• Title/Summary/Keyword: base-isolated

Search Result 551, Processing Time 0.027 seconds

Investigating Dynamic Characteristics on Support Base for IPB Duct System and Reducing Vibration for IPB Duct (IPB 덕트의 진동저감과 기초에 대한 동특성 고찰)

  • Yang, Kyeong-Hyeon;Cho, Chul-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.495-500
    • /
    • 2001
  • Because of resonance between natural frequency of the second floor base for IPB(Isolated Phase Bus) duct supports in a power plant and operation frequency of the turbine, there was high amplitude vibration on IPB duct. To reduce vibration of IPB duct, Firstly it was set a FEM model to seek the mode shape for the concrete structure. Secondly, it was carried out dynamic analysis for the FEM model. Lastly, because the natural frequency of the concrete structure could not be changed, it was changed supports position for the IPB duct near to beams. It resulted in reducing vibration of IPB duct.

  • PDF

Study on Seismic Responses for Base Isolated Structure Using Linear 2 DOF System and Its Application for NPP (선형 2자유도계를 이용한 면진구조물의 지진응답 연구 및 원자력발전소 적용)

  • Yoo, Bong;Lee, Jae-Han
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.225-232
    • /
    • 1997
  • A study of effects of design parameters on the seismic responses of base isolated structure is performed to reduce the seismic responses using a linear tw0-degree of freedom system and a lumped-mass model of a nuclear power p;ant(NPP). From the simplified 2 DOF system the optimal isolation frequency being less than 1/10th of the fundamental frequency of superstructure is obtained, and the isolator damping minimizing the peak acceleration depends on superstructure frequency. From the time history analyses for lumped mass model of NPP the optimal damping is calculated as 40% in containment building and 65% in reactor internal structure. Similar results are obtained in 2 DOF system

  • PDF

Seismic Risk Evaluation of Isolated Emergency Diesel Generator System (면진된 비상디젤발전기의 지진위험도 평가)

  • Kim, Min-Kyu;Ohtori, Yasuki;Choun, Young-Sun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.217-222
    • /
    • 2007
  • An Emergency Diesel Generator (EDG) is one of the safety related equipments of a Nuclear Power Plant. The seismic capacity of an EDG in nuclear power plants influences the seismic safety of the plants significantly. A recent study showed that the increase of the seismic capacity of the EDG could reduce the core damage frequency (CDF) remarkably. It is known that the major failure mode of the EDG is a concrete coning failure due to a pulling out of the anchor bolts. The use of base isolators instead of anchor bolts can increase the seismic capacity of the EDG without any major problems. This study introduces a seismic risk analysis method and presents sample results about the seismically isolated and conventional EDG system.

  • PDF

Reduction of seismic pounding effects of base-isolated RC highway bridges using MR damper

  • Sheikh, M.N.;Xiong, J.;Li, W.H.
    • Structural Engineering and Mechanics
    • /
    • v.41 no.6
    • /
    • pp.791-803
    • /
    • 2012
  • Significant structural damages due to pounding between adjacent superstructures of multi-span reinforced concrete (RC) highway bridges have been observed in past earthquakes. Different methods have been proposed in the literature to mitigate the adverse seismic pounding effects. This paper presents an analytical investigation on the use of magnetorheological (MR) dampers in reducing seismic pounding effects of base-isolated multi-span RC highway bridges. It has been observed that MR damper can effectively reduce the seismic pounding effect. Three control strategies (passive off, passive on, and bang bang control) of MR damper have been investigated. Although all the control strategies are found to be effective, bang bang control has been observed to be the most effective.

Analysis of soft deformation limitation of base-isolated structures

  • Jinwei Jiang;Baoyang Yang
    • Earthquakes and Structures
    • /
    • v.26 no.1
    • /
    • pp.1-15
    • /
    • 2024
  • Isolation technology has been proven effective in reducing the seismic response of superstructures, where most of the deformation is concentrated in the isolation layer. However, in cases of earthquakes with intensities surpassing the fortification level of the area, or severe near-fault earthquakes, the isolation layer may experience excessive deformation, resulting in damage to the isolation bearings or collisions with the retaining wall or surrounding buildings. In this study, a finite element model using ABAQUS is established and compared with experimental test results to deeply investigate the influence of limit devices on the isolation layer and its response to the superstructure. The findings reveal that a larger limiter stiffness and a smaller reserved gap can achieve a more effective limiting effect. Nevertheless, a smaller reserved gap and a larger limiter stiffness may result in increased response of the superstructure. Therefore, rational selection of the reserved gap and limiter stiffness is crucial to reduce the acceleration response.

A Study on Testing of 1/4-scale and Full-size Seismic Isolation Bearings (축소모델과 실모델 면진베어링의 성능실험에 관한 연구)

  • 정민기;정지만;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.194-202
    • /
    • 1996
  • An approach to increase the seismic resistance of large structures is to reduce the seismic forces, to which structures are subjected by base isolation systems. The anti-seismic performance of base-isolated beatings has been verified experimentally by shaking table tests. However, it may be difficult to perform the tests for the full-scale beatings of base-isolated structures. Therefore, the test program was designed to evaluate the reliability and properties of the beatings under a range of loading conditions including axial stress, loading frequency and direction, and temperature. The effects of scale were also evaluated by comparing the results of the 1/4-scale beatings with those from the full-scale bearings, and the ultimate behavior of both types of bearings with evaluated through a series of roll-out tests. This report draws comparisons among the different tests and bearings to determine the importance of various factors including load history, axial stress, and frequency. Comparisons between the 1/4-scale bearings were difficult because of the scaling effects in manufacturing and thermal radiation, but qualitative results from the 1/4-scale bearings can certainly be extrapolated the full-scale bearings.

