• Title/Summary/Keyword: beam analysis

Search Result 6,186, Processing Time 0.033 seconds

Three-dimensional finite element analysis of initial tooth displacement according to force application point during maxillary six anterior teeth retraction using skeletal anchorage (골격성 고정원을 이용한 상악 6전치 후방 견인시 힘의 적용점 변화에 따른 치아 이동 양상에 관한 유한 요소법적 분석)

  • Kim, Chan-Nyeon;Sung, Jae-Hyun;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.33 no.5 s.100
    • /
    • pp.339-350
    • /
    • 2003
  • The purpose of this study was to investigate the micro-implant height and anterior hook height to prevent maxillary six anterior teeth from lingual tipping and extruding during space closure. We manufactured maxillary dental arch form, bracket and wire, using the computer aided three-dimensional finite element method. Bracket was $.022'{\times}.028'$ slot size and attached to tooth surface. Wire was $.019'{\times}.025'$ stainless steel and $.032'{\times}.032'$ stainless steel hook was attached to wire between lateral incisor and canine. Length of hook was 8mm and force application points were marked at intervals of In. Four micro-implants were implanted on alveolar bone between second premolar and first molar. The heights of them were 4, 6, 8, 10mm starting from wire. We analyzed initial displacement of teeth by various force application point applying force of 150gm to each micro-implant and anterior hook. The conclusions of 4his study are as the following : 1. When the micro-implant height was 4m and the anterior hook height was 5mm and below, anterior teeth were tipped lingually. When the anterior hook height was 6mm and above, anterior teeth were tipped labially. 2. When the micro-implant height was 6mm and the anterior hook height was 6mm and below, the anterior teeth were tipped lingually. When the anterior hook height was 6m and above, the anterior teeth were tipped labially. But lingual tipping of anterior teeth decreased and labial tipping Increased when the micro-implant height was 6mm, compared with 4mm micro-implant height. 3. When the micro-implant height was 8mm and the anterior hook height was 2mm, the anterior teeth were tipped lingually. When the anterior hook height was 3mm and above, labial tipping movement of the anterior teeth increased proportionally. 4. When the micro-implant height was 10mm and the anterior hook height was 2mm and above, labial tipping of the anterior teeth increased proportionally. 5. As the anterior hook height increased, aterior teeth were tipped more labially. But extrusion occurred on canine and premolar area because of the increase of wire distortion. 6. Movement of the posterior teeth was tipped distally during maxillary six anterior teeth retraction using micro-im plant because of the friction between bracket and were Based on the results of this study, we could predict the pattern of the tooth movement according to position of micro-implant and height of anterior hook. It seems that we can find the force application point for proper tooth movement in consideration of inclination of anterior anterior teeth, periodontal condition, overjet and overbite

Investigation of the Earth Science Teacher Education Programs in the College of Education and their Improvement Plans (사범대학 지구과학 교사 양성 교육 과정 현황 분석 및 개선 방안 탐색)

  • Kim, Jong-Hee;Lee, Ki-Young
    • Journal of the Korean earth science society
    • /
    • v.27 no.4
    • /
    • pp.390-400
    • /
    • 2006
  • The purpose of this study is to propose an improvement plan based on an analysis of the current earth science teacher education curriculum in the department of education in the four fields of teaching profession theory: student-teacher practice, subject lesson education, and subject content education. The following are the conclusions and suggestions of this study. In case of teaching profession theory, too much emphasis is put on pedagogical theory over practical issues, and a problem arises upon completion. Therefore, it is sugguest that teaching profession theory might be completed before subject lesson education to ensure more authentic subjects performing teaching profession. The current term for student-teacher training is too short to understand the whole school system. Current school system does not have any off-job training course or internship system. Therefore, student-teacher training term should be increased by at least $3{\sim}6$ months to play a vital role in the current system. The credit number of subject lesson education is too small compared with subject content education. Consequently, the credit number of subject lesson education should be increased, and more professor majored in subject lesson education should be recruited. Significant deviation between the content of subject content education and that of middle school grade exists, and there is also much difference in the ratio of subject according to university. To get rid of these problems, subject content education should be connected with subject lesson education and appropriate number of credit needs to be assigned to each subject domain.

