• Title/Summary/Keyword: back contact

Search Result 367, Processing Time 0.029 seconds

A Scanning Electron Microscopic Study on the Effect of Nd:YAG Laser Irradiation on the Cervical Cementum (Nd:YAG 레이저조사가 치경부 백악질에 미치는 영향에 관한 주사전자현미경적 연구)

  • Choi, Bok;Lee, Jeong-Yeon;Shin, Keum-back
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.4
    • /
    • pp.415-425
    • /
    • 2000
  • In order to obtain the basic data concerning the optimal lasing conditions in using Nd:YAG laser as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum, the author selected 36 human teeth having no cervical abrasion and caries (; 12 anteriors, 12 premolars. 12 molars) extracted due to periodontal diseases, and divided them into 4 groups as Group I, II, III and IV (; each group of 3 anteriors, 3 premolars, 3 molars), and prepared a cementum specimen with thickness of $1.0mm{\pm}0.2mm$ sectioned longitudinally at the middle of mesio-distal thickness (; Group I) or horizontally at 1mm-2mm below the cemento-enamel junction (; Group II, III, IV) from each tooth of each group by low speed diamond wheel saw, and treated them with 0.5 M ethylene diamine tetraacetic acid (; EDTA, pH=7.4) for 2 minutes for elimination of remnants during tooth-sectioning. And the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (; wavelength 1064nm. pulse duration $120{\mu}sec$, fiber diameter $320{{\mu}m}$) to cementum surfaces in triplicates of one experiment under the following lasing conditions: 1. stationary mode of fiber in contact to cementum surfaces without air-spray (; Group I )/with air-spray (; Group II), 2. unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec without air-spray (; Group III)/with air-spray (; Group IV), 3. energy per pulse (mJ/pulse) [; energy density ($J/cm^{2}$)] in order of 1.0W/10Hz (100J/pulse); $124J/cm^{2}$, 0.5W/10Hz (50mJ/pulse); $62J/cm^{2}$, 0.4W/10Hz (40mJ/pulse); $50J/cm^{2}$, 0.3W/10Hz (30mJ/pulse); $37J/cm^{2}$, 4. exposure time of 1 second. And the author applied the platinum coating on surfaces of cementum specimens, and evaluated the characteristics of ultrastructural change on surfaces of cementum using the scanning electron microscopy. In general the ultrastructural loss of cervical cementum irradiated under the same lasing condition of laser energy density occurred least in specimens of Group IV. And especially, the ultrastructural loss of cervical cementum irradiated under the laser energy density of $37J/cm^{2}$ almost did not occur in specimens of Group IV. Therefore, it is considered that the pulsed Nd:YAG laser should be applied with the lasing conditions of unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec with air-spray and of laser energy density within $37J/cm^{2}$ as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum.

  • PDF

Non-extraction treatment in Class III malocclusion by using improved superelastic NiTi wire (III급 부정교합 환자에서 초탄성 Ni-Ti alloy wire를 이용한 비발치 치료)

  • Min, Sam;Chung, Chu-Ryung;Hwang, Chung-Ju;Cha, Jung-Yul
    • The korean journal of orthodontics
    • /
    • v.41 no.4
    • /
    • pp.297-306
    • /
    • 2011
  • Nonextraction camouflage treatment in mild Class III malocclusion is achieved by backward movement of the lower dentition and forward movement of the upper dentition. Many camouflage treatment modalities have been used for distal tipping and distal movement of mandibular posterior teeth. The amount of distal movement of mandibular dentition can be improved in cases of severe crowding, even without the patient's cooperation, by using miniscrews for anchorage. However, miniscrew insertion may be unsuccessful, and it may contact the adjacent root because of the distal movement of dentition. Distal tipping of mandibular dentition can be achieved using multiloop edgewise archwires and intermaxillary elastics. However, the complexity of this wire design causes discomfort to patients. Recently, a new treatment using improved superelastic NiTi wires (ISWs) and intermaxillary elastics has been introduced. ISWs can deliver orthodontic force more effectively, and their use with molar tip-back treatment has several advantages-this approach is effective, simple, and easy to use and reduces patient discomfort. The aim of this study was to report a case of camouflage treatment using ISW with tip-back and intermaxillary elastics for distal tipping of mandibular posterior dentition and to evaluate the effectiveness of this treatment in a clinical setting.

