• 제목/요약/키워드: background concentration

검색결과 1,397건 처리시간 0.026초

Thoracic and Cardiovascular Surgeons' Perception of the Concentration of Cardiovascular Operations in Seoul Metropolitan Area's Hospitals

  • Jeong, Hyo Seon;Lee, Kun Sei;Chee, Hyun Keun;Ahn, Hye Mi;Sim, Sung Bo
    • Journal of Chest Surgery
    • /
    • 제49권sup1호
    • /
    • pp.53-59
    • /
    • 2016
  • Background: The purpose of this study is to evaluate the concentration of cardiovascular surgical procedures in a metropolitan area and investigate the perception of specialists regarding governmental policies to resolve this imbalance. Methods: From March to May 2015, surveys were distributed to members of the Thoracic and Cardiovascular Surgery Association. The final pool of research subjects consisted of 75 respondents. Subjects were queried regarding the concentration of cardiovascular operations in metropolitan areas, alternatives to the imbalance, and governmental policies to resolve the inequalities. Results: Survey participants responded that South Korea needs governmental policies to alleviate the concentration of cardiovascular surgery patients in large metropolitan hospitals. Participants agreed that the freedom to choose medical institutions and improved accessibility to metropolitan hospitals due to advanced transportation systems were some of the causes for the concentration. A majority (98.7%) of respondents thought establishing thoracic and cardiovascular surgery centers in provinces was an appropriate solution to alleviate the concentration. Thoracic and cardiovascular surgery specialists were ranked as the number one group on which to focus development. Conclusion: Developing and carrying out policies to establish thoracic and cardiovascular surgery centers in provinces will alleviate the regional imbalance in available heart surgery services and an overall improvement in cardiovascular disease treatment in South Korea.

상용치료원 보유가 의료기관 종별 선택에 미치는 영향: 대형병원 환자집중현상 완화방안을 중심으로 (The Effect of Having Usual Source of Care on the Choice among Different Types of Medical Facilities)

  • 김두리
    • 보건행정학회지
    • /
    • 제26권3호
    • /
    • pp.195-206
    • /
    • 2016
  • Background: Concentration of patients to large hospitals is serious problem in Korea. The purpose of this paper is to propose appropriate policy direction to relieve concentration of patients to large hospitals. It is focused on evaluation of the possibility of family doctor system as a policy alternative to relieve concentration of patients to large hospital by empirically analyzing the effect of usual source of care (USC) on large hospitals medical care use. Methods: Korea Health Panel conducted 2009, 2012, 2013 by KIHASA (Korea Institute for Health and Social Affairs) and NHIS (National Health Insurance Service) was used for analysis. For dependent variables, first, the ratio of the amount of using large hospital to total amount of using medical care, and second, the amount of using large hospital are estimated. Independent variables are having an USC and type of USC. Panel analysis was done with above variables. Results: Main results are as follows. First, having an USC increases using large hospital. Second, having a domestic clinic type USC decreases using large hospital and ratio of using large hospital. Third, the effect of domestic clinic type USC is greater in older group, less income group, worse health status group, not having private insurance group, and having chronic disease group. Conclusion: These results show that family doctor program can be a policy alternative to relieve concentration of patients to large hospital. Nonetheless, primary care system in Korea is unsatisfied. It is recommended to reinforce primary care system and family doctor system to relieve concentration of patients to large hospitals.

직업적으로 스티렌에 노출된 근로자의 뇨중 대사산물에 관한 연구 (A study on the urinary metabolites of styrene exposed workers)

