• 제목/요약/키워드: base school

검색결과 3,009건 처리시간 0.027초

광중합형 이장재와 금속의치상 간의 결합력에 관한 연구 (A Study on the Tensile Strength between Light-cured Relining Resin and Metal Denture Base)

  • 박인채;이준규;정재헌
    • 구강회복응용과학지
    • /
    • 제16권3호
    • /
    • pp.211-220
    • /
    • 2000
  • The use of autopolymerizing-cured resin and light-cured resin for direct relining of complete and partial dentures has been popular. This investigation compared the adhesion of autopolymerizing-cured reline resin(Tokuso Rebase, Mild Rebaron) or light-cured reline resin(Mild Rebaron LC, Lighton-U) to metal base or resin base. Cylindrical samples were made from metal($Biosil^{(R)}$) or heat-cured resin(QC-20) and were prepared to produce a flat bonding surface. Cylindrical metal samples were roughened by scratch or by scratch and sandblast and were treated with primer(MR Bond) after scratch and sandblast. And then, liners were prossesed to the cylindrical metal or resin samples according to the manufacturer's recommendations so as to bond metal base or resin base. The specimens were tested in pure tension by using an Instron Univesal testing machine for the four direct reline resins. The results were as follows ; 1. In comparison with tensile bond strength of material relined on resin base or metal base, the case of resin base produced significantly higher tensile bond strength than the case of metal base. 2. Metal surface pretreatment or primer improved the tensile bond strength between the reline resin and the metal($Biosil^{(R)}$) base. 3. The tensile bond strength of Mild Rebaron LC relined on resin base or metal base were similar to those of the other reline resins.

  • PDF

광중합형 이장재와 금속의치상 간의 결합력에 관한 연구 (A Study on the Tensile Strength between Light-cured Relining Resin and Metal Denture Base)

  • 박인채;이준규;정재헌
    • 구강회복응용과학지
    • /
    • 제16권2호
    • /
    • pp.161-170
    • /
    • 2000
  • The use of autopolymerizing-cured resin and light-cured resin for direct relining of complete and partial dentures has been popular. This investigation compared the adhesion of autopolymerizing-cured reline resin(Tokuso Rebase, Mild Rebaron) or light-cured reline resin(Mild Rebaron LC, Lighton-U) to metal base or resin base. Cylindrical samples were made from metal($Biosil^{(R)}$) or heat-cured resin(QC-20) and were prepared to produce a flat bonding surface. Cylindrical metal samples were roughened by scratch or by scratch and sandblast and were treated with primer(MR Bond) after scratch and sandblast. And then, liners were prossesed to the cylindrical metal or resin samples according to the manufacturer's recomendations so as to bond metal base or resin base. The specimens were tested in pure tension by using an Instron Univasal testing machine for the four direct reline resins. The results were as follows ; 1. In comparison with tensile bond strength of material relined on resin base or metal base, the case of resin base produced significantly higher tensile bond strengths than the case of metal base. 2. Metal surface pretreatment or primer improved the tensile bond strength between the reline resin and the metal($Biosil^{(R)}$) base. 3. The tensile bond strengths of Mild Rebaron LC relined on resin base or metal base were similar to those of the other reline resins.

  • PDF

Modified complex mode superposition design response spectrum method and parameters optimization for linear seismic base-isolation structures

  • Huang, Dong-Mei;Ren, Wei-Xin;Mao, Yun
    • Earthquakes and Structures
    • /
    • 제4권4호
    • /
    • pp.341-363
    • /
    • 2013
  • Earthquake response calculation, parametric analysis and seismic parameter optimization of base-isolated structures are some critical issues for seismic design of base-isolated structures. To calculate the earthquake responses for such non-symmetric and non-classical damping linear systems and to implement the earthquake resistant design codes, a modified complex mode superposition design response spectrum method is put forward. Furthermore, to do parameter optimization for base-isolation structures, a graphical approach is proposed by analyzing the relationship between the base shear ratio of a seismic base-isolation floor to non-seismic base-isolation one and frequency ratio-damping ratio, as well as the relationship between the seismic base-isolation floor displacement and frequency ratio-damping ratio. In addition, the influences of mode number and site classification on the seismic base-isolation structure and corresponding optimum parameters are investigated. It is demonstrated that the modified complex mode superposition design response spectrum method is more precise and more convenient to engineering applications for utilizing the damping reduction factors and the design response spectrum, and the proposed graphical approach for parameter optimization of seismic base-isolation structures is compendious and feasible.

