• 제목/요약/키워드: basic load

검색결과 1,236건 처리시간 0.031초

외부 하중이 어깨관절의 능동적 재위치 검사 결과에 미치는 영향: 3차원 동작 분석 시스템을 이용한 예비연구 (Effect of External Load on Shoulder Joint Active Relocation Using 3D Motion Capture System: A Pilot Study)

  • 황지선;황선홍
    • 한국전문물리치료학회지
    • /
    • 제25권2호
    • /
    • pp.71-77
    • /
    • 2018
  • Background: There are insufficient objective or quantitative evidence for the better intervention to improve proprioception particularly for the application of external load. There are conflicting opinions whether the external load is effective for proprioception improvement or not. Objects: The purpose of this study was to investigate effects of external load on proprioception of shoulder joint quantitatively using 3D motion capture system. Methods: Nine healthy adults joined for this study. They were asked to perform scapular plane abduction motion with attaching reflective markers on the trunk and upper limb. The 3D positions of finger marker, while they performed the same task with and without external load, were recorded and analyzed. Results: All participants showed decreased variable errors in the vertical direction when the external load was applied (p<.02). Even though other directions (y, z) and absolute errors increased, they did not have statistical significances. Conclusion: Based on this study results, the external load application would be effective for shoulder joint position sense improvement.

Heating and Cooling Load of Building according to Atrium Layout

  • Jeong, Nam-Young;Lee, Ji-Young;Chae, Young Tae
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.29-36
    • /
    • 2016
  • Purpose: The purpose of this study is to present basic data which would be applied on the early stage of the architectural design. And that determines the introduction of the atrium by comparing and analysing the environmental performance of atrium building. Method: The building forms are classified into low storied building, middle storied building and high storied building. This study compares and analyses energy performance of the standard building without atrium and the atrium building which has one-side, two-side, three-side, four-side, and linear atrium by measuring of annual heating and cooling load with EnergyPlus. Result: As a result of the analysis of the relative annual heating and cooling load by building type, it is shown that the fluctuation of cooling load in low storied building is large because heat storage in atrium affects building, and the fluctuation of heating load in high storied building is large owing to the effect of external wall area of atrium which makes heat loss. Especially, it indicated the largest annual heating and cooling load in four-side atrium of low storied building, and in one-side atrium of high storied building.

수출형 기본 훈련기에 대한 기체구조물 내구성 입증 (Airframe Durability Certification for Export Basic Trainer)

  • 박태규;박정규;문창오
    • 항공우주시스템공학회지
    • /
    • 제9권2호
    • /
    • pp.19-24
    • /
    • 2015
  • Export basic trainer was designed to add armed configuration required by customer. Design configuration of main wing was changed to satisfy changed internal load caused by armed configuration. It was verified that design changed main wing airframe of export basic trainer satisfy the requirement through the structural detail analysis, structural ground test and flight test. This paper presents the durability test procensure and test result for the main wing of export basic trainer.

Low Temperature Test of HWR Cryomodule

  • Kim, Heetae;Kim, Youngkwon;Lee, Min Ki;Park, Gunn-Tae;Kim, Wookang
    • Applied Science and Convergence Technology
    • /
    • 제25권3호
    • /
    • pp.47-50
    • /
    • 2016
  • Low temperature test for half-wave resonator (HWR) cryomodule is performed at the superfluid helium temperature of 2 K. The effective temperature is defined for non-uniform temperature distribution. Helium leak detection techniques are introduced for cryogenic system. Experimental set up is shown to make the low temperature test for the HWR cryomodule. The cooldown procedure of the HWR cryomodule is shown from room temperature to 2 K. The cryomodules is precooled with liquid nitrogen and then liquid helium is supplied to the helium reservoirs and cavities. The pressure of cavity and chamber are monitored as a function of time. The vacuum pressure of the cryomodule is not increased at 2 K, which shows leak-tight in the superfluid helium environment. Static heat load is also measured for the cryomodule at 2.5 K.

