• Title/Summary/Keyword: base concrete

Search Result 687, Processing Time 0.034 seconds

A study on Improving the Durability of the Base Concrete Using Blast Furnace Slag (고로슬래그를 활용한 바탕콘크리트 내구성 향상에 대한 연구)

  • Jang, Yong;Kang, Ye-Jin;Lee, Dong-Oun;Kim, Dae-Geon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.36-37
    • /
    • 2021
  • When the final finish of a building is designed with base concrete, complex deterioration occurs due to the harsh environment such as shrinkage and expansion due to external temperature changes, freezing and thawing, and the use of calcium chloride due to snow accumulation. Therefore, the pozzolanic reaction mechanism of blast furnace slag is clearly identified, and the causal relationship between the material properties and performance of the blast furnace slag is identified to present guidelines for mixing high-durability concrete.

  • PDF

Ratio of predicted and observed natural frequency of finite sand stratum

  • Prathap Kumar, M.T.;Ramesh, H.N.;Raghavendra Rao, M.V.;Raghunandan, M.E.
    • Geomechanics and Engineering
    • /
    • v.1 no.3
    • /
    • pp.219-239
    • /
    • 2009
  • Vertical vibration tests were conducted using model footings of different size and mass resting on the surface of finite sand layer with different height to width ratios and underlain by either rigid concrete base or natural red-earth base. A comparative study of the ratio of predicted and observed natural frequency ratio of the finite sand stratum was made using the calculated values of equivalent stiffness suggested by Gazetas (1983) and Baidya and Muralikrishna (2001). Comparison of results between model footings resting on finite sand stratum underlain by the rigid concrete base and the natural red-earth base showed that, the presence of a finite base of higher rigidity increases the resonant frequency significantly. With increase in H/B ratio beyond 2.0, the influence of both the rigid concrete and natural red-earth base decreases. Increase in the contact area of the footing increases the resonant frequency of the model footings resting on finite sand stratum underlain by both the types of finite bases. Both the predicted and the observed resonant frequency ratio decreases with increase in force rating and height to width ratio for a given series of model footing.

Effect of Fly-Ash on the Characteristic of Chloride ion Penetration in Concrete (플라이 애쉬 치환율에 따른 콘크리트의 염소이온 투과특성)

  • 하재담;김태홍;유재상;이종열;박찬규;김상윤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.39-42
    • /
    • 2002
  • Cloride attack of concrete is one of the important causes of corrosion of reinforcing steel in concrete with carbonation and frost damage. In this paper, the effect of fly-ash on the cloride attack were investigated by varying water binder ratio and fly-ash contents according to the chloride ion penetrationa test. (ASTM C 1202-94) The principal conclusions from this research were as follows: 1) The compressive strength of concrete at large ages, depends more on $C_2$S contents of base cement than fly-ash contents. 2) On the other hand, the chloride ion penetration of concrete at large ages, principally depends on fly-ash contents and the influence of type of base cement is insignificant.

  • PDF

A Fundamental Study for the Practical Use of Liquid Segregation Reducing Type Superplasticizer (액상 분리저감형 유동화제의 실용화를 위한 기초적 연구)

  • 진의영;전충근;오선교;한천구;반호영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.297-300
    • /
    • 1998
  • Usually the flowing concrete manufactured upon normal-mixed base concrete would segregate due to the less of fine particle content. In the previous studies, a new type admixture(liquid segregation reducing type superplasticizer) has been developed to prevent such segregation without modification of base concrete mixture. In this study, the tests are performed in laboratory to evaluate the admixture by analyzing the properties of flowing concrete with different water to cement ratios, so that it could be used in the fields. According to the results, this kind of superplasticizer could improve the fluidity of concrete without causing segregation. However, it seems to be more desirable of the superplasticizer could be adjusted, before it is put into the practical use, not to cause some other problems such as rapid rate of slump and air loss and retarding of setting time.

  • PDF

A Study for Developing Construction Goods by Waste-Concrete (폐콘크리트를 이용한 건자재 상품화 개발은 위한 연구)

  • 남기룡;서치호;이광명;이건영;최경선
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.64-69
    • /
    • 1996
  • As Waste-concretes generated in construction field are increasing, it is becoming difficult and expensive to dispose them. For environmental reasons, many attempts have been made to find ways of reusing these materials. However, very little waste-concrete is currently recycled or reused anywhere on the world. Recycled concrete is mainly used as nonstabilized base of sub-base in highway construction. In this study, in order to promote the reuse of the waste-concretes, no-fines concrete blocks using recycled concrete aggregates were produced and their properties are evaluated. From the test results about strengths, pemeability, and durability, it is known that to use recycled aggregates for construction goods is promising and economical.

  • PDF

Design of Base Isolated Building Considering Performance Based Design (구조성능 목표를 고려한 면진설계)

  • Hwang, Kee-Tae;Lee, Hyun-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.700-703
    • /
    • 2004
  • The purpose of this study is to present the design methodology of base isolated buildings. To achieve the goal of this study, time-history analysis was performed with seismic performance level and recorded seismic data. From the analysis results of MDOF system, the maximum. displacement and base shear were evaluated as 25 cm and $4\%$ by the input level which is maximum velocity of 50 kine. By introducing hybrid isolation system, seismic energy can be concentrated consequently high seismic capacity of the total building is secured.