  • 오세욱;원정일
    • 환경위생공학
    • /
    • 제11권3호
    • /
    • pp.1-7
    • /
    • 1996
  • Mandelic acid is the major metabolite and phenylglyoxylic acid is the minor metabolite of styrene in human. This study was conducted to investigate the correlation between exposure concentrations of styrene and concentration of the metabolites in urine The concentrations of metabolites in urine and exposure concentrations were measured in 60 workers who were occupationally exposed to styrene in FRP industry as well as paint industry and musical instrument manufacturing industry and the concentrations of metabolites in urine ware measured in 90 workers not occupationally exposed to styrene for review the background level in the unexposed population. The results obtained were as follows; 1. The mean exposure concentration is 16.6 $\pm $12.2 ppm (range 0.4-49.9ppm) in the styrene exposed workers. 2. The concentration of mandelic acid in urine collected at the end of shift from worker exposed 8 hours to 50ppm of styrene, based on extrapolation from correlation equations was 578.5 mg/g creatinine and 176.8 mg/g creatinine for next morning urine, the concentration of phenylglyoxylic acid in urine collected at the end of shift was 291.1 mg/g creatinine, 177.9 mg/g creatinine in next morning urine. In the sum of mandelic acid and phenylglyoxylic acid in the urine 870.2 mg/g creatinine in urine sampled at the end of shift corresponds to an exposure of 50ppm of styrene and 366.0 mg/g creatinine for next morning sample corresponds to 50ppm. 3. The correlation of the degree of exposed with sum concentration of mandeliacid and phenylglyoxylic acid in the urine was better(r=0.079 for end of shift, r=0.78 for next morning) than the correlation with single determinant measurement in urine(r=0.75 for mandelic acid at end of shift, r=0.73 for mandelic acid at next morning, r=0.69 for phenylglyoxylic acid at end of shift, r=0.62 for phenylglyoxylic acid at next morning). The monitoring of sum concentration of mandelic acid and phenylglyoxylic acid in urine is a valuable indicator of time weighted average daily exposure ti styrene. And the exposure standard of urinary metabolites produced by styrene should be set, in distinction urine at the end of shift from urine at next morning.

  • PDF

Evaluation of the disinfectant concentration used on livestock facilities in Korea during dual outbreak of foot and mouth disease and high pathogenic avian influenza

  • Kim, Seongjoon;Chung, Hansung;Lee, Hyesook;Myung, Donghoon;Choi, Kwanghoon;Kim, Sukwon;Htet, Swe Lynn;Jeong, Wooseog;Choe, Nonghoon
    • Journal of Veterinary Science
    • /
    • 제21권3호
    • /
    • pp.34.1-34.10
    • /
    • 2020
  • Background: A nationwide outbreak of foot-and-mouth disease (FMD) in South Korea caused massive economic losses in 2010. Since then, the Animal and Plant Quarantine Agency (QIA) has enhanced disinfection systems regarding livestock to prevent horizontal transmission of FMD and Avian influenza (AI). Although the amount of disinfectant used continues to increase, cases of FMD and AI have been occurring annually in Korea, except 2012 and 2013. Objectives: This study measured the concentration of the disinfectant to determine why it failed to remove the horizontal transmission despite increased disinfectant use. Methods: Surveys were conducted from February to May 2017, collecting 348 samples from disinfection systems. The samples were analyzed using the Standards of Animal Health Products analysis methods from QIA. Results: Twenty-three facilities used inappropriate or non-approved disinfectants. Nearly all sampled livestock farms and facilities-93.9%-did not properly adjust the disinfectant concentration. The percentage using low concentrations, or where no effective substance was detected, was 46.9%. Furthermore, 13 samples from the official disinfection station did not use effective disinfectant, and-among 72 samples from the disinfection station-88.89% were considered inappropriate concentration, according to the foot-and-mouth disease virus guidelines; considering the AIV guideline, 73.61% were inappropriate concentrations. Inappropriate concentration samples on automatic (90.00%) and semi-automatic (90.90%) disinfection systems showed no significant difference from manual methods (88.24%). Despite this study being conducted during the crisis level, most disinfectants were used inappropriately. Conclusions: This may partially explain why horizontal transmission of FMD and AI cannot be effectively prevented despite extensive disinfectant use.

