• Title/Summary/Keyword: beam analysis

Search Result 6,209, Processing Time 0.034 seconds

On the thermal buckling response of FG Beams using a logarithmic HSDT and Ritz method

  • Kadda Bouhadjeb;Abdelhakim Kaci;Fouad Bourada;Abdelmoumen Anis Bousahla;Abdelouahed Tounsi;Mohammed A. Al-Osta;S.R. Mahmoud;Farouk Yahia Addou
    • Geomechanics and Engineering
    • /
    • v.37 no.5
    • /
    • pp.453-465
    • /
    • 2024
  • This paper presents a logarithmic shear deformation theory to study the thermal buckling response of power-law FG one-dimensional structures in thermal conditions with different boundary conditions. It is assumed that the functionally graded material and thermal properties are supposed to vary smoothly according to a contentious function across the vertical direction of the beams. A P-FG type function is employed to describe the volume fraction of material and thermal properties of the graded (1D) beam. The Ritz model is employed to solve the thermal buckling problems in immovable boundary conditions. The outcomes of the stability analysis of FG beams with temperature-dependent and independent properties are presented. The effects of the thermal loading are considered with three forms of rising: nonlinear, linear and uniform. Numerical results are obtained employing the present logarithmic theory and are verified by comparisons with the other models to check the accuracy of the developed theory. A parametric study was conducted to investigate the effects of various parameters on the critical thermal stability of P-FG beams. These parameters included support type, temperature fields, material distributions, side-to-thickness ratios, and temperature dependency.

Development of Chemical Separation Process for Thallium-201 Radioisotope with Lead Standard Material (납 표준물질을 이용한 방사성동위원소 Thallium-201의 화학적 분리공정 개발)

  • JunYoung Lee;TaeHyun Kim;JeongHoon Park
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.543-549
    • /
    • 2023
  • Thallium-201 (201Tl) is a medical radioisotope which emits gamma rays when it decays and used in myocardial perfusion scans in single-photon emission tomography due to its similar properties to potassium. Currently, the Korea Institute of Radiological & Medical Sciences is the only institution producing 201Tl in Korea, and optimization of 201Tl production research is necessary to meet supply compared to domestic demand. To this end, technical analysis of plating target production and chemical separation methods essential for 201Tl production research is conducted. It deals with the process of generating and separating 201Tl radioisotope and target production, It can be generated through a nuclear reaction such as natHg(p,xn)201Tl, 201Hg(p,n)201Tl, natPb(p,xn)201Bi → 201Pb → 201Tl, 205Tl(p,5n)201Pb → 201Tl, and considering impure nuclide generated simultaneously with the use of proton beam energy of 35 MeV or less, it is intended to be produced using the 203Tl(p,3n)201Pb→201Tl nuclear reaction. In particular, the chemical separation of Tl is a very important element, and the chemical separation methods that can separate it is broadly divided into four types, including solid phase extraction, liquid-liquid, electrochemical, and ion exchange membrane separation. Some chemical separations require additional separation steps, such as methods using selective adsorption. Therefore, this technical report describes four chemical separation methods and seeks to separate high-purity 201Tl using a method without additional separation steps

Applicability of Partial Post-Tension Method for Deflection Control of Reinforced Concrete Slabs (RC슬래브의 처짐제어를 위한 상향긴장식 부분PT공법의 적용)

  • Lee, Deuck-Hang;Kim, Kang-Su;Kim, Sang-Sik;Kim, Yong-Nam;Lim, Joo-Hyuk
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.347-358
    • /
    • 2009
  • Recently, it is getting into a good situation for the flat-plate slab system to be applied. The flat-plate slab without beam, however, is often too weak to control deflection properly compared to other typical slab-beam structures, for which the post-tension method is generally regarded as one of best solutions. The post-tension (PT) method can effectively control deflection without increase of slab thickness. Despite this good advantage, however, the application of PT method has been very limited due to cost increase, technical problems, and lack of experiences. Therefore, in order to reduce difficulties on applying full PT method under the current domestic circumstances and to enhance constructability of PT system, this research proposed the partial PT method with top jacking anchorage applied in a part of span as need. For the top jacking anchorage system, the efficiency of deflection control shall be considered in detail because it can vary widely depending on the location of anchorage that can be placed anywhere as need, and tensile stresses induced at back of the anchorage zone also shall be examined. Therefore, in this study, analysis were performed on the efficiency of deflection control depending on the location of anchorage and on tensile stresses or forces using finite element method and strut and tie model in the proposed top jacking anchorage system. The proposed jacking system were also applied to the floor slabs at a construction site to investigate its applicability and the analysis results of slab behavior were compared to the measured values obtained from the PT slab constructed by the partial PT method. The result of this study indicates that the partial PT method can be very efficiently applied with little cost increase to control deflection and tensile stresses in the region as a need basis where problem exists.

