• Title/Summary/Keyword: base acceleration

Search Result 331, Processing Time 0.028 seconds

Gait-Event Detection using an Accelerometer for the Paralyzed Patients (가속도계를 이용한 마비환자의 보행이벤트 검출)

  • Kong, Se-Jin;Kim, Chul-Seung;Moon, Ki-Wook;Eom, Gwang-Moon;Tack, Gye-Rae;Kim, Kyeong-Seop;Lee, Jeong-Whan;Lee, Young-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.990-992
    • /
    • 2007
  • The purpose of this study is to develop a practical gait-event detection system which is necessary for the FES (functional electrical stimulation) control of locomotion in paralyzed patients. The system is comprised of a sensor board and an event recognition algorithm. We focused on the practicality improvement of the system through 1) using accelerometer to get the angle of shank and dispensing with the foot-switches having limitation in indoor or barefoot usage and 2) using a rule-base instead of threshold to determine the heel-off/heel-strike events corresponding the stimulation on/off timing. The sensor signals are transmitted through RF communication and gait-events was detected using the peaks in shank angle. The system could detect two critical gait-events in all five paralyzed patients. The standard deviation of the gait events time from the peaks were smaller when 1.5Hz cutoff frequency was used in the derivation of the shank angle from the acceleration signals.

Parametric study on dynamic behavior of rectangular concrete storage tanks

  • Yazdanian, Mohsen;Fu, Feng
    • Coupled systems mechanics
    • /
    • v.6 no.2
    • /
    • pp.189-206
    • /
    • 2017
  • Tanks are used to store a wide variety of liquids such as oil, gasoline and water. It is reported that, a large number of tanks have been damaged during severe earthquakes. Therefore, understanding their behavior under earthquake is an important subject for structural engineers. In this paper, a comprehensive study is presented on dynamic response of tanks. A parametric study has been completed on the rectangular storage tanks with aid of finite element method (FEM). Various parameters are investigated, such as; liquid height, density and earthquake with different peak ground acceleration (PGA). When investigating these parameters, modal and time history method is used. Six different earthquake records are used for time history analysis. The analysis results show that when the PGA increases by 10.7 times, the maximum displacements, stress, sloshing and base shear increase by 11.4, 22.6, 5.46 and 17.8 times, respectively and when the liquid height increases by two times, the absolute maximum values of stress, displacements, base shear and sloshing increase 1.65, 2.04, 2.05 and 1.34. Furthermore, values of sloshing increase with decrease in density.

Shaking Table Tests of 1/3-Scale 3-Story Wet-Jointed Precast Concrete Large Panel Box Model (1/3축소 3층 습식접합 프리캐스트 콘크리트 대형판 입체모델의 진동대 실험)

  • 이한선
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.1
    • /
    • pp.115-127
    • /
    • 1993
  • 본 연구의 목적은 프리캐스트 콘크리트(P.C) 대형판 아파트 구조물에 대한 우리나라 내진설계기준안 및 지침을 수립하기 위해 필요로 하는 정보를 취득하는데 있다. 이것은 실제 지진과 유사한 진동을 발생시키는 진동대를 사용하여 P.C대형판 구조물의 거동을 분석관찰함으로써 달성되었다. 여기에 사용된 시험체중의 하나는 습식접합 1/3 축소 3층 입체 P.C모델이었다. 지진파를 일으키기 위해 4mx4m 크기의 진동대가 사용되었다. 또한 선택한 입력지진가속도파는 Taft N21E 성분기록지진파로서 최대지진가속도(PGA)는 원하는 지진세기수준에 따라 조정되었고 시간축으로는 동적상사성법칙에 따라 축소되었다. 이 P.C모델의 진동대 실험을 통해 얻은 결과를 근거로 하여, 근거로 하여 다음과 같은 결론을 도출하였다. (1)이 시험체에 관한한, 지진안전계수는 7-8정도로 나타났으며, (2)이 P.C모델이 감쇠계수는 대체로, 철근콘크리트구조물 감쇠계수의 두배에 해당하는 값인 8%정도이며, (3) 이 모델은 접합부의 벌어짐과 미끄러짐에 의한 에너지소산을 통해서 2-3정도의 전체적인 변위연성비를 보여주었다.

