in the wound bed appearance score, but a slower decrease in wound size change due to detachment of wound bed tissue when the dressing was eliminated in the low exudate wound. The silver-containing hydrofiber dressing using Aquacel Ag$^{(R)}$ was more effective in ultimate wound size reduction, but some debris was trapped in the wound tissue and induced foreign body reaction in the high exudate wound. Thus, ongoing selection process of treatment based on the evaluation of the infectious wound state will be very important.

Study on Characteristics for Local Deposit of Sediment by Surveying River Bed's Layer History in High Berm of River Channel (하도 층구조 이력조사를 통한 하도내 국지퇴적 특성 분석)

  • Ryu, Young-Hoon;Lee, Sam-Hee;Ahn, Won-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.10
    • /
    • pp.883-891
    • /
    • 2010
  • More recently, there have been significant changes in the forms of channels due to runoff characteristics driven by climate changes and other alterations in basin/channel environments. Particularly, increasing local deposition in major channels is being observed nationwide. Of such phenomena, it is noteworthy that flood-plains show unidirectional growth and lowering of channels within compound channels in the form of a high-flow plain. These changes are supposed to affect management of the river ecology as well as flood control. In this study, the research on channels in Korea confirmed that the phenomenon of local deposition in those channels is actually taking place, rendering a problem to be urgently addressed. Previous studies on bed changes have been focused on low channels based on bed materials distributed over the channels. However, this research has proved that surface-layer deposition of a high-flow plain is closely related with changes in the conditions of ground surfaces and, ultimately, affects the bed of the entire channel as well. According to the intensive research on the condition of the high-flow plain of the mouth of the Han River, the silt deposited in the high-flow plain was the main cause of settlement/growth of vegetation. And this leads to landforming along with woods-forming, disturbing flood control as well as the normal river ecology.

An application of image processing technique for bed materials analysis in gravel bed stream: focusing Namgang (자갈하천의 하상재료분석을 위한 화상해석법 적용: 남강을 중심으로)

  • Kim, Ki Heung;Jung, Hea Reyn
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.8
    • /
    • pp.655-664
    • /
    • 2018
  • The riverbed material survey is to investigate the particle size distribution, specific gravity, porosity, etc. as basic data necessary for river channel plan such as calculation of sediment transport and change of river bed. In principle, the survey spots are 1 km interval in the longitudinal direction of the river and 3 points or more in the 1 cross section. Therefore, depending on longitudinal length of the river to be investigated, the number of surveyed sites is very large, and the time and cost for the investigation are correspondingly required. This study is to compare the particle size analysis method with the volumetric method and the image analysis method in work efficiency and cost and to examine the applicability of the image analysis method. It was confirmed that the diameter of the equivalent circle converted by the image analysis method can be applied to the analysis of bed material particle size. In the gravel stream with a particle size of less than 10 cm and a large shape factor, the analytical result of the bed material by the image analysis method is accurate. However, when the shape factor decreases as the particle size increases, the error increases. In addition, analysis results of the work efficiency and cost of the volume method and the image analysis method showed a reduction of about 80%.

Vertical Flow Zeolite-Filled Reed Bed with Intermittent Feeding for Sewage Treatment (수직 흐름 제올라이트 갈대 여과상에 의한 생활하수 처리)

  • Seo, Jeoung-Yoon
    • KSBB Journal
    • /
    • v.22 no.2
    • /
    • pp.102-108
    • /
    • 2007
  • A sewage was treated using a vertical flow zeolite-filled reed bed. The sewage from the student dormitory of Changwon National University was fed into the reed bed for 10 minutes every 6 hours at the hydraulic load of $314L/m^3{\cdot}$day. The filtering height of the reed bed was 100 em and the zeolite mixture was filled in the reed bed. The mixture consisted of the same volume of two types of zeolite: 0.5$\sim$1 mm and 1$\sim$3 mm in diameter. Annual average removal efficiency was 88 89.9%, $COD_{Cr}$ 86.1 %, $COD_{Mn}$ 81.2%, T-N 34.0%, $NH_4^+$-N 97.3% and T-P 34.6%. T-N of effluent was mostly $NO_3^-$-N and the concentration of $NO_2^-$-N in effluent was lower than 0.1 mg/L. All removal efficiencies did not show a remarkable seasonal change. The ranking of phosphorous fractions fixed to the zeolite in column test was Ca-P > Fe-P > reductant soluble Fe-P > occluded P > saloid P > AI-P at all depths of the filter. All phosphorous fractions except for AI-P reduced at deeper filter layer, while their content ratios increased at deeper filter layer. Organic matter content was the highest at the highest layer (0$\sim$5 cm from the top of the filter) and only small differences were observed at the deeper filter layer than 5 em from the top. Organic matter content increased at all depths of the filter with the operating time.

