• Title/Summary/Keyword: balloon injury

Search Result 56, Processing Time 0.023 seconds

Mechanical Stretch-Induced Protection against Myocardial Ischemia-Reperfusion Injury Involves AMP-Activated Protein Kinase

  • Hao, Jia;Kim, Hun-Sik;Choi, Woong;Ha, Tae-Sun;Ahn, Hee-Yul;Kim, Chan-Hyung
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.14 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • AMP-activated protein kinase (AMPK) protects various tissues and cells from ischemic insults and is activated by many stimuli including mechanical stretch. Therefore, this study investigated if the activation of AMPK is involved in stretch-induced cardioprotection (SIC). Intraventricular balloon and aorto-caval shunt (ACS) were used to stretch rat hearts ex vivo and in vivo, respectively. Stretch preconditioning reduced myocardial infarct induced by ischemia-reperfusion (I/R) and improved post-ischemic functional recovery. Phosphorylation of AMPK and its downstream substrate, acetyl-CoA carboxylase (ACC) were increased by mechanical stretch and ACC phosphorylation was completely blocked by the AMPK inhibitor, Compound C. AMPK activator (AICAR) mimicked SIC. Gadolinium, a blocker of stretch-activated ion channels (SACs), inhibited the stretch-induced phosphorylation of AMPK and ACC, whereas diltiazem, a specific L-type calcium channel blocker, did not affect AMPK activation. Furthermore, SIC was abrogated by Compound C and gadolinium. The in vivo stretch induced by ACS increased AMPK activation and reduced myocardial infarct. These findings indicate that stretch preconditioning can induce the cardioprotection against I/R injury, and activation of AMPK plays an important role in SIC, which might be mediated by SACs.

Development of Sharpness Measuring Method for Glass Aggregate Particle made from Waste Glass Bottle

  • Sano, Shigeru;Yamada, Mari
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.76-79
    • /
    • 2001
  • In Japan in of today, there is no aspect in which the quantity of waste glass bottle discharged from ordinary homes decreases. Moreover, the kind of shape and color of the waste glass bottles are increasing little by little. In the recycling of the glass bottle, it becomes a problem that many kind of the color is abounding. It is possible to use the transparent glass bottle as raw material of the glassware. Since the reproduction of the color is difficult, the colored glass bottle is not possible to use as a raw material. Therefore, the processing of these glass bottles entirely depends on the reclamation. In Japan, the security of the new reclaimed land is very difficult for the reason of the environmental damage. Moreover, the life expectancy in many reclaimed lands is anticipated with within two years. Therefore, the development of the processing method of glass bottle other than reclamation becomes a rapid problem. At present it is examined that it is used of an aggregate of the colored pavement, as one of the application methods of colored glass bottle. The particle size of produced glass aggregate is also 5mm or less, because the thickness is 5mm or less on almost glass bottles. And almost glass particles have the sharp tip. The application as the aggregate is limited for this sharpness of the particle. This study was carried out for the purpose of the establishment of sharpness measuring method of the glass aggregate particle. It is possible that the injury degree to human in the handling is known, if showing the sharpness of the aggregate particle at the objective numerical value is possible. And the application of the glass aggregate is spread. In this research, the balloon fracture method was used for the sharpness measurement of the glass particle. This method is based on the completely new idea, and it is possible to express completely the possibility of injury to the human. It is reported with the detailed result in full paper, because this study is continuous in order to get the JIS which is industrial standard of Japan.

