• Title/Summary/Keyword: background test

Search Result 3,780, Processing Time 0.031 seconds

$CO_2^*$ Background Effect on $OH^*$ and $CH^*$ Chemiluminescence Intensities in a Gas Turbine Combustor (가스터빈 연소기에서 $CO_2^*$ 배경 강도가 $OH^*$$CH^*$ 화학 발광 강도에 미치는 영향)

  • Kim, Dae-Sik;Lee, Jong-Guen
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.4
    • /
    • pp.37-42
    • /
    • 2010
  • The measurement of heat release rate is of great importance in the study of thermo-acoustic instability occurring in lean premixed combustion and the chemiluminescence emission has been used as an indicator of heat release in combustion instability studies primarily for its relative simplicity. This paper presents results of experimental study of flame chemiluminescence from an atmospheric, swirl-stabilized, turbulent lean premixed flame with a main emphasis on the effect of $CO_2^*$ background level in the $CH^*$ and $OH^*$ band. The test results show that the effect of $CO_2^*$ level in the $CH^*$ band is greater than that in the $OH^*$ band. Also, the background to peak ratio for both $CH^*$ and $OH^*$ bands can be expressed as a function of equivalence ratio, almost regardless of a change in the inlet velocity.

A Study on the Background Image Updating Algorithm for Detecting Fast Moving Objects (고속 객체 탐지를 위한 배경화면 갱신 알고리즘에 관한 연구)

  • Park, Jong-beom
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.4
    • /
    • pp.153-160
    • /
    • 2016
  • A developed skill of an intelligent CCTV is also advancing by using its Image Acquisition Device. The most important part in the field of detecting comparatively fast moving objects is to effectively reduce the loads on updating the background image in order to achieve real-time update. However, the ability of the current general-purpose computer extracting the texture as characteristics has limits in application mostly due to the loads on processes. In this thesis, an algorithm for real-time updating the background image in an applied area such as detecting the fast moving objects like a driving car in a video of at least 30 frames per second is suggested and the performance is analyzed by a test of extracting object region from real input image.

A Study on the Relationship between Internet Addiction and Stress of College Students (대학생들의 스트레스와 인터넷 중독의 관계에 관한 연구)

  • Kim, Jung-Yeol;Lee, Sung-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.3
    • /
    • pp.243-250
    • /
    • 2007
  • The purpose of this study is to examine the relationship between internet addiction and stress of college students. To assess the degree of internet addiction, internet addiction test of the center for online addiction was completed. Subjects were divided into three group depending on internet addiction ; subjects with 20-49 internet scores were grouping as 'normal usage group', subjects with 50-79 internet scores were grouping as 'addiction tendency group', and subjects with more than 80 internet scores were grouping as 'internet addiction group'. In this study it is found that interpersonal relationship stress is significantly related to internet addiction. Also, the result of this study shows that home background stress and school background stress have influence on internet addiction.

  • PDF

Polaroid Film Defect Detection Using 2D - Continuous Wavelet Transform (2차원 연속 웨이블릿을 이용한 편광 필름 결함 검출)

  • Jung, Chang-Do;Kim, Se-Yun;Joo, Young-Bok;Yun, Byoung-Ju;Choi, Byung-Jae;Park, Kil-Houm
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.6
    • /
    • pp.743-748
    • /
    • 2009
  • In this paper, we propose an effective method to extract background components in automated vision inspection system for polarized film used in TFT LCD display panels. The test image signals are typically composed of three components such as ununiform background, random noises and target defect signals. It is important to analyze the background signal for accurate extraction of defect components. Two dimensional continuous wavelets with first derivative gaussian is used. This methods can be applied for reliable extraction of defect signal by elimination of the background signal from the original image. The proposed method outperforms over conventional FFT methods.