Air-staging Effect for NOx Reduction in Circulating Fluidized Bed Combustion of Domestic Unused Biomass (국내 미이용 바이오매스 순환유동층 연소에서 NOx 저감을 위한 air-staging 효과)

  • Yoon, Sang-Hee;Beak, Geon-Uk;Moon, Ji-Hong;Jo, Sung-Ho;Park, Sung-Jin;Kim, Jae-Young;Seo, Myung-Won;Yoon, Sang-Jun;Yoon, Sung-Min;Lee, Jae-Goo;Kim, Joo-Sik;Mun, Tae-Young
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.127-137
    • /
    • 2021
  • Air emission charge for nitrogen oxide as a precursor of fine dust has been introduced and implemented within the country from 2020. Therefore, the development of economical combustion technology for NOx reduction has got more needed urgently. This study investigated the air-staging effect as a way to reduce the NOx during combustion of domestic unused forest biomass, recently possible to secure REC (Renewable Energy Certification) as a substitute for overseas wood pellets in a 0.1 MWth circulating fluidized bed combustion test-rig. Operating conditions were comparison with and without air-staging, the supply position of tertiary air (6.4 m, 8.1 m, 9.4 m in the combustor) and variation of air-staging ratio (Primary air:Secondary air:Tertiary air=91%:9%:0%, 82%:9%:9%, 73%:9%:18%). NO and CO concentrations in flue gas, profiles of temperature and pressure at the height of the combustion, unburned carbon in sampled fly ash and combustion efficiency on operating conditions were evaluated. As notable results, NO concentration with air-staging application under tertiary air supply at 9.4 m in the combustor reduced 100.7 ppm compared to 148.8 ppm without air-staging while, CO concentration increased from 52.2 ppm without air-staging to 99.8 ppm with air-staging. However, among air-staging runs, when tertiary air supply amount at 6.4 m in the combustor increased by air-staging ratio (Primary air:Secondary air:Tertiary air=73%:9%:18%), NO and CO concentrations decreased the lowest 90.8 ppm and 66.1 ppm, respectively. Furthermore, combustion efficiency at this condition was improved to 99.3%, higher than that (98.3%) of run without air-staging.

Detection of Abnormal Area of Ground in Urban Area by Rectification of Ground Penetrating Radar Signal (지하투과레이더 신호의 보정을 통한 도심지 내 지반 이상구간의 검측)

  • Kang, Seonghun;Lee, Jong-Sub;Lee, Sung Jin;Lee, Jin Wook;Hong, Won-Taek
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.217-231
    • /
    • 2017
  • The subsidence of ground in urban area can be caused by the occurrence of the cavity and the change in ground volumetric water content. The objective of this study is the detection of abnormal area of ground in urban area where the cavity or the change in ground volumetric water content is occurred by the ground penetrating radar signal. GPR survey is carried out on the test bed with a circular buried object. From the GPR survey, the signals filtered by the bandpass filtering are measured, and the methods consisting of gain function, time zero, background removal, deconvolution and display gain are applied to the filtered signals. As a result of application of the signal processing methods, the polarity of signal corresponds with the relation of electrical impedance of the cavity and the ground in test bed. In addition, the relative permittivity calculated by GPR signal is compared with that of predicted by volumetric water content of the test bed. The relative permittivities obtained from two different methods show similar values. Therefore, the abnormal area where the change in ground volumetric water content is occurred can be detected from the results of the GPR survey in case the depth of underground utilities is known. Signal processing methods and estimation of relative permittivity performed in this study may be effectively used to detect the abnormal area of ground in urban area.