  • PDF

Spontaneous Perinephric Urinoma after the Removal of a Foley Catheter in a Girl with Acute Kidney Injury (급성 신부전 환아에서 유치 도뇨관 제거 후 발생한 신 주위 요낭종 1례)

  • Yang, Tae Hwan;Yim, Hyung Eun;Yoo, Kee Hwan
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.127-131
    • /
    • 2013
  • Urinomas can occur after renal trauma or perforation of the collecting system during an endosurgical procedure. However, spontaneous urinomas are very rare. Here we report a case of a spontaneous perinephric urinoma following the removal of a Foley catheter in an 18-year-old girl with acute kidney injury caused by septic shock. The patient had been treated for septic shock, acute kidney injury, and acute respiratory distress syndrome, and had a Foley catheter in place for seven days. After Foley catheter removal, the patient complained of consistent voiding difficulty. An abdominal computed tomography scan showed a large amount of left perinephric fluid, and the aspirated fluid included urothelial cells, confirming the diagnosis of a urinoma. The urinoma was successfully treated by insertion of a double-J stent into the left ureter. This report discusses the available literature on urinomas, and their clinical features, diagnosis, and treatment.

The Comparison of Outcome between Thromboaspiration and Aggressive Mechanical Clot Disruption in Treating Hyperacute Stroke Patients

  • Lee, Hyun-Goo;Rhim, Jong-Kook;Kim, Yoon-Hee;Sheen, Seung-Hun;Oh, Sung-Han;Chung, Bong-Sub
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.311-316
    • /
    • 2011
  • Objective : Stroke is the third leading cause of death in the Republic of Korea. Time is the most important factor in hyperacute stroke. Yet, there had been no protocol for mechanical thrombolysis. We have treated patients with hyperacute stroke by mechanical thrombolysis for 3 years. In current study, we analyzed the outcome of mechanical thrombolysis. Methods : From March 2008 to February 2011, 36 patients were treated with mechanical thrombolysis. Initially we treated the patients by aggressive mechanical clot disruption (AMCD) who were admitted within 6 hours after the symptom onset. If revascularization was not achieved, balloon angioplasty was performed, followed by stenting or temporary endovascular bypass was performed. The result in 15 cases was not so successful. Since then, we started using the thromboaspiration method as the first line treatment of the mechanical thrombolysis. Results : After using the thromboaspiration, we had better results in recanalization rate, modified Rankin Score (mRS) and reperfusion injury compared to AMCD. The recanalization rate was 80.85%, mRS is 2.85, and there was only 0.09% hemorrhagic formation. Conclusion : Even though thromboaspiration is not statistically significant due to the limited numbers of patients enrolled in this study, we think it is a good way in mechanical thronbolysis for hyperacute stroke.

Damage to the pilot balloon of the nasotracheal tube during orthognathic double-jaw surgery: A case report

  • Kim, Eun-Jung;Yoon, Ji-Young;Woo, Mi-Na;Kim, Cheul-Hong;Yoon, Ji-Uk;Jeon, Da-Nee
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.2
    • /
    • pp.101-103
    • /
    • 2015
  • In oral and maxillofacial surgery, many complications associated with nasotracheal tube can be caused. In this case, we reported ballooning tube damage of nasotracheal tube during orthognathic double-jaw surgery and replacement of tube through cut down of tube and tube exchange using airway exchange catheter. The patient scheduled for high Le Fort I osteotomy and bilateral sagittal split osteotomy was intubated nasotracheally with nasal endotracheal tube. During maxilla osteotomy, air bubble was detected in the oral blood. In spite of our repeated ballooning, the results were the same so we changed damaged tube using airway exchange catheter aseptically. Tiny and superficial cutting site was detected in the middle of pilot tube. As we know in our case, tiny injury impeded a normal airway management and prevention is important.

Comparison of Endoscopic Removal of Disk Batteries in Children (디스크 전지를 삼킨 소아에서 내시경적 이물 제거술의 비교)