Tracer Experiment for the Investigation of Urban Scale Dispersion of Air Pollutants - An Improved Method for the Release and Determination of Perfluorocarbon Tracers in the Urban Atmosphere (추적자 확산 실험에 의한 서울 도심 확산 현상 연구 - 도시규모 대기확산 실험을 위한 PFCs 추적자 방출 및 분석 시스템의 개발 및 적용 연구)

  • Yoo, Eun-Jin;Lee, Chong-Bum;Ro, Chul-Un;Kim, Hye-Kyeong;Lee, Gang-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.5
    • /
    • pp.547-556
    • /
    • 2007
  • The release, sampling and analytical methods have been developed and tested for perfluorocarbons (PFCs) atmospheric tracers in order to gain insight into the atmospheric transport and dispersion over the urban conditions of Seoul, Korea. Although PFCs tracer experiments provide unique opportunities to test local and urban scale of transport and dispersion, no previous experiment with PFCs has been conducted in Korea. PMCH and PDCH were chosen as targeted tracers in our study due to their extreme low ambient concentrations and great sensitivities among various PFCs. For PFCs release system, a set of micro-metering pump, electronic balance, vaporizing furnace and high speed blower was constructed for precise and accurate release of tracers. The precision of released rate by this system was estimated to be 1%. Samplings of PFCs were carried out by fabricated portable air samplers with micro pumps and rotameters into glass tubes packed with 150 mg of Carboxen-569. The uncertainty of these sampling system was maintained below 14%. PMCH and PDCH were quantified in GC/ECD with preconditioned injection system to eliminate the interference compounds using traps and subsequent catalytic conversion system prior to column separation. Three intensive field test were undertaken during the springtime of 2002 to 2004 in eastern part of Seoul. Daily background samples were collected to characterize the background levels of PMCH and PDCH prior to their release. The observed background concentrations of PMCH ranged from 3.5 to 10.1 fL/L and varied randomly in location and time in this study. Its mean and standard variation of background concentration ($6.8{\pm}1.9\;fL/L$) are higher than those ($3.2{\sim}5.8\;fL/L$) of other historic tracer studies. Identified uncertainty for background PMCH was $1.7{\sim}2.0\;fL/L$ using this analytical system. Combined relative uncertainty in determining the tracer's concentrations was estimated as 17%. However, its background concentrations and uncertainty in concentration determination were found to be low and stable enough for tracer study.

Web-based Video Monitoring System on Real Time using Object Extraction and Tracking out (객체 추출 및 추적을 이용한 실시간 웹기반 영상감시 시스템)

  • 박재표;이광형;이종희;전문석
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.41 no.4
    • /
    • pp.85-94
    • /
    • 2004
  • Object tracking in a real time image is one of interesting subjects in computer vision and many Practical application fields during the past couple of years. But sometimes existing systems cannot find all objects by recognizing background noise as object. This paper proposes a method of object detection and tracking using adaptive background image in real time. To detect object which is not influenced by illumination and to remove noise in background image, this system generates adaptive background image by real time background image updating. This system detects object using the difference between background image and input image from camera. After setting up Minimum Bounding Rectangle(MBR) using the internal point of detected object, the system tracks object through this MBR In addition, this paper evaluates the test result about performance of proposed method as compared with existing tracking algorithm.

5-year-old Students' Attitude Toward Science in Relation to Their Gender and Teachers' Background (유아의 성과 교사 변인에 따른 유아의 과학에 대한 태도)

  • Cho, Boo-Kyung;Go, Young-Mi
    • Journal of The Korean Association For Science Education
    • /
    • v.24 no.5
    • /
    • pp.833-842
    • /
    • 2004
  • The purpose of this study was to explore kindergarten students' attitude toward science by their gender and teachers' background. 90 kindergarten teachers and 180 5-year-old students were intentionally sampled in a suburban area. The research instruments used in this study were the interview questions of student attitude to science and the teacher's background questionnaire. The interview questions constructed by two researchers, based on "The Students' Attitude to Science Scale"(Pell & Farvis, 2001). It was composed of 13 questions; 7 questions on preference for science and 6 on perception to science. The teacher's background questionnaire was consisted of I question on educational background, I on career, and 51 on scientific literacy("Test of Basic Scientific Literacy")(Laugksch & Spargo, 1996). The results revealed that the students' attitude to science was positive and was different by their teachers' educational background, not by their gender and their teacher's career and scientific literacy. However, the students showed different preference for science by their teachers' scientific literacy. These results imply that early childhood teachers should have enough chances to be more educated and to improve their scientific literacy.