Knowledge and Performance of Universal Precautions by Nursing Students (일부 간호대학생의 혈액매개질환 예방 지침에 대한 지식과 실천 정도)

  • 김경미;김민아;정여숙;김남초
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.4
    • /
    • pp.929-939
    • /
    • 1999
  • The purpose of this study was to identify knowledge of universal precautions and its performance in practice. The research was conducted from November 2 to 30, 1998. A total 515 student nurses ; 249 from a baccalaureate nursing college and 266 from second and third year of a 3-year community nursing college were surveyed. The results are as following : 1. The average score for universal precautions knowledge was 270.41$\pm$19.43/300(range 150-300). The results showed that 99.2% of students avoid injury from used needles, 98.6% answered that they always wash their hands if they had contact with the patient's blood and they always dispose of used needles in special collectors (97.7%) for needles. But, 39.2% responsed that they dispose of used needles after recapping them. 2. The average score for universal precautions knowledge of the senior students in the 4-year college was the highest (277.65$\pm$13.99). 3. The average score for the performance of universal precautions knowledge was 53.18 $\pm$5.91(range 14-70). The items : ‘I cautiously avoid injury from the used needles’(4.92$\pm$0.33), ‘I always wash my hands if there has been contact with the patient's blood’(4.91$\pm$0.34), and ‘I always disposed of used needles in the appropriate collector’(4.89$\pm$0.42) showed the highest performance. However ‘I always dispose of used needles after recapping them’(2.19$\pm$1.39) and ‘I always use protection goggles when in danger of contamination’(2.19$\pm$1.20) showed low performance level. 4. The highest average score for universal precautions performance was shown among the second year students in 3-year nursing college (54.19$\pm$6.92) between the groups. It showed that the level of the universal precautions performance was higher for those who had education on university precautions prior to performance of the universal precautions than for those without any prior education. 5. The percentage of students who reported the experience of direct contact with patients' blood and/or body fluids was 42.30%. The experience of direct contact with blood and/or body fluids of the educational group was significantly higher than those were not educated. 6. The most frequent cause of the direct contact was ‘needle pricking and/or skin cut’(63.04%). The most frequent substance with which the students contact was ‘blood’(59.85%). The majority of the sample had answered that the mode of contamination was ‘unknown’(63.54%). The majority of the sample answered that strategies used after contamination included ‘washing with soap’(33.61%). Reviewing the chart of patients or asking other health professionals(28.85%). 7. The number of students who had the experience of a needle stick and/or skin cut was 145(28.16%). The clinical practice places where the incidents occurred were mainly in the internal medicine unit (45.07%) and the surgical unit (31.92%) followed by the intensive care unit and the emergency unit in order. The experience of a needle stick and/or skin cut happened during on intra-muscular injection 47.34% and intravenous injection 21.81%. The causes of the needle stick and/or skin cut were ‘putting the needle cap back on 77(35.81%)’. The number of students who took an appropriate post management blood test and/or vaccination was 27(18.62%). 8. The Pearson Correlation Coefficient between the knowledge of universal precautions and performance of universal precautions in practice showed a positive correlation.

  • PDF

Development and Evaluation of Wearable Device with Heat and Massage Function (안마 및 발열기능의 스마트 조끼 개발과 성능 및 만족도 평가)