  • Kim, Jung-Ok;Hong, Eun-Hui;Choe, Byung-Ho;Cho, Min-Hyun;Seo, Hye-Eun;Lim, Hae-Ri;Chu, Mi-Ae;Hwang, Su-Kyeong;Park, Sun-Min;Hong, Suk-Jin;Shim, Ye-Jee;Choi, Byung-Ho
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.2
    • /
    • pp.147-156
    • /
    • 2007
  • Purpose: Any battery impacted in the esophagus must be removed urgently because of the possibility of serious complications such as perforation, fistula, and mediastinitis. The use of endoscopic procedures was compared to find the most rapid, effective, and safe method to remove disk batteries. Methods: The cases of 24 children (9 males, mean age, 1.5 years) that had accidentally ingested disk batteries were reviewed. The patients had visited the Department of Pediatrics, Kyungpook National University Hospital from July 1997 to June 2007 for the removal of disk batteries. Endoscopic removal was attempted using a retrieval net or a magnetic extractor with a balloon (condom). The procedure times for removing the ingested battery were compared. Results: Children that ingested batteries with a larger diameter (20 mm) had a greater chance to have esophageal impaction with serious injury, such as esophageal mucosal necrosis or ulcers, as compared to the ingestion of smaller diameter batteries (10 mm) (p<0.01). Endoscopic removal of disk batteries was attempted either using a retrieval net in 10 children or by using a magnetic extractor with a balloon in 6 children. Endoscopic removal using a retrieval net was more effective (mean procedure time: 1.5 min) as compared to using a magnetic extractor with a balloon (mean procedure time: 3.3 min) (p<0.05). Conclusion: Both procedures, either using a retrieval net or a magnetic extractor with a balloon were effective in removing ingested disk batteries. Based on our experience, an endoscopic procedure using a retrieval net was a more effective method for foreign body removal.

  • PDF

Resuscitative Endovascular Balloon Occlusion of the Aorta in Impending Traumatic Arrest: Is It Effective?

  • Chung, Jae Sik;Kim, Oh Hyun;Kim, Seongyup;Jang, Ji Young;An, Gyo Jin;Jung, Pil Young
    • Journal of Trauma and Injury
    • /
    • v.33 no.1
    • /
    • pp.23-30
    • /
    • 2020
  • Purpose: Hemorrhagic shock is the leading cause of death in trauma patients worldwide. Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a technique used to improve the hemodynamic stability of patients with traumatic shock and to temporarily control arterial hemorrhage. However, further research is required to determine whether REBOA with cardiopulmonary resuscitation (CPR) in near-arrest or arrest trauma patients can help resuscitation. We analyzed trauma patients who underwent REBOA according to their CPR status and evaluated the effects of REBOA in arrest situations. Methods: This study was a retrospective single-regional trauma center study conducted at a tertiary medical institution from February 2017 to November 2019. We evaluated the mortality of severely injured patients who underwent REBOA and analyzed the factors that influenced the outcome. Patients were divided into CPR and non-CPR groups. Results: We reviewed 1,596 trauma patients with shock, of whom 23 patients underwent REBOA (1.4%). Two patients were excluded due to failure and a repeated attempt of REBOA. The Glasgow Coma Scale score was lower in the CPR group than in the non-CPR group (p=0.009). Blood pressure readings at the emergency room were lower in the CPR group than in the non-CPR group, including systolic blood pressure (p=0.012), diastolic blood pressure (p=0.002), and mean arterial pressure (p=0.008). In addition, the mortality rate was higher in the CPR group (100%) than in the non-CPR group (50%) (p=0.012). The overall mortality rate was 76.2%. Conclusions: Our study suggests that if REBOA is deemed necessary in a timely manner, it is better to perform REBOA before an arrest occurs. Therefore, appropriate protocols, including pre-hospital REBOA, should be constructed to demonstrate the effectiveness of REBOA in reducing mortality in arrest or impending arrest patients.

CAROTID-CAVERNOUS SINUS FISTULA ACCOMPANYING FACIAL BONE FRACTURE : Report of a Case (안면골 골절과 동반된 경동맥해면동루의 증례보고)

