• Title/Summary/Keyword: backfill pressure

Search Result 206, Processing Time 0.034 seconds

Effects of freezing and thawing on retaining wall with changes in groundwater level

  • Kim, Garam;Kim, Incheol;Yun, Tae Sup;Lee, Junhwan
    • Geomechanics and Engineering
    • /
    • v.24 no.6
    • /
    • pp.531-543
    • /
    • 2021
  • Freezing and thawing of pore water within backfill can affect the stability of retaining wall as the phase change of pore water causes changes in the mechanical characteristics of backfill material. In this study, the effects of freezing and thawing on the mechanical performance of retaining wall with granular backfill were investigated for various temperature and groundwater level (GWL) conditions. The thermal and mechanical finite element analyses were performed by assigning the coefficient of lateral earth pressure according to phase change of soil for at-rest, active and passive stress states. For the at-rest condition, the mobilized lateral stress and overturning moment changed markedly during freezing and thawing. Active-state displacements for the thawed condition were larger than for the unfrozen condition whereas the effect of freezing and thawing was small for the passive condition. GWL affected significantly the lateral force and overturning moment (Mo) acting on the wall during freezing and thawing, indicating that the reduction of safety margin and wall collapse due to freezing and thawing can occur in sudden, unexpected patterns. The beneficial effect of an insulation layer between the retaining wall and the backfill in reducing the heat conduction from the wall face was also investigated and presented.

Comparison of Construction Cost and External Stability of Railway Abutment wall with Friction Angle of Backfill Materials (뒷채움재의 내부마찰각 변화에 따른 철도교대의 안정성 및 공사비 비교)

  • Yoo, Chunghyun;Choi, Chanyong;Yang, Sangbeom;Park, Yonggul
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.3
    • /
    • pp.67-76
    • /
    • 2016
  • The railway bridge abutment subjected to the lateral earth pressure is a sensitive structure that is affected by backfill materials, installation methods, compaction, and drainage system and so on. The several design loads for the bridge abutment design consist of traffic loading on bridges and vertical & lateral force due to surcharge load at backfill. Especially, the lateral earth pressure of design load components is important and considered in the design of geotechnical engineering structure such as bridge abutment wall. The determination of cross section for abutment is finally determined with calculating external stability and member force of abutment wall structures. In this study, the abutment wall height is 12m and the optimal cross section of abutment wall has been determined that satisfies an external stability for abutment structure through friction angles of 35, 40, and 45 degrees of backfill materials. The external stability and member force of abutment wall with friction angle of backfill materials and were calculated and construction cost of each abutment wall structures was compared. It found that the construction cost was reduced from 2.2 to 8.4% with friction angle of backfill materials.

The Earth Pressure on the Effect of Surcharge Load at the Narrowly Backfilled Soil (좁은 공간 되메움 지반에서의 상재하 영향에 의한 토압)

  • 문창열;이종규
    • Geotechnical Engineering
    • /
    • v.13 no.6
    • /
    • pp.165-180
    • /
    • 1997
  • The structure such as underground external walls of buildings, conduit and box culvert supports the surcharge loads (point, strip and line loads) . The vertical and horizontal stresses in a soil mass depend on the backfill width and wall friction, etc. The investigations described in this paper is designed to identify the magnitude and the distributions of the lateral and vertical pressure which is occurred by the narrowly backfilled soil in an open cut by the surcharge loads. For these purposes, model tests were performed for various width of backfill in a model test box by considering the wall friction using carbon rods. The results of test were compared with the theories of Weissenbach and VS Army Code and also with the results of the numerical analysis using finite difference method which introduces Mohr-Coulomb failure hypothesis.

  • PDF

A Simplified Numerical Model for an Integral Abutment Bridge Considering the Restraining Effects Due to Backfill

  • Hong, Jung-Hee;Jung, Jae-Ho;You, Sung-Kun;Yoon, Soon-Jong
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.5
    • /
    • pp.759-767
    • /
    • 2003
  • This paper presents the simplified but more rational analysis method for the prediction of additional internal forces induced in integral abutment bridges. These internal forces depend upon the degree of restraint provided tc the deck by the backfill soil adjacent to the abutments and piles. In addition, effect of the relative flexural stiffness ratio among pile foundations, abutment, and superstructure on the structural behavior is also an important factor. The first part of the paper develops the stiffness matrices, written in terms of the soil stiffness, for the lateral and rotational restraints provided by the backfill soil adjacent to the abutment. The finite difference analysis is conducted and it is confirmed that the results are agreed well with the predictions obtained by the proposed method. The simplified spring model is used in the parametric study on the behavior of simple span and multi-span continuous integral abutment PSC beam bridges in which the abutment height and the flexural rigidity of piles are varied. These results are compared with those obtained by loading Rankine passive earth pressure according to the conventional method. From the results of parametric study, it was shown that the abutment height, the relative flexural rigidity of superstructure and piles, and the earth pressure induced by temperature change greatly affect the overall structural response of the bridge system. It may be possible to obtain more rational and economical designs for integral abutment bridges by the proposed method.