Design of Falling Recognition Application System using Deep Learning

  • Kwon, TaeWoo;Lee, Jong-Yong;Jung, Kye-Dong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.120-126
    • /
    • 2020
  • Studies are being conducted regarding falling recognition using sensors on smartphonesto recognize falling in human daily life. These studies use a number of sensors, mostly acceleration sensors, gyro sensors, motion sensors, etc. Falling recognition system processes the values of sensor data by using a falling recognition algorithm and classifies behavior based on thresholds. If the threshold is ambiguous, the accuracy will be reduced. To solve this problem, Deep learning was introduced in the behavioral recognition system. Deep learning is a kind of machine learning technique that computers process and categorize input data rather than processing it by man-made algorithms. Thus, in this paper, we propose a falling recognition application system using deep learning based on smartphones. The proposed system is powered by apps on smartphones. It also consists of three layers and uses DataBase as a Service (DBaaS) to handle big data and address data heterogeneity. The proposed system uses deep learning to recognize the user's behavior, it can expect higher accuracy compared to the system in the general rule base.

Dynamic Stability Analysis of Base-Isolated Low-level Nonlinear Structure Under Earthquake Excitation (지진시 저층건물 면진구조의 비선형 동적 거동)

  • Mun, Byeong-Yeong;Gang, Gyeong-Ju;Gang, Beom-Su;Kim, Gye-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1743-1750
    • /
    • 2001
  • This paper presents an analysis of nonlinear response of the seismically isolated structure against earthquake excitation to evaluate isolation performances of a rubber bearing. In the analysis of the vibration of building, the building is modeled by lumped mass system where the restoring force is considered as linear, bilinear and trilinear. Fundamental equations of motion are derived for the base isolated structure, and hysteretic and nonlinear-elastic characteristics are considered for a numerical calculation. The excitation levels are magnified fur the recorded strong earthquake motions in order to examine dynamic stability of the structure. Seismic responses (of the building are compared fur the each restoring force type. As a result, it is shown that the effect of the motion by the nonlinear response of the building is comparatively not so large from a seismic design standpoint. The responses of the isolated structures reduce sufficiently and controled the motion of the building well in a practical range. By increasing the acceleration of the earthquake, the yielding of the farce was occurred in the concrete and steel frame, which shows the necessity of the exact nonlinear dynamic analysis.

The Absolute Gravity Measurements in Korean Peninsula (한반도지역에서의 절대 중력관측)

  • 조진동;김경수;안기덕;우삼용
    • Economic and Environmental Geology
    • /
    • v.36 no.5
    • /
    • pp.387-389
    • /
    • 2003
  • For the establishing gravity base station and the improving the precision of exiting gravity network, and getting the gravity acceleration value in Korea, the absolute gravity measurements have been conducted at Daejeon(KRISS) from October 8 to November 8, 1996 with the NIM-II Absolute gravimeter and Suwon(NGI) from December 10 to December 16, 1999 with the FG5 Absolute gravity meter. The each absolute gravity value measured at KRISS and at NGI is 979,829.609${\pm}$0.006 mGal from 353 dropes and 979,918.775${\pm}$0.0001 mGal from a total 14,346 dropes. I think that we need the many base Absolute gravity station for the activation of the Earth science.

