• 제목/요약/키워드: basic load

검색결과 1,235건 처리시간 0.032초

태안 시설원예단지의 온실 냉난방 부하 분석 (Analyses of Heating and Cooling load in Greenhouse of Protected Horticulture Complex in Taean)

  • 서원명;배용한;허해준;곽철순;이석건;이종원;윤용철
    • 한국농공학회논문집
    • /
    • 제51권6호
    • /
    • pp.45-52
    • /
    • 2009
  • This study was conducted in the process that the basic plan of the formation of the thermal energy complex in the Iwon reclaimed land of Taean was being made. Targeting for the large-sized greenhouse to be made in this area, it examined the cooling and heating load and the amount of ventilation, and also analyzed the economic efficiency of heating. The research results are as per the below: The minimum ambient temperature of this area was measured on January 7, 2001, which was $-18.7^{\circ}C$, and the maximum ambient temperature of this area was measured on July 24, 1994, which was $36.7^{\circ}C$. The maximum heating load was 39,011 MJ/h, but the date when the maximum heating load was not consistent with the date when the minimum temperature was measured. The maximum cooling load was 88,562MJ/h, It was approximately 2.3 times of the maximum heating load, which was measured at 14:00 hours on September 4, 2000. The maximum amount of ventilation heat was 138,639MJ/h. Assuming the rate of solar heat use as 10%, 20%, 50%, and 100%, the total sum of cost-benefit would be ₩-193,450,000, ₩-634,930,000, ₩-3,372,960,000, and ₩-9,850,420,000, respectively 20 years later. The break-even point of the geothermal heat pump would be about 4 years for 10% use, about 3 years for 20% or 50% use, and approximately 6 years for 100% use. It was found that 50% use would be most advantageous. In case two systems are combined, the break-even point will be 10 years, 8 years, and 11 years respectively.

부하지속곡선(LDC)을 이용한 영산강 · 탐진강수계 오염총량관리 목표수질 평가방법 적용 방안 (Application of the Load Duration Curve (LDC) to Evaluate the Rate of Achievement of Target Water Quality in the Youngsan · Tamjin River Watersheds)

  • 정은정;김홍태;김용석;신동석
    • 한국물환경학회지
    • /
    • 제32권4호
    • /
    • pp.349-356
    • /
    • 2016
  • Total Maximum Daily Loads (TMDLs) System has been used to improve water quality in the Youngsan·Tamjin river basin since 2004. The Basic Policy of TMDLs sets up the standard flow based on the average dry condition or mid-range flow during the last 10 years. However, Target Water Quality (TWQ) assessment on TMDLs has been used to evaluate water quality through eight-day intervals over 36 times a year. The results for allocation evaluation and target water quality evaluation were different from each other in the same unit watershed during the first period. In order to improve the evaluation method, researchers applied Load Duration Curve (LDC) to evaluate water quality in nine unit watersheds of the Youngsan·Tamjin river basin. The results showed that achievement rates of TWQ assessment with the current method and LDC were 67~100% and 78~100%, respectively. Approximately 11% of the achievement rates with use of LDC were higher than those with use of the current method. In conclusion, it is necessary to review the application of the LDC method in all Four Major River Watersheds.

태풍 시 플로팅도크 안벽 계류 로프 설계 (Design of quay mooring rope of Floating Dock against Typoon)

  • 김호경
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.569-574
    • /
    • 2020
  • 플로팅도크는 육상에서 건조된 선박을 해상으로 진수하기 위한 주요한 설비이다. 2000년대 초반 국내에서 육상에서 건조한 선박을 플로팅도크를 이용하여 진수할 수 있는 육상 건조 공법이 개발 적용됨에 따라 드라이도크에 대한 투자 없이 신조 사업에 참여할 수 있는 기회가 대폭 확대되었다. 본 논문에서는 이러한 육상 건조 공법을 활용하여 드라이도크를 보유하지 않은 중소업체에서 건조한 선박을 진수시킬 수 있는 플로팅도크의 안전한 계류를 위한 기본 계산을 수행하고 이를 기반으로 계류 시스템을 설계하였다. 본 논문은 적재 중량 4,000 Ton급 플로팅도크를 대상으로 하여, 플로팅도크가 설치되어 운영될 대불부두의 환경 요건 중 가장 심각한 상황인 태풍 상황을 고려하여 수행되었다. 설계 하중의 계산은 국제적으로 통용되는 기준을 따라 풍하중, 조류하중, 파에 의한 하중을 고려하였다. 대불 부두의 기존 계류 설비를 활용하여 플로팅 도크의 계류 로프 초기 배치를 수행한 후 주어진 하중에 따라 계류 로프별로 최소 파단 강도를 계산하였다. 계산 결과를 바탕으로 최소 파단 강도를 줄일 수 있도록 계류 배치를 일부 수정하였으며 최종 계류 라인의 규격을 선정하였다.