Field Measurements of Compaction-Induced Lateral Earth Pressure on a Reversed-T Type Retaining Wall (역 T형 옹벽에 뒤채움다짐으로 유발된 횡토압의 현장계측)

  • Jeong, Seong-Gyo;Lee, Man-Ryeol;Jeong, Jin-Gyo
    • Geotechnical Engineering
    • /
    • v.11 no.2
    • /
    • pp.5-18
    • /
    • 1995
  • A Compaction-induced lateral earth pressure was measured for a reversed-T type retaining wall of 4m high for three months. As a result of in-situ measurements, the lateral earth pressure fluctuated sharply with time after backfill, which was closely dependent upon the displacement of the retaining wall. The measured results showed big discrepancy with theoretical predictions made by existing theories, which are applicable to rigid wall. However, the in -situ data twas compared relatively well with those obtained by the finite element method. Analysis showed that the discrepancy may be caused by the displacement of the retaining wall during the compaction of the backfill.

  • PDF

The Study of Deformation Characteristics into Landfill and Underground Pipe using CLSM (유동성 채움재 타설로 굴착부를 충진한 매립관의 변형특성 연구)

  • Nam, Seunghyeok;Chae, Hwiyoung;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.9
    • /
    • pp.27-33
    • /
    • 2011
  • In the case of the existing method of underground pipe construction, the difficulty of the bedding compaction of pipe causes reducing the compaction efficiency and the stability of the underground facilities and conclusively damaging the structures. One of the methods to solve these problem is using the flowable fills as a backfill material. Therefore, in this study, numerical analysis of the underground pipe was performed in order to evaluate the behavior of pipe according to backfill mixtures. To estimate the deformation characteristic of the underground pipe, the displacement of the main part of the pipe, ground settlement and vertical earth pressures were measured in different backfill mixtures and maintaining the other conditions constantly. As a result of numerical analysis, using the flowable fills as the backfill material is better than using sand in reducing the ground settlement, the pipe deformation and the vertical earth pressure aspect.

Earth Pressures on Box Culvert Induced by Excavation Geometry (되채움(굴착)의 형상에 따라 매설박스에 유발되는 토압)

  • 정성교;윤치관
    • Geotechnical Engineering
    • /
    • v.12 no.5
    • /
    • pp.27-40
    • /
    • 1996
  • Box culvert has long since been used for various purposes , water and sewerage works, communication and electricity facilities, subway, railway, etc. In urban area, the construetion of box culvert generally consists of excavation-installation of the culvert-backfill. However, the existing design methods for earth pressure on the box culvert do not take into account the excavation(or backfill) geometry. ' A new method considering excavation geometry for earth pressure on box culvert is suggested here. The lateral earth pressures by the newly suggested method agree relatively with results of finite element analyses, but those of existing method are greatly overestimated. The vertical pressure on the top of the box culvert by the new method is similar to those of existing method and finite element analysis. However, the reactional pressure on the bottom of the box culvert depends largely upon the stiffness of the foundation soil. The reactional pressure by the new method agrees well with that of finite element analysis, only when the stiffness is low. From the finite element analysis it is shown that the lateral earth pressure on box culvert depends upon the excavated slope (G) and the net bottom distance (Bc).

  • PDF

A Study on Effect of Earth Pressure Reduction and the Silo Earth Pressure of the Retaining Wall by CLSM Backfill with Waste Foundry Sand (폐주물사를 이용한 유동성 채움재의 절토구간 옹벽 뒤채움시 사일로토압 및 토압경감효과 연구)

  • Cho, Jae-Yun;Lee, Kwan-Ho;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.4 no.2 s.12
    • /
    • pp.19-31
    • /
    • 2002
  • The recycling of waste foundry sand(WFS) and fly ash as by-products of industry is one of the urgent problem to deal with. For the recycling of these materials, CLSM(controlled low strength materials) concept was adopted. This research has been done for last three years. In this research, couple of selected waste foundry sand and fly ash were used as fine aggregate. Also, WFS modified by Proper chemical liquid was used for the comparison. The main focus is to evaluate the silo earth pressure and the reduction effect due to the use of CLSM instead of normal fine aggregate. Silo effect, which occurs at short distance between retaining wall and backfill, was not detected because the characterization of CLSM is highly different from that of normal aggregate. Therefore, the theory for earth pressure, like Rankine theory or Coulomb theory, should be carefully used for CLSM. The reduction of earth pressure for modified WFS is higher than the others. But, the final earth pressure is converged at very small value, even though the reduction effect depends on the curing time.

  • PDF

Numerical Analysis for Lateral Earth Pressure on Retaining Wall with Relieving Platform backfilled with Jumoonjin Sand (주문진 모래로 뒤채움한 선반식 옹벽의 수평토압에 관한 수치해석)

  • Moon, In-Jong;Kim, Byoung-Il;Yoo, Wan-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3916-3922
    • /
    • 2014
  • Generally, the retaining wall is becoming unstable as the height is higher. On the other hand, the retaining wall with the relieving platform is more stable and more economical than any other type of retaining wall, because the relieving platform the reduce the lateral earth pressure. In this study, numerical analyses were carried out for 15 cases varying with the type of retaining wall, length and location of the relieving platform and the backfill type. From the numerical analyses, the reduction of the lateral earth pressure was checked and the results of numerical analyses were compared with that of model tests and theoretical equations. As the results of this study, the lateral earth pressure of the retaining wall with the relieving platform is considerably less than that of cantilever wall. And the of magnitude of the lateral earth pressure is affected by the length and location of relieving platform and the backfill type.