KSTAR TOKAMAK의 열차폐막 설계 (The Design of Thermal Shield for KSTAR TOKAMAK)

  • 김동락;노영미;허남일;조승연;육종설;안귀천;도철진;권면;이경수;윤병주
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.45-47
    • /
    • 2001
  • The function of the thermal shield(TS) is to eliminate the thermal radiation from the room temperature side to the coil temperature(4.5K) region so as to reduce the thermal load on the He refrigerator. The TS is composed of multilayer insulation(MLI) which is coated very thin aluminum on the insulating material, cryopanel which is cooled by cold gaseous He, and supports which stand the cryopanel and MLI on the room temperature part. The thermal shield for the TF coils and PF coils has been located between the coils and vacuum vessel. The thermal shielding cryopanel is cooled under 80 K by a forced flow of helium gas using cooling pipes on the cryopanel.

  • PDF

자기보상형 유정압저어널베어링의 기본특성 (Basic Characteristics of a Self-Compensated Hydrostatic Journal Bearing)

  • 박천홍;이영준;홍성욱;이후상
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.227-230
    • /
    • 2004
  • A self-compensated water-hydrostatic bearing has advantages in bearing stiffness. In this paper, the mechanism is applied to hydrostatic journal bearing for achieving the high bearing stiffness. The finite element method is applied to analyze the load characteristics of the self-compensated journal bearing. From the analyzed results, it is confirmed that though the self-compensated journal bearing has higher load capacity and stiffness than conventional fixed capillary journal bearing, the merit is decreased in the case of high eccentricity, that is, a spindle system with self-compensated journal bearing must be designed to have the load capacity large enough. For improving the practicality, a rectangular type capillary is introduced and discussed. Theoretically analyzed results show that it has more advantages than the conventional annular type capillary in the practical usage. The experimental verification on the analysis method is performed, and the experimental results show good agreement with theoretical results.

  • PDF

밀리미터파 대역 제2고조파 고효율 생성을 위한 부하 임피던스의 최적화 방법 (A Method of Load Impedance Optimization for High Efficiency Millimeter-wave Range 2nd Harmonic Generation)

  • 최영규
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1566-1571
    • /
    • 2011
  • The objective of this paper is to present a quantitative analysis leading to the assessment of optimum terminating impedances in the design of active frequency multipliers. A brief analysis of the basic principal of the GaAs FET frequency multiplier is presented. The analysis is outlined in bias optimization and drive power determination. Utilizing the equivalent circuit model of GaAs FET, we have simulated the optimized load impedance for the maximum output of the active frequency multipliers. The C-class and reverse C-class frequency doublers have been fabricated and the load impedances have been measured. The experimental results are in good agreement with the estimated results in the simulation with the accuracy of 90%.

부하패턴을 이용한 전력시장 정보의 불완비성 추정에 관한 연구 (The Estimation of Incomplete Information in Electricity Markets by Using Load Pattern Changes)

  • 신재홍;이광호
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.848-853
    • /
    • 2007
  • This paper presents a methodology of estimating incomplete information in electricity markets for analyzing the gaming behavior of Generating Companies (GENCOs). Each GENCO needs to model its opponents' unknown information of strategic biddings and cost functions. In electricity markets with complete information, each GENCO knows its rivals' payoff functions and tries to maximize its own profit at Nash equilibriurnl Nli) by acknowledging the rivals' cost function. On the other hand, in the incomplete information markets, each GENCO lacks information about its rivals. Load patterns can change continuously due to many factors such as weather, price, contingency, etc. In this paper, we propose the method of the estimation of the opponents' cost function using market price, transaction quantities. and customer load patterns. A numerical example with two GENCOs is illustrated to show the basic idea and effectiveness of the proposed methodology.

Hot-Spot 응력을 이용한 하중전달형 십자형 필렛 용접재의 피로강도 평가 (Fatigue Strength of the Load-Carrying Cruciform Fillet Welded Joints Using the Hot-Spot Stress)

  • 박종민;최원식;권순홍;노병욱
    • 한국기계가공학회지
    • /
    • 제6권1호
    • /
    • pp.20-26
    • /
    • 2007
  • In this study, fatigue strength of load-carrying cruciform fillet welded joints were evaluated using a new method proposed by Yamada, for geometric or structural stress in welded joint, that is, one-millimeter stress below the surface in the direction corresponding to the expected crack path. Validity of the method is verified by analyzing fatigue test results for load-carrying cruciform welded specimens has different size of weld toe radius, leg length and plate thickness reported in literature. Structural stress concentration factor for 1mm below the surface was calculated by finite element analysis for each specimen respectively. When compared to the basic fatigue resistance curve offered by BS7608, the one-millimeter stress method shows conservative evaluation for load-carrying cruciform fillet welded joints.

  • PDF