• Title/Summary/Keyword: ballast water treatment

Search Result 91, Processing Time 0.023 seconds

A Study of Ecotoxicity Test for Byproducts of Ozone in the Ballast Water Treatment System with Ozonation

  • Park, Sung-Jin;Ha, Shin-Young;Kim, In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.35 no.9
    • /
    • pp.741-747
    • /
    • 2011
  • Ecological toxicity testing of the whole-effluent from the ozone ballast water treatment system was conducted as specified in the quality assurance project plans (QAPP). The growth inhibition test with microalgae, acute aquatic toxicity test with the Rotifer reproduction, toxicity test (or population growth) with the Rotifer, survival and growth toxicity test with larval fish and sediment toxicity test with amphipod were carried out to evaluate ecological toxicity on the movile test barge.

Ballast-water Microphytoplankton Diversity and Survivability from International Ships Berthed at Ulsan and Pyeongtaek Ports, Korea (울산과 평택항에 정박된 국제상선의 평형수에서 소형식물플랑크톤의 활성능력)

  • Baek, Seung-Ho;Jang, Min-Chul;Jang, Pung-Guk;Shin, Kyoung-Soon
    • Ocean and Polar Research
    • /
    • v.33 no.2
    • /
    • pp.113-125
    • /
    • 2011
  • In order to assess the survival success of microphytoplankton species in ship ballast water, we examined microphytoplankton diversity from international commercial ships berthed at Ulsan and Pyeongtaek Ports, Korea, and also subjected them to laboratory studies. The ages of ballast water in each ship ranged from 1 to 365 days. Vessels originated from coastal China (Weihai, Lianyunsang and Shanghai), Chile, and from the Yellow and Pacific Oceans. The numbers of species and phytoplankton standing crops in uploaded ballast water were significantly related to the age of ballast water. The most diverse taxonomic group was diatoms. In the laboratory study, the value of in vivo fluorescence in M/V Spring Lyra gradually increased with increasing nutrients such as nitrate and phosphate. Phytoplankton in new (9 days), medium (31 days) and old (365 days) ballast water successfully survived under typical nutrient condition of port water and F/2 medium at $15^{\circ}C$ and $20^{\circ}C$, whereas phytoplankton in ballast water treatment did not survive, regardless of optimal temperature. Colonization process was dominated by diatoms; Skeletonema coastatum for M/V Spring Lyra, Thalassiosira pseudonana and Thalassiosira for M/V Han Yang, Thalassiosira pacifica and Odontella aurita for M/V Modern Express, and Chaetoceros pseudocurvisetus and Pseudo-nitzschia seriata for M/V Asian Legend. The successful establishment of non-native species was also related to nutrient richness. Our laboratory design can be applied as a practical tool to assess the survivability of invasive microphytoplankton introduced into local waters of Ulsan and Pyeongtaek.

An Estimation of the Amount of Ship's Ballast Water to be Discharged at Korean Major Ports (국내 주요항만에서의 선박평형수 배출량 추정)

  • Choi, Hark-Sun;Kim, Han-Soo;Lee, Seung-Guk
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.4
    • /
    • pp.284-288
    • /
    • 2009
  • The International Convention for the Control and Management of Ships Ballast Water & Sediments was adopted by consensus at a diplomatic conference of IMO at 2004. To prepare the Ballast Water Management Convention, fundamental technologies such as treatment system, type approval, risk assessment and various technical informations for formulation of the regulation for national strategy shall be developed. The information item of voyage and discharge of ship's ballast water are gathered by visiting vessel and agent at port. Using the 97 results by ships type characteristic analysis on the relation between loading/unloading and discharge/uptake of ballast water, the amounts of discharge/uptake of ballast water at each port and all of country in Korea are predicted. Hence, It is apparent that the uptake of ballast water is predicted to about 70 million ton in total of Busan, Incheon, Kwangyang and Ulsan ports at 2006 which is over 3 times than discharges.

  • PDF

Sea water Treatment using an Automatic Backwashing Filter (자동역세척 여과장치를 이용한 해수처리)

  • Park Sang-Ho;Lim Jae-Dong;Kim In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.30 no.3 s.109
    • /
    • pp.241-245
    • /
    • 2006
  • Displayed result that handle particle contaminant and hydrospace organism included a number of ballast that is happened in ship using automatic back washing filter. Reason that removes first contaminant that is included in number of ballast is that heighten processing effectof after processing processof the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. The fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage. Filter rotation speed of filtration filter could be expose by 35mmHg more than 60 rpm and filter consecutively filtration pressure is 40.5mmHg in 20 rpm and 40 rpm are 36.6mmHg. Filtration system removal aquatic organism over $70{\mu}min$ ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

A Comparison Study on the Sterilization Effect of Ballast Water with Cylinder Type and Groove Type (선박평형수 처리장치의 cylinder type과 groove type의 살균효과 비교 연구)

  • Kang, Ah-Young;Kim, Sang-Pil;Kim, Young-Cheol;Song, Ju-Yeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.616-622
    • /
    • 2015
  • Current ballast water treatment technologies are applying chemical or electrical treatment technology which are not free from secondary environmental pollution. The purpose of this study is to treat the ballast water by shear stress without an additional environmental pollution and to find out the optimal treatment apparatus. We tried to treat ballast water by applying shear stress with two different type of combination of inner and outer cylinder, such as non-pattern type and groove type. In the case of non-pattern type of inner and outer cylinder, sterilization effect was comparatively low because of a slip between inner and outer cylinder. But in the case of groove type of inner and outer cylinder, sterilization effect was superior to the non-pattern type. With a same revolutional speed of 8000rpm, an extinction effect was acquired in the gap of 1 mm of inner and outer cylinder at non-pattern type, but 3mm of that of groove type.

