• 제목/요약/키워드: beam width

검색결과 1,145건 처리시간 0.032초

미세접촉프린팅 공정을 이용한 유연성 유기박막소자(OTFT)설계 및 제작 (Design and Fabrication of Flexible OTFTs by using Nanocantact Printing Process)

  • 조정대;김광영;이응숙;최병오
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.506-508
    • /
    • 2005
  • In general, organic TFTs are comprised of four components: gate electrode, gate dielectric, organic active semiconductor layer, and source and drain contacts. The TFT current, in turn, is typically determined by channel length and width, carrier field effect mobility, gate dielectric thickness and permittivity, contact resistance, and biasing conditions. More recently, a number of techniques and processes have been introduced to the fabrication of OTFT circuits and displays that aim specifically at reduced fabrication cost. These include microcontact printing for the patterning of metals and dielectrics, the use of photochemically patterned insulating and conducting films, and inkjet printing for the selective deposition of contacts and interconnect pattern. In the fabrication of organic TFTs, microcontact printing has been used to pattern gate electrodes, gate dielectrics, and source and drain contacts with sufficient yield to allow the fabrication of transistors. We were fabricated a pentacene OTFTs on flexible PEN film. Au/Cr was used for the gate electrode, parylene-c was deposited as the gate dielectric, and Au/Cr was chosen for the source and drain contacts; were all deposited by ion-beam sputtering and patterned by microcontact printing and lift-off process. Prior to the deposition of the organic active layer, the gate dielectric surface was treated with octadecyltrichlorosilane(OTS) from the vapor phase. To complete the device, pentacene was deposited by thermal evaporation and patterned using a parylene-c layer. The device was shown that the carrier field effect mobility, the threshold voltage, the subthreshold slope, and the on/off current ratio were improved.

  • PDF

적응필터를 이용한 적층 복합재료에서의 역산란 X-Ray 신호처리 및 복원 (Reconstruction and Deconvolution of X-Ray Backscatter Data Using Adaptive Filter)

  • 김노유
    • 비파괴검사학회지
    • /
    • 제20권6호
    • /
    • pp.545-554
    • /
    • 2000
  • 충격에 의해 복합 재료 내에 발생하는 층간 박리를 정량적으로 평가하기 위한 비파괴 방법중에서 Compton X-ray 역산란 기술은 초음파에 비해 비접촉식이며 박리 층간의 상호간섭이 없어 복합재료 판면의 박리 층의 위치와 크기를 검사하는데 효과적인 방법으로 사용되어 왔다. 그러나 X-ray역산란 기술에 있어서 복합재료의 박리 층과 같은 미세한 결함의 측정을 위해 측정 정도를 높이면 역산란 양의 감소로 인해 신호 대 잡음 비(SNR)가 급격히 감소하여 결함검출 가능성이 크게 저하된다. 본 논문에서는 복합재료의 특성을 고려한 X-ray 역산란 모델을 기초로 적응필터를 사용하여 결함신호를 비선형 감쇄, 빔 경화(X-ray hardening), 비균질 특성과 같은 잡음 신호로부터 분리, 추출하는 방법을 제시하였다. 이렇게 분리된 결함신호로부터 정량적인 결함(박리)의 위치와 크기를 수학적 산란 모델과의 비교를 통해 최소 자승법을 이용하여 결정하였다.

  • PDF

800MHz 대역 연안해역기지국용 U-Slot 적층구조 안테나 설계 (The Design of U-Slot Stack Structure Antenna for 800MHz Band Coastal Sea Base Station Applications)

