• Title/Summary/Keyword: base-pressure recover

Search Result 4, Processing Time 0.019 seconds

Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer (국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선)

  • Park, Jun-Hyung;Im, Ki-Seop;Lee, Hong-Jin;Jeong, Kyung-Il;Lee, Byung-Chul;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.147-151
    • /
    • 2009
  • Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

  • PDF

Effects of Hypovolemic Hypotension on Cardiopulmonary Functions and Acid-Base Balance (출혈성 쇼크가 심폐기능 및 산.염기평형에 미치는 영향)

  • Sou, Won-Young;Lee, Sung-Haing
    • Journal of Chest Surgery
    • /
    • v.6 no.2
    • /
    • pp.131-142
    • /
    • 1973
  • Studies of cardiopulmonary function and acid-base balance were performed on 29 dogs during control period, during oligemic hypotension and following return of blood to the animals. Intravenous morphine and local anesthesia were used. Fifteen of the 29 animals survived the complete experiment. The 14 animals that failed to survive the experimental period died between 15 to 90 minutes after the onset of bleeding. The results were as follows. 1. The heart rate increased after the onset of bleeding and failed to return to control level following reinfusion. Stroke volume decreased markedly after bleeding and failed to recover after return of blood from the reservoir. Cardiac output also decreased during oligemic hypotension and was maintained at this level after re-infusion. Total peripheral resistance decreased significantly immediately after bleeding, however it increased soon over the pre-bleeding level. Central venous pressure decreased after the onset of bleeding and remained at lower level for the rest of the experimental period. Arterial blood pressure, clown to 40-45 mmHg by acute hemorrhage, was elevated near to control level. Left ventricular work decreased tremendously during oligemic hypotension and failed to return to control level with the re-infusion of blood. Hematocrit value showed no significant decrease after bleeding and increased after re-infusion. Hemoglobin decreased after the onset of bleeding and recovered to control value after re-infusion. 2. The respiratory rate fell rapidly after bleeding from 124 to 29 and remained at this lower level for the remainder of the experiment. The tidal volume increased after bleeding and was maintained at this level for the remainder of the experiment. The respiratory minute volume showed no significant changes throughout the experimental period. Oxygen consumption fell lightly in all animals during oligemic hypotension and returned to normal levels following re-infusion. Arterial oxygen content and arterial oxygen saturation decreased following bleeding and the values returned to normal levels after the return of blood from the reservoir The arterio-venous oxygen difference increased after the onset of bleeding. It failed to return to normal values following re-infusion. Arterial $Pco_2$ decreased in all animals after the beginning of the bleeding. Partial pressure of $Co_2$ continued to fall until re-infusion, after which the values returned toward normal. Animals became acidotic. The pH fell to lower level following bleeding. Lactic acid and lactate: pyruvate ratio also increased during same period. Arterial pH and lactic acid failed to return to control value and lactate: pyruvate ratio increased more after re-infusion. Sodium bicarbonate decreased after bleeding and returned to control value following re-infusion.

  • PDF

Performance Evaluation to Develop an Engineering Scale Cathode Processor by Multiphase Numerical Analysis (다상유동 전산모사를 통한 공학 규모의 cathode processor의 성능평가)

  • Yoo, Bung Uk;Park, Sung Bin;Kwon, Sang Woon;Kim, Jeong Guck;Lee, Han Soo;Kim, In Tae;Lee, Jong Hyeon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.1
    • /
    • pp.7-17
    • /
    • 2014
  • Molten salt electrorefining process achieves uranium deposits at cathode using an electrochemical processing of spent nuclear fuel. In order to recover pure uranium from cathode deposit containing about 30wt% salt, the adhered salt should be removed by cathode process (CP). The CP has been regarded as one of the bottle-neck of the pyroprocess as the large amount of uranium is treated in this step and the operation parameters are crucial to determine the final purity of the product. Currently, related research activities are mainly based on experiments consequently it is hard to observe processing variables such as temperature, pressure and salt gas behavior during the operation of the cathode process. Hence, in this study operation procedure of cathode process is numerically described by using appropriate mathematical model. The key parameters of this research are the amount of evaporation at the distillation part, diffusion coefficient of gas phase salt in cathode processor and phase change rate at condensation part. Each of these conditions were composed by Hertz-Langmuir equation, Chapman-Enskog theory, and interphase mass flow application in ANSYS-CFX. And physical properties of salt were taken from the data base in HSC Chemistry. In this study, calculation results on the salt gas behavior and optimal operating condition are discussed. The numerical analysis results could be used to closely understand the physical phenomenon during CP and for further scale up to commercial level.