Analysis of Optical Characteristic Near the Cloud Base of Before Precipitation Over the Yeongdong Region in Winter (영동지역 겨울철 스캔라이다로 관측된 강수 이전 운저 인근 수상체의 광학 특성 분석)

  • Nam, Hyoung-Gu;Kim, Yoo-Jun;Kim, Seon-Jeong;Lee, Jin-Hwa;Kim, Geon-Tea;An, Bo-Yeong;Shim, Jae-Kwan;Jeon, Gye-hak;Choi, Byoung-Choel;Kim, Byung-Gon
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.2_1
    • /
    • pp.237-248
    • /
    • 2018
  • The vertical distribution of hydrometeor before precipitation near the cloud base has been analyzed using a scanning lidar, rawinsonde data, and Cloud-Resolving Storm Simulator (CReSS). This study mostly focuses on 13 Desember 2016 only. The typical synoptic pattern of lake-effect snowstorm induced easterly in the Yeongdong region. Clouds generated due to high temperature difference between 850 hPa and sea surface (SST) penentrated in the Yeongdong region along with northerly and northeasterly, which eventually resulted precipitation. The cloud base height before the precipitation changed from 750 m to 1,280 m, which was in agreement with that from ceilometer at Sokcho. However, ceilometer tended to detect the cloud base 50 m ~ 100 m below strong signal of lidar backscattering coefficient. As a result, the depolarization ratio increased vertically while the backscattering coefficient decreased about 1,010 m~1,200 m above the ground. Lidar signal might be interpreted to be attenuated with the penetration depth of the cloud layer with of nonspherical hydrometeor (snow, ice cloud). An increase in backscattering signal and a decrease in depolarization ratio occured in the layer of 800 to 1,010 m, probably being associated with an increase in non-spherical particles. There seemed to be a shallow liquid layer with a low depolarization ratio (<0.1) in the layer of 850~900 m. As the altitude increases in the 680 m~850 m, the backscattering coefficient and depolarization ratio increase at the same time. In this range of height, the maximum value (0.6) is displayed. Such a result can be inferred that the nonspherical hydrometeor are distributed by a low density. At this time, the depolarization ratio and the backscattering coefficient did not increase under observed melting layer of 680 m. The lidar has a disadvantage that it is difficult for its beam to penetrate deep into clouds due to attenuation problem. However it is promising to distinguish hydrometeor morphology by utilizing the depolarization ratio and the backscattering coefficient, since its vertical high resolution (2.5 m) enable us to analyze detailed cloud microphysics. It would contribute to understanding cloud microphysics of cold clouds and snowfall when remote sensings including lidar, radar, and in-situ measurements could be timely utilized altogether.

Studies on Estimation of Fish Abundance Using an Echo Sounder ( 2 ) - The Relationship between Acoustic Backscattering Strength and Distribution Density of Fish in a Net Cage- (어군탐지기에 의한 어군량 추정에 관한 기초적 연구 ( 2 ) - 어군의 분포밀도와 초음파산란강도의 관계 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.1
    • /
    • pp.13-20
    • /
    • 1991
  • This paper describes the fish-density dependence of the mean backscattering strength with aggregations of encaged, free-swimming fish of known density in relation to the experimental verification of echo-integration technique for estimating the density of fish shoals. In this experiment, various numbers of gold crussian, Carassius burgeri burgeri, with a mean length of 18.5cm and a mean weight of 205.9g, were introduced into a net cage of approximately 0.76m super(3). During the backscattering measurements. the cage was suspended on the sound axis of the 50kHz transducer having a beam width of 33 degrees at -3dB downpoints. The volume backscattering strengths from fish aggregations were measured as a function of fish density. Data acquisition, processing and analysis were performed by means of the microcomputer-based sonar-echo processor including a FFT analyzer. The calibration of echo-sounder system was carried out at field with a steel ball bearing of 38mm in diameter having the target strength of -40.8dB. The dorsal-aspect target strengths on anesthetized specimens of gold crussian used in the cage experiment were measured and compared with the target strength predicted by the fish density-echo energy relationship for aggregations of free-swimming gold crussian in the cage. The results obtained can be summarized as follows: 1. The target strengths in the dorsal aspect on anesthetized specimens of gold crussian, with the mean length of 19.1cm and the mean weight of 210.5g, varied from -40.9dB to -44.8dB with a mean of -42.6dB. This mean target strength did not differ significantly from that predicted by the regression of echo energy on fish density of free-swimming gold crussian in the cage. It suggests that the target-strength measurements on anesthetized fish was valid and can be representative for live, free-swimming fish. 2. The relationship between mean backscattering strength(, dB) and distribution density of gold $crussian(\rho, $ fish/m super(3)) was expressed by the following equation; =-41.9+11 $Log(\rho)$ with a correlation coefficient of 0.97. This result support the existence of a linear relationship between fish density and echo energy, but suggest that this line has steeper slope than the regression by the theory of estimating the density of fish schools.

