• 제목/요약/키워드: beam reinforcement

검색결과 920건 처리시간 0.021초

Study of exterior beam-column joint with different joint core and anchorage details under reversal loading

  • Rajagopal, S.;Prabavathy, S.
    • Structural Engineering and Mechanics
    • /
    • 제46권6호
    • /
    • pp.809-825
    • /
    • 2013
  • In the present study, in reinforced concrete structures, beam-column connections are one of the most critical regions in areas with seismic susceptibility. Proper anchorage of reinforcement is vital to enhance the performance of beam-column joints. Congestion of reinforcement and construction difficulties are reported frequently while using conventional reinforcement detailing in beam-column joints of reinforced concrete structures. An effort has been made to study and evaluate the performance of beam-column joints with joint detailing as per ACI-352 (mechanical anchorage), ACI-318 (conventional hooks bent) and IS-456(full anchorage conventional hooks bent) along with confinement as per IS-13920 and without confinement. Apart from finding solutions for these problems, significant improvements in seismic performance, ductility and strength were observed while using mechanical anchorage in combination with X-cross bars for less seismic prone areas and X-cross bar plus hair clip joint reinforcement for higher seismic prone areas. To evaluate the performances of these types of anchorages and joint details, the specimens were assembled into four groups, each group having three specimens have been tested under reversal loading and the results are presented in this paper.

Seismic design of beam-column joints in RC moment resisting frames - Review of codes

  • Uma, S.R.;Jain, Sudhir K.
    • Structural Engineering and Mechanics
    • /
    • 제23권5호
    • /
    • pp.579-597
    • /
    • 2006
  • The behaviour of reinforced concrete moment resisting frame structures in recent earthquakes all over the world has highlighted the consequences of poor performance of beam column joints. Large amount of research carried out to understand the complex mechanisms and safe behaviour of beam column joints has gone into code recommendations. This paper presents critical review of recommendations of well established codes regarding design and detailing aspects of beam column joints. The codes of practice considered are ACI 318M-02, NZS 3101: Part 1:1995 and the Eurocode 8 of EN 1998-1:2003. All three codes aim to satisfy the bond and shear requirements within the joint. It is observed that ACI 318M-02 requires smaller column depth as compared to the other two codes based on the anchorage conditions. NZS 3101:1995 and EN 1998-1:2003 consider the shear stress level to obtain the required stirrup reinforcement whereas ACI 318M-02 provides stirrup reinforcement to retain the axial load capacity of column by confinement. Significant factors influencing the design of beam-column joints are identified and the effect of their variations on design parameters is compared. The variation in the requirements of shear reinforcement is substantial among the three codes.

GFRP 판을 전단보강재로 사용한 넓은 보의 전단성능 평가 (Evaluation of Shear Strength for Wide Beam using GFRP Plate Shear Reinforcement)

  • 조은선;최진웅;김민숙;김희철;이영학
    • 한국전산구조공학회논문집
    • /
    • 제28권3호
    • /
    • pp.267-274
    • /
    • 2015
  • 본 논문은 넓은 보의 전단강도를 대상으로 한 실험적 평가에 대해 기술하였다. 본 논문의 실험을 통해 넓은 보에 횡방향 단면에서 GFRP 판의 보강개수와 종방향 전단보강 간격, 그리고 유효깊이가 전단강도에 끼치는 영향에 관하여 연구하였다. 총 7개의 시험체에 유공형 GFRP 판 형태로 전단보강재를 보강하여 전단성능 실험을 실시하였다. 본 논문에 기재된 전단보강재는 유공형 판 형태로 제작되어 타설 시 콘크리트의 유동성을 증가시켜 보강재와 콘크리트의 부착력을 향상시켰다. 7개 시험체의 주 변수로는 전단보강재의 횡방향 단면에 대한 판의 보강개수와 종방향 전단보강 간격, 그리고 유효깊이로 정하였다. 시험체의 균열 및 파괴 양상, 변형률과 전단강도비를 분석하였다. GFRP판으로 전단보강된 넓은 보의 전단강도는 ACI 318-11 기준으로 산정되었다. 실험의 결과를 통해 유공형 GFRP 판이 전단보강재로서 넓은 보에 효과적으로 적용됨을 확인하였다.

The effect of fiber reinforcement on behavior of Concrete-Filled Steel Tube Section (CFST) under transverse impact: Experimentally and numerically