An Implementation of a GPIAS Measurement System for Animal Tinnitus Detection and Study on Effect of Starting Point of Stimulus Background Sound on Startle Response (동물 이명 검사용 GPIAS 측정 장치 구현과 이를 통한 자극 배경음의 시작 시점이 놀람 반응에 주는 영향)

  • Jeon, Poram;Jung, Jae Yun;Lee, Seung-Ha;Park, Ilyong
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.410-414
    • /
    • 2013
  • As one of the effective methods for researching the objective tinnitus detection, the GPIAS (Gap Pre-pulse Inhibition of Acoustic Startle) measurement has been used to verify the existence of animal tinnitus objectively. The level and pattern of the background sound presented prior to a startle pulse are closely related with the GPIAS results. But the effect of the starting point of the background sound on animal startle responses has not been reported yet. In this paper, we present the implementation of a GPIAS measurement system based on an unconstrained enclosure to avoid animals' excessive constraint stress and deal with the animals' growth. After the performance of our implemented system has been tested through the animal experiment using 4 SD-rats, the effect of starting point of stimulus background sound on the startle response has been studied by the use of our implemented system. Through the results, it is verified that our system can measure the inhibition of animal startle responses due the gap pre-pulse for GPIAS calculation and the background sound starting point does not significantly effect on the startle response and the GPIAS values if the background sound continues for more than 300msec before a gap pre-pulse is presented.

Field Test on IEC60364-4-44 for the Application in Korean distribution system (IEC60364-4-44의 국내 배전계통 적용을 위한 실증시험)

  • Nam, Kee-Young;Choi, Sang-Bong;Jeong, Seong-Whan;Lee, Jae-Duck;Ryoo, Hee-Suk;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.486-487
    • /
    • 2006
  • The authors have studied on the application of IEC 60364-4-44 to Korean electrical installations of buildings from 2004 sponsored by Korean ministry of commerce, industry and energy and the test field is established in K.E.R.I. (Korea Electrotechnology Research Institute). This paper presents the summary results of establishment of test field and analysis for the application of IEC 60364 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, since Korean electric power distribution system is based on multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364-4-44 and to evaluate the standard is applicable to domestic rule for the protection against ground fault through the related test

  • PDF

An Experimental Study on the Pump Operating Characteristics with Low Flow Operation (펌프의 저 유량 운전특성에 관한 실험적 연구)

  • 오광석;신필권;박종호;심우건;조두연
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.85-96
    • /
    • 1999
  • For ASME Code pumps in nuclear power plants, inservice test is required to assess the operational readiness in accordance with ASME code and related regulations. The objective of this study therefore, is to develop the technical background of the degradation of pump performances and conditions due to low flow rate operation. In addition. the detection techniques of pump operating conditions are to be developed to enhance the safety and economy of nuclear power plants. A test loop consisted of pump, motor. water tank, flow rate measurements and piping system with flow control devices was established for this study. Two typical pumps, 1-stage volute pump and 3-stage turbine pump, were selected and the test was performed upon two major point of views ; i.e., pump discharge pressure pulsations analysis and pump vibration spectrum analysis. From the test results, it is concluded that (1) the pump vibration affected by the natural frequency of operating pump is significant in the low frequency zone (around 1 Hz) : the vibration amplitude. especially. is an important factor during low flow rate operation. and shall be monitored to ensure that it is within the limit of ASME OM code Part 6, (2) the vibration frequency and pump discharge pressure are affected by vane pass frequency and running speed, (3) the wave phenomena due to the compressiblity of water is anticipated during low flow rate operation. and the pump system shall be designed to prevent it and. finally, (4) the technical background of the degradation of pump performances and conditions due to low flow rate operation is provided.

  • PDF