  • PDF

Evaluation of the Breast plan using the TLD and Mosfet for the skin dose (열형광선량계(TLD)와 MOSFET을 이용한 유방암 방사선치료계획에 대한 피부선량 평가)

  • Kim, seon myeong;Kim, young bum;Bak, sang yun;Lee, sang rok;Jeong, se young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.107-113
    • /
    • 2015
  • Purpose : The measurement of skin dose is very important that treatment of breast cancer. On account of the cold or hot dose as compared with prescription dose, it is necessary to analyse the skin dose occurring during the various plan of the breast cancer treatment. At our hospital, we want to apply various analyses using a diversity of dosimeters to the breast cancer treatment. Subjectss and Methods : In the study, the anthropomorphic phantom is used to find out the dose difference of the skin(draining site), scar and others occurring from the tangential treatment plan of breast cancer. We took computed tomography scan of the anthropomorphic phantom and made plans for the treatment planing using open and wedge, Field-in-Field, Dose fluence. Using these, we made a comparative analysis of the dose date points by using the Eclipse. For the dose comparison, we place the anthropomorphic phantom in the treatment room and compared the measurement results by using the TLD and MOSFET on the dose data points. Results : On the central point of treatment planing basis, the upward and downward skin dose measured by the MOSFET was the highest when the fluence was used. The skin dose of inner and outer was distinguished from the figure(5.7% ~ 10.3%) when the measurements were fulfilled by using TLD and MOSFET. The other side of breast dose was the lowest in the open beam, on the other hand, is highest in the Dose fluence plan. In the different kinds of treatment, the dose deviation of inner and outer was the highest, and so this was the same with the TLD and MOSFET measurement case. The outer deviation was highest in the TLD, and the Inner'was highest in the MOSFET. Conclusion : Skin dose in relation to the treatment plan was the highest in the planing using the fluence technique in general and it was supposed that the high dose had been caused by the movement of the MLC. There's some differences among the all the treatment planning, but the sites such as IM node occurring the lack of dose, scar, drain site are needed pay close attention. Using the treatment planning of dose fluence is good to compensate the lack of dose, but It increases the dose of the selective range rather than the overall dose. Therefore, choosing the radiotherapy technique is desirable in the lights of the age and performance of the patient.

  • PDF

EFFECT OF CHLORHEXIDINE ON MICROTENSILE BOND STRENGTH OF DENTIN BONDING SYSTEMS (Chlorhexidine 처리가 상아질 접착제의 미세인장결합강도에 미치는 영향)

  • Oh, Eun-Hwa;Choi, Kyoung-Kyu;Kim, Jong-Ryul;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.148-161
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of chlorhexidine (CHX) on microtensile bond strength (${\mu}TBS$) of dentin bonding systems. Dentin collagenolytic and gelatinolytic activities can be suppressed by protease inhibitors, indicating that MMPs (Matrix metalloproteinases) inhibition could be beneficial in the preservation of hybrid layers. Chlorhexidine (CHX) is known as an inhibitor of MMPs activity in vitro. The experiment was proceeded as follows: At first, flat occlusal surfaces were prepared on mid-coronal dentin of extracted third molars. GI (Glass Ionomer) group was treated with dentin conditioner, and then, applied with 2 % CHX. Both SM (Scotchbond Multipurpose) and SB (Single Bond) group were applied with CHX after acid-etched with 37% phosphoric acid. TS (Clearfil Tri-S) group was applied with CHX, and then, with adhesives. Hybrid composite Z-250 and resin-modified glass ionomer Fuji-II LC was built up on experimental dentin surfaces. Half of them were subjected to 10,000 thermocycle, while the others were tested immediately. With the resulting data, statistically two-way ANOVA was performed to assess the ${\mu}TBS$ before and after thermo cycling and the effect of CHX. All statistical tests were carried out at the 95 % level of confidence. The failure mode of the testing samples was observed under a scanning electron microscopy (SEM). Within limited results, the results of this study were as follows; 1. In all experimental groups applied with 2 % chlorhexidine, the microtensile bond strength increased, and thermo cycling decreased the micro tensile bond strength (P > 0.05). 2. Compared to the thermocycling groups without chlorhexidine, those with both thermocycling and chlorhexidine showed higher microtensile bond strength, and there was significant difference especially in GI and TS groups. 3. SEM analysis of failure mode distribution revealed the adhesive failure at hybrid layer in most of the specimen. and the shift of the failure site from bottom to top of the hybrid layer with chlorhexidine groups. 2 % chlorhexidine application after acid-etching proved to preserve the durability of the hybrid layer and microtensile bond strength of dentin bonding systems.

Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System (구동팬텀 시스템에 의한 움직이는 장기의 선량분포 분석)

  • Kim, Yon-Lae;Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Lee, Gui-Won;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purpose: Few researches have been peformed on the dose distribution of the moving organ for radiotherapy so far. In order to simulate the organ motion caused by respiratory function, multipurpose phantom and moving device was used and dosimetric measurements for dose distribution of the moving organs were conducted in this study. The purpose of our study was to evaluate how dose distributions are changed due to respiratory motion. Materials and Methods: A multipurpose phantom and a moving device were developed for the measurement of the dose distribution of the moving organ due to respiratory function. Acryl chosen design of the phantom was considered the most obvious choice for phantom material. For construction of the phantom, we used acryl and cork with density of $1.14g/cm^3,\;0.32g/cm^3$ respectively. Acryl and cork slab in the phantom were used to simulate the normal organ and lung respectively. The moving phantom system was composed of moving device, moving control system, and acryl and cork phantom. Gafchromic film and EDR2 film were used to measure dose ditrbutions. The moving device system may be driven by two directional step motors and able to perform 2 dimensional movements (x, z axis), but only 1 dimensional movement(z axis) was used for this study. Results: Larger penumbra was shown in the cork phantom than in the acryl phantom. The dose profile and isodose curve of Gafchromic EBT film were not uniform since the film has small optical density responding to the dose. As the organ motion was increased, the blurrings in penumbra, flatness, and symmetry were increased. Most of measurements of dose distrbutions, Gafchromic EBT film has poor flatness and symmetry than EDR2 film, but both penumbra distributions were more or less comparable. Conclusion: The Gafchromic EBT film is more useful as it does not need development and more radiation dose could be exposed than EDR2 film without losing film characteristics. But as response of the optical density of Gafchromic EBT film to dose is low, beam profiles have more fluctuation at Gafchromic EBT. If the multipurpose phantom and moving device are used for treatment Q.A, and its corrections are made, treatment quality should be improved for the moving organs.

  • PDF

Formation of the $CoSi_{2}$ using Co/Zr Bilayer on the Amorphous and the Single Crystalline Si Substrates (단결정과 비정질 Si 기판에서 Co/Zr 이중층을 이용한 $CoSi_{2}$ 형성)

  • Kim, Dong-Wook;Jeon, Hyeong-Tag
    • Korean Journal of Materials Research
    • /
    • v.8 no.7
    • /
    • pp.621-627
    • /
    • 1998
  • The formation of Co-silicide between Co/Zr bilayer on the amorphous and crystalline Si substrates has been investigated. The films of Zr(50$\AA$) and Co(l50$\AA$) were deposited with e-beam evaporation system and were heattreated with the rapid thermal annealing system at the temperatures between 50$0^{\circ}C$ and 80$0^{\circ}C$ with 10$0^{\circ}C$ increments for 30 seconds. The phase identification of Co-silicide was carried out by XRD and the chemical analysis was examined by AES and RBS. The interface morphologies of Co/Zr bilayer films were investigated by cross sectional TEM and HRTEM. $CoSi_2$ was formed epitaxially on the crystalline Si substrate above $700^{\circ}C$ while polycrystalline $CoSi_2$ was grown on the amorphous Si substrate. The formation temperature of Co-silicide on the amorphous Si substrate was about 100 C lower than that on the crystalline Si. The COzSi phase was not identified on the both Si substrates. The formation temperature of first phase of Co-silicide on ColZr bilayer was higher than that on Co mono layer. CoSizlayer formed on the amorphous Si substrate exhibits better uniformity compared to the CoSiz formed on the crystalline substrate. The sheet resistance of CoSiz layer on crystalline Si was lower than that on the amorphous Si at high temperatures.tures.

