• Title/Summary/Keyword: base-isolated

Search Result 551, Processing Time 0.023 seconds

Dynamic Analysis of Base-Isolated Rectangular Liquid Storage Structures (기초격리된 직사각형 유체 저장 구조물의 동적 해석)

  • Park, Jang-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.109-116
    • /
    • 2004
  • The dynamic behavior of the rectangular liquid storage structure is known to be greatly influenced by fluid-structure interaction. By mounting the liquid storage structure on the properly designed base isolators, dynamic response of the superstructure can be reduced. However, base isolators inevitably incur large displacement of the structure to the ground ·ind may give adverse effects on the sloshing height. This paper presents the analysis method for fluid-structure-isolator interaction in base-isolated rectangular liquid storage structures. In the method, the irrotational motion of invicid and incompressible ideal fluid is expressed by analytic solutions and the superstructure and isolators are properly modeled by finite element and bilinear model. Free surface sloshing motion, hydrodynamic pressure acting on the wall and structural response are obtained by the presented method.

Seismic mitigation of an existing building by connecting to a base-isolated building with visco-elastic dampers

  • Yang, Zhidong;Lam, Eddie S.S.
    • Structural Engineering and Mechanics
    • /
    • v.53 no.1
    • /
    • pp.57-71
    • /
    • 2015
  • This study investigates the feasibility of retrofitting an existing building by connecting the existing building to a new building using connecting dampers. The new building is base-isolated and viscoelastic dampers are assigned as connecting dampers. Scaled models are tested under three different earthquake records using a shaking table. The existing building and the new building are 9 and 8 stories respectively. The existing building model shows more than 3% increase in damping ratio. The maximum dynamic responses and the root mean square responses of the existing building model to earthquakes are substantially reduced by at least 20% and 59% respectively. Further, numerical models are developed by conducting time-history analysis to predict the performance of the proposed seismic mitigation system. The predictions agree well with the test results. Numerical simulations are carried out to optimize the properties of connecting dampers and base isolators. It is demonstrated that more than 50% of the peak responses can be reduced by properly adjusting the properties of connecting dampers and base isolators.

Smart passive control of buildings with higher redundancy and robustness using base-isolation and inter-connection

  • Murase, Mitsuru;Tsuji, Masaaki;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • v.4 no.6
    • /
    • pp.649-670
    • /
    • 2013
  • It is known that a base-isolated building exhibits a large response to a long-duration, long-period wave and an inter-connected system without base-isolation shows a large response to a pulse-type wave. To compensate for each deficiency, a new hybrid passive control system is investigated in which a base-isolated building is connected to another building (free wall) with oil dampers. It is demonstrated that the present hybrid passive control system is effective both for pulse-type ground motions and long-duration and long-period ground motions and has high redundancy and robustness for a broad range of disturbances.

Biosynthesis of Nucleic Acid in Chloroplast Isolated from Chlorella Cells. I. (Chlorella제포에서 분리한 엽록체의 핵산합성 1)

  • 이종삼;석영애
    • Korean Journal of Microbiology
    • /
    • v.21 no.4
    • /
    • pp.197-206
    • /
    • 1983
  • For the purpose of investigating the effect of nalidixic acid on the nucleic acid synthesis in chloroplast isolated from Chlorella ellipsoidea, cells were cultured in the media treated with nalidixic acid(20ppm) for 5 days. Aliquots cells were taken out at the inoculation and at intervals during the culture and growth rate of Chlorella cells measured. After extraction of nucleic acids in chloroplast isolated from these cells, their contents were analyzed by the base composition and the effect of nalidixic acid on the nucleic acid synthesis interpreted to compare with those of the control. 1. It was showed that the inhibitory concentration affected by nalidixic acid on the growth of Chlorella cells were 20ppm. 2. Because nalidixic acid had depressed the DNA replication in isolated chloroplast as well as whole cell system, these contents were markedly decreased in comparison with those of the control. 3. In the isolated chloroplast as well as in the whole cell system, nalidixic acid was decreased contents of base in the RNA by preventing RNA transcription.

  • PDF

Effect of the incoherent earthquake motion on responses of seismically isolated nuclear power plant structure

  • Ahmed, Kaiser;Kim, Dookie;Lee, Sang H.
    • Earthquakes and Structures
    • /
    • v.14 no.1
    • /
    • pp.33-44
    • /
    • 2018
  • Base-isolated nuclear power plant (BI-NPP) structures are founded on expanded basemat as a flexible floating nuclear island, are still lacking the recommendation of the consideration of incoherent motion effect. The effect of incoherent earthquake motion on the seismic response of BI-NPP structure has been investigated herein. The incoherency of the ground motions is applied by using an isotropic frequency-dependent spatial correlation function to perform the conditional simulation of the reference design spectrum compatible ground motion in time domain. Time history analysis of two structural models with 486 and 5 equivalent lead plug rubber bearing (LRB) base-isolators have been done under uniform excitation and multiple point excitation. two different cases have been considered: 1) Incoherent motion generated for soft soil and 2) Incoherent motion generated for hard rock soil. The results show that the incoherent motions reduce acceleration and the lateral displacement responses and the reduction is noticeable at soft soil site and higher frequencies.