Base Structure Design of Laptop HDD for Anti-Shock Performance (내충격 성능 향상을 위한 랩탑 하드디스크의 베이스 설계)

  • Lim, Seung-Ho;Park, No-Cheol;Park, Young-Pil;Park, Kyoung-Su;Seol, Woong;Kim, Kyung-Tae
    • Transactions of the Society of Information Storage Systems
    • /
    • v.5 no.2
    • /
    • pp.76-81
    • /
    • 2009
  • Mobile devices have become an important part of daily life. This is especially true of laptop PCs, which are portable enough to be used almost anywhere. Laptop PCs, however, cannot be nomadic if each component is not robust enough to endure rugged laptop operating environment. Generally, external shock makes collision on head-disk interface and damage to read-write performance. To minimize the likelihood of failure, shock analysis must be incorporated into the design of hard disk drive in laptop. This research explores the structure modification of laptop HDD base, for improving shock performance using finite element analysis which considers the flexibility of whole HDD structure. FE model is verified by modal test and finely tuned. Then we obtained the transmitted acceleration of spindle and pivot and the relative displacement between disk and slider head as shock response. Based on shock simulation, the structural dynamics modification is performed and the primary design parameters are extracted.

  • PDF

Behavior of Initiation and Propagation of Fatigue Crack under Periodic Overstressing(II) - About the Inside Crack of the Caron Steel- (過大, 過小應力下에서의 疲勞크랙發생 傳播擧動 (II) - 탄소동재의 내부크랙을 중심으로-)

  • 송삼홍;원시태
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.2
    • /
    • pp.188-197
    • /
    • 1986
  • With respect to structural carbon steel(SM 22C), it was studied how the overstress or the understress has effects on fatigue inside crack propagation curve of a two level stress. Obtained results are summarized as follows. (1) The overstress or the understress, at a slip band occurrence stage, does not change the inside crack propagation curve because the crack closure and opening phenomena do not happen. (2) The overstress, at a crack propagation stage, does not change the inside crack propagation curve because the crack closure of overstress in compressive state is nearly same that of base stress in compressive state. (3) The understress, at a crack propagation stage, give rise to an acceleration of crack growth because the crack closure of understree in compressive state is more open than that of base stress in compressive state and the phenomenon is the essential increase of the actual applied stress of the specimen.

Development of Modeling for Dynamic Response of EDF System (EDF 시스템의 동적 특성 연구를 위한 모델링 개발)

  • Han, Kyu Seung;Park, Sun Kyu;Lee, In Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.1
    • /
    • pp.218-227
    • /
    • 2001
  • The purpose of this study was to estimate that the relations of weathering speed and shear strength of granite soil by tracing the weathering depth of granite soil from the very moment of its cutting. The results obtained this follows : This paper is about seismic performance of the EDF(Electricite De France) system, that is among various base isolator. A rational modeling of EDF system has been presented that used Nllink element. We get theoretical solutions of equation of motion of the system and compared with numerical solutions using a finite element program. The unification modeling is made by comparing with behavior using Newmark-${\beta}$ method when input earthquake acceleration data. Thus, a verified modeling will apply bridge structures or multi-degree of-freedom systems.

  • PDF

Dynamic response of adjacent structures connected by friction damper

  • Patel, C.C.;Jangid, R.S.
    • Earthquakes and Structures
    • /
    • v.2 no.2
    • /
    • pp.149-169
    • /
    • 2011
  • Dynamic response of two adjacent single degree-of-freedom (SDOF) structures connected with friction damper under base excitation is investigated. The base excitation is modeled as a stationary white-noise random process. As the force-deformation behavior of friction damper is non linear, the dynamic response of connected structures is obtained using the equivalent linearization technique. It is observed that there exists an optimum value of the limiting frictional force of the damper for which the mean square displacement and the mean square absolute acceleration responses of the connected structures attains the minimum value. The close form expressions for the optimum value of damper frictional force and corresponding mean square responses of the coupled undamped structures are derived. These expressions can be used for initial optimal design of the friction damper for connected structures. A parametric study is also carried out to investigate the influence of system parameters such as frequency ratio and mass ratio on the response of the coupled structures. It has been observed that the frequency ratio has significant effect on the performance of the friction damper, whereas the effects of mass ratio are marginal. Finally, the verification of the derived close from expressions is made by correlating the response of connected structures under real earthquake excitations.