Navier-Stokes Computations and Experiment of The Supersonic Flows Over a Cylindrical Afterbody with Base Bleed

  • 김희동;권오식
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2000년도 제14회 학술강연논문집
    • /
    • pp.14-14
    • /
    • 2000
  • One of the most important aerodynamic performance characteristics for projectiles is the total drag which can be typically divided into three components, pressure drag (excluding the base), viscous skin friction drag, and base drag. In a range of supersonic flight speeds the base drag is a major contributor to the total drag and can be as much as 50%∼70% of the total drag, depending on the afterbody configuration of projectiles. It is of especial importance to minimize this part of. the drag.

  • PDF

Constraint Algorithm in Double-Base Number System for High Speed A/D Converters

  • Nguyen, Minh Son;Kim, Man-Ho;Kim, Jong-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.430-435
    • /
    • 2008
  • In the paper, an algorithm called a Constraint algorithm is proposed to solve the fan-in problem occurred in ADC encoding circuits. The Flash ADC architecture uses a double-base number system (DBNS). The DBNS has known to represent the multi-dimensional logarithmic number system (MDLNS) used for implementing the multiplier accumulator architecture of FIR filter in digital signal processing (DSP) applications. The authors use the DBNS with the base 2 and 3 to represent binary output of ADC. A symmetric map is analyzed first, and then asymmetric map is followed to provide addition read DBNS to DSP circuitry. The simulation results are shown for the Double-Base Integer Encoder (DBIE) of the 6-bit ADC to demonstrate an effectiveness of the Constraint algorithm, using $0.18{\mu}\;m$ CMOS technology. The DBIE’s processing speed of the ADC is fast compared to the FAT tree encoder circuit by 0.95 GHz.

프레임이 적용된 스탬프 베이스의 동특성 분석 (Analysis of dynamic characteristic applying frame on stamped base in 2.5 inch hard disk drive)

  • 임건엽;박노철;박경수;김석환
    • 정보저장시스템학회논문집
    • /
    • 제9권2호
    • /
    • pp.51-55
    • /
    • 2013
  • HDD has been easily exposed to the external shock and vibration because HDD has to apply to mobile devices. Therefore, the stiffness of base has been the important factors for the design of HDD. To improve the stiffness of base, the frame was applied to the base. First, the finite element model of the base was constructed. Then, the FE model was verified by modal analysis. Drop test was performed to confirming the shock simulation model. The dynamic characteristic of original base which is verified is compared with the base which is applied the frame through modal analysis and shock analysis.

Physical properties and color stability of injection-molded thermoplastic denture base resins

  • Song, So-Yeon;Kim, Kyoung-Soo;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.32-40
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare mechanical and physical properties of injection-molded thermoplastic denture base resins. MATERIALS AND METHODS. In this study, six commercially available products (VA; Valplast, LC; Lucitone, ST; Smiltone, ES; Estheshot-Bright, AC; Acrytone, WE; Weldenz) were selected from four types of thermoplastic denture base materials (Polyamide, Polyester, Acrylic resin and Polypropylene). The flexural properties and shore D hardness have been investigated and water sorption and solubility, and color stability have evaluated. RESULTS. For the flexural modulus value, ES showed the highest value and WE showed significantly lower value than all other groups (P<.05). Most of experimental groups showed weak color stability beyond the clinically acceptable range. CONCLUSION. Within the limits of this study, thermoplastic denture base resin did not show sufficient modulus to function as a denture base. In addition, all resins showed discoloration with clinical significance, and especially polyamides showed the lowest color stability.