The assessment of dentoalveolar compensation in facial asymmetry individuals: integration of cone beam CT and laser scanned dental cast images (Cone beam CT 영상과 석고모형 레이저 스캔 영상의 결합을 이용한 안면비대칭자의 치성보상 평가)

  • Song, Hyo-Kyung;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik;Kim, Yong-Il
    • The korean journal of orthodontics
    • /
    • v.40 no.6
    • /
    • pp.373-382
    • /
    • 2010
  • Objective: The purpose of this study was to assess the dentoalveolar compensation in facial asymmetry individuals using an integration of a CBCT image and a laser scanned dental cast image. Methods: The subjects consisted of 30 adults with asymmetric mandibles and 20 adults with symmetric mandibles. The CBCT and laser scanned dental cast images were integrated with a registration technique. Canine and first molar position and angulation were assessed from reference coordinates. The differences between deviated and non-deviated sides were analyzed with the paired t-test. The differences shown according to menton deviation were also statistically analyzed using Pearson correlation analysis. Results: The experimental group showed deviated and non-deviated side differences (dev.-ndev.) in the position and angle of the canine and first molars. Menton deviation showed positive correlation with the deviation side (dev.-ndev.) for the maxillary and mandibular 1st molar angles, negative correlation with the deviation side for the vertical position of the maxillary 1st molars, transverse position of the mandibular canine, transverse position and vertical position of the mesio-lingual cusp of the mandibular 1st molars. Conclusions: The upper and lower canine and first molars of facial asymmetry individuals were compensated, so the transverse position, vertical position, and angle showed differences between the deviated/non-deviated sides.

Adjuvant Postoperative Radiation Therapy for Carcinoma of the Uterine Cervix (자궁경부암의 수술 후 방사선치료)

  • Lee Kyung-Ja;Moon Hye Seong;Kim Seung Cheol;Kim Chong Il;Ahn Jung Ja
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.199-206
    • /
    • 2003
  • Purpose: This study was undertaken to evaluate the efficacy of postoperative radiotherapy, and to investigate the prognostic factors for FIGO stages IB-IIB cervical cancer patients who were treated with simple hysterectomy, or who had high-risk factors following radical hysterectomy and pelvic lymph node dissection. Materials and Methods: Between March 1986 and December 1998, 58 patients, with FIGO stages IB-IIB cervical cancer were included in this study. The indications for postoperative radiation therapy were based on the pathological findings, including lymph node metastasis, positive surgical margin, parametrial extension, lymphovascular invasion, invasion of more than half the cervical stroma, uterine extension and the incidental finding of cervix cancer fellowing simple hysterectomy. All patients received external pelvic radiotherapy, and 5 patients, received an additional intracavitary radiation therapy. The radiation dose from the external beam to the whole pelvis was $40\~50$ Gy. Vagina cuff Irradiation was peformed, after completion of the external beam irradiation, at a low-dose rate of Cs-137, with the total dose of $4488\~4932$ chy (median: 4500 chy) at 5 mm depth from the vagina surface. The median follow-up period was 44 months ($15\~108$ months). Results: The 5-yr actuarial local control rate, distant free survival and disease-free survival rate were $98\%,\;95\%\;and\;94\%$, respectively. A univariate analysis of the clinical and pathological parameters revealed that the clinical stage (p=0.0145), status of vaginal resection margin (p=0.0002) and parametrial extension (p=0.0001) affected the disease-free survival. From a multivariate analysis, only a parametrial extension independently influenced the disease-free survival. Five patients ($9\%$) experienced Grade 2 late treatment-related complications, such as radiation proctitis (1 patient), cystitis (3 patients) and lymphedema of the leg (1 patient). No patient had grade 3 or 4 complications. Conclusion: Our results indicate that postoperative radiation therapy can achieve good local control and survival rates for patients with stages IB-IIB cervical cancer, treated with a simple hysterectomy, as well as for those treated with a radical hysterectomy, and with unfavorable pathological findings. The prognostic factor for disease-free survival was invasion of the parametrium. The prognosic factor identified in this study for treatment failure can be used as a selection criterion for the combined treatment of radiation and che motherapy.

