• Title/Summary/Keyword: beam measurement

Search Result 1,542, Processing Time 0.032 seconds

Measurement of Crack Length by Ultrasonic Attenuation Coefficient (초음파 감쇠계수에 의한 균열길이의 측정)

  • Chung, Nam-Yong;Park, Sung-Il
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.340-345
    • /
    • 2003
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the relation between crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the results of experiments, the measurement method of crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF

Study of measurement system for E-beam focus position compensation (전자빔 가공 포커스 위치 보정용 측정기구에 관한 기초연구)

  • Ha T.H.;Song E.J.;Lee C.W.;Song J.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.273-274
    • /
    • 2006
  • Fundamental research is conducted in order to develop measurement system for E-beam focus position compensation. In this paper, simulation results using Fresnel's formula shows effect of photoresist film thickness according to incident conditions. Also, electromagnetic simulator is developed based on Boundary Element method (BEM) and several results confirm the feasibility of the simulator.

  • PDF

Measurement Method of Linear Expansion Coefficient for Solid Matter using Michelson Interferometer (Michelson 간섭계에 의한 고체의 선팽창계수 측정방법)

  • Kim, Hong-Gyun;Kim, Young-Sun
    • Journal of Engineering Education Research
    • /
    • v.16 no.2
    • /
    • pp.24-30
    • /
    • 2013
  • This paper deals with the measurement theory and technique of linear expansion coefficient for solid material using Michelson interferometer. The Michelson interferometer produces interference fringes by splitting a beam of monochromatic light so that one beam strikes a fixed mirror and the other a movable mirror. When the reflected beams are brought back together, an interference pattern results. Precise distance measurements until a quarter of wave length can be made with the Michelson interferometer by moving the mirror and counting the interference fringes which move by a photo diode. This paper represents the application of Michelson interferometer for measuring infinitesimal length system and shows the measurement method of linear expansion coefficients for various materials like copper, aluminum and iron. the results are good agreement with theoretical value within margin of error for each materials.

A Method of Wood Section Measuring and the Image Calibration Using Line Laser (Line Laser 를 이용한 목재단면 측정 및 영상보정 방법)

  • Kim, Gi Hwan;Park, Min Su;Kim, Do Yeop;Lee, Suk Yong;Lee, Eung Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.8
    • /
    • pp.641-646
    • /
    • 2016
  • The best method of measuring wood diameter is a contact-type device: however, obtaining an accurate result can be problematic under certain circumstances. In this study, we used a laser beam and a CCD camera that did not require contact with wood. The wood is illuminated by the laser beam, and the CCD camera captures this illumination. The measurement results were determined by processing of the captured image sequences. This paper explains the use of image processing and laser systems for measurement of wood under circumstances in which physical contact is impossible.

Measurement of Interfacial Crack Length by Ultrasonic Attenuation Coefficients on Adhesively Bonded Components (접착부재의 초음파 감쇠계수에 의한 계면균열 길이의 측정)

  • 정남용;박성일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.130-137
    • /
    • 2004
  • The ultrasonic attenuation coefficients were measured by interfacial crack length in the adhesive components of double-cantilever beam(DCB). The energy release rate, G, was obtained by the experimental measurement of compliance. The numerical analysis by the boundary element method(BEM) and Ripling's equation was investigated. The experimental results represent that the relation between interfacial crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. A measurement method of the interfacial crack length by the ultrasonic attenuation coefficient was proposed and discussed.

Estimation of Vibration-damping Properties for Steel Beam (Steel beam의 진동감쇠 특성평가)

  • Shin, Su-Hyun;Nam, Hyo-Duk;Jung, Sung-Soo;Lee, Young-Bong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.439-442
    • /
    • 2003
  • The test method of ASTM E 756 and JIS G 0602 to estimate vibration-damping properties is presented. Measurement method depending on specimen support, exciting method and calculation method for loss factor is used. Half-power bandwidth method and vibration decay method is used in the calculation method for loss factor, and Young's modulus is decided by geometric character and density for specimen and resonance frequency. Vibration measurement sensor is compared by using non-contact displacement detector, velocity detector and accelerometer. The cause of measurement error is also presented.