  • PDF

Seismic responses of asymmetric steel structures isolated with the TCFP subjected to mathematical near-fault pulse models

  • Tajammolian, H.;Khoshnoudian, F.;Bokaeian, V.
    • Smart Structures and Systems
    • /
    • v.18 no.5
    • /
    • pp.931-953
    • /
    • 2016
  • In this paper, the effects of mass eccentricity of superstructure as well as stiffness eccentricity of isolators on the amplification of seismic responses of base-isolated structures are investigated by using mathematical near-fault pulse models. Superstructures with 3, 6 and 9 stories and aspect ratios equal to 1, 2 and 3 are mounted on a reasonable variety of Triple Concave Friction Pendulum (TCFP) bearings considering different period and damping ratio. Three-dimensional linear superstructure mounted on nonlinear isolators are subjected to simplified pulses including fling step and forward directivity while various pulse period ($T_p$) and Peak Ground Velocity (PGV) amounts as two crucial parameters of these pulses are scrutinized. Maximum isolator displacement and base shear as well as peak superstructure acceleration and drift are selected as the main engineering demand parameters. The results indicate that the torsional intensification of different demand parameters caused by superstructure mass eccentricity is more significant than isolator stiffness eccentricity. The torsion due to mass eccentricity has intensified the base shear of asymmetric 6-story model 2.55 times comparing to symmetric one. In similar circumstances, the isolator displacement and roof acceleration are increased 49 and 116 percent respectively in the presence of mass eccentricity. Furthermore, it is demonstrated that torsional effects of mass eccentricity can force the drift to reach the allowable limit of ASCE 7 standard in the presence of forward directivity pulses.

Cloning and Sequencing of Nonstructural Protein (NSP4) Gene of Bovine Rotavirus Isolated in Korea (국내분리 소 로타바이러스 NSP4 유전자의 크로닝 및 염기서열 분석)

  • Back, Myoung-Soon;Kim, Won-Yong;Kang, Shien-Young
    • The Journal of Korean Society of Virology
    • /
    • v.30 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • The nonstructural protein NSP4, encoded by gene 10 of rotavirus, has been shown to playa role in viral assembly and known to be an enterotoxin, causing diarrhea in mouse pups. NSP4 gene was cloned from CBNU-2 (virulent bovine rotavirus/diarrheic fecal sample) and CBNU-1 (cell-culture adapted bovine rotavirus/isolated from CBNU-2 and 75 times passaged on MA104 cells), respectively, by reverse transcriptase-polymerase chain reaction (RT-PCR) and sequenced and compared. The sequence data indicated that the NSP4 genes of bovine rotavirus (BRV) were 751 bases in length and encoded one open reading frame of 175 amino acids beginning at base 42 and terminating at base 569. Differences in nucleotide sequence between CBNU-2 and CBNU-1 were observed at 6 positions (base 274, 296, 391, 394, 396 and 579). NSP4 gene of BRV exhibited a high degree of nucleotide (90% and 94%) and amino acid sequence (91% and 97%) homology with those of SA11 and UK but a low degree of nucleotide (77% and 79%) and amino acids sequence (81% and 85%) homology with those of Wa and OSU.

  • PDF

Random Response Analysis of Base Isolated Nuclear Container System (기초분리된 원전 격납구조물의 무작위 반응해석)

  • 홍원기;전제성;유광호
    • Computational Structural Engineering
    • /
    • v.7 no.4
    • /
    • pp.145-150
    • /
    • 1994
  • Seismic isolation in ordinary buildings has been successively adapted to provide flexibility for the reduction of base shear forces and its concept is accepting wide agreement in lengthening the natural, period to lessen the spectral acceleration transmitted into the structure. However, one of difficulties in implementing the innovative concept to nuclear structures is due to more severe requirements in both understanding and predicting the characteristics of isolators and the behavior of cushioned structures, Stochastic analysis has been carried out to investigate the response of base isolated nuclear containers to the random earthquake ground motion.

  • PDF

Effectiveness of non-linear fluid viscous dampers in seismically isolated buildings

  • Guler, Elif;Alhan, Cenk
    • Earthquakes and Structures
    • /
    • v.17 no.2
    • /
    • pp.191-204
    • /
    • 2019
  • Near-field earthquake records including long-period high-amplitude velocity pulses can cause large isolation system displacements leading to buckling or rupture of isolators. In such cases, providing supplemental damping in the isolation system has been proposed as a solution. However, it is known that linear viscous dampers can reduce base displacements in case of near-field earthquakes but at the potential expense of increased superstructure response in case of far-field earthquakes. But can non-linear dampers with different levels of non-linearity offer a superior seismic performance? In order to answer this question, the effectiveness of non-linear viscous dampers in reducing isolator displacements and its effects on the superstructure response are investigated. A comparison with linear viscous dampers via time history analysis is done using a base-isolated benchmark building model under historical near-field and far-field earthquake records for a wide range of different levels of non-linearity and supplemental damping. The results show that the non-linearity level and the amount of supplemental damping play important roles in reducing base displacements effectively. Although use of non-linear supplemental dampers may cause superstructure response amplification in case of far-field earthquakes, this negative effect may be avoided or even reduced by using appropriate combinations of non-linearity level and supplemental damping.