  • Park, No-Bu;Seo, Yeon-Ho;Moon, Seon-Hye;Lee, Yong-Oh
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.15 no.2
    • /
    • pp.100-104
    • /
    • 1993
  • Carotid-cavernous sinus fistula(CCSF) is an abnormal arterio-venous communication between the cavernous sinus and the internal carotid artery. It is usually caused by craniofacial trauma and a very rarely encountered complication, but it may also occur spontaneously. The most common cause of traumatic CCSF is blunt trauma, which usually associated with a skull base, frontal or midfacial fracture. The common clinical feature of CCSF are orbital bruit, headache, exophthalmos, chemosis, diplopia, visual disturbance and others. This dramatic ocular-orbital symptoms are principally due to orbital venous hypertension. The symptoms occured within a few hours to a maximum of a year after injury, usually within several weeks. The patient, 33-year-old female, developed a carotid-cavernous sinus fistula after only minimal closed trauma We present a rare case of CCSF associated facial bone fracture that was successfully treated by detachable balloon embolization with a review of the literature.

  • PDF

Restenosis and Remodeling (관동맥성형술 후의 혈관 재협착 및 재형성)

  • Chae, Jei-Keon
    • 대한핵의학회:학술대회논문집
    • /
    • 1999.05a
    • /
    • pp.205-208
    • /
    • 1999
  • Percutaneous Transluminal Coronary Angioplasty (PTCA) remains limited by restenosis that occurs in 30 to 50% of patients with coronary artery disease. During the last decade, numerous agents have been used to prevent restenosis. Despite positive results in animal models, no pharmacological therapy has been found to significantly decrease the risk of restenosis in humans. These discrepancies between animal models and clinical situation were probably related to an incomplete understanding of the mechanism of restenosis. Neointimal thickening occurs in response to experimental arterial injury with a balloon catheter. Neointimal formation involves different steps: smooth muscle cell activation, proliferation and migration, and the production of extracellular matrix. The factors that control neointimal hyperplasia include growth factors, humoral factors and mechanical factors. Arterial remodeling also plays a major role in the restenosis process. Studies performed in animal and human subjects have established the potentials for "constrictive remodeling" to reduce the post-angioplasty vessel area, thereby indirectly narrowing the vessel lumen and thus contributing to restenosis. The reduction of restenosis rate in patients with intracoronary stent implantation has been attributed to the preventive effect of stent itself for this negative remodeling. In addition to these mochanisms for restenosis, intraluminal or intra-plaque thrombus formation, reendothelialization and apoptosis theories have been introduced and confirmed at least in part.

  • PDF

Posterior Left Ventricular Wall Rupture After Mitral Valve Replacement (승모판 치환술후 발생한 좌심실 후벽 파열)

  • 강면식
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1254-1260
    • /
    • 1992
  • Rupture of the posterior left ventricular wall following mitral valve replacement is a rare but fatal complication. Over a 10 year period from August 25 1980 to November 27 1990, we have experienced 6 such patients among 884 cases of mitral valve replacement with 4 deaths and 2 survivors. One patient had a type I rupture and another a type II rapture with the remaining four patients having suffered type III ruptures. All of the ruptures were dis covered intraoperatively enabling prompt reinstitution of the cardiopulmonary bypass and subsequent cardioplegic arrest prior to repair. Overzealous removal of calcified valve leaflets seemed to be responsible for the single type I rupture, and untethering of the so called ventricular loop appeared to be the main mechanism responsible for the type III ruptures. The single type II rupture that had occurred seemed to have been caused by inadvertent laceration of the papillary muscle with resultant rupture of the posterior LV wall at the base of the papillary muscle. Among the type III ruptures, 2 patients required intraaortic balloon pump[IABP] support only for mechanical assistance and 1 patient required both the IABP and the Biomedicus LV assist device for successfull weaning following repair of the LV rupture Another patient with a type II rupture also required the circulatory assistance of both the IABP and the bio-medicus LV assist device for weaning from the bypass. Attention to meticulous technical considerations such as avoiding over aggressive removal of heavily calcified valvular tissue, preservation of as much mural leaflet tissue and chordal stuctures as possible seemed helpful in preventing this catastrophic complication from occurring. Fusion and fibrous stricture of the chordal structures appeared particularly conducive to the type II ruptures as a result of the increased susceptibility to papillary injury during operation.

  • PDF