• Title/Summary/Keyword: bearing characteristics

Search Result 1,871, Processing Time 0.026 seconds

EFFECTS OF MECHANICAL PROPERTY VARIABILITY IN LEAD RUBBER BEARINGS ON THE RESPONSE OF SEISMIC ISOLATION SYSTEM FOR DIFFERENT GROUND MOTIONS

  • Choun, Young-sun;Park, Junhee;Choi, In-Kil
    • Nuclear Engineering and Technology
    • /
    • v.46 no.5
    • /
    • pp.605-618
    • /
    • 2014
  • The effects of variability of the mechanical properties of lead rubber bearings on the response of a seismic isolation system are investigated. Material variability in manufacturing, aging, and operation temperature is assumed, and two variation models of an isolation system are considered. To evaluate the effect of ground motion characteristics on the response, 27 earthquake record sets with different peak A/V ratios were selected, and three components of ground motions were used for a seismic response analysis. The response in an isolation system and a superstructure increases significantly for ground motions with low A/V ratios. The variation in the mechanical properties of isolators results in a significant influence on the shear strains of the isolators and the acceleration response of the superstructure. The variation provisions in the ASCE-4 are reasonable, but more strict variation limits should be given to isolation systems subjected to ground motions having low A/V ratios. For application of seismic isolation systems to safety-related nuclear structures, the variation in the material and mechanical properties of the isolation system should be properly controlled during the manufacturing and aging processes. In addition, special consideration should be given to minimize the accidental torsion caused by the dissimilarity in the stiffness variations of the isolators.

Aggregate Criterion for Paved Track Considering Recycling of Railway Ballast (도상자갈 재활용을 고려한 포장궤도용 골재 기준)

  • Lee, Il-Wha
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.4
    • /
    • pp.481-487
    • /
    • 2009
  • On the paved track, the railway ballast is used as aggregate for the filling layer using the pre-packed concrete method. The condition of ballast as the paved track aggregate ensure that the compressive strength, particle distribution size for the pouring and surface clearance to increase the adhesive strength with mortar. It is profitable to recycle the existing railway ballast as a economical supply. In order to increase recycling characteristic, it is necessary to apply the similar criterion which does not exceed the conventional railway ballast criterion. Consequently, this paper was to investigate physical characteristics of existing ballast, particle size distribution, compressive and flexural strength, bearing capacity and filling capacity to prepare the aggregate's recycling. As a result, optimized aggregate criterion is suggested.

Wear-characteristics variation of Fe-C-N alloy with changing content of carbon and nitrogen (탄소와 질소 함량에 따른 탄질소 복합첨가강의 내마멸 특성 변화)

  • Park, J.K.;Yi, S.K.;Kim, S.J.;Kim, Y.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.385-388
    • /
    • 2009
  • Dry-sliding-wear behavior of Fe-18Cr-l0Mn steel with various carbon and nitrogen contents was characterized, and the effect of carbon and nitrogen contents on the wear was investigated. Dry sliding wear tests of the steel were carried out at room temperature against an AISI 52100 bearing steel ball using a pin-on-disk wear tester. Applied wear loads were varied from 10 N to 100 N, and the sliding distance was fixed as 720 m. Worn surfaces and the wear debris of the steel were examined using an SEM to find out the wear mechanism. It was found that the Fe-18Cr-10Mn with both carbon and nitrogen exhibited superior wear resistance to the steel with only nitrogen. The wear resistance of the Fe-18Cr-10Mn-xC-yN alloy increased with the increase of the carbon content. The excellent wear resistance of the Fe-18Cr-10Mn-xC-yN alloy was explained by the increased strain-hardening capability with the interstitial atoms.