Antibacterial activity of enrofloxacin loaded gelatin-sodium alginate composite nanogels against intracellular Staphylococcus aureus small colony variants

  • Luo, Wanhe;Liu, Jinhuan;Algharib, Samah Attia;Chen, Wei
    • Journal of Veterinary Science
    • /
    • 제23권3호
    • /
    • pp.48.1-48.12
    • /
    • 2022
  • Background: The poor intracellular concentration of enrofloxacin might lead to treatment failure of cow mastitis caused by Staphylococcus aureus small colony variants (SASCVs). Objectives: In this study, enrofloxacin composite nanogels were developed to increase the intracellular therapeutic drug concentrations and enhance the efficacy of enrofloxacin against cow mastitis caused by intracellular SASCVs. Methods: Enrofloxacin composite nanogels were formulated by an electrostatic interaction between gelatin (positive charge) and sodium alginate (SA; negative charge) with the help of CaCl2 (ionic crosslinkers) and optimized by a single factor test using the particle diameter, zeta potential (ZP), polydispersity index (PDI), loading capacity (LC), and encapsulation efficiency (EE) as indexes. The formation mechanism, structural characteristics, bioadhesion ability, cellular uptake, and the antibacterial activity of the enrofloxacin composite nanogels against intracellular SASCVs strain were studied systematically. Results: The optimized formulation was comprised of 10 mg/mL (gelatin), 5 mg/mL (SA), and 0.25 mg/mL (CaCl2). The size, LC, EE, PDI, and ZP of the optimized enrofloxacin composite nanogels were 323.2 ± 4.3 nm, 15.4% ± 0.2%, 69.6% ± 1.3%, 0.11 ± 0.02, and -34.4 ± 0.8 mV, respectively. Transmission electron microscopy showed that the enrofloxacin composite nanogels were spherical with a smooth surface and good particle size distributions. In addition, the enrofloxacin composite nanogels could enhance the bioadhesion capacity of enrofloxacin for the SASCVs strain by adhesive studies. The minimum inhibitory concentration, minimum bactericidal concentration, minimum biofilm inhibitory concentration, and minimum biofilm eradication concentration were 2, 4, 4, and 8 ㎍/mL, respectively. The killing rate curve had a concentration-dependent bactericidal effect as increasing drug concentrations induced swifter and more radical killing effects. Conclusions: This study provides a good tendency for developing enrofloxacin composite nanogels for treating cow mastitis caused by intracellular SASCVs and other intracellular bacterial infections.

라이다 시스템을 이용한 하층 대류권 오존농도 측정 (Ozone Monitoring in the Lower Tropospheric Atmosphere by LIDAR System)

  • 최성철;차형기;김덕현;김영상
    • 한국대기환경학회지
    • /
    • 제17권5호
    • /
    • pp.385-393
    • /
    • 2001
  • We have developed a Differential Absortion LIDAR (DIAL) method for the measurement of lower tropospheric ozone concentration. We used two laser beams from quadrupled Nd:YAG (266 nm) for the resonance wavelength and dye lasers (299.5 nm) for non -resonance wavelength. Aerosol extinction coefficients in the lower troposphere was computed by both Klett and Slope methods. To correct the SIN (Signal -Induced Noise) effect caused by photo detector, we subtracted a new-fitted baseline on the background part of a LIDAR signal, after the subtraction of the DC level. This is because SIN can be treated as an exponentially decaying tail. Using theme results, ozone profiles were obtained approximately 2km at daytime and 3km at nighttime. We compared the results derided by the Slope method with those measured by UV spectrometer. The computed results are in mostly good agreement with experimental results. In the measurement of the vertical layer, we observed the variation of the ozone profiles around the top mixed layer.

  • PDF

KrF 레이저를 이용한 희박연소화염과 매연화염에서의 NO계측 (NO measurements in lean and soot flame using KrF laser)

  • 손성민;고동섭;이중재;오승묵;강건용;김종욱
    • 한국광학회지
    • /
    • 제12권3호
    • /
    • pp.177-183
    • /
    • 2001
  • KrF 레이저를 여기광원으로 사용하여 희박연소화염과 매연화염에서 각각 청색편이된 NO형광 신호를 측정하였다. 두 화염에 대해서 여기광의 세기와 NO 첨가량에 따른 NO 신호와 배경잡음의 세기를 계측하고 그 결과를 정성적으로 분석하였다. 또한 희박연소화염에서 위치에 따른 NO 신호의 세기도 관측하였다.

