• Title/Summary/Keyword: beam quality

Search Result 1,051, Processing Time 0.028 seconds

Comparison and Analysis of Photon Beam Data for Hospitals in Korea and Data for Quality Assurance of Treatment Planning System (국내 의료기관들의 광자 빔 데이터의 비교 분석 및 치료계획 시스템 정도관리자료)

  • Lee, Re-Na;Cho, Byung-Chul;Kang, Sei-Kwon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.179-186
    • /
    • 2006
  • Purpose: Photon beam data of linear accelerators in Korea are collected, analyzed, and a simple method for checking and verifying the dose calculations in a TPS are suggested. Materials and Methods: Photon beam data such as output calibration condition, output factor, wedge factor, percent depth dose, beam profile, and beam quality were collected from 26 institutions in Korea. In order to verify the accuracy of dose calculation, ten sample planning tests were peformed. These Include square, elongated, and blocked fields, wedge fields, off-axis dose calculation, SSD variation. The planned data were compared to that of manual calculations. Results: The average and standard deviation of photon beam quality for 6, 10, and 15 MV were $0.576{\pm}0.005,\;0.632{\pm}0.004,\;and\;0.647{\pm}0.006$, respectively. The output factors of 6 MV photon beam measured at depth of dose maximum for $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.944{\pm}0.006,\;1.031{\pm}0.006,\;and\;1.055{\pm}0.007$. For 10 MV photon beam, the values were $0.935{\pm}0.006,\;1.031{\pm}0.007,\;1.054{\pm}0.0005$. The collected data were not enough to calculate average, the output factors for 15MV photon beam with field size of $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.941{\pm}0.008,\;1.032{\pm}0.004,\;1.049{\pm}0.014$. There was seven institutions $e{\times}ceeding$ tolerance when monitor unit values calculated from treatment planning system and manually were compared. The measured average MU values for the machines calibrated at SAD setup were 3 MU and 5 MU higher than the machines calibrated at SSD for 6 MV and 10 MV, respectively except the wedge case. When the wedges were inserted, the MU values to deliver 100 cGy to 5 cm depends on manufactures. When the same wedge angle was used, Siemens machine requires more MUs then Varian machine. Conclusion: In this study, photon beam data are collected and analyzed to provide a baseline value for chocking beam data and the accuracy of dose calculation for a treatment planning system.

  • PDF

A study of characteristics for Image sticking in AC - Plasma Display Panel

  • Han, Yong-gyu;Lee, S.B.;Jeong, S.H.;Son, C.G.;Yoo, N.L.;Lee, H.J.;Lim, J.E.;Lee, J.H.;Jeoung, J.M.;Ko, B.D.;Oh, P.Y.;Moon, M.W.;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.263-265
    • /
    • 2005
  • In the alternative current plasma display panel(AC-PDP) technology, it is very important to remove the image sticking for improving an image quality. In this paper, we have investigated the driving method of alternative current plasma display panel(AC-PDP) for preventing image sticking. We have investigated the driving method of alternative current plasma display panel(AC-PDP) for preventing image sticking. The preventing method of image sticking was proposed by adopting the Sticking Remove Pulse(SRP). The variation of brightness is most affected by the MgO to be formed at the surface of the phosphor layer. As a result, the image sticking is reduced when the driving method adopted an SRP.

  • PDF

Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

  • Lee, Seung Kyu;Chang, Insu;Kim, Sang In;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul;Kim, Min Chae
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.72-78
    • /
    • 2019
  • Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system, beam alignment as well as the verification of beam qualities was conducted. Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber. Results and Discussion: Beam alignment was performed in three steps, and collimators and other components were arranged to maintain the uniformity of the mean air kerma rate within ${\pm}2.5%$ at the effective beam diameter of 28 cm. The beam quality was verified by using half-value layer measurement methods specified by American National Standard Institute (ANSI) N13.11-2009 and International Organization for Standardization (ISO)-4037. For each of the nine beams than can be generated by the new X-ray irradiation system, air kerma rates for X-ray fields of different beam qualifies were measured. The results showed that each air kerma rate and homogeneity coefficient of the first and second half-value layers were within ${\pm}5%$ of the recommended values in the standard documents. Conclusion: The results showed that the new X-ray irradiation system provides beam qualities that are as high as moderate beam qualities offered by National Institute of Standards and Technology in ANSI N13.11-2009 and those for narrow-spectrum series of ISO-4037.

Control and Monitoring of Wavelengths in Spectral Beam Combining System Based on High Resolution Camera (고해상도 카메라 기반 파장 빔 결합 시스템의 다중 광원의 모니터링과 파장 제어 기법 연구)

  • Seung, Ji Hoon;Lee, Kwang Hyun;Lee, Jung Hwan
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.14 no.6
    • /
    • pp.321-327
    • /
    • 2019
  • Spectral Beam Combining (SBC) is used for a high-power fiber laser in order to overcome the power limitation of single fiber laser. In SBC, several laser bwams with different wavelengths are combined to obtain a single-aperture beam by diffraction grating. The combining efficiency is dependent on a linewidth, beam quality and specific wavelength of each beam among others. In this paper, we consider the method of a wavelength monitoring and a feedback control of laser diodes used as seeds of laser beams to obtain optimum combining conditions. In order to measure the wavelengths of multi-beam, we use the high resolution camera and diffraction grating with 1,800l/mm. The experiment results show the possibility of feedback control of a current and temperature of multi-seed laser diodes to obtain optimum wavelengths for SBC.