시계열 부하 곡선을 이용한 수체손상 평가 및 다변량 분석 -지석천 유역을 대상으로- (Evaluation of Impaired Waterbody and Multivariate Analysis Using Time Series Load Curve -in Jiseok Stream Watershed-)

  • 박진환;강태우;한성욱;백승권;강태구;유제철;김영석
    • 한국물환경학회지
    • /
    • 제33권6호
    • /
    • pp.650-660
    • /
    • 2017
  • In this study, pollutant emission characteristics by water damage period analyzed 11 items (water temperature, pH, DO, EC, BOD, COD, TOC, SS, T-N, T-P and flow) with load duration curve, time series load curve and factor analysis for three years (2014-2016). Load duration curve is applied to judge the level of impaired waterbody and estimate impaired level by pollutants such as BOD and T-P in this study depending on variation of stream flow. Water quality standard exceeded the flow of mid-range and low-range by flow condition evaluation using load duration curve. This watershed was influenced by point source more than non-point source. Cumulative excess rate of BOD and T-P kept water quality standard for all seasons (spring, summer, autumn and winter) except BOD 59% in spring. Water quality changes were influenced by pollutants of basic environmental treatment facilities and agricultural areas during spring and summer. Results of factor analysis were classified commonly first factor (BOD, COD, and TOC) and second factor (flow, water temperature and SS). Therefore, effects of artificial pollutants and maintenance water must be controlled seasonally and reduced relative to water damage caused by point pollution sources with effluent standard strengthened in the target watershed.

복합재료 교량 바닥판의 주행속도에 따른 동적응답 평가 (Estimation of Dynamic Response of Advanced Composite Material Decks for Bridges Application under Various Vehicle Driving Velocities)

  • 천경식;장석윤
    • Composites Research
    • /
    • 제16권6호
    • /
    • pp.23-32
    • /
    • 2003
  • 복합 신소재의 건설 분야 적용은 확대되고 있는 추세이고, 높은 비강도 비를 지닌 복합 신소재 교량 바닥 판의 개발은 국내외에서 활발히 진행되고 있다. 본 연구의 목적은 이동 하중을 받는 비등방성 복합재료 적층판의 동적 응답을 정식화하고, 유한요소법을 사용하여 적층에 따른 동적거동 특성을 분석하는 것이다. 수치 해석 모델에 대해서 이동하중의 속도를 증가시키면서 동적 확대 계수를 계산하였다. 또한 적층형식 및 순서, 섬유 보강 각도 등의 변화에 따른 동적 거동 특성을 분석하였다. 본 연구 프로그램의 타당성을 확보하기 위해 휨과 자유 진동 해석에 관한 기존 문헌 결과와 비교하여 검증하였다. 또한 이동 하중에 의한 동적 해석에 대해 모우드 중첩법과 Newmark 직접 적분법을 사용하였다. 이러한 이동 하중과 적층 수, 적층 순서 및 섬유 보강 각도에 따른 수치 해석 결과는 완전 복합 신소재 교량 바닥 판을 개발하는데 있어서 중요한 기초 자료로 제시될 수 있을 것이다.

주택에서의 단열성능 강화가 냉난방부하에 미치는 영향 (The Strengthening Effect of the Heating and Cooling Load on the Thermal Performance in the Housing Unit)

  • 이준기;김성훈;이갑택;이경희
    • 설비공학논문집
    • /
    • 제28권12호
    • /
    • pp.483-488
    • /
    • 2016
  • In this study, we chose the rural house as a standard model. In order to review the energy difference of cooling and heating loads, we changed the thermal transmittance standards. By using the thermal transmittance standard in 2011 as the Basic CASE, the thermal transmittance standard in 2013 as well as 2016, and the thermal transmittance standard of passive houses, we compared the results with regard to the cooling and heating energy load. Because of the heat loss, it can be confirmed that with an improved thermal performance of the building structure, the maximum increase of the cooling energy load was 36 kWh from June to September. Because of the heat loss, it was also confirmed that with the improved thermal performance of a building structure, the maximum decrease of the heating energy load is 1,498 kWh from November to April. Even though the heat loss of the building structure could decrease the cooling energy load by improving thermal transmittance standards in Korea, the energy saving performance is worse than the situation of heating energy load in heating period. Compared with CASE 1 and CASE 2, as well as CASE 1 and CASE 3, we CASE 3 was found to have the best energy saving rate when compared to the other cases : CASE 3 increased by 1,452 kWh and CASE 2 by 588 kWh, because the window thermal transmittance standard of 2016 was added.