The Results and Prognostic Factors of Postoperative Radiation Therapy in the Early Stages of Endometrial Cancer (초기 자궁내막암의 수술 후 방사선치료의 결과와 예후인자)

  • Lee, Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.149-159
    • /
    • 2008
  • Purpose: To evaluate the results and prognostic factors for postoperative adjuvant radiation therapy in patients at stages I and II of endometrial cancer. Materials and Methods: Between January 1991 and December 2006, 35 patients with FIGO stages I and II disease, who received adjuvant radiation therapy following surgery for endometrial cancer at Ewha Womans University Hospital, were enrolled in this study. A total of 17 patients received postoperative pelvic external beam radiation therapy; whereas, 12 patients received vaginal brachytherapy alone, and 6 patients received both pelvic radiation therapy and vaginal brachytherapy. Results: The median follow-up period for all patients was 54 months. The 5-yr overall survival and disease-free survival rates for all patients were 91.4% and 81.7%, respectively. The 5-yr overall survival rates for low-risk, intermediate-risk, and high-risk groups were 100%, 100% and 55.6%, respectively. In addition, the 5-yr disease-free survival rates were 100%, 70.0%, and 45.7%, respectively. Although no locoregional relapses were identified, distant metastases were observed in 5 patients (14%). The most common site of distant metastases was the lung, followed by bone, liver, adrenal gland, and peritoneum. A univariate analysis revealed a significant correlation between distant metastases and risk-group (p=0.018), pathology type (p=0.001), and grade (p=0.019). A multivariate analysis also revealed that distant metastases were correlated with pathology type (p=0.009). Papillary, serous and clear cell carcinoma cases demonstrated a poor patient survival rate compared to cases of endometrioid adenocarcinoma or adenosquamous carcinoma. The most common complication of pelvic external beam radiation therapy was enteritis (30%), followed by proctitis, leucopenia, and lymphedema. All these complications were of RTOG grades 1 and 2; no grades 3 and 4 were observed. Conclusion: For the low-risk and intermediate-risk groups (stages 1 and 2) endometrial cancer, pelvic control, and overall survival rate was free of severe toxicity when pelvic radiation therapy or vaginal brachytherapy was performed. In the high-risk group, pelvic control rate was excellent, but the survival rate was poor due to distant metastases, in spite of the pelvic radiation therapy. The combined modality of chemotherapy and radiation therapy is recommended for high-risk groups. For the intermediate-risk group, a prospective randomized study is required to compare the efficacy between whole pelvic radiation therapy and vaginal brachytherapy.

Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber (MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가)

  • Lee, Chang-Lae;Kim, Hee-Joung;Jeon, Seong-Su;Cho, Hyo-Min;Nam, So-Ra;Jung, Ji-Young;Lee, Young-Jin;Lee, Seung-Jae;Dong, Kyung-Rae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the MDCT, as well as of $CTDI_w$ according to temperature and pressure correction factors in the CT room. A comparative analysis was conducted based on the measured MDCT (GE light speed plus 4 slice, USA) data using head and body CT dosimetric phantom, and Model 2026C electrometer (RADICAL 2026C, USA) calibrated on March 21, 2007. As a result, the $CTDI_w$ value which reflected calibration factors, as well as correction factors of temperature and pressure, was found to be the range of $0.479{\sim}3.162mGy$ in effective radiation dose than the uncorrected values. Also, under the routine abdomen routine CT image acquisition conditions used in reference hospitals, patient effective dose was measured to indicate the difference of the maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the correction of temperature and pressure of the CT room are crucial in measuring and calculating patient effective dose. Thus, to measure patient radiation dose accurately, the detailed information should be made available regarding not only the temperature and pressure of the CT room, but also the humidity and recombination factor, characteristics of X-ray beam quality, exposure conditions, scan region, and so forth.

  • PDF

Ag Ion Substituted HAp Coatings on Ti-6Al-4V Substrate by IBAD and It's Bactericidal Effect (Ti 합금표면의 항균성 HAp Coating에 관한 연구)

  • Jung, Moon-Young;Kim, Taik-Nam;Kim, Yun-Jong;Yim, Hyuk-Jun;Kim, Jong-Ock;Lim, Dae-young;Kim, Sun-Ok
    • The Journal of Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.189-197
    • /
    • 1998
  • Hyeroxyapatite(HAp) which has good biocompatibility was made by Wet Chemical Process. The surface of Ti-6Al-4V, coated with HAp by lon Beam Assisted Deposition (IBAD), was treated with 5ppm, 10ppm, 20ppm, and 100ppm of $AgNO_3$ solution. In this Ag impregnation process, $Ca^{2+}$ of HAp was substituted with $Ag^+$ of $AgNO_3$. In this study, the antimicrobial effect and biocompatibility of Ti-6Al-4V alloy which was coated with Ag-HAp were examined. The antimicrobial test was carried out with two kinds of bacteria(P. Aeruginosa, S. Epidermidis), which are highly infectious in a transplanting operation of implant materials. As a result of the test, it was observed that Ti-6Al-4V alloy which was treated by 20ppm of $AgNO_3$ solution has good biocompatibility. In order to observe the antimicrobial mechanism of $Ag^+$, E. coli which is the most common bacterium was treated by Ag-HAp. Then cell morphology of E. coli was observed by the transmission electron microscope(TEM). The destruction of cell wall and cytoplasm of E. coil were observed. A black spot appeared in the cytoplasm was analyzed by energy dispersive analysis X-ray (EDAX) and it showed a small amount of $Ag^+$. Thus, it was proved that $Ag^+$ destroys bacteria effectively and Ti-6Al-4V alloy which was impregnate with Ag ion show antimicrobial effect on infection bacteria.