  • PDF

Determination of lateral strength and ductility characteristics of existing mid-rise RC buildings in Turkey

  • Ucar, Taner;Merter, Onur;Duzgun, Mustafa
    • Computers and Concrete
    • /
    • v.16 no.3
    • /
    • pp.467-485
    • /
    • 2015
  • This paper presents a comprehensive work on determination of yield base shear coefficient and displacement ductility factor of three to eight story actual reinforced concrete buildings, instead of using generic frames. The building data is provided by a walkdown survey in different locations of the pilot areas. Very detailed three dimensional models of the selected buildings are generated by using the data provided in architectural and reinforcement projects. Capacity curves of the buildings are obtained from nonlinear static pushover analyses and each capacity curve is approximated with a bilinear curve. Characteristic points of capacity curve, the yield base shear capacity, the yield displacement and the ultimate displacement capacity, are determined. The calculated values of the yield base shear coefficients and the displacement ductility factors for directions into consideration are compared by those expected values given in different versions of Turkish Seismic Design Code. Although having sufficient lateral strength capacities, the deformation capacities of these typical mid-rise reinforced concrete buildings are found to be considerably low.

A Study on the Utilization of Industrial Waste to Improve the Durability of Base Concrete (바탕콘크리트 내구성 향상을 위한 산업폐기물 활용에 관한 연구)

  • Kim, Dae-Geon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.107-108
    • /
    • 2022
  • This study aims to solve environmental problems by reducing complex degradation and recycling industrial waste by utilizing waste fibers and blast furnace slags, which are industrial by-products. In addition, it is intended to secure long-term durability to reduce cracks. To this end, the disadvantages of fiber-reinforced concrete are to solve the problem of lowering liquidity and ensuring curing time, and to find the optimal combination when waste fibers and blast furnace slag are used together.

  • PDF

An experimental study on different socket base connections under cyclic loading

  • Pul, Selim;Husem, Metin;Arslan, Mehmet Emin;Hamzacebi, Sertac
    • Computers and Concrete
    • /
    • v.13 no.3
    • /
    • pp.377-387
    • /
    • 2014
  • This paper presents an experimental study on socket base connections of precast reinforced concrete columns. The main purpose of this study is to determine socket base connection which has the closest behavior to monolithic casted column-base joints. For this purpose, six specimens having different column-socket base connection details were tested under cyclic loading. For each test, strength, stiffness, ductility and drift ratios of the specimens were determined. Test results indicated that a suggested connection type is 10%-30% stronger than the other type of connections under lateral loading. The welded connection (PC-5) had better lateral load carrying capacity and ductility. On the other hand, performance of standard connection (PC-1) which is commonly used in construction was weaker than other connections. Thus, decision of connection type should be referred not only performance but also applicability.

Bond Characteristics at the Interface between HMA Surface and RCC Base (아스팔트 표층과 RCC 기층 계면에서의 부착특성 연구)

  • Hong, Ki;Kim, Young Kyu;Bae, Abraham;Lee, Seung Woo
    • International Journal of Highway Engineering
    • /
    • v.19 no.6
    • /
    • pp.37-46
    • /
    • 2017
  • PURPOSES : A composite pavement utilizes both an asphalt surface and a concrete base. Typically, a concrete base layer provides structural capacity, while an asphalt surface layer provides smoothness and riding quality. This pavement type can be used in conjunction with rollercompacted concrete (RCC) pavement as a base layer due to its fast construction, economic efficiency, and structural performance. However, the service life and functionality of composite pavement may be reduced due to interfacial bond failure. Therefore, adequate interfacial bonding between the asphalt surface and the concrete base is essential to achieving monolithic behavior. The purpose of this study is to investigate the bond characteristics at the interface between asphalt (HMA; hot-mixed asphalt) and the RCC base. METHODS : This study was performed to determine the optimal type and application rate of tack coat material for RCC-base composite pavement. In addition, the core size effect, temperature condition, and bonding failure shape were analyzed to investigate the bonding characteristics at the interface between the RCC base and HMA surface. To evaluate the bond strength, a pull-off test was performed using different diameters of specimens such as 50 mm and 100 mm. Tack coat materials such as RSC-4 and BD-Coat were applied in amounts of 0.3, 0.5, 0.7, 0.9, and $1.1l/m^2$ to determine the optimal application rate. In order to evaluate the bond strength characteristics with temperature changes, a pull-off test was carried out at -15, 0, 20, and $40^{\circ}C$. In addition, the bond failure shapes were analyzed using an image analysis program after the pull-off tests were completed. RESULTS : The test results indicated that the optimal application rate of RSC-4 and BD-Coat were $0.8l/m^2$, $0.9l/m^2$, respectively. The core size effect was determined to be negligible because the bond strengths were similar in specimens with diameters of 50 mm and 100 mm. The bond strengths of RSC-4 and BD-Coat were found to decrease significantly when the temperature increased. As a result of the bonding failure shape in low-temperature conditions such as -15, 0, and $20^{\circ}C$, it was found that most of the debonding occurred at the interface between the tack coat and RCC surface. On the other hand, the interface between the HMA and tack coat was weaker than that between the tack coat and RCC at a high temperature of $40^{\circ}C$. CONCLUSIONS : This study suggested an optimal application rate of tack coat materials to apply to RCC-base composite pavement. The bond strengths at high temperatures were significantly lower than the required bond (tensile) strength of 0.4 MPa. It was known that the temperature was a critical factor affecting the bond strength at the interface of the RCC-base composite pavement.