Change of Sprouting-related Enzymes Activities and Food Quality Characteristics of Sweetpotato Root (Ipomea batatas Lam.) by Electron Beam Irradiation (전자빔 조사에 의한 고구마의 발아관련 효소의 활성과 식품특성 변화)

  • Lim, Sung Jin;Song, Mi Seon;Lee, Gyeong Ae;Cho, Jae-Young
    • Journal of Applied Biological Chemistry
    • /
    • v.55 no.4
    • /
    • pp.267-272
    • /
    • 2012
  • We investigated that electron beam irradiation is the effective method to control the sprouting of sweetpotato roots without changing of food quality characteristics. In 12 and $25^{\circ}C$ storage after electron beam irradiation, all control samples were sprouted from 6 and 4 weeks after storage, respectively. The sprouting rate of control increased with time and the rate reached to 11.2-12.4 and 70.5-74.2% at 8 weeks after 12 and $25^{\circ}C$ storage. Also, the sprouting of middle and below positioning sweetpotato roots at 12 and $25^{\circ}C$ storage after irradiation reached to 8.6-11.3 and 42.7-48.7% after a storage period of 8 weeks, respectively. However, the sprouting of all sweetpotato roots stored at $4^{\circ}C$ and upper (0-7 cm) positioning samples of box stored at 12 and $25^{\circ}C$ with electron beam was completely inhibited due to increase peroxidase and indole acetic acid (IAA) oxidase activity. Also, all samples with electron beam such as hardness, pH, sugar content, weight loss, and vitamin C and dacarotene content did not differ from that of the control. Therefore, if electron beam will be irradiated to sweetpotato roots above 0.1 kGy before packing, it will effectively inhibit their sprouting stored at $25^{\circ}C$ without the change of food quality characteristics.

Quality Assurance System for Determination of Center Position in X-ray and Proton Irradiation Fields using a Stainless Ball and Imaging Plates in Proton Therapy at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.189-191
    • /
    • 2002
  • In the proton therapy using a gantry system, periodical verification of iso-center position is very important to assure precision of patient positioning system at any gantry angles in proton treatment. In the gantry system, there are three different types of iso-center; 1) in a geometrical view, 2) in an X-ray beam's eye view, 3) in a proton beam's eye view. Idealistically, they would be an identical point. They could, however, be different points. It may be a source of errors in patient positioning. At PMRC, we have established a system of verification for iso-center positions using a stainless ball of 2-cm in diameter and an imaging plate. This system provides the relation among a center of a patient target position, a center of proton irradiation field, and/or a center of X-ray field in accuracy of 50$\square$m in the 2) and 3) views, as images of a center of the stainless ball and a center of a 100 mm${\times}$100 mm-aperture brass collimator recorded on the imaging plate, which is setup at 1-cm behind the ball. In addition, it provides simultaneously the images of the ball and the collimator on an imaging intensifier (II), which is setup downstream of the proton or X-ray beam. We present a method of quality assurance (QA) for calibration of iso-center position in a rotation gantry system at PMRC and the performance of this system. A proton beam position on the 1$\^$st/ scatterer in the nozzle of the gantry affects less sensitive (reduced by a factor of 1/5) to the results of the iso-center position. The effect is systematically correctable. The effect of the nozzle (or the collimator) position is less than 0.5 mm at the maximum extraction (390 mm).

  • PDF

Alignment and lattice quality of hexagonal rings of hexagonal BN films synthesized by ion beam assisted deposition (이온빔보조증착법으로 합성한 hexagonal BN막의 hexagonal ring의 배열과 결정성)

  • 박영준;한준희;이정용;백영준
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.1
    • /
    • pp.43-50
    • /
    • 1999
  • We have studied the alignment and the lattice quality of hexagonal rings of h-BN films synthesized by ion beam assisted deposition (IBAD) method. Boron was e-beam evaporated at 1.5 $\AA$/sec and nitrogen gas was ionized using end-hall type ion gun at 60, 80, and 100 eV, respectively. Substrate was either not heated or heated at 200, 400, 500, and $800^{\circ}C$, respectively. As nitrogen ion energy increases, c-axes of hexagonal rings tend to align parallel to the substrate, which is explained by larger compressive stress at higher ion energies. Alignment of c-axis increases with temperature and shows maximum around $400^{\circ}C$. The lattice quality of hexagonal rings improves with temperature. Such behaviors can be understood from two counter trends of increasing the atomic mobility and decreasing compressive stress with temperature. Hardness of h-BN films shows the same trend with the alignment of c-axis. Ion beam assisted deposition method seems to be effective for aligning hexagonal rings and optimizing h-BN properties.

  • PDF

Safety and Economic Analysis by Applying HI-BEAM Technology (HI-BEAM 공법 적용 시 안전성 및 경제성 분석 연구)

  • Kim, sul min;Son, Kiyoung
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.2 no.1
    • /
    • pp.21-27
    • /
    • 2019
  • Hybrid & Integrated Beam (HI-BEAM), one of the composite systems, appears to have the advantage of high rigidity of reinforced concrete structures and long span of steel structures. In addition, because HI-BEAM makes the ends of beams from reinforced concrete, it is able to construct ideal composite construction method for effectively joining with reinforced concrete columns and can produce high-quality concrete structures without completing them in the field. Existing studies on the HI-BEAM method are mostly studies on structural aspects or epidemiological characteristics, or studies on the productivity and cost analysis of different structures through case studies, and analysis of actual construction methods is based on actual construction sites. In this study, the economic feasibility of the HI-BEAM method is verified by comparing the productivity and construction costs of the RC-BEAM method (RC-BEAM) method and the HI-BEAM method.