Zooplankton Removal in Seawater using UV, Electrolysis and UV+electrolysis Process (UV, 전기분해 및 UV+전기분해 공정을 이용한 해수 중의 동물성 플랑크톤 제거)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.30 no.7
    • /
    • pp.597-604
    • /
    • 2021
  • The International Maritime Organization (IMO) ballast water management agreement (International Convention for the Control and Management of Ship's Ballast Water and Sediments) came into force on September 8, 2017. This study evaluated the disinfection performance of electrolysis, UV treatment, and electrolysis + UV combined, to improve the treatment of zooplankton (size ≥ 50 ㎛), which is expected to strengthen the standards for biodegradation efficiency. Among the methods used, the disinfection time leading to 100% death was in the order: electrolysis > electrolysis + UV > UV process. For the same level of disinfection performance, the amount of electricity required for the electrolysis, UV, and electrolysis + UV processes were 1,300 W.s, 8,400 W.S, and 4,500 W.s, respectively. The combination of electrolysis + UV process for inactivation of zooplankton in ballast water did not show a synergic effect owing to the slow disinfection time and high power consumption.

Numerical study on fluid characteristics due to disc shape in a novel mechanical ballast water treatment system (신개념 기계식 선박평형수 처리장치의 디스크 형상에 따른 유동특성에 관한 수치해석 연구)

  • Sohn, Sang-Ho;Kim, Young-Chul;Choi, Kung-Kwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.19-27
    • /
    • 2015
  • As the recent regulation of Internaional Maritime Organization (IMO) is enforced, the advanced technology of Ballast water treatment system (BWTS) is needed to meet its requirements. Until now, there are two kinds of the BWTS technologies such as physical methods (Membrane and UV) and chemical methods (Chlorin and Ozone). However, these conventional methods have some limitations of auxiliary power, low productivity, residual treatment and etc. In order to overcome these problems, this paper introduces the new kind of BWTS based on mechanical principle and investigates the effect of rotating disc shapes on flow characteristics between rotating and stationary discs by computational fluid dynamics (CFD). Planar and Step types can make the local cavitation generated along radius, and Circular type can increase the intensity of shear stress.

An Output Control Algorithm for Phase Shift Full Bridge Converter for Ballast Water Treatment (선박 평형수 처리용 Phase Shift Full Bridge Converter 출력 제어 알고리즘)

  • Lee, Sang-Ri;Kim, Hag-Wone;Cho, Kwan-Yuhl;Jung, Ho-Chul;Kim, Jong-Hyug;Park, Gwi-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.530-539
    • /
    • 2013
  • In large vessels, proper water level must be maintained with a balance for right and left equilibrium by absorbing or draining sea water in ballast water tank. However, this ship's ballast-water can be drained marine organisms to local sea area by world trade and this can be a source of ecological disturb. In order to solve these problems, marine organisms must be removed in accordance with the international covenant for the emission of microorganisms. By this reason, the seawater electrolysis rectifier of low-voltage high-current rectifiers with excellent ability for microbial treatment is required. In this paper, PSFB converter will be discussed for the seawater electrolysis rectifier. Furthermore, a new output control method with the power limit operation under the limited maximum voltage condition is proposed for this rectifier. The simulation for the proposed current control method for PSFB Converter is shown using MATLAB/SIMULINK. Finally the usefulness of the proposed control method is presented by the experimental results.

Design and Fabrication of a Ballast Water Treatment System Using UV Lamps (자외선램프를 이용한 선박평형수 처리시스템의 설계 및 제작)

  • Pyo, Tae-Sung;Cheon, Sang-Gyu;Park, Dae-Won;Choi, Sung-Kuk;Kim, Seong-Yeon;Kil, Gyung-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.952-958
    • /
    • 2009
  • The International Maritime Organization (IMO) has adopted the ballast water management convention at a diplomatic conference in early 2004 that all ships should be equipped with a treatment system from 2010 gradually. In this paper, the disinfection characteristic of ultra-violet (UV) rays was studied and a ballast water treatment system (BWTS) which can treat $50m^3$/h sea water was manufactured. The system consists of a disinfection chamber with six 3.5 kW UV lamps which are operated by magnetic ballasts, a programmable logic controller (PLC) and set of pipe lines. The biological disinfection efficacy of the prototype BWTS was evaluated following the IMO rules using zooplankton such as Artemia and Rotifer species for the size over $50{\mu}m$, and phytoplankton such as Tetraselmis and Thalassiosira species for the size between 10 to $50{\mu}m$. From the experimental results, the disinfection efficacy was 99.99 % that meets the IMO requirement. However, more studies on an energy saving system are needed because the consumption power of the prototype system is as high as over 21 kWh for $50m^3$/h.

Ballast water Treatment using a Multistage Filter (다단 디스크 여과장치를 이용한 선박 밸러스트수 처리)

  • Park, Sang-Ho;Lim, Jae-Dong;Kim, In-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.79-83
    • /
    • 2006
  • Displayed result that handle particle contaminant and hydrospace organism included in number of ballast that is happened in ship using automatic bade washing filter. Reason that remove first contaminant that is included in number of ballast is that heighten processing effect of after processing process. of the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. The fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage. Filter rotation speed at 1.0rpm is filter resistance 3.0bar and 3.0rpm is filter resistance 2.8bar. Filter out impurities from ballast water over 6.0rpm is filter resistance 26bar and 10rpm is filter resistance 2.5bar. Filtration system removal aquatic organism over $80{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

  • PDF