  • Roh, Eui Kyung;Yoon, Mi Kyung
    • Fashion & Textile Research Journal
    • /
    • v.22 no.5
    • /
    • pp.676-685
    • /
    • 2020
  • This study developed smart vests with heat and massage functions that changed patterns, designs, materials, etc., and evaluated their functions and satisfaction. A knitted fabric with good elasticity and a heating lining were used, and in consideration of this, the final vest pattern fitted to the upper body was completed. A heat pad was attached to the back, and 6 vibration motors were attached to the trapezius muscle. The controller was placed on the left chest for easy operation, and the battery was stored in an inner pocket under the controller. The heating effect of the smart vest, the location of the devices, and the ease of operation were excellent. When the massage function was operated, the thermal comfort was increased compared to when the massage function was not operated, and the high thermal comfort was perceived by the operation of heat and heat+massage function. Due to the battery, the weight, irritating contact of devices and wearing sensation decreased, but there was no reduction in wearing sensation due to heat and vibration devices. The greater the satisfaction with the massage function, thermal comfort, fit, appearance and weight, the greater the product satisfaction.

The Effect of Bumper Mismatch on Vehicle Repair Cost (차량 간 범퍼높이 차이가 수리비에 미치는 영향)

  • Choi, Dong-Won;Park, In-Song;Hong, Seung-Jun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.1
    • /
    • pp.99-104
    • /
    • 2010
  • It is a frequent occurrence in urban traffic - a low-speed collision in which one vehicle hits the back of another. The vehicles often sustain expensive damage. Bumpers can reduce this damage, but only line up so the initial contact in an impact is bumper to bumper. Then the bumpers on the colliding vehicles have to absorb the crash energy, keeping damage away from expensive sheet metal, lights, and other components. In real world accidents, Bumper mismatches in crashes are increasing, and the resulting repair costs from low-speed collisions are escalating. In this study, we investigated the bumper rail height and analyzed their effects on repair cost. Futhermore, Our 16kph front-into-rear crash tests demonstrates bumper mismatch problem.

Process and Performance Analysis of a-Si:H/c-Si Hetero-junction Solar Sells Prepared by Low Temperature Processes (저온 공정에 의한 a-Si:H/c-Si 이종접합 태양전지 제조 및 동작특성 분석)

  • Lim, Chung-Hyun;Lee, Jeong-Chul;Jeon, Sang-Won;Kim, Sang-Kyun;Kim, Seok-Ki;Kim, Dong-Seop;Yang-Sumi;Kang-Hee-Bok;Lee, Bo-young;Song-Jinsoo;Yoon-Kyung-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.196-200
    • /
    • 2005
  • In this work, we investigated simple Aㅣ/TCO/a-Si:H(n)/c-Si(p)/Al hetero-junction solar cells prepared by low temperature processes, unlike conventional thermal diffused c-Si solar cells. a-Si:H/c-Si hetero-junction solar cells are processed by low temperature deposition of n-type hydrogenated amorphous silicon (a-Si:H) films by plasma-enhanced chemical vapor deposition on textured and flat p-type silicon substrate. A detailed investigation was carried out to acquire optimization and compatibility of amorphous layer, TCO (ZnO:Al) layer depositions by changing the plasma process parameters. As front TCO and back contact, ZnO:Al and AI were deposited by rf magnetron sputtering and e-beam evaporation, respectively. The photovoltaic conversion efficiency under AMI.5 and the quantum efficiency on $1cm^2$ sample have been reported. An efficiency of $12.5\%$ is achieved on hetero-structure solar cells based on p-type crystalline silicon.

  • PDF

Measurements of Whole-body Vibration Exposed from UH60-Helicopter and Their Analysis Results (UH60 헬기 조종사의 피폭진동 측정 및 평가 결과)

  • Cheung, Wan-Sup;Byeon, Joo-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.132-137
    • /
    • 2005
  • This paper addresses what amount of whole-body vibration is exposed to pilots of UH60 helicopters during flight. To measure the whole-body exposed from the feet and seat, the 12-axis vibration measurement system was used. It enables simultaneous measurement of vibration exposure from the body contact area of the feet, hip and back. The measured 12-axis vibration signals are exploited to the comfort level of UH60 helicopters during flight. It is shown that the evaluated ride value is close to $0.74{\sim}0.79m/s^2$ and that it is equivalent to the semantic scale of 'fairly uncomfortable'. To assess the health effects of whole-body vibration exposed to pilots of UH60 helicopters during their flight, the rms-based and VDV(vibration dose value)-based evaluation results of measured four-axis vibration signals are shown in this work. The fatigue-decreased proficiency limit, whose level is half of the exposure limit, is expected to come after the two-hour flight. The exposure limit is shown to reach after the 10-hour flight.

