• Title/Summary/Keyword: batch scan

Search Result 2, Processing Time 0.017 seconds

Analysis on Operation of Anti-Virus Systems with Real-Time Scan and Batch Scan (실시간스캔과 배치스캔을 갖춘 안티바이러스시스템의 운영 분석)

  • Yang, Won Seok;Kim, Tae-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.11
    • /
    • pp.861-869
    • /
    • 2013
  • We consider an information system where viruses arrive according to a Poisson process with rate ${\lambda}$. The information system has two types of anti-virus operation policies including 'real-time scan' and 'batch scan.' In the real-time scan policy, a virus is assumed to be scanned immediately after its arrival. Consequently, the real-time scan policy assumes infinite number of anti-viruses. We assume that the time for scanning and curing a virus follows a general distribution. In the batch scan policy, a system manager operates an anti-virus every deterministic time interval and scan and cure all the viruses remaining in the system simultaneously. In this paper we suggest a probability model for the operation of anti-virus software. We derive a condition under which the operating policy is achieved. Some numerical examples with various cost structure are given to illustrate the results.

Dosimetric Characteristics of Flexible Radiochromic Film Based on LiPCDA

  • Jung, Seongmoon;Cho, Jin Dong;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.179-184
    • /
    • 2021
  • This study aimed to determine the optimal thickness of the active layer and scan mode for a flexible radiochromic film (F-RCF) based on the active lithium salt of pentacosa-10,12-diynoic acid (LiPCDA). F-RCFs of 90, 120, 140, and 170-㎛ thickness were fabricated using LiPCDA. Several pieces of the F-RCFs were exposed to doses ranging from 0 to 3 Gy. Transmission and reflection modes were used to scan the irradiated F-RCFs. Their dose-response curves were obtained using a second-order polynomial equation. Their sensitivity was evaluated for both scanning modes, and the uniformity of the batch was also examined. For both the transmission and reflection modes, the sensitivity increased as the film thickness increased. For the reflection mode, the dose response increased dramatically under 1 Gy. The value of the net optical density varied rapidly as the thickness of the film increased. However, the dose-response curves showed a supralinear-curve relationship at doses greater than 2 Gy. The sensitivity of the reflection scan at doses greater than 2 Gy was higher than that of the reflection scan within 0-2 Gy. The sensitivity steadily decreased with increasing doses, and the sensitivity of the two modes was within 0.1 to 0.2 at 2 Gy and was saturated beyond that. For the transmission scan, the sensitivity was approximately 0.2 at 3 Gy. For the intra-batch test result, the maximum net optical density difference of the intra-batch was 5.5% at 2 Gy and 7.4% at 0.2 Gy in the transmission and reflection scans, respectively. In the low-dose range, film thickness of more than 120-㎛ was proper in the transmission mode. In contrast, the transmission mode showed a better result compared to the reflection mode. Therefore, the proper scan mode should be selected according to the dose range.