  • 김갑기
    • 한국정보통신학회논문지
    • /
    • 제12권6호
    • /
    • pp.984-989
    • /
    • 2008
  • 본 논문에서는 마이크로스트립 안테나의 좁은 대역폭 문제를 개선하여 UHF 대역 내에 있는 CDMA(Code Division Multiple Access), GSM(Global System for Mobile Telecommunication), TRS(Trunked Radio System)대역을 통합하여 우리나라 연안 해역에 있는 기지국 및 중계기에 상용 가능한 800MHz 다중대역 안테나를 설계하고자 한다. 안테나의 대역폭을 개선하기 위해 L형 급전구조를 이용하였으며, 직사각형 패치에 U-Slot을 추가하여 이중 공진 효과를 이용하였고, 적층구조를 이용하여 이득을 개선하였다. 설계된 안테나의 주파수 대역폭(VSWR 2:1)은 $792{\sim}1040MHz$로 248MHz(33%)의 광대역 특성을 가지며, 방사패턴은 이득이 9.4dBi 이상, 3dB 빔폭은 $60^{\circ}$이상의 개선된 특성을 보였다.

Predictors of midpalatal suture expansion by miniscrew-assisted rapid palatal expansion in young adults: A preliminary study

  • Shin, Hyerin;Hwang, Chung-Ju;Lee, Kee-Joon;Choi, Yoon Jeong;Han, Sang-Sun;Yu, Hyung Seog
    • 대한치과교정학회지
    • /
    • 제49권6호
    • /
    • pp.360-371
    • /
    • 2019
  • Objective: We sought to determine the predictors of midpalatal suture expansion by miniscrew-assisted rapid palatal expansion (MARPE) in young adults. Methods: The following variables were selected as possible predictors: chronological age, palate length and depth, midpalatal suture maturation (MPSM) stage, midpalatal suture density (MPSD) ratio, the sella-nasion (SN)-mandibular plane (MP) angle as an indicator of the vertical skeletal pattern, and the point A-nasion-point B (ANB) angle for anteroposterior skeletal classification. For 31 patients (mean age, 22.52 years) who underwent MARPE treatment, palate length and depth, MPSM stage and MPSD ratio from the initial cone-beam computed tomography images, and the SN-MP angle and ANB angle from lateral cephalograms were assessed. The midpalatal suture opening ratio was calculated from the midpalatal suture opening width measured in periapical radiographs and the MARPE screw expansion. Statistical analyses of correlations were performed for the entire patient group of 31 subjects and subgroups categorized by sex, vertical skeletal pattern, and anteroposterior skeletal classification. Results: In the entire patient group, the midpalatal suture opening ratio showed statistically significant negative correlations with age, palate length, and MPSM stage (r = -0.506, -0.494, and -0.746, respectively, all p < 0.01). In subgroup analyses, a strong negative correlation was observed with the palate depth in the skeletal Class II subgroup (r = -0.900, p < 0.05). Conclusions: The findings of this study indicated that age, palate length, and MPSM stage can be predictors of midpalatal suture expansion by MARPE in young adults.

Picosecond Mid-Infrared 3.8 ㎛ MgO:PPLN Optical Parametric Oscillator Laser with High Peak Power

  • Chen, Bing-Yan;Wang, Yu-Heng;Yu, Yong-Ji;Jin, Guang-Yong
    • Current Optics and Photonics
    • /
    • 제5권2호
    • /
    • pp.186-190
    • /
    • 2021
  • In this study, a compact, picosecond, mid-infrared 3.8 ㎛ MgO:PPLN optical parametric oscillator (OPO) laser output with high peak power is realized using a master oscillator power amplifier (MOPA) 1 ㎛ solid-state laser seeded by a picosecond fiber laser as the pump source. The pump source was a 50 MHz and 10 ps fiber seed source. After AOM pulse selection and two-stage solid-state amplification, a 1,064 nm laser output with a repetition frequency of 1-2 MHz, pulse width of 9.5 ps, and a maximum average power of 20 W was achieved. Furthermore, a compact short cavity with a unsynchronized pump is adopted through the design of an OPO cavity structure. When the injection pump power was 15 W and the repetition frequency was 1 MHz, the average output power of idler light was 1.19 W, and the corresponding peak power was 119 kW. The optical conversion efficiency was 7.93%. When the repetition frequency was increased to 2 MHz, the average output power of idler light was 1.63 W, the corresponding peak power was 81.5 kW, and the optical conversion efficiency was 10.87%. At the same time, the output wavelength was measured at 3,806 nm, and the beam quality was MX2 = 3.21 and MY2 = 3.34.

