• 제목/요약/키워드: bearing wall system

검색결과 112건 처리시간 0.023초

장스팬이 가능한 친환경 공동주택용 철골 프리캐스트 합성보 개발 (Development of Long-Span Steel-Precast Composite Beam for Green Apartment Building)

  • 윤태호;홍원기;박선치;윤대영
    • KIEAE Journal
    • /
    • 제11권1호
    • /
    • pp.9-14
    • /
    • 2011
  • Currently, the multi-residential apartments used in Korea are mostly bearing wall apartments which don't satisfy consumers for the lack of architectural plan flexibility. And due to remodelling-incompatible, bearing wall apartments have to be reconstructed. It is, thus, necessary to develop multi-residential apartments utilizing composite beam that can replace the conventional bearing wall-type apartment buildings. Composite beams proposed in this paper ensure modification of space and quality control, while the floor heights are maintained at the same floor height as in bearing wall structures. This study analyzes the experimental behavior of composite beams with proper combination of structural steel, reinforced concrete, and precast concrete. By comparing with the theoretical analysis and experimental results, the accuracy of flexural moment capacity and neutral axis was evaluated. The experiments were performed by two simply-supported specimens using loading and unloading. When the analysis results were compared with the experimental results, the flexural moment capacity of the composite beam was shown with an error of approximately -0.5 to 0.1% at the maximum load limit state.

BIM 기반 형상코드를 이용한 내력벽 철근길이 자동 산정 기초 연구 (A Basic Study of Automatic Rebar Length Estimate Algorithm of Bearing Wall by Using BIM-Based Shape Codes Built in Revit)

  • 임지영;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.79-80
    • /
    • 2023
  • Reinforced concrete structures require large amounts of concrete and rebar in the construction stage. Rebar is a major resource for reinforced concrete structures, and generates more CO2 per unit weight than other materials. To solve this problem, it was confirmed that the cutting waste can be close to zero when the special length of the rebar is calculated in the drawing created after structural design. However, a system for automatically calculating the length of reinforcing bars to efficiently calculate the total amount of reinforcing bars has not been established. Therefore, the objective of this study is a basic study of automatic rebar length estimate algorithm of bearing wall by using BIM-based shape codes built in Revit. The bearing wall rebar can be automatically derived using the developed model. Furthermore, through applying the developed model to the construction field, it will greatly contribute to reducing greenhouse gas emissions by reducing rebar cutting waste.

  • PDF

Seismic base isolation of precast wall system using high damping rubber bearing

  • Tiong, Patrick L.Y.;Adnan, Azlan;Rahman, Ahmad B.A.;Mirasa, Abdul K.
    • Earthquakes and Structures
    • /
    • 제7권6호
    • /
    • pp.1141-1169
    • /
    • 2014
  • This study is aimed to investigate the seismic performance of low-rise precast wall system with base isolation. Three types of High Damping Rubber Bearing (HDRB) were designed to provide effective isolation period of 2.5 s for three different kinds of structure in terms of vertical loading. The real size HDRB was manufactured and tested to obtain the characteristic stiffness as well as damping ratio. In the vertical stiffness test, it was revealed that the HDRB was not an ideal selection to be used in isolating lightweight structure. Time history analysis using 33 real earthquake records classified with respective peak ground acceleration-to-velocity (a/v) ratio was performed for the remaining two types of HDRB with relatively higher vertical loading. HDRB was observed to show significant reduction in terms of base shear and floor acceleration demand in ground excitations having a/v ratio above $0.5g/ms^{-1}$, very much lower than the current classification of $0.8g/ms^{-1}$. In addition, this study also revealed that increasing the damping ratio of base isolation system did not guarantee better seismic performance particularly in isolation of lightweight structure or when the ground excitation was having lower a/v ratio.

오픈 하우징을 촉진하는 제도적 요인 연구;주택의 제도변화를 중심으로 (A Study on the Regulation system factor for facilitating Open Housing;Focused on the system change on the Housing field)

  • 김수암;이성옥;이보라;황은경;임석호
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.227-230
    • /
    • 2006
  • Recently, housing market & circumstances considering society change have changed dramatically. Such changes have affected system exchange of apartment housing greatly and promoted new housing system breaking with bearing wall structure. From this point of view, this study examined ultimate systematic items for promoting better housing system after extracting existing building regulation and housing regulation. This study only analyzed system change considering skeleton(support) with housing regulation, building regulation and fire service law. Consequently, apartment housing will intend residential open building breaking with existing bearing wall structure by promoting change of skeleton & infill system afterward.