  • Yaman, Zeynep
    • Structural Engineering and Mechanics
    • /
    • 제82권2호
    • /
    • pp.173-189
    • /
    • 2022
  • This study presents an experimental and numerically study about the effects of fiber reinforcement ratio on the behavior of concrete-filled steel tubes (CFST) under dynamic impact loading. In literature have examined the behavior of GFRP and FRP wrapped strengthened CFST elements impact loads. However, since the direction of potential impact force isn't too exact, there is always the probability of not being matched the impact force of the area where the reinforced. Therefore, instead of the fiber textile wrapping method which strengthens only a particular area of CFST element, we used fiber-added concrete-filled elements which allow strengthening the whole element. Thus, the effect of fiber-addition in concrete on the behavior of CFST elements under impact loads was examined. To do so, six simply supported CFST beams were constructed with none fiber, 2% fiber and 10% fiber reinforcement ratio on the concrete part of the CFST beam. CFST beams were examined under two different impact loads (75 kg and 225 kg). The impactors hit the beam from a 2000 mm free fall during the experimental study. Numerical models of the specimens were created using ABAQUS finite element software and validated with experimental data. The obtained results such as; mid-span displacement, acceleration, failure modes and energies from experimental and numerical studies were compared and discussed. Furthermore, the Von Misses stress distribution of the CFST beams with different ratio of fiber reinforcements were investigated numerically. To sum up, there is an optimum amount limit of the fiber reinforcement on CFST beams. Up to this limit, the fiber reinforcement increases the structural performances of the beam, beyond that limit the fiber reinforcement decreases the performances of the CFST beam under transverse impact loadings.

묶음 대각철근을 갖는 세장한 철근콘크리트 연결보의 이력거동 (Cyclic Behavior of Slender Reinforced Concrete Coupling Beams with Bundled Diagonal Reinforcement)

  • 한상환;유경환;이기학;신명수
    • 콘크리트학회논문집
    • /
    • 제27권6호
    • /
    • pp.661-668
    • /
    • 2015
  • 병렬전단벽시스템은 횡력저항에 있어서 효율적인 구조시스템이지만, 각 독립벽체를 연결하는 연결보의 복잡한 철근상세로 인해 시공상의 어려움이 있다. ACI-318에서는 개선된 철근상세를 제안했지만, 이 또한 과도한 횡보강근으로 인해 대각철근의 중심부의 철근 배근 혼잡으로 인해 현장 적용에 어려움이 따른다. 본 연구에서는 프리캐스트를 통하여 철근 배근 오차 및 콘크리트 품질 등의 저하를 줄이고 ACI 318-11의 개선된 상세에 따른 기준 실험체와 일반대각철근을 묶음대각철근으로 대체한 철근콘크리트 연결보의 이력거동을 비교 평가하였다. 그 결과, 묶음대각철근을 적용한 실험체는 현행기준에 따른 연결보와 비교하여 유사한 이력거동을 나타냈고, 더 우수한 에너지소산능력을 나타냈다. 묶음대각철근을 적용한 철근콘크리트 연결보가 현행기준에 따르는 연결보를 대체하여 현장적용이 가능할 것으로 판단된다.

순환골재와 폐주물사를 활용한 철근콘크리트보의 휨거동에 관한 실험연구 (Experimental Study of Flexural Behavior of Reinforced Concrete Beam Using WFS and Recycled Aggregate)

  • 김성수;이대교
    • KIEAE Journal
    • /
    • 제8권5호
    • /
    • pp.61-68
    • /
    • 2008
  • For the recycling of the resources and the preservation of the environment, this study's purpose is to measure flexural behavior of the reinforced concrete beams with the major variables like concrete strength, replacement ratio of the recycled aggregate and the waste foundry sand and the tension reinforcement ratio and to present the data of the recycled aggregate used for the structure design. The experiment on the flexural behavior resulted in the followings. The ultimate strength of recycled R/C beam was manipulated proportionate to the tension reinforcement ratio, however the strength instantly decreased after passing the ultimate load due to the destroyed concrete of the compression side. The deflection at the maximum load varied from the tension reinforcement ratio by 5.5 times. The test specimen with the tension reinforcement ratio less than $0.5{\rho}b$ showed constant curve without change in the load from the yield to the ultimate load in contrast to the distinctive plastic region where the displacement was rising. Although the strain of main tension steel with the reinforcement ratio indicate different, the design of recycled concrete member can be applied for current design code for reinforced concrete structure as the ratio of tension reinforcement district the under the reinforcement ration in a balanced strain condition.

Stud reinforcement in beam-column joints under seismic loads

  • Abdollahzadeh, Gholamreza;Ghalani, Saeed Eilbeigi
    • Computers and Concrete
    • /
    • 제18권3호
    • /
    • pp.297-317
    • /
    • 2016
  • Current codes recommend large amounts of shear reinforcement for reinforced concrete beam-column joints that causes significant bar congestion. Increase in congestion of shear reinforcement in joint core (connection zone), leads to increase accomplishment problems. The congestion may also lead to diameter limitations on the beam bars relative to the joint dimensions. Using double headed studs instead of conventional closed hoops in reinforced concrete beam-column joints reduces congestion and ensures easier assembly of the reinforcing cage. The purpose of this research is evaluating the efficiency of the proposed reinforcement. In this way, 10 groups of exterior beam-column joints are modeled. Each group includes 7 specimens by different reinforcing details in their joint core. All specimens are modeled by using of ABAQUS and analyzed subjected to cyclic loading. After verification of analytical modeling with an experimental specimen, 3D nonlinear specimens are modeled and analyzed. Then, the effect of amount and arrangement of headed studs on ductility, performance, ultimate strength and energy absorption has been studied. Based on the results, all joints reinforced with double headed studs represent better performance compared with the joints without shear transverse reinforcement in joints core. The behavior of the former is close to joints reinforced with closed hoops and cross ties according to the seismic design codes. By adjusting the arrangement of double-headed studs, the decrease in ductility, performance, ultimate moment resistant and energy absorption reduce to 2.61%, 0.90%, 0.90% and 1.66% respectively compared with the joints reinforced by closed hoops on the average. Since the use of headed studs reduces accomplishment problems, these amounts are negligible. Therefore, use of double-headed studs has proved to be a viable option for reinforcing exterior beam-column joints.