  • PDF

Thermal Sprayed AlSiMg/TiC Composite Coatings : Wear Characteristics (II) (AlSiMg/TiC 복합 용사피막 : 마모 특성 (II))

  • 양병모;변응선;박경채
    • Journal of Welding and Joining
    • /
    • v.18 no.5
    • /
    • pp.105-111
    • /
    • 2000
  • The wear behavior of thermal sprayed AlSiMg-40TiC composite coatings were studied as a function of load and sliding velocity under unlubricated conditions. Experiments were performed using a block-on-ring(WC-6wt%/Co, Hv 1500) type. The tests were carried out a various load(30∼ 125.5N) and sliding velocity(0.5∼2.0m/s). Three wear rate regions were observed in the AlSiMg-40TiC composite coatings. The wear rate in region I at low load (less then 8N( were less than 1×{TEX}$10^{-5}${/TEX}㎣/m. Low wear rates in region I resulted from the load-bearing capacity of TiC particles. The transition from region I to II occurred when the applied load exceeded the fracture and pull-out strength of the particles. The TiC fractured particles trapped between the specimen and the counterface acted as third-body abrasive wear. The subsurface layer worn surface in region II was composed of the mechanically mixed layer (MML). The wear rate increase abruptly above a critical load (region III). The high wear rate in region III was induced by frictional temperature and involves massive surface damage.

  • PDF

The Properties of Early Strength of Concrete Containing Slag and Fly-ash for In-situ Application (현장 적용을 위한 3성분계 콘크리트의 조기강도 특성)

  • Jung Chul-Hee;Kim Kyoung-Min;Lee Jin-Woo;Bae Yeon Ki;Lee Jae-Sam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.497-500
    • /
    • 2005
  • This study was performed to evaluate the characteristics which are slump, air content and time of set in fresh concrete and compressive strength of hardened concrete containing slag powder and fly-ash. Replacement rate of FA is fixed on 10$\%$ and replacement rate of slag powder are 0$\%$, 20$\%$ and 30$\%$. Also AE water-reducing agents(standard type, accelerating type) are used. The results were as follows. (1)Slump flow of concrete using AE water-reducing agents is similar. Flowability is incresed when replacement rate of slag powder is increased due to slag powder's ball bearing reaction.(2)Time of set of concrete using accelerating type agent is more faster than that of concrete using standard type agent because of ettringite generation that promote setting.(3)Early strength of three-component concrete using accelerating type agent is higher than that using standard type agent. Therefore cumulative pore is reduced due to ettringite

  • PDF

Mechanical Characteristics of Cable Truss Roof Systems (케이블 트러스 지붕 시스템의 역학적 특성)

  • Park, Kang-Geun;Lee, Dong-Woo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.89-96
    • /
    • 2016
  • Cable structures are lightweight structures of flexible type, cable members have only axial stiffness related to tension, they can carry neither bending nor compression. This study is the analysis of cable truss systems are composed of upper and low cables by connecting bracing cables, the structural principle is based on a tensegrity system by using bracing tension members, discontinuous compression members and continuous tension members. A hanging roof of cable truss system is too flexible against vertical loads, most cable members are stabilized by connecting the prestressed upper and lower cable by bracing cables. A cable truss roof system is formed by adding a set of cables with reverse curvature to the suspension cables. With the sets of cables having opposite curvature to each other, cable truss is able to carry vertical load in both upward and downward direction with equal effectiveness, and then a cable truss acts as load bearing elements by the assemble of ridge cables, valley cables and bracing cables. This paper will be shown the geometric non-linear analysis result of cable truss systems with various sag ratio for deflections and tensile forces, the analytical results are compared with the results of other researchers.

Assessment of Static and Cyclic Load Model Test on Soft Clay Layer Reinforced by Geosynthetics (토목섬유로 보강한 연약지반의 정$\cdot$반복하중 모형실험에 의한 평가)

  • Kim Young-Su;Kwon Sung-Mok;Kim Yeun-Wook;Kim Hyoung-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.179-186
    • /
    • 2005
  • Each static and cyclic load test was performed in a laboratory model test. As a result, ground displacement decreased and bearing capacity of the soil increased owing to the sheer strength of geosynthetics in general. In addition, numerical analysis was operated using Mohr-Coulomb, Modified Cam-Clay models, and FLAC 4.0 2D and compared with the laboratory model test. The results were shown to be of a great difference because the existing equations had not considered the characteristics that sheer strength increases with a load increment. Therefore, this paper proposes an equation of cable elements considering an effect of load given through repeated tests.