골격성 II급 소아·청소년의 상기도 공간에 영향을 미치는 요인 : CBCT 연구 (Factors Influencing Upper Airway Dimensions in Skeletal Class II Children and Adolescents: A CBCT Study)

  • 김병화;이제우;라지영
    • 대한소아치과학회지
    • /
    • 제48권1호
    • /
    • pp.1-11
    • /
    • 2021
  • 이 연구의 목적은 골격성 2급 부정교합 소아·청소년의 상기도 공간을 분석하고, 이에 영향을 미치는 요인을 알아보고자 함이다. 총 67명의 골격성 2급 소아·청소년의 CBCT영상으로 연구를 진행하였다. 상기도 부피와 최소 단면적은 3차원 CBCT 영상을 통해 평가하였으며, 악안면 형태와 골 성숙도는 2차원 두부방사선사진을 통해 평가하였다. 상기도 부피 및 최소 단면적과 다양한 변수들간의 연관성이 분석되었다. 상기도 공간은 최대 성장기 이전의 환자에서 가장 작았으며, 연령과 양의 상관관계를 보였다. 상기도 부피는 전안면 고경 및 연령과, 최소 단면적은 하악 폭경 및 연령과 가장 높은 상관관계를 나타냈다. 골격성 2급 소아·청소년의 상기도 공간은 연령, 골 성숙도, 세 평면에서의 악안면 형태와 유의한 연관성을 가졌다.

콘크리트 매립 센서를 위한 이중 슬롯 패치 안테나 (Stacked Slot Patch Antenna for Wireless Sensors Embedded in Concrete)

  • 이재혁;이성호;이해영
    • 한국전자파학회논문지
    • /
    • 제29권12호
    • /
    • pp.915-923
    • /
    • 2018
  • 본 논문은 ISM 대역인 902~928 MHz에서 건물의 내구성을 진단하기 위한 콘크리트 매립형 안테나 설계에 관하여 서술한다. 이에 안테나가 매립되는 환경에서도 콘크리트 매질 특성에 의해 임피던스 변화가 크지 않는 이중 슬롯 패치 안테나를 제안하였다. 함수율에 따라 변하는 콘크리트 매질에 의한 성능 열화를 최소화하기 위해 제안하는 안테나는 기생 패치를 이용하여 대역폭을 확장하였다. 제작된 안테나는 전 대역에서 VSWR 2 : 1 이하 특성을 만족하며, 빔 폭은 80도 정도이며, 7 dBi 이상을 만족하는 이득을 가진다. 제안한 안테나는 직사각형 콘크리트 블록에 장착하여 측정하였으며, 모의실험과 실제 측정을 통해 함수율 변화에 따른 반사손실 및 이득을 확인하였다.

60 GHz 대역 능동 안테나 모듈 설계 (Active Antenna Module for 60 GHz Frequency Band)

  • 안세인;윤상원
    • 한국전자파학회논문지
    • /
    • 제30권6호
    • /
    • pp.518-521
    • /
    • 2019
  • 본 논문에서는 상용 트랜스미터 칩과 패치 어레이 안테나를 결합하여 60 GHz 대역에서 동작하는 능동 안테나 모듈을 설계, 제작하였다. 설계된 모듈은 안테나 PCB와 트랜스미터 칩이 장착된 송신 모듈 PCB가 결합되는 구조로 하였다. 주파수 제어신호 및 바이어스 제어신호는 아두이노 키트를 사용하여 인가하였으며, 기저대역의 I/Q 신호가 트랜스미터 칩으로 인가될 수 있도록 하였다. 송신 모듈의 출력은 단일 출력으로 안테나에 연결되므로 차동 출력을 내는 트랜스미터 칩의 출력을 링 하이브리드 발룬에 전달하고, 이를 초소형 상용 커넥터로 $2{\times}4$ 마이크로스트립 패치 어레이 안테나 PCB로 전달되도록 하였다. 최종 출력되는 밀리미터파 신호의 방사패턴 측정을 통하여 시뮬레이션 결과와 비교하는 방식으로 확인하였다. 제작된 능동 안테나 모듈의 방사패턴 측정 결과, 3 dB 빔폭과 null 포인트의 위치가 시뮬레이션 결과와 잘 일치함을 확인하였다.