Experimental and numerical investigation on exposed RCFST column-base Joint

  • Ben, Mou;Xingchen, Yan;Qiyun, Qiao;Wanqiu, Zhou
    • Steel and Composite Structures
    • /
    • 제45권5호
    • /
    • pp.749-766
    • /
    • 2022
  • This paper investigates the seismic performance of exposed RCFST column-base joints, in which the high-strength steel bars (USD 685) are set through the column and reinforced concrete foundation without any base plate and anchor bolts. Three specimens with different axial force ratios (n = 0, 0.25, and 0.5) were tested under cyclic loadings. Finite element analysis (FEA) models were validated in the basic indexes and failure mode. The hysteresis behavior of the exposed RCFST column-base joints was studied by the parametrical analysis including six parameters: width of column (D), width-thickness ratio (D/t), axial force ratio (n), shear-span ratio (L/D), steel tube strength (fy) and concrete strength (fc). The bending moment of the exposed RCFST column-base joint increased with D, fy and fc. But the D/t and L/D play a little effect on the bending capacity of the new column-base joint. Finally, the calculation formula is proposed to assess the bending moment capacities, and the accuracy and stability of the formula are verified.

Analysis and design of demountable circular CFST column-base connections

  • Li, Dongxu;Wang, Jia;Uy, Brian;Aslani, Farhad;Patel, Vipul
    • Steel and Composite Structures
    • /
    • 제28권5호
    • /
    • pp.559-571
    • /
    • 2018
  • In current engineering practice, circular concrete-filled steel tubular (CFST) columns have been used as effective structural components due to their significant structural and economic benefits. To apply these structural components into steel-concrete composite moment resisting frames, increasing number of research into the column-base connections of circular CFST columns have been found. However, most of the previous research focused on the strength, rigidity and seismic resisting performance of the circular CFST column-base connections. The present paper attempts to investigate the demountability of bolted circular CFST column-base connections using the finite element method. The developed finite element models take into account the effects of material and geometric nonlinearities; the accuracy of proposed models is validated through comparison against independent experimental results. The mechanical performance of CFST column-base connections with both permanent and demountable design details are compared with the developed finite element models. Parametric studies are further carried out to examine the effects of design parameters on the behaviour of demountable circular CFST column-base connections. Moreover, the initial stiffness and moment capacity of such demountable connections are compared with the existing codes of practice. The comparison results indicate that an improved prediction method of the initial stiffness for these connections should be developed.

Nostril Base Augmentation Effect of Alveolar Bone Graft

  • Lee, Woojin;Park, Hyung Joon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il
    • Archives of Plastic Surgery
    • /
    • 제40권5호
    • /
    • pp.542-545
    • /
    • 2013
  • Background The aims of alveolar bone grafting are closure of the fistula, stabilization of the maxillary arch, support for the roots of the teeth adjacent to the cleft on each side. We observed nostril base augmentation in patients with alveolar clefts after alveolar bone grafting. The purpose of this study was to evaluate the nostril base augmentation effect of secondary alveolar bone grafting in patients with unilateral alveolar cleft. Methods Records of 15 children with alveolar clefts who underwent secondary alveolar bone grafting with autogenous iliac cancellous bone between March of 2011 and May of 2012 were reviewed. Preoperative and postoperative worm's-eye view photographs and reconstructed three-dimensional computed tomography (CT) scans were used for photogrammetry. The depression of the nostril base and thickness of the philtrum on the cleft side were measured in comparison to the normal side. The depression of the cleft side pyriform aperture was measured in comparison to the normal side on reconstructed three-dimensional CT. Results Significant changes were seen in the nostril base (P=0.005), the philtrum length (P=0.013), and the angle (P=0.006). The CT measurements showed significant changes in the pyriform aperture (P<0.001) and the angle (P<0.001). Conclusions An alveolar bone graft not only fills the gap in the alveolar process but also augments the nostril base after surgery. In this study, only an alveolar bone graft was performed to prevent bias from other procedures. Nostril base augmentation can be achieved by performing alveolar bone grafts in children, in whom invasive methods are not advised.