• Title/Summary/Keyword: base-metal

Search Result 1,589, Processing Time 0.027 seconds

High Fatigue Life and Tensile Strength Characteristics of Low Activation Ferritic Steel(JLE-1) by TIG Welding (TIG용접한 저방사화 페라이트강(JLF-1)의 고온강도 및 피로수명특성)

  • Yoon, H.K.;Lee, S.P.;Kim, S.W.;Park, W.J.;Kohyama, A.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.181-186
    • /
    • 2001
  • JLF-1 steel (Fe-9Cr-2W-V-Ta), low activation ferritic steel, is one of the promising candidate materials fer fusion reactor applications. High temperature fatigue life and tensile strength of JLF-1 steel and its TIG welded joints were investigated at the room temperature and $400^{\circ}C$. The strength of base metal (JLF-1) is in between those of weld metal and the HAZ. When the test temperature was increased from room temperature to $400^{\circ}C$, both strength and ductility decreased for base metal, weld metal and the HAZ. The longitudinal specimens of base metal showed similar strength and ductility compared with those of the transverse specimens at room temperature and $400^{\circ}C$. Little anisotropy was observed in the JLF-1 steel base metal in terms of rolling direction. Fatigue limit of weld metal which was obtained from cross-weld specimen is 495MPa. Thus, the weld metal showed the higher fatigue limit than those of base metal at both room temperature and $400^{\circ}C$. Little anisotropy of fatigue properties was observed for JLF-1 base metal in terms of rolling direction. When the test temperature was increased from room temperature to $400^{\circ}C$, the fatigue limit of both base metal and weld metal decreased substantially.

  • PDF

A comparative study on the accuracies of resin denture bases and metal denture bases

  • Park Hwee-Woong;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.250-259
    • /
    • 2001
  • Since the late 1930s, acrylic resins have been the materials of choice for the fabrication of complete denture bases. It has excellent esthetic properties, adequate strength, low water sorption, and low solubility. But acrylic resin has disadvantage of processing shrinkage that reduces denture retention and accuracy of denture occlusion. Metals also have been used in denture base material. Metals used in denture bases display excellent strength and dimensional stability. The major disadvantages associated with metal denture bases include increased cost, difficulty in fabrication, compromised esthetic qualities, and inability to re-base. The purpose of this study is to compare the artificial tooth movements of complete dentures with resin bases and metal bases after curing, deflasking, polishing immersion in water for 1 week and 4 weeks. Twenty-four maxillary complete resin denture bases with artificial teeth were fabricated. Twelve of them were resin based and other twelve of them were metal based. Fine crosses were marked on the incisal edges of right central incisors and distobuccal cusps of be second molars. Measurements were done for the changes of distances of reference points at the time of wax denture, after deflasking after decasting after polishing after immersion in water for 1 week and 4 weeks Meaurements were done to the accuracy of 0.001mm with a measuring microscope. The results were as follows : 1. Metal base showed significantly less tooth movement than resin base after curing and decasting (p<0.01). 2. Metal base showed significantly less tooth movement than resin base after polishing (p<0.01). 3. After immersion in water for 1 week and 4 weeks, metal base showed less movement than resin base. Difference was significant for anterior-posterior distances (p<0.01), but not significant for molar-to-molar distance (p>0.01). 4. 1 week and 4 weeks of immersion failed to compensate the initial processing shrinkage of metal and resin bases (p>0.01).

  • PDF

A Study on sorting out base metal using eddy current sensor (와전류 센서를 이용한 금속 모재 선별에 관한 연구)

  • Lee G.S.;Kim T.O.;Kim H.Y.;Ahn J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1788-1792
    • /
    • 2005
  • Eddy current sensor is representative instrument measuring gap to base metal and sensing trouble in base metal. The existing eddy current sensor works as measuring variance of sensor coil's inductance. But, sensor coil have phenomenon that not only inductance but also real resistance varies in real action. Conductivity and Permeability are main variable in sensor coil's varying impedance(inductance, real resistance). By searching relationship between conductivity-permeability and sensor coil's impedance, eddy current sensor gain advantage of elevation of accuracy, removal of alignment to each base metal, and continuous sensing to varying base metal.