  • PDF

Reliability of two different presurgical preparation methods for implant dentistry based on panoramic radiography and cone-beam computed tomography in cadavers

  • Hu, Kyung-Seok;Choi, Da-Yae;Lee, Won-Jae;Kim, Hee-Jin;Jung, Ui-Won;Kim, Sung-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.2
    • /
    • pp.39-44
    • /
    • 2012
  • Purpose: Special care is necessary to avoid invading important anatomic structures during surgery when presurgical planning is made based on radiographs. However, none of these types of radiography represents a perfect modality. The purpose of this study was to determine the reliability of presurgical planning based on the use of two types of radiographic image (digital panoramic radiography [DPR] and cone-beam computed tomography [CBCT]) by beginner dentists to place implants, and to quantify differences in measurements between radiographic images and real specimens. Methods: Ten fresh cadavers without posterior teeth were used, and twelve practitioners who had no experience of implant surgery performed implant surgery after 10 hours of basic instruction using conventional surgical guide based on CBCT or DPR. Two types of measurement error were evaluated: 1) the presurgical measurement error, defined as that between the presurgical and postsurgical measurements in each modality of radiographic analysis, and 2) the measurement error between postsurgical radiography and the real specimen. Results: The mean presurgical measurement error was significantly smaller for CBCT than for DPR in the maxillary region, whereas it did not differ significantly between the two imaging modalities in the mandibular region. The mean measurement error between radiography and real specimens was significantly smaller for CBCT than for DPR in the maxillary region, but did not differ significantly in the mandibular region. Conclusions: Presurgical planning can be performed safely using DPR in the mandible; however, presurgical planning using CBCT is recommended in the maxilla when a structure in a buccolingual location needs to be evaluated because this imaging modality supplies buccolingual information that cannot be obtained from DPR.

Tackling range uncertainty in proton therapy: Development and evaluation of a new multi-slit prompt-gamma camera (MSPGC) system

  • Youngmo Ku;Sehoon Choi;Jaeho Cho;Sehyun Jang;Jong Hwi Jeong;Sung Hun Kim;Sungkoo Cho;Chan Hyeong Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3140-3149
    • /
    • 2023
  • In theory, the sharp dose falloff at the distal end of a proton beam allows for high conformal dose to the target. However, conformity has not been fully achieved in practice, primarily due to beam range uncertainty, which is approximately 4% and varies slightly across institutions. To address this issue, we developed a new range verification system prototype: a multi-slit prompt-gamma camera (MSPGC). This system features high prompt-gamma detection sensitivity, an advanced range estimation algorithm, and a precise camera positioning system. We evaluated the range measurement precision of the prototype for single spot beams with varying energies, proton quantities, and positions, as well as for spot-scanning proton beams in a simulated SSPT treatment using a phantom. Our results demonstrated high accuracy (<0.4 mm) in range measurement for the tested beam energies and positions. Measurement precision increased significantly with the number of protons, achieving 1% precision with 5 × 108 protons. For spot-scanning proton beams, the prototype ensured more than 5 × 108 protons per spot with a 7 mm or larger spot aggregation, achieving 1% range measurement precision. Based on these findings, we anticipate that the clinical application of the new prototype will reduce range uncertainty (currently approximately 4%) to 1% or less.

Design of range measurement systems using a sonar and a camera (초음파 센서와 카메라를 이용한 거리측정 시스템 설계)

  • Moon, Chang-Soo;Do, Yong-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.116-124
    • /
    • 2005
  • In this paper range measurement systems are designed using an ultrasonic sensor and a camera. An ultrasonic sensor provides the range measurement to a target quickly and simply but its low resolution is a disadvantage. We tackle this problem by employing a camera. Instead using a stereoscopic sensor, which is widely used for 3D sensing but requires a computationally intensive stereo matching, the range is measured by focusing and structured lighting. In focusing a straightforward focusing measure named as MMDH(min-max difference in histogram) is proposed and compared with existing techniques. In the method of structure lighting, light stripes projected by a beam projector are used. Compared to those using a laser beam projector, the designed system can be constructed easily in a low-budget. The system equation is derived by analysing the sensor geometry. A sensing scenario using the systems designed is in two steps. First, when better accuracy is required, measurements by ultrasonic sensing and focusing of a camera are fused by MLE(maximum likelihood estimation). Second, when the target is in a range of particular interest, a range map of the target scene is obtained by using structured lighting technique. The systems designed showed measurement accuracy up to 0.3[mm] approximately in experiments.

Measurement of the Relative Phase Fluctuation by Multiport-Homodyne Detection Method (Multiport-Homodyne 측정 방법에 의한 광신호의 상대적 위상 변화에 대한 연구)

  • 최준홍
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.242-247
    • /
    • 1990
  • By self-homodyne method we measured the relative phase fluctuation of a light wave. Balanced detection system can eliminate local oscillator excess noise and multiport detection makes it possible ot measure the phase change of the signal beam. Deriving the SB(Signal Beam) and the LO(Local Oscillator) from the same laser source, we find the SB maintain constant phase relative to that of the LO. We have introduced a phase fluctuation in the SB by modulating the beam path of the SB. The measured phase fluctuation agreed well with the predicted one, thereby we confirmed the reliability of our system.

  • PDF