  • PDF

Behaviour factor and displacement estimation of low-ductility precast wall system under seismic actions

  • Tiong, Patrick L.Y.;Adnan, Azlan;Hamid, Nor H.A.
    • Earthquakes and Structures
    • /
    • 제5권6호
    • /
    • pp.625-655
    • /
    • 2013
  • This paper investigated the seismic behaviour of an innovated non-ductile precast concrete wall structural system; namely HC Precast System (HCPS). The system comprises load-bearing precast wall panels merely connected only to column at both ends. Such study is needed because there is limited research information available in design codes for such structure particularly in regions having low to moderate seismicity threats. Experimentally calibrated numerical model of the wall system was used to carry out nonlinear pushover analyses with various types of lateral loading patterns. Effects of laterally applied single point load (SPL), uniformly distributed load (UDL), modal distributed load (MDL) and triangular distributed load (TDL) onto global behaviour of HCPS were identified. Discussion was focused on structural performance such as ductility, deformability, and effective stiffness of the wall system. Thus, a new method for engineers to estimate the nonlinear deformation of HCPS through linear analysis was proposed.

조경블록(그린스톤)을 이용한 방음벽 구조설계시스템 (Structure Design System of Soundproofing Wall Using Green Stone)

  • 한중근;한승호
    • 한국환경복원기술학회지
    • /
    • 제3권4호
    • /
    • pp.1-10
    • /
    • 2000
  • This study aims at the new design system development of landscape architecture structures, as soundproof wall using reinforced soil block. This structures, that is new soundproof wall system, have to be maintained stability on acting critical wind load, which is combined exist soundproof wall system and soundproof wall system using environmental green stone block. To the harmony of this system, the post block, so-called landscape block or cast block, is manufactured. It's possible to stand of the post bearing system combined with post-pile and post block. Through the comparison with a serious code for the acting wind load on the soundproof wall, the reasonable wind load could be calculated. Also, the mechanical stability on the green stone block was checked by the Lab. tests based on the UBC (Uniformed Building Code). Because the critical height of soundproof wall system using green stone generally was restricted, the new system demands to combination of the exist system and the new system. For the stability analysis of them, the utility program, SAP2000, was used. And, a semi-auto program on the design system of the new soundproof wall using green stone was developed, which can be easily use because of the simplification.

  • PDF

The Steel Coupling Beam-Wall Connections Strength

  • 박완신;윤현도
    • 콘크리트학회논문집
    • /
    • 제18권1호
    • /
    • pp.135-145
    • /
    • 2006
  • In high multistory reinforced concrete buildings, coupled shear walls can provide an efficient structural system to resist horizontal force due to wind and seismic effects. Coupled shear walls are usually built over the whole height of the building and re laid out either as a series of walls coupled by beams and/or slabs or a central core structure with openings to accommodate doors, elevators walls, windows and corridors. A number of recent studies have focused on examining the seismic response of concrete, steel, and composite coupling beams. However, since no specific equations are available for computing the bearing strength of steel coupling beam-wall connections, it is necessary to develop such strength equations. There were carried out analytical and experimental studies to develop the strength equations of steel coupling beam-connections. Experiments were conducted to determine the factors influencing the bearing strength of the steel coupling beam-wall connection. The results of the proposed equations were in good agreement with both test results and other test data from the literature. Finally, this paper provides background for design guidelines that include a design model to calculate the bearing strength of steel coupling beam-wall connections.

벽식구조 거푸집 공사를 위한 일체식 거푸집 조립 신공법 개발에 관한 연구 (A Study on the Development of a Construction Method for Monolithic Formwork Assembly Method in the Bearing Wall System)

  • 강병국;강인석;이한승;오원희;신재삼;이주호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.622-625
    • /
    • 2006
  • This Study is the consideration for new formwork assembly method in Bearing Wall System. It is consisted of two parts. one is researched into an ordinary formwork system and suggested a new formwork system. The other makes an investigation into the resisting capacity of proposed method by experimental and field test. For the application of this method to the field, it is expected to improve workability and safety, and to reduce the loss of labor.

  • PDF

아파트 내부 공간 구성 요소에 의한 디자인 시스템에 관한 연구 (Study on the Design System based on the Interior Space Composition Factors of Apartment Housing)

  • 정재욱;윤미라
    • 한국실내디자인학회논문집
    • /
    • 제27호
    • /
    • pp.35-42
    • /
    • 2001
  • The main scope of this study is to define such system of space composition factor to diversify the interior space of the apartment housing. Staring from the space analysis, identification of the design factors, characters of the anthropometry for the dwelling behavior, and analyzed dimensions of the interior furniture from the market data have uniformly integrated to engage with such system for innovation and diversification of the space design method. The elements of the composition factors are as follows: 1. Structural elements - $\circled1$Bearing wall $\circled2$Ceiling $\circled3$Floor $\circled4$Structural column 2. furniture elements - $\circled1$Fixed furniture $\circled2$Movable furniture $\circled3$Non-bearing wall $\circled4$F1exible wall $\circled5$Void & Solid 3. Finished material elements - $\circled1$Structural material $\circled2$Doub1e shell $\circled3$Color & Tone $\circled4$Lighting system For the design system selected space in restricted in 3way directional axis X,Y,Z to form its volume and direction of the space composition factors. X-axis is stands for horizontal length of the factor, Y-axis is for the space depth, and lastly, Z-axis is for the hieghts of the space based on anthropometris.

  • PDF