  • PDF

Postoperative Radiotherapy in Malignant Tumors of the Parotid Gland (이하선 악성종양의 수술 후 방사선 치료)

  • Chung Woong-Ki;Ahn Sung Ja;Nam Taek Ken;Chung Kyung-Ae;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.251-258
    • /
    • 1998
  • Purpose : This study was performed to analyze the factors affecting local control in malignant tumors of the parotid gland treated with surgery and postoperative radiation. Materials and methods : Twenty-six patients were treated for malignant tumors of the parotid gland from 1986 to 1995 at Department of Therapeutic Radiology, Chonnam University Hospital. Age of the patients ranged from 14 to 72 years (median : 55 years). Histologically 10 patients of mucoepidermoid carcinoma, 7 of squamous cell carcinoma, 4 of acinic cell carcinoma, 4 of adenoid cystic carcinoma and 1 of adenocarcinoma were treated. Total parotidectomy was performd in 15 of 26 patients, superficial in 7, subtotal in 4. Facial nerve was sacrificed in 5 patients. Postoperatively 4 patients had residual disease, 4 had positive resection margin. Radiation was delivered through an ipsilateral wedged pair of photon in 11 patients. High energy electron beam was mixed with photon in 15 patients. Electron beam dose ranged from 900 cGy to 3800 cGy (median 1700 cGy). Total radiation dose ranged from 5000 cGy to 7560 cGy (median : 6020 cGy). Minimum follow-up period was 2 years. Local control and survival rate were calculated using Kaplan-Meier method. Generalized Wilcoxon test and Cox proportional hazard model were used to test factors affecting local control. Results : Five (19$\%$) of 26 patients had local recurrence. Five year local control rate was 77$\%$. Overall five year survival rate was 70$\%$. Sex, age, tumor size, surgical involvement of cervical lymph node, involvement of resection margin, surgical invasion of nerve, and total dose were analyzed as suggested factors affecting local control rate. Among them patients with tumor size less than 4 cm (p=0.002) and negative resection margin (p=0.011) were associated with better local control rates in univariate analysis. Multivariate analysis showed only tumor size factor is associated with local control rate (p=0.022). Conclusion : This study suggested that tumor size is important in local control of malignant tumors of parotid gland.

  • PDF

The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation (몬테 카를로 전산모사를 통한 EPID의 외부적 선량 재구성과 내부 선량 계측과의 비교 및 분석)

  • Jung, Joo-Young;Yoon, Do-Kun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.253-258
    • /
    • 2013
  • The purpose of this study is to evaluate and analyze the relationship between the external radiation dose reconstruction which is transmitted from the patient who receives radiation treatment through electronic portal imaging device (EPID) and the internal dose derived from the Monte Carlo simulation. As a comparative analysis of the two cases, it is performed to provide a basic indicator for similar studies. The geometric information of the experiment and that of the radiation source were entered into Monte Carlo n-particle (MCNPX) which is the computer simulation tool and to derive the EPID images, a tally card in MCNPX was used for visualizing and the imaging of the dose information. We set to source to surface distance (SSD) 100 cm for internal measurement and EPID. And the water phantom was set to be 100 cm of the source to surface distance (SSD) for the internal measurement and EPID was set to 90 cm of SSD which is 10 cm below. The internal dose was collected from the water phantom by using mesh tally function in MCNPX, accumulated dose data was acquired by four-portal beam exposures. At the same time, after getting the dose which had been passed through water phantom, dose reconstruction was performed using back-projection method. In order to analyze about two cases, we compared the penetrated dose by calibration of itself with the absorbed one. We also evaluated the reconstructed dose using EPID and partially accumulated (overlapped) dose in water phantom by four-portal beam exposures. The sum dose data of two cases were calculated as each 3.4580 MeV/g (absorbed dose in water) and 3.4354 MeV/g (EPID reconstruction). The result of sum dose match from two cases shows good agreement with 0.6536% dose error.