다중 에이전트 강화학습을 이용한 RC보 최적설계 기술개발 (Development of Optimal Design Technique of RC Beam using Multi-Agent Reinforcement Learning)

  • 강주원;김현수
    • 한국공간구조학회논문집
    • /
    • 제23권2호
    • /
    • pp.29-36
    • /
    • 2023
  • Reinforcement learning (RL) is widely applied to various engineering fields. Especially, RL has shown successful performance for control problems, such as vehicles, robotics, and active structural control system. However, little research on application of RL to optimal structural design has conducted to date. In this study, the possibility of application of RL to structural design of reinforced concrete (RC) beam was investigated. The example of RC beam structural design problem introduced in previous study was used for comparative study. Deep q-network (DQN) is a famous RL algorithm presenting good performance in the discrete action space and thus it was used in this study. The action of DQN agent is required to represent design variables of RC beam. However, the number of design variables of RC beam is too many to represent by the action of conventional DQN. To solve this problem, multi-agent DQN was used in this study. For more effective reinforcement learning process, DDQN (Double Q-Learning) that is an advanced version of a conventional DQN was employed. The multi-agent of DDQN was trained for optimal structural design of RC beam to satisfy American Concrete Institute (318) without any hand-labeled dataset. Five agents of DDQN provides actions for beam with, beam depth, main rebar size, number of main rebar, and shear stirrup size, respectively. Five agents of DDQN were trained for 10,000 episodes and the performance of the multi-agent of DDQN was evaluated with 100 test design cases. This study shows that the multi-agent DDQN algorithm can provide successfully structural design results of RC beam.

대각철근을 갖는 고성능 섬유보강 시멘트 복합체 연결보의 이력거동 평가 (Cyclic Behavior of High-Performance Fiber-Reinforced Cement Composite Coupling Beam Having Diagonal Reinforcement)

  • 권현욱;전용률;이기학;신명수;한상환
    • 콘크리트학회논문집
    • /
    • 제25권6호
    • /
    • pp.649-656
    • /
    • 2013
  • 병렬전단벽시스템은 경제적이고 효율적인 구조시스템이지만, 연결보의 복잡한 철근상세가 요구된다. 이를 보완하고자 ACI-318에서는 개선된 철근상세를 제안하고 있지만 과도한 횡보강근으로 현장 적용에 어려움이 따른다. 이 연구에서는 횡보강 철근량을 감소시킨 대각철근을 갖는 HPFRCC 연결보 상세를 제안하고, 형상비 2.0 실험체를 통해 현행 기준에 만족하는 대각철근을 갖는 철근콘크리트 연결보와 이력거동을 비교 평가하였다. 그 결과, HPFRCC의 횡구속 효과를 확인하였고, 횡구속 철근을 기준의 1/2로 배근하고 HPFRCC로 보강한 연결보는 현행기준에 따른 연결보와 유사한 내진성능을 보였다. HPFRCC 보강을 통해 대각보강된 철근콘크리트 연결보의 횡구속 철근량을 감소시킴으로써 철근상세의 단순화가 가능할 것으로 판단된다.

기둥의 철근비와 축변형량이 보 해석에 미치는 영향 연구 (Effect of Longitudinal Reinforcement Ratios and Axial Deformation on Frame Analysis in RC Columns)

  • 장원석;민창식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.477-482
    • /
    • 2001
  • This paper is to study the effect of longitudinal reinforcement ratios and axial deformation on the frame analysis in reinforced concrete(RC) columns and to investigate the effect of confined concrete core, the length-width ratio and longitudinal steel ratios on frame analysis in Concrete-Filled steel Tubular(CFT) columns. An equation if derived to evaluate the modulus of elasticity for core concrete. The 34 reference data have been collected for the purpose and are processed by the mean of a multiple regression analysis technique. The equation and longitudinal reinforcement ratios was applied to RC columns for structural analysis. Then, the difference of beam moment was identified. In general, the results of analysis was indicated reasonable differences in beam moment, in case of longitudinal reinforcement ratios applied to RC columns when compared with the plain concrete columns. In CFT columns the equation was also applied in order to the effect of confined concrete core on structural analysis. Beam moment was increased as volumetric ratio of lateral steel was decreased. The effect of longitudinal steel ratios was investigated in CFT columns and was confirmed beam moment variety. The result was appeared reasonable difference in beam moment as longitudinal steel was increased.

  • PDF