  • PDF

Biomechanical Analysis of the Artificial Discs (인공디스크에 대한 생체역학적 분석)

  • Kim Young-Eun;Yun Sang-Seok;Jung Sang-Ki
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.907-910
    • /
    • 2005
  • Although several artificial disc designs have been developed for the treatment of discogenic low back pain, biomechanical change with its implantation was rarely studied. To evaluate the effect of artificial disc implantation on the biomechanics of functional spinal unit, nonlinear three-dimensional finite element model of L4-L5 was developed with 1-mm CT scan data. Two models implanted with artificial discs, SB $Charit\acute{e}$ or Prodisc, via anterior approach were also developed. The implanted model predictions were compared with that of intact model. Angular motion of vertebral body, force on spinal ligaments and facet joint, and the stress distribution of vertebral endplate for flexion-extension, lateral bending, and axial rotation with a compressive preload of 400 N were compared. The implanted model showed increased flexion-extension range of motion and increased force in the vertically oriented ligaments, such as ligamentum flavum, supraspinous ligament and interspinous ligament. The increase of facet contact force on extension were greater in implanted models. The incresed stress distribution on vertebral endplate for implanted cases indicated that additinal bone growth around vertebral body and this is matched well with clinical observation. With axial rotation moment, relatively less axial rotation were observed in SB $Charit\acute{e}$ model than in ProDisc model.

  • PDF

The Secondary Island Flap Using Omental Vascular Carrier in Rats (백서의 대망을 혈관경으로 이식하여 생성시킨 이차적 도서형 피판)

  • Lew, Dae-Hyun;Tark, Kwan-Chul;Lew, Jae-Duk
    • Archives of Reconstructive Microsurgery
    • /
    • v.5 no.1
    • /
    • pp.16-23
    • /
    • 1996
  • The omental pedicle based on right gastroepiploic vessels is designed new experimental model for prefabrication(revasculirization) of skin flaps in rats. A $2.5{\times}4cm$ pack of omentum with right gastroepiploic vessels was transferred under a bipediceld panniculocutaneous flap which is $2.5{\times}8cm$ size. At day 7, all four margin was divided and the flap was rasied as an secondary island flap connected only by its vascular pedicle, then the composite flap sutured back in place. The flap perfusion was examined by dermofluorometry and flap survival area was measured at day 12. The Secondary island flap demonstrated a dye fluorescence index(DFI%) of $31.38{\pm}12.33$ and survival rate $80.47{\pm}9.61$ The survival rate was increased when DFI% and contact surface between vascular carrier and skin flap was increased. An india ink injection and histologic examination provided visual evidence of revasculization. The omental pedicle is a promising and safe model for revasculirization of other tissues.

  • PDF

Development of Clamping Force Estimation Algorithm and Clamp-force Sensor Calibration on Electromechanical Brake Systems (전동식 브레이크 시스템의 클램핑력 센서 교정 및 클램핑력 추정 알고리즘 개발)

  • Park, Giseo;Choi, Seibum;Hyun, Dongyoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.3
    • /
    • pp.365-371
    • /
    • 2016
  • The electromechanical brake (EMB) is one of future brake systems due to its many advantages. For implementation of the EMB, the correct feed back about clamping force is necessary. Keeping commercialization of the EMB in mind, it is strongly demanded that an expensive load cell measuring the clamping force is replaced with an estimation algorithm. In addition, an estimation of the kissing point where the brake pads start to come into contact with a disk wheel is proposed in this paper. With these estimation algorithms, the clamping force can be expressed as a polynomial characteristic curve versus the motor angle. Also, a method for calibration of measured values by the load cell is proposed and used for an actual characteristic curve. Lastly, the performance of the proposed algorithms is evaluated in comparison with the actual curve on a developed EMB test bench.