• Title/Summary/Keyword: beam alignment

Search Result 257, Processing Time 0.023 seconds

Assembly of diameter 300 mm optical beam director (직경 300 mm 광집속장치의 광학정렬)

  • Yang, Ho-Soon;Lee, Yun-Woo;Kim, Jeong-Ju;Eum, Hae-Dong;Lee, Soo-Sang;Kim, Yeon-Soo;Kim, Hyun-Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.521-526
    • /
    • 2005
  • We assembled the optical beam director with diameter 300 mm. This consists of primary, secondary mirrors and 5 folding mirrors. Among them, the primary mirror is the most important component so that we measure any possible deformation on it at every step of assembly. Also, we developed the systematic alignment algorithm, which is essential because the number of mirrors is 7. The final wavefront error of the system is 1.9 wave rms (wave=633 nm) which is 7 times larger than we expected. The main source is the deformation of the 131ding mirrors. We expect that what we have learned from the assembly of this system would be helpful when we deal with a larger system in the future.

16-QAM OFDM-Based K-Band LoS MIMO Communication System with Alignment Mismatch Compensation

  • Kim, Bong-Su;Kim, Kwang-Seon;Kang, Min-Soo;Byun, Woo-Jin;Song, Myung-Sun;Park, Hyung Chul
    • ETRI Journal
    • /
    • v.39 no.4
    • /
    • pp.535-545
    • /
    • 2017
  • This paper presents a novel K-band (18 GHz) 16-quadrature amplitude modulation (16-QAM) orthogonal frequency-division multiplexing (OFDM)-based $2{\times}2$ line-of-sight multi-input multi-output communication system. The system can deliver 356 Mbps on a 56 MHz channel. Alignment mismatches, such as amplitude and/or phase mismatches, between the transmitter and receiver antennas were examined through hardware experiments. Hardware experimental results revealed that amplitude mismatch is related to antenna size, antenna beam width, and link distance. The proposed system employs an alignment mismatch compensation method. The open-loop architecture of the proposed compensation method is simple and enables facile construction of communication systems. In a digital modem, 16-QAM OFDM with a 512-point fast Fourier transform and (255, 239) Reed-Solomon forward error correction codecs is used. Experimental results show that a bit error rate of $10^{-5}$ is achieved at a signal-to-noise ratio of approximately 18.0 dB.

Band Alignment at CdS/wide-band-gap Cu(In,Ga)Se2 Hetero-junction by using PES/IPES

  • Kong, Sok-Hyun;Kima, Kyung-Hwan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.5
    • /
    • pp.229-232
    • /
    • 2005
  • Direct characterization of band alignment at chemical bath deposition $(CBD)-CdS/Cu_{0.93}(In_{1-x}Ga_x)Se_2$ has been carried out by photoemission spectroscopy (PES) and inverse photoemission spectroscopy (IPES). Ar ion beam etching at the condition of the low ion kinetic energy of 400 eV yields a removal of surface contamination as well as successful development of intrinsic feature of each layer and the interfaces. Especially interior regions of the wide gap CIGS layers with a band gap of $1.4\~1.6\;eV$ were successfully exposed. IPES spectra revealed that conduction band offset (CBO) at the interface region over the wide gap CIGS of x = 0.60 and 0.75 was negative, where the conduction band minimum of CdS was lower than that of CIGS. It was also observed that an energy spacing between conduction band minimum (CBM) of CdS layer and valance band maximum (VBM) of $Cu_{0.93}(In_{0.25}Ga_{0.75})Se_2$ layer at interface region was no wider than that of the interface over the $Cu_{0.93}(In_{0.60}Ga_{0.40})Se_2$ layer.

Electro-Optical Characteristics of TN Cell using UV Alignment Method on the a-C:H Thin Film (a-C:H 박막표면에 UV 배향법을 이용한 TN 셀의 전기광학특성)

  • Park, Chang-Joon;Hwang, Jeoung-Yeon;Kim, Jong-Hwan;Seo, Dae-Shik;Ahn, Han-Jin;Baik, Hong-Koo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1043-1046
    • /
    • 2003
  • We investigated the EO performances of the UV aligned twisted nematic liquid crystal display (TN-LCD) with the UV exposure on a-C:H thin film surface. LC alignment using UV exposure on the a-C:H thin film surface was achieved. Monodomain alignment of the UV aligned TN-LCD can be observed. An good EO characteristics of the UV aligned TN-LCD was observed with oblique ion beam exposure on the a-C:H thin film surface. Therefore, the EO property of the UV-aligned TN-LCD with UV exposure on the a-C:H thin film surface is almost the same as that of the rubbing-aligned TN-LCD on a polyimide (PI) surface.

  • PDF

Development of Proximity Exposure System with Vertical Structure for Plasama Display Panel (PDP용 수직형 구조의 근접 노광장치 개발)

  • Park, Jeong-Gyu;Jeong, Su-Hwa;Lee, Hang-Bu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2371-2380
    • /
    • 2000
  • In this paper, we developed the proximity exposure system with the vertical structure of glass and mask stage to minimize the mask's warp caused by the pull of gravity. This system, which canirradiate the ultra violet through 1440 H 850 $\textrm{mm}^2$ and 1330X 1015 $\textrm{mm}^2$ exposure area, has the followingcharacteristics. The glass stage can be inclined by 80 degrees at vertical structure to load substrate withsafety on it. When the glass stage is the vertical state, the gap control, alignment control and exposureof ultra violet are executed. So, it enhances the pattern uniformity by minimizing the mask's warp. Theglass stage can also control the gap between the mask and the substrate by the coarse and fine motioncontrol. The mask stage can adjust the posture of photomask to the position of substrate by imageprecessing method. The galss stage for the gap control and the mask stage for the alignment aredesigned independently for each function.

