• 제목/요약/키워드: beam spot

검색결과 285건 처리시간 0.025초

레이저를 이용한 박판 버의 정밀측정 (Precision measuring of burrs on sheet metal using the laser)

  • 신홍규;홍남표;김헌영;김병희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1824-1827
    • /
    • 2003
  • The sheet metal shearing process is normally used in the precision elements such as semi-conductor components. In precision elements, burrs usually reduce the quality of machined parts and cause interference, jamming and misalignment during assembly procedures and because of their sharpness, they can be safety hazard to personnel. Furthermore, not only burrs are hard to predict and avoid, but also deburring, the process of removing burrs, is time-consuming and costly. In order to get the burr-free parts, therefore, we developed the precise burr measuring system using the laser. The laser burr measuring system consists of the laser probe, the photo detector, the achromatic doublet lens, and the rotary & the X-Y table. In previous reports, we used simple vertical measuring method. But, as we used relatively bigger laser spot diameter and had the limited reflection angle, it was difficult to obtain the precise measuring results. So called, the spot size effect makes the profile of burr measured distorted and the burr height measured smaller. By introducing the novel laser measuring method which employing the achromatic lens system and the tilting mechanism, we could make the spot size smaller and get the appropriate beam direction angle. Through the experiments, the accuracy of the developed system is proved. The burr height measured during the punching process can be used for automatic deburring and in-situ aligning.

  • PDF

화원에 따른 광전식 연기감지기 반응시간 분석 (Analysis of the Response Time of a Photoelectric Spot-Type Smoke Detector Depending on the Type of Fires)

  • 지승욱
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.89-94
    • /
    • 2013
  • The fire testing performed for smoke detector model approval in Korea tests only one kind of fire smoke. A photoelectric spot-type smoke detector using Mie scattering is affected by the wavelength of light beam and the particle diameter. According to UL (Underwriters Laboratories Inc.) 268 standard, this paper analyze the characteristic of the response for a photoelectric spot-type smoke detector on sale in Korea using various fire smokes. Probability that the response time is included in non-defective range is 100% in paper fire, 90% in wood fire and 75% in flammable liquid fire, 90% in wood fire and 75% in flammable liquid fire. According to the estimation for population mean of the response time choosing a confidence level of 99%, a maximum of 19% for wood fire and that of 38% for flammable liquid fire are defective. As the result of analysis of smoke particle, this paper is found that these results are caused by the smoke particles are wide variations in size or have very black.

Multi-slit prompt-gamma camera for locating of distal dose falloff in proton therapy

  • Park, Jong Hoon;Kim, Sung Hun;Ku, Youngmo;Kim, Chan Hyeong;Lee, Han Rim;Jeong, Jong Hwi;Lee, Se Byeong;Shin, Dong Ho
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1406-1416
    • /
    • 2019
  • In this research, a multi-slit prompt-gamma camera was developed to locate the distal dose falloff of the proton beam spots in spot scanning proton therapy. To see the performance of the developed camera, therapeutic proton beams were delivered to a solid plate phantom and then the prompt gammas from the phantom were measured using the camera. Our results show that the camera locates the 90% distal dose falloff (= d90%), within about 2-3 mm of error for the spots which are composed $3.8{\times}10^8$ protons or more. The measured location of d90% is not very sensitive to the irradiation depth of the proton beam (i.e., the depth of proton beam from the phantom surface toward which the camera is located). Considering the number of protons per spot for the most distal spots in typical treatment cases (i.e., 2 Gy dose divided in 2 fields), the camera can locate d90% only for a fraction of the spots depending on the treatment cases. However, the information of those spots is still valuable in that, in the multi-slit prompt-gamma camera, the distal dose falloff of the spots is located solely based on prompt gamma measurement, i.e., not referring to Monte Carlo simulation.

On the Beam Focusing Behavior of Time Reversed Ultrasonic Arrays Using a Multi-Gaussian Beam Model

  • Jeong, Hyun-Jo;Lee, Jeong-Sik;Jeong, Yon-Ho;Bae, Sung-Min
    • 비파괴검사학회지
    • /
    • 제28권6호
    • /
    • pp.531-537
    • /
    • 2008
  • One of the fundamental features of time reversal acoustic (TRA) techniques is the ability to focus the propagating ultrasonic beam to a specific point within the test material. Therefore, it is important to understand the focusing properties of a TR device in many applications including nondestructive testing. In this paper, we employ an analytical scheme for the analysis of TR beam focusing in a homogeneous medium. More specifically, a nonparaxial multi-Gaussian beam (NMGB) model is used to simulate the focusing behavior of array transducers composed of multiple rectangular elements. The NMGB model is found to generate accurate beam fields beyond the nonparaxial region. Two different simulation cases are considered here for the focal points specified on and off from the central axis of the array transducer. The simulation results show that the focal spot size increases with increasing focal length and focal angle. Furthermore, the maximum velocity amplitude does not always coincide with the specified focal point. Simulation results for the off-axis focusing cases do demonstrate the accurate steering capability of the TR focusing.