  • PDF

Strength Characteristics of Reduced Activation Ferritic Steel for Fusion Blanket by TIG Welding (핵융합로 블랭킷용 저방사화 철강재료 TIG 용접부의 강도특성)

  • ;;;A. Kohyama
    • Journal of Welding and Joining
    • /
    • v.21 no.1
    • /
    • pp.87-92
    • /
    • 2003
  • JLF-1 steel (Fe-9Cr-2W-V-Ta), reduced activation ferritic steel, is one of the promising candidate materials for fusion reactor applications. Tensile properties of JLF-1 base metal and its TIG weldments has been investigated at the room temperature, $400^{\circ}C$ and $600^{\circ}C$. The tensile strength of base metal (JLF-1) showed the level between those of weld metal and the Heat Affected Zone (HAZ). When the test temperature was increased from room temperature to high temperature ($400^{\circ}C$ and $600^{\circ}C$), both strength and ductility decreased or base metal, weld metal and the HAZ. The longitudinal specimens of base metal represented similar strength and ductility at room temperature and high temperature, compared to those of transverse specimens. Little anisotropy for the rolling direction was observed in the base metal of JLF-1 steel.

Fatigue Crack Propagation Behavior in Butt Weldment of SA106 Gr.C Main Steam Pipe Steel

  • Kim, Eung-Seon;Jang, Chan-Su;Kim, In-Sup
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.92-97
    • /
    • 1996
  • The fatigue crack propagation behavior in SA106 Gr.C main steam pipe weld joint was investigated in air environment. Crack growth rate tests were conducted on base metal and weld metal at load ratio of 0.1 and 0.3 and at frequency of 10Hz. The fatigue crack growth rates of the base metal and the weld metal were above the ASME reference line and the fatigue crack propagation rate of the weld metal was higher than those of the base metal. Fatigue crack growth rate increased with increasing the load ratio and the effect of the load ratio was more significant in the weld metal. The post weld heat treatment increased the fatigue crack growth rates of the base metal by reducing compressive residual stress and decreased those of the weld metal by reducing weld defects.

  • PDF

A Study on Development of Insert Metal for Liquid Phase Diffusion Bonding of Fe Base Heat Resistance Alloy (Fe 기내열합금의 액상확상접합용 삽입금속의 개발에 관한 연구)

  • 강정윤;김인배;이상래
    • Journal of Welding and Joining
    • /
    • v.13 no.3
    • /
    • pp.147-156
    • /
    • 1995
  • The change of microstructure in the bonded interlayer and tensile properties of joints were studied for liquid phase diffusion bonding using STS-310 and Incoloy-825 as base metal and base metal+B alloy as insert inetal. Main experimental results obtained in this study are as follows. 1) The optimum amount of B addition into the insert metal was found to be about 4mass%. 2) When isothermal solidification was completed, the microstructure in the bonded interlayer was the same with that of the base metal because of the grain boundary migration in the bonded interlayer. 3) All of the tensile specimen fractured at base metal and joints bonded at optimum condition exhibited tensile properties in excess of base metal requirements. 4) It was determined that fine car-borides and bordes such as M$_{23}$(C,B)$_{6}$, Cr$_{2}$B, and CrB in STS-310S and TiB in Incoloy-825 exist at the grain boundary around bonded interlayer. These precipitates almost disappeared after homogenizing treatment at 1373K for 86.4ks.s.

  • PDF

The Comparative Study on the Castability to the Frequency of Reuse with Precious Metal Alloys and Base Metal Alloys widely used in the Production of Partial Denture (국부의치(局部義齒) 제작(製作)에 사용(使用)되는 귀금속합금(貴金屬合金)과 비귀금속합금(非貴金屬合金)의 재(再) 사용(使用) 횟수에 따른 주조성(鑄造性) 비교(比較) 연구(硏究))