동작중 작용부하 분석을 위한 간접적 부하규명 (Indirect Load Identification for the Operational Load Analysis)

  • 조문선
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권6호
    • /
    • pp.501-507
    • /
    • 2003
  • 환자의 재활을 돕는 보조기 및 의지와 같은 의료기기의 기본 요건 중의 하나는 충분한 강도를 가지도록 설계해야 하는 것이다. 강도설계를 위해서는 먼저 기구에 작용하는 부하를 파악하여야 하는데, 인체에 직접 착용하거나, 인체의 운동을 돕도록 고안된 의료기구의 특성상 정하중 보다는 동하중 형태의 부하를 받는 경우가 많으며, 때때로 충격하중을 받는 경우도 있다. 이같은 형태의 부하를 직접적으로 파악하기 위해서는 구조물에 계측용 센서를 직접 설치하여야 하나, 이럴 경우 센서의 설치로 인한 구조 변경으로 인해 계의 고유 특성을 유지할 수 없는 경우가 흔히 발생하다. 따라서, 이와 같은 경우에는 작용 부하를 간접적으로 즉, 진동 등의 출력으로부터 역으로 구해내는 수 밖에는 없다. 본 논문에서는 이와 같은 동하중 형태의 부하 즉, 작동부하를 구하는 데 있어서 기존 방법인 전달률 방법의 문제점 및 한계점을 살펴보고, 다수개의 기준점을 사용하여 다입력 환경하에서도 적용이 가능한 주성분 분석을 이용한 새로운 방법을 제시하였으며, 실험을 통해 이의 타당성을 검증하였다.

부하 형태에 따른 전력패턴 분석 (Analysis of Power Pattern According to Load Types)

  • 황미용;조승준;이순형;최용성
    • 한국전기전자재료학회논문지
    • /
    • 제36권4호
    • /
    • pp.369-375
    • /
    • 2023
  • In this paper, we compared and analyzed the power load patterns of dormitory buildings and office buildings to use them as basic data (demand analysis and capacity design) for the design and operation of microgrids for multi-use facilities, and the following conclusions were got. During the daytime on regular weekdays, the power consumption load pattern of office buildings was relatively large at 264.0~332.3 kWh, and during the evening hours, the power consumption load pattern of dormitory buildings was relatively large at 233.0~258.3 kWh. In the case of vacation, during the daytime on weekdays, the power consumption load pattern of office buildings was relatively large at 279.1~407.4 kWh, and in the evening, the power consumption load pattern of dormitory buildings was relatively high at 280.1~394.1 kWh. During the daytime on regular weekends, the power consumption of dormitory-type buildings was relatively high at 133.5~201.6 kWh, and it was found that the power consumption of dormitory-type buildings appeared relatively high at 187.5~252.1 kWh. During a vacation in the daytime on weekends, the power consumption of dormitory-type buildings was found to be 186.5 kWh~ and 218.6 kWh. The increase in power consumption during a vacation (December-February) compared to normal (April-June) was thought to be due to an increase in electricity demand, and the reason for the higher power consumption in dormitory buildings during the vacation was due to reduced working hours in office buildings.

Experimental Study on Impact Loads Acting on Free-falling Modified Wigley

  • Hong, Sa-Young;Kim, Young-Shik;Kyoung, Jo-Hyun;Hong, Seok-Won;Kim, Yong-Hwan
    • International Journal of Ocean System Engineering
    • /
    • 제2권3호
    • /
    • pp.151-159
    • /
    • 2012
  • The characteristics of an impact load and pressure were experimentally investigated. Drop tests were carried out using a modified Wigley with CB = 0.56. The vertical force, pressures, and vertical accelerations were measured. A 6-component load cell was used to measure the forces, piezo-electric sensors were used to capture the impact pressure, and strain-gauge type accelerometers were used to measure the vertical accelerations. A 50-kHz sampling rate was applied to capture the peak values. The repeatability of the measured data was confirmed and the basic characteristics of the impact load and pressure such as the linearity to the falling height were observed for all of the measurements. A simple formula was derived to extract the physical impact load from the measured force based on a simple mass-sensor-mass diagram, which was validated by comparing impact forces with existing data using the mathematical model of Faltinsen and Chezhian (2005). The effects of the elasticity of the model and change in acceleration during the water entry were investigated. It is interesting to observe that the impact loads occurred and reached peak values at the same time duration after water entry for all drop heights.

운전 중인 전력용 변압기(154kV)의 부하용량과 경년이 진동에 미치는 영향 (Effect on Vibration According to the Load Capability and Elapsed Year of Power Transformer(154kV) in Operation)

  • 김영달;김성중
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.172-177
    • /
    • 2009
  • Most of the causes of the failures of power transformers in operations are mechanical defects due to vibration. To identify these causes, the vibration phenomenon was measured from the power transformers in operation in the substations under the Daejeon power transmission district office of KEPCO. The measurement was performed in a 6${times}$4 structure on one side of the transformer. The vibration of the measured points was presented in 2D and 3D, and analyzed. The results according to the period in use of the transformer and the load applied to the transformer were analyzed. These results will be used as basic data to establish the vibration standard for the power transformer, In addition, with a load capability and vibration phenomenon correlation and regression analysis to identify by way of function was reached. And the vibration phenomenon pass a years with changes and to analyze correlation, was estimated to bring in the function. And then through the analysis of power transformers to set standards based on vibration data was used to.