  • PDF

Radiotherapy of Locally Recurrent Rectal Carcinoma (수술 후 국소재발된 직장암의 방사선치료 결과)

  • Jeong Hyeon Ju;Shin Young Ju;Mo Yang Kwang;Suh Hyun Suk;Chun Hachung;Lee Myung Za
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.36-41
    • /
    • 1999
  • Purpose : We reviewed the treatment results for the patients with locally recurrent rectal carcinoma. The object was to evaluate the treatment outcome and to identify the prognostic factors influencing the survival. Methods and Materials: Twenty-eight patients with locally recurrent rectal carcinoma treated principally with external-beam radiation therapy between 1982 to 1996 in the Department of Radiation Oncology at Paik and Hanyang Hospital were reviewed retrospectively Of these, 17 patients had initially abdominoperineal resection, 9 had low anterior resection, and 2 had local excision. No patients had received adjuvant radiation therapy for the primary disease. There were 14 men and 14 women whose ages ranged from 31 to 72 years (median age:54.5). Median time from initial surgery to the start of radiation therapy for local recurrence was 11 months (4~47 months). Radiation therapy was given with total doses ranging from 27 to 64.8 Gy (median=51.2 Gy). Results : The median survival was 16.7 months. The 2-year and 5-year survival rates were 20.1%, 4.1% respectively. Upon multivariate analysis, overall survival was positively correlated with duration of intervals from initial surgery to local recurrence (P=0.039). Relief of pelvic symptoms was achieved in 17 of 28 patients (60.7%). Pain and bleeding responded in 40% and 100% of patients, respectively Conclusions : Patients with locally recurrent rectal carcinoma treated with radiotherapy have benefited symptomatically, and might have increased survivals with a small chance of cure. But, patient were rarely cured (median survival : 10 months, 5-year survival : less than 5%). Overall survival was positively correlated with long intervals from initial surgery to local recurrence. Future efforts should be directed to the use of effective therapy for patients with locally recurrent rectal carcinoma and adjuvant therapy for patients with rectal cancer to reduce the incidence of pelvic recurrence.

  • PDF

Prediction of Late Rectal Complication Following High-dose-rate Intracavitary Brachytherapy in Cancer of the Uterine Cervix (자궁경부암 환자의 고선량률 강내치료 시행 시 직장합병증의 예측)

  • Lee, Jeung-Eun;Huh, Seung-Jae;Park, Won;Lim, Do-Hoon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.276-282
    • /
    • 2003
  • Purpose: Although high-dose-rate intracavitary radiotherapy (HDR ICR) has been used in the treatment of cervical cancer, the potential for increased risk of late complication, most commonly in the rectum, is a major concern. We have previously reported on 136 patients treated with HDR brachytherapy between 1995 and 1999. The purpose of this study is to upgrade the previous data and confirm the correlation between late rectal complication and rectal dose in cervix cancer patients treated with HDR ICR. Materials and Methods: A retrospective analysis was peformed for 222 patients with cevix cancer who were treated for curative intent with external beam radiotherapy (EBRT) and HDR ICR from July 1995 to December 2001. The median dose of EBRT was 50.4 (30.6$\~$56.4) Gy with a daily fraction size 1.8 Gy. A total of six fractions of HDR ICR were given twice weekly with fraction size of 4 (3$\~$5.5) Gy to A point by Iridium-192 source. The rectal dose was calculated at the rectal reference point using the barium contrast criteria. in vivo measurement of the rectal dose was peformed with thermoluminescent dosimeter (TLD) during HDR ICR. The median follow-up period was 39 months, ranging from 6 to 90 months. Results: Twenty-one patients (9.5$\%$) experienced late rectal bleeding, from 3 to 44 months (median, 13 months) after the completion of RT. The calculated rectal doses were not different between the patients with rectal bleeding and those without, but the measured rectal doses were higher in the complicated patients. The differences of the measured ICR rectal fractional dose, ICR total rectal dose, and total rectal biologically equivalent dose (BED) were statistically significant. When the measured ICR total rectal dose was beyond 16 Gy, when the ratio of the measured rectal dose to A point dose was beyond 70$\%$, or when the measured rectal BED was over 110 Gy$_{3}$, a high possibility of late rectal complication was found. Conclusion: Late rectal complication was closely correlated with measured rectal dose by in vivo dosimetry using TLD during HDR ICR. If data from in vivo dosimetry shows any possibility of rectal bleeding, efforts should be made to reduce the rectal dose.