  • PDF

메탄/공기 예혼합화염에서 CARS를 이용한 CO 농도 및 온도측정과 수치해석 결과의 비교 (Comparison of CARS CO and Temperature Measurements with Numerical Calculation for Methane/Air Premixed Flames)

  • 강경태;정석호;박승남
    • 대한기계학회논문집
    • /
    • 제19권5호
    • /
    • pp.1333-1339
    • /
    • 1995
  • Recently developed technique of measuring minor species concentration by using the modulation dip in broadband CARS has been applied to the flame structure study of methane/air premixed flames in a counterflow. This method used the modulation dip from the cold band CO Q-branch resonant signal superimposed on the nonresonant background. The measured CO concentration profile in a symmetric and unsymmetric methane/air premixed flames together with the velocity and temperature by using LDV and CARS have been compared with the numerical results adopting detailed chemistry modeling. The results show that there is a satisfactory agreement between the experimental data and numerical results for velocities, temperatures and CO concentrations. And the modulation dip technique of measuring minor species, such as CO is a viable tool for a quantitative measurement in a flame.

Standardized Protocols for Measuring Volatile Sulfur Compounds: Scientific Foundations and Methodologies

  • Ji-Youn Kim;Ji-Rak Kim;Jin-Seok Byun;Jae-Kwang Jung
    • Journal of Oral Medicine and Pain
    • /
    • 제49권1호
    • /
    • pp.5-11
    • /
    • 2024
  • Halitosis is defined as a nasty odor emanating through the mouth and is primarily related to the enhanced concentration of volatile sulfur compounds (VSCs). VSC measurements have been commonly used for experimental comparison and clinical diagnosis. As quantitative methods for comparative analyses of oral malodor, gas chromatography devices have been most commonly used to quickly and easily determine the concentration of several gas components of VSCs, which are agents primarily responsible for halitosis. The concentrations of VSCs fluctuate dynamically depending on contributing factors, including various oral/systemic conditions, intake of medicine and food/drink, oral hygiene, and even routine daily activities. Therefore, the exact analysis of VSCs requires the appropriate standardization of not only exact measurement techniques but also participant conditioning with scientific considerations. Thus, this paper describes the experimental standardizations commonly recommended in previous literature and their scientific background.

환경 방사능 처리기술에서의 Compton suppression 및 Unsuppression system을 이용한 토양시료의 MDA 측정 (Measurement of MDA of Soil Samples Using Unsuppression System and Compton Suppression of Environmental Radioactivity in Processing Technology)

  • 강수만;임인철;이재승;장은성;이미현;권경태;김창태
    • 한국방사선학회논문지
    • /
    • 제8권6호
    • /
    • pp.293-299
    • /
    • 2014
  • Compton suppression 장치는 Compton 산란 반응을 이용하여, 스펙트럼의 Compton continuum 부분을 억제함으로써 Compton continuum 영역 내에서의 감마선 피크들의 분석을 보다 명확하게 할 수 있게 해주는 장치이다. 표층토양 시료에서 검출된 인공 방사능인 $^{137}Cs$과 자연 방사능인 $^{40}K$핵종의 방사능 농도 값들에 대한 방사능 계수치가 백그라운드를 상회하는 측정값이 발생되거나, 불필요한 방해피크나 비해석 대상 피크에 대하여 검출된 표준선원의 방사능 농도 값들의 실측치에 대한 background를 비억제 스펙트럼(Compton Unsuppression)과 억제 스펙트럼(Compton suppression)을 적용시켜 측정 에너지에 대한 교정을 알고자 점선원인 $^{137}Cs$을 거리별에 따라 측정하여, 몬테칼로 시뮬레이션과 비교 분석함으로서 효율적인 검출 능력을 얻고자 함이며, Compton 억제 인자를 보면 거리가 멀어짐에 따라 CSF 값이 클수록 더 많은 Compton suppression가 이루어졌음을 알 수 있고, $^{137}Cs$을 이용한 컴프턴 비억제 모드와 억제모드로 측정된 스펙트럼에서 컴프턴 연속에 의한 백그라운드가 감소함을 알 수 있었다.