Midfacial soft tissue changes after maxillary expansion using micro-implant-supported maxillary skeletal expanders in young adults: A retrospective study

  • Nguyen, Hieu;Shin, Jeong Won;Giap, Hai-Van;Kim, Ki Beom;Chae, Hwa Sung;Kim, Young Ho;Choi, Hae Won
    • 대한치과교정학회지
    • /
    • 제51권3호
    • /
    • pp.145-156
    • /
    • 2021
  • Objective: The aim of this retrospective study was to assess the midfacial soft tissue changes following maxillary expansion using micro-implant-supported maxillary skeletal expanders (MSEs) in young adults by cone-beam computerized tomography (CBCT) and to evaluate the correlations between hard and soft tissue changes after MSE usage. Methods: Twenty patients (mean age, 22.4 years; range, 17.6-27.1) with maxillary transverse deficiency treated with MSEs were selected. Mean expansion amount was 6.5 mm. CBCT images taken before and after expansion were superimposed to measure the changes in soft and hard tissue landmarks. Statistical analyses were performed using paired t-test and Pearson's correlation analysis on the basis of the normality of data. Results: Average lateral movement of the cheek points was 1.35 mm (right) and 1.08 mm (left), and that of the alar curvature points was 1.03 mm (right) and 1.02 mm (left). Average forward displacement of the cheek points was 0.59 mm (right) and 0.44 mm (left), and that of the alar curvature points was 0.61 mm (right) and 0.77 mm (left) (p < 0.05). Anterior nasal spine (ANS), posterior nasal spine (PNS), and alveolar bone width showed significant increments (p < 0.05). Changes in the cheek and alar curvature points on both sides significantly correlated with hard tissue changes (p < 0.05). Conclusions: Maxillary expansion using MSEs resulted in significant lateral and forward movements of the soft tissues of cheek and alar curvature points on both sides in young adults and correlated with the maxillary suture opening at the ANS and PNS.

노출지수를 이용한 요추 X선 촬영의 조사야 유효성 평가 (Effect of Field Size on the Clinical Exposure Index for Lumbar Spine X-ray Examination)

  • 박혜민;윤용수;김정수;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.183-187
    • /
    • 2021
  • The field size of the lumbar spine X-ray examination, which belongs to the most frequent examination in general radiography, is 5 times wider than the width of the lumbar spine. Exposure index (EI) as per International Electrotechnical Commission has a proportional relationship with the dose incident on the image receptor for clinical protocols in addition to RQA5, which is a calibration beam quality. In this study, the effectiveness of the set field size was evaluated through the change of EI according to the size of field during lumbar spine X-ray examinations. Lumbar anterior-posterior and lateral examinations was performed using a whole-body phantom, and the national average exposure conditions of Korea investigated in 2017 were introduced for the X-ray exposure. As a result of comparing the EI displayed on the console of digital radiography system for the three field size in ① 18 × 36 cm2 ② 25 × 36 cm2 ③ 36 × 36 cm2, the EI values showed a tendency to increase as the field size increased. Since the patient dose, such as organ dose around the lumbar spine, increases as the field size becomes larger, thus, if the EI obtained from the field size at a level that does not interfere with diagnosis is set as a reference, the effectiveness of the field size can be evaluated through the EI displayed on the console when the lumbar spine X-ray examination is conducted.