Two case studies on structural analysis of transmission towers under downburst

  • Yang, FengLi;Zhang, HongJie
    • Wind and Structures
    • /
    • v.22 no.6
    • /
    • pp.685-701
    • /
    • 2016
  • Downbursts are of great harm to transmission lines and many towers can even be destroyed. The downburst wind field model by Chen and Letchford was applied, and the wind loads of two typical transmission towers in inland areas and littoral areas were calculated separately. Spatial finite element models of the transmission towers were established by elastic beam and link elements. The wind loads as well as the dead loads of conductors and insulators were simplified and applied on the suspension points by concentrated form. Structural analysis on two typical transmission towers under normal wind and downburst was completed. The bearing characteristics and the failure modes of the transmission towers under downburst were determined. The failure state of tower members can be judged by the calculated stress ratios. It shows that stress states of the tower members were mainly controlled by 45 degree wind load. For the inland areas with low deign wind velocity, though the structural height is not in the highest wind velocity zone of downburst, the wind load under downburst is much higher than that under normal wind. The main members above the transverse separator of the legs will be firstly destroyed. For the littoral areas with high deign wind velocity, the wind load under downburst is lower than under normal wind. Transmission towers are not controlled by the wind loads from downbursts in design process.

Crosslinkable Warm-melt-Polyurethanes Offer Instant-fix Characteristics

  • Merz, Peter W.
    • Journal of Adhesion and Interface
    • /
    • v.3 no.1
    • /
    • pp.37-42
    • /
    • 2002
  • Adhesives are becoming increasingly accepted for advanced engineering/boding tasks. Therefore the understanding of the basic principles and the benefits of elastic bonding and structural bonding respectively is of utmost importance. Structural bonding means adhesive performance in load-bearing environments. Furthermore. the time to achieve handling strength has an impact on the economics of an assembly line. The paper gives briefly a summary about the fundamentals of elastic bonding and discusses different adhesive systems in the context of handling strength. Hereby the focus lies on the Warm Melt Technology, and its potential is compared to standard adhesives (l-part, 2-part and Booster Technology, a special 2-C system). Examples illustrate their economical benefits. Main Points : ${\bullet}$ The basic principles and benefits of elastic bonding ${\bullet}$ Warm-melt Technology in comparison with standard adhesives ${\bullet}$ Handling strength an economic issue ${\bullet}$ Combination with Booster-Technology, a special 2-C PUR system ${\bullet}$ Presentation of real world applications Learning Objectives: ${\bullet}$ Fundamentals of elastic bonding ${\bullet}$ Warm-melt Technology: correlation between chain length and cristallinity ${\bullet}$ Handling strength and curing speed of various systems in comparison ${\bullet}$ Real world applications illustrate the potential of the Warm-melt Technology.

  • PDF

The Seismic Response According to Rise-Span Ratio of the Arch Structure With Seismic Isolation (라이즈-스팬비에 따른 면진 아치구조물의 지진응답 분석)

  • Kim, Su-Geun;Kim, Yu-Seong;Kim, Gee-Cheol;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.1
    • /
    • pp.55-65
    • /
    • 2018
  • In order to reduce the seismic response of the spatial structure, a seismic isolation system with sufficient flexibility is used. The natural period of structure with seismic isolation system got be long to avoid prominent period. In this study, The seismic response of the truss-arch structure, which is modeled in three types according to the rise-span ratio is analyzed on El-centro, Northridge and Artificial Earthquake and compared with the seismic response of the truss-arch structure with lead rubber bearing(LRB). When seismic load is applied to the truss arch with isolation system, the horizontal acceleration response of the truss arch is reduced and vertical seismic response is also reduced. The application of the seismic isolation system is effective in controlling the seismic response.