Compact Infrared/Visible Laser Transmitter Featuring an Extended Detectable Trajectory

  • Kim, Haeng-In;Lee, Hong-Shik;Lee, Sang-Shin
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.331-335
    • /
    • 2012
  • A miniaturized laser beam transmitter, in which a visible laser module at ${\lambda}$=650 nm is precisely stacked upon an infrared (IR) module at ${\lambda}$=905 nm, has been proposed and constructed to provide an IR collimated beam in conjunction with a collinear monitoring visible beam. In particular, the IR beam is selectively dispersed through a perforated sheet diffuser, so as to create a rapidly diverging close-range beam in addition to a highly defined long-range beam simultaneously. The complementary close-range beam plays a role in mitigating the blind region in the vicinity of the transmitter, which is inevitably missed by the main long-range beam, thereby uniformly extending the transmitter's effective trajectory that is sensed by a receiver. The proposed transmitter was designed through numerical simulations and then fabricated by incorporating a diffuser sheet, perforated with an aperture of 2 mm. For the manufactured transmitter, the IR long-range beam was observed to have divergences of ~2.3 and 1.6 mrad in the fast and slow axes, respectively, while the short-range beam yielded a divergence of ~24 mrad. The angular alignment between the long-range IR and visible beams was as accurate as ~0.5 mrad. According to an outdoor feasibility test involving a receiver, the combination of the IR long- and short-range beams was proven to achieve a nearly uniform trajectory over a distance ranging up to ~600 m, with an average detectable cross-section of ${\sim}60{\times}80cm^2$.

Development of automatic manufacturing system for optical collimators with high functionality (고기능 광콜리메이터의 자동 생산 시스템 개발)

  • 박래영;최두선;제태진;최기봉;강윤희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.119-122
    • /
    • 2002
  • Collimators were mostly produced by handwork and semi-automatic system in some companies. Under this situation, automatic manufacturing system for optical collimators is on the rise most essential technique in the development of optical communication components. In this study, automatic manufacturing system was designed and constructed to develop optical collimators with high functionality. Also optical collimators were manufactured using a developed automatic system. We have compared collimators made by automatic system and handwork fer performance test with a measured values of angle alignment, beam size and TIL. As a result, it brought a reduction of the tact time fur manufacturing and improvement of an efficiency of optical collimators, and then it was found that automatic system was indispensable for materialization of optical collimators with high functionality.

  • PDF

Fabrication and Packaging of Planar Waveguide Brags Grating (평판도파로 브래그격자 제조 및 접속)

  • 한준모;최준석;문형명;임기건;이형종;최두선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.141-144
    • /
    • 2002
  • Computer code was developed to design waveguide gratings based on coupled-mode equations and the transfer matrix formalism. The experimental set-up has been constructed for inscribing Bragg gratings in planar waveguides with a phase mask and uv laser beam, which enables alignment and packaging of grating devices as well as in-situ performance measurements. Bragg grating has been fabricated on silica planar waveguides with 0.75% Germanium concentration and its transmittance spectrum was measured to have 95% reflectance at the peak wavelength. Optical losses as the function of the misalignment were measured and their usage is described.

  • PDF

Design and Evaluation of Automatic Joining-Assembly System of Optical Collimators with High Functionality (고기능 광콜리메이터 접속조립 시스템 설계 및 성능평가)

  • 최두선;제태진;황경현;문재호;박래영;선화영
    • Transactions of Materials Processing
    • /
    • v.11 no.7
    • /
    • pp.589-595
    • /
    • 2002
  • Up to now, Collimators have been generally produced by handwork and only a few companies have produced by semi-automatic system. Under this situation, automatic system for assembly of optical collimator has risen as a most essential technique in the development of optical communication components. In this study, it was constructed to develop optical collimators with high functionality and We manufactured optical collimators with a GRIN rod lens using automatic system. Therefore, we worked a performance test through a comparison of collimators made by automatic system and handwork with angle alignment, beam size. Also we compared common product with auto-manufactured sample. As a result, it brought a reduction of the tact time and an improvement of an efficiency and a productivity of optical collimators. therefore it was found that automatic system was indispensable for materialization of optical collimators with high functionality.

Introduction of Hindfoot Coronal Alignment View (후족부 관상면 배열 영상에 대한 고안)

  • Moon, Il-Bong;Jeon, Ju-Seob;Yoon, Kang-Cheol;Choi, Nam-Kil;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.225-228
    • /
    • 2006
  • Purpose: Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hindfoot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hindfoot coronal alignment view. Material : 1) Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. 2) Both feet stood on a radiolucent platform with equal weight on both feet. 3) Both feet are located foot axis longitudinal perpendicular to the platform. 4) Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. 5) The x-ray beam is angled down approximately $15^{\circ} to $20^{\circ} Result : 1) This image described tibial axis and medial, lateral tuberosity of calcaneus. 2) Calcaneus do not rotated. 3) The view is showed by talotibial joint space. Conclusion: Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hindfoot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hindfoot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hindfoot and varus, valgus deformity of calcaneus.

  • PDF