  • Chung, Kyung-Pung;Choi, Un-Jae
    • Journal of Technologic Dentistry
    • /
    • v.17 no.1
    • /
    • pp.10-25
    • /
    • 1995
  • The purpose of this study is to get the difference of the castability in the production of partial denture between Precious Metal Alloys and Base Metal Alloys accompanied with the frequency of reuse. As materials for an experiment, we selected Baker-444 and Soo-444 and Soo-sung as Precious Metal Alloys, New Crown and Chrome Cobalt as Base Metal Alloys. And we tired to case all of them seven times. The experimental results were as follows : 1) In the probability of segments, Baker-444 showed 100$\pm$0.00%, Soo-sung 97.24$\pm$1.58%, New Crown 95.63$\pm$4.28%, and Chrome Cobalt 91.03$\pm$7.76%. Consequently, Precious Metal Alloys were decidely superior to Base Metal Alloys in the castability. 2) In the view of the acheived result, burn-out temperature and smocking time had greatly affected the castability. 3) After casting, Precious Metal Alloys were much less than Base Metal Alloys in the quantity of consumption. It made much difference from the the compiled stastics(p<0.01)

  • PDF

The effects of 3.5% NaCl solution on the corrosion fatigue crack propagation characteristics of SS41 steel (SS41강의 부식피로 균열 전파특성에 미치는 3.5% NaCl수용액의 영향)

  • 오세욱;김재철;최영수
    • Journal of Ocean Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.111-119
    • /
    • 1987
  • The corrosion fatigue crack propagation characteristics of SS41 steel in 3.5% NaCl solution have been evaluated for loading frequencies of 1Hz and 0.2Hz. A sine wave loading profile was used for fatigue testing. Each test was carried out at a constant stress ratio, R(0.1). The main results are summarized as follows; 1. Fatigue crack propagation rate was higher in 3.5% NaCl solution than in air, higher in the base metal than in the weld metal, and higher at f =0.2Hz than at f =1Hz. 2. The crack closure level of the base metal was not influenced by cyclic frequencies, but that of the weld metal was much influenced. 3. When the crack closure effect was eliminated in the evaluation of crack propagation characteristics by using $\Delta K_{eff}$, the envirommental influence was distinctly observed. At the base metal, crack propagation rate was enhanced by the hydrogen embrittlement, and the weld metal was reduced by the crac closure. 4. There was clearly observed hydrogen embrittlement and severely corroded aspect at fracture surface of lower frequency than that of higher frequency, and at that of base metal than that of the weld metal.

  • PDF

The Effect of Base Metal Grain Boundary on Isothermal Solidification Phenomena during TLP Bonding of Ni Base Superalloys (액상확산접합한 Ni기 초내열합금의 등온응고거동에 미치는 모재결정입계의 영향)

  • 김대업
    • Journal of Welding and Joining
    • /
    • v.19 no.3
    • /
    • pp.325-333
    • /
    • 2001
  • The effect of base metal grain size on isothermal solidification behavior of Ni-base superalloy, CMSX-2 during transient liquid phase (TLP) bonding was investigated employing MBF-80 insert metal. TLP-bonding of single crystal. coarse-grained and fine-grained CMSX-2 was carried out at 1373∼1548k for various holding time in vacuum. The eutectic width diminished linearly with the square root of holding time during isothermal solidification process for single crystal, coarse-grained and fine-grained base metals. The completion time for isothermal solidification decreased in the order ; single crystal, coarse-grained and fine-grained base metals. The difference of isothermal solidification rates produced when bonding the different base metals could be explained quantitatively by the effect of base metal grain boundaries on the apparent average diffusion coefficient of boron in CMSX-2.

  • PDF

Characteristics of Liquid Phase Diffusion Bonded Joints Using Newly Developed Ni-3Cr-4Si-3B Insert Metal of Heat Resistant Alloy (신개발 Ni-3Cr-4Si-3B 삽입금속으로 액상확산접합한 내열주강 접합부의 특성)

    • Journal of Welding and Joining
    • /
    • v.18 no.6
    • /
    • pp.62-67
    • /
    • 2000
  • Metallurgical characteristics of bonded region and high temperature mechanical properties of heat resistant alloy, Fe-35Ni-26Cr during liquid phase diffusion bonding were investigated employing AM17 insert metal. The insert metal for bonding, AM17 was newly developed Ni-base metal using interpolation method. Bonding of specimens were carried out at 1,403~1,463K for 600s in vacuum. The microconstituents in the bonded interlayer disappeared in the bonding temperature over 1,423K. The microstructures, alloying elements and hardness distribution in the base metal. The tensile strength and elongation of the joints at elevated temperatures were the same level as one of the base metal in the bonding temperature over 1,423K. The creep rupture strength and rupture lives of joints were almost identical to those of base metal.

  • PDF