$Ga^+$ 이온 빔 조사량에 따른 자기 조립 단분자막의 습식에칭 특성 (Effect of $Ga^+$ Ion Beam Irradiation On the Wet Etching Characteristic of Self-Assembled Monolayer)

  • 노동선;김대은
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.326-329
    • /
    • 2005
  • As a flexible method to fabricate sub-micrometer patterns, Focused Ion Beam (FIB) instrument and Self-Assembled Monolayer (SAM) resist are introduced in this work. FIB instrument is known to be a very precise processing machine that is able to fabricate micro-scale structures or patterns, and SAM is known as a good etch resistance resist material. If SAM is applied as a resist in FIB processing fur fabricating nano-scale patterns, there will be much benefit. For instance, low energy ion beam is only needed for machining SAM material selectively, since ultra thin SAM is very sensitive to $Ga^+$ ion beam irradiation. Also, minimized beam spot radius (sub-tens nanometer) can be applied to FIB processing. With the ultimate goal of optimizing nano-scale pattern fabrication process, interaction between SAM coated specimen and $Ga^+$ ion dose during FIB processing was observed. From the experimental results, adequate ion dose for machining SAM material was identified.

  • PDF

유한요소법을 이용한 X-선관 양극각도에 의존하는 전자빔 초점 특성 연구 (Property of Focal Spot of Electron Beam Depending on the Anode Angle of X-ray Tube Using a Finite Element Method)

  • 박태영;노영일;이상석;박래준;김기선
    • 한국자기학회지
    • /
    • 제25권2호
    • /
    • pp.52-57
    • /
    • 2015
  • 텅스텐 타겟인 양극의 각도에 의존하는 X-선관 집속관의 전자빔 초점 크기를 오페라-3차원/스칼라(OPERA-3D/SCALAR) 프로그램을 이용하여 구하였다. 시뮬레이션 분석은 X-선관을 음극과 양극 그리고 4영역을 나누어 유한요소법을 적용하였다. X-선 집속관의 필라멘트로부터 방출되는 열전자 궤적은 전자밀도 분포함수에 따라 양극에 도달할 때 실초점으로 집속되고 양극에 부딪쳐서 유효 초점 크기로 X-선을 발생하게 된다. 전자빔 실초점 크기는 X-선 집속관 모양을 결정짓는 폭, 길이, 높이를 조절하여 줄일 수 있었고, 양극각도의 크기에 따라 미세하게 변하였다. 양극각도가 $10^{\circ}{\sim}17^{\circ}$에서는 전자빔 실초점 크기를 $70{\mu}m$ 이내로 유지하였고, 가장 최소 초점크기는 $15^{\circ}$에서 실초점 크기가 $40{\mu}m$로 나타났다. 최적화된 X-선 집속관의 변수들로 시뮬레이션하는 열전자의 방출 궤적을 분석하여 얻은 마이크로 크기인 실초점을 활용하는 새로운 의료 영상진단기기 개발이 가능할 것으로 보여진다.

레이저 광원 형상이 레이저 충격 피닝 잔류응력에 미치는 영향 (Effects of Laser Source Geometry on Laser Shock Peening Residual Stress)

  • 김주희;김윤재;김정수
    • 대한기계학회논문집A
    • /
    • 제36권6호
    • /
    • pp.609-615
    • /
    • 2012
  • 레이저 충격 피닝 처리 시 레이저 광원으로부터 금속표면에 조사되는 레이저 빔 형상은 다양하다. 레이저 형상은 표면에서 발생하는 압력파의 특성을 결정하기 때문에 금속 표면과 깊이 방향에 대한 잔류응력 분포에 영향을 미칠 수 있다. 본 논문에서는 레이저 충격 피닝 처리시 레이저 광원 형상이 인코넬 alloy 600 합금의 잔류응력에 미치는 영향을 분석하였다. 레이저 광원 형상은 원형, 사각형, 타원형 형상이 고려되었으며, 표면과 깊이 방향에 대한 압축잔류응력 특성을 비교하였다. 표면에서 생성되는 압축잔류응력은 원형 레이저 형상이 최대이지만 중심부에서 인장응력이 발생하고, 깊이 방향에서는 타원형 레이저 형상이 최대 압축잔류응력을 생성한다. 소성변형 발생 깊이는 사각형에 비해 원형과 타원형이 양호하다.