Development of wind tunnel test model of mid-rise base-isolated building

  • Ohkuma, Takeshi;Yasui, Hachinori;Marukawa, Hisao
    • Wind and Structures
    • /
    • v.7 no.3
    • /
    • pp.203-214
    • /
    • 2004
  • This paper describes a method for developing a multi-degree-of freedom aero-elasto-plastic model of a base-isolated mid-rise building. The horizontal stiffness of isolators is modeled by several tension springs and the vertical support is performed by air pressure from a compressor. A lead damper and a steel damper are modeled by a U-shaped lead line and an aluminum line. With this model, the frequency ratio of torsional vibration to sway vibration, and plastic displacements of isolation materials can be changed easily when needed. The results of isolation material tests and free vibration tests show that this model provides the object performance. The peak displacement factors are about 4.5 regardless of wind speed in wind tunnel tests, but their gust response factor decreases with increment of wind speed.

Vibration control of hysteretic base-isolated structures: an LMI approach

  • Pozo, Francesc;Pujol, Gisela;Acho, Leonardo
    • Smart Structures and Systems
    • /
    • v.17 no.2
    • /
    • pp.195-208
    • /
    • 2016
  • Seismic isolation systems are essentially designed to preserve structural safety, prevent occupants injury and properties damage. An active saturated LMI-based control design is proposed to attenuate seismic disturbances in base-isolated structures under saturation actuators. Using a mathematical model of an eight-storied building structure, an active control algorithm is designed. Performance evaluation of the controller is carried out in a simplified model version of a benchmark building system, which is recognized as a state-of-the-art model for numerical experiments of structures under seismic perturbations. Experimental results show that the proposed algorithm is robust with respect to model and seismic perturbations. Finally, the performance indices show that the proposed controller behaves satisfactorily and with a reasonable control effort.

Dynamic Reanalysis of Base-Isolated Systems Using a Perturbation Technique (섭동법에 의한 면진구조계의 동적 재해석)

  • Kim, Hee-duck
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.2
    • /
    • pp.167-175
    • /
    • 2001
  • In this study, a general perturbation method is presented to reanalysis dynamic response of base-isolated systems. The perturbation is expanded to general order and which provide the formulation of perturbed solutions. in which eigensolutions of non-modified system are treated as unperturbed solutions. The accuracy of present method is tested using a 2-DOF system with isolator, where the stiffness and damping coefficients of isolator are changed, respectively, The reanalyzed eigensolutions and response using perturbed solutions are successfully approached to exact ones after just first perturbation. Supposing the practical criterion as ${\pm}5%$ error, the modification range of -50%~30% from original system can be allowed for the first order perturbation. Using higher order solutions, the applicable range will be wide.

  • PDF

Base-isolated building with high-damping spring system subjected to near fault earthquakes

  • Tornello, Miguel Eduardo;Sarrazin, Mauricio
    • Earthquakes and Structures
    • /
    • v.3 no.3_4
    • /
    • pp.315-340
    • /
    • 2012
  • There are many types of seismic isolation devices that are being used today for structural control of earthquake response in buildings. The most commonly used are sliding bearings and elastomeric bearings, the latter with or without lead core. An alternative solution is the use of steel springs combined with viscoelastic fluid dampers, which is the case discussed in this paper. An analytical study of a three-story building supported on helical steel springs and viscoelastic fluid dampers, GERB Control System (GCS), subjected to near-fault earthquakes is presented. Several earthquakes records have been obtained by the acceleration network installed in the isolated building and in its non-isolated twin since they were finished. These experimental results are analysed and discussed. The aim is to show that the spring-based system can be an alternative for base isolation of small building located near active faults.

Seismic Response Characteristics of Submerged Systems with Large Hydrodynamic Effect in Base-isolated Structure (지진절연 건물내 유체동적효과가 큰 수중계의 지진응답특성)

  • Shin, Tae-Myung;Kim, Kwang-Joon
    • Journal of KSNVE
    • /
    • v.7 no.4
    • /
    • pp.655-661
    • /
    • 1997
  • Base-isolation of a primary structure generally decrete the seismic response of its own and the secondary structure. It may cause an adverse effect on the seismic response of secondary system when the system is submerged and subject to a considerable hydrodynamic effect. In this paper, it is shown how, and how much, the base isolation of the primary structure can affect the secondary system response in extreme cases through dynamic analysis of a simplified coupled model for a submerged secondary system and a base-isolated primary structure. As an aseismatic design approach to reduce the response of the submerged system, optimization of the fluid gap, which controls the hydrodynamic mass effect, is performed. As an alternative approach in case where the control of fluid gap is unrealistic, application of base isolation to the submerged system is suggested. Effectiveness of various combinations of the primary base and secondary base isolations are compared.

  • PDF