Spot용접 접합면의 초음파 비파괴평가 기법 제 1보 C-scan 기법을 중심으로 (Ultrasonic C-scan Technique for Nondestructive Evaluation of Spot Weld Quality)

  • 박익근
    • 비파괴검사학회지
    • /
    • 제14권2호
    • /
    • pp.112-121
    • /
    • 1994
  • 초음파 C-scan 기법에 의해 스폿(spot)용접의 품질 평가를 위한 비파괴진단 평가에 관한 기초적인 실험적 검토를 하였다. 먼저, 스폿용접부 초음파탐상에 앞서 뉴우톤링의 모델링 실험을 통해 미소 간극을 갖는 접합계면에서의 초음파 반사 거동의 해석 결과를 근거로 스폿용접부의 너겟 형상과 크기, void 결함등의 정량적 평가와 corona bond의 정확한 식별에 최적한 초음파시험방법 및 조건의 설정을 시도하였다. 초음파시험 후 용접시험편을 절단하고, 그 절단면을 초음파현미경(SAM)과 광학현미경의 단면 관찰을 통해 스폿용접 품질 평가를 위한 초음파 비파괴평가법의 유용 가능성 유무, 적용 한계 등을 검토하였다. 그 결과 본 실험에 사용한 집속 초음파탐촉자(25MHz)에 의한 너겟 내부에 존재하는 void 크기의 검출한계는 $10{\mu}m$였으며 너겟 크기는 초음파시험의 경우가 최대 1mm정도 크게 측정되어 corona bond의 정확한 식별과 너겟 직경의 정량적 평가에 접근하기 위해서는 초음파 C-scan 데이터의 각종 화상 처리 기술의 적용에 의한 corona bond부의 명확한 식별 방법에 대한 연구 검토가 요망됨을 알 수 있었다.

  • PDF

포토 다이오드 조정방식을 이용한 광 픽업용 저가 홀로그램 모듈 (Low-Cost Hologram Module for Optical Pickup by Adjusting Photodiode Package)

  • 정호섭;경천수
    • 한국광학회지
    • /
    • 제16권4호
    • /
    • pp.345-353
    • /
    • 2005
  • 포토 다이오드(photodiode) 조정 방식을 이용해서, 비전 시스템을 장착한 고가의 정밀 자동 조립조정 장비 없이 홀로그램 픽업 모듈을 제작하는 새로운 방법을 제안하였다. 저가격화를 위해서 리드 프레임형의 반도체 레이저와 COB(Chip on Board)형의 포토 다이오드를 사용했고, 초점 에러 신호(focus error, FES) 검출방법은 스팟 사이즈 검출법(spot size detection, SSD), 트랙 에러 신호(tracking error, TES) 검출방법은 삼빔법(3 beam method)을 이용했다. 이를 만족하는 픽업 홀로그램 모듈 광학계를 설계하고, 조립조정 프로세스 수립 및 시스템을 제작하였으며, 조립된 홀로그램 모듈을 이용하여 CD에서 데이터를 검출하는 실험을 통해 제안된 포토 다이오드 조정방식의 유용함을 입증하였다.

경면 거칠기 측정을 위해 레이저 입사 강도 조정에 의한 정반사 광량 추정 알고리즘 개발 (Estimation of Specular Light Power by Adjusting Incident Laser Power for Measuring Mirror-Like Surface Roughness)

  • 서영호;김주년;안중환
    • 한국정밀공학회지
    • /
    • 제21권6호
    • /
    • pp.94-101
    • /
    • 2004
  • From the Beckmann's reflection model of wave incident, reflected light from a surface is known to have not only specular but also diffuse components. The specular component dominant a surface for a mirror-like surface is distributed on the almost the same area as the spot on the surface, but the diffuse component region dominant f3r a rough surface spreads scattered on the larger areas than the spot. Therefore, statistic parameters from the scattered light distribution are more meaningful in the diffuse region, while the magnitude of rather meaning in the specular region. In usual, there need two sensors to acquire two kinds of information: Photo-detector for light intensity magnitude and image sensor for light intensity distribution. But dual sensor scheme requires a beam splitter usually to feed light to each sensor, and moreover there is not a combination rule to relieve the different sensor characteristics. In this study a new method is proposed for acquisition of the dual information using only an image sensor. Specular region is established on an image area being distinguished from a diffuse component, and laser power is adjusted so that no pixel of the image sensor in the specular region is saturated. Simulation based on the light reflection theory and the experimental results are quite well matched, and thus the proposed method was proved to be very useful for mirror-like surface measurement.