• Title/Summary/Keyword: axis alignment

Search Result 234, Processing Time 0.025 seconds

Verification of Periodical Calibration for Iso-center Positions using Quality Assurance System for Irradiation Equipment Position Established at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.192-194
    • /
    • 2002
  • We present the results on the calibration of iso-center positions using the quality assurance system established at PMRC for determination of center position in X-ray and proton irradiation fields. Details on the system are presented in another presentation in this session. The equipment in the system is mounted on a patient treatment bed in each proton exposure room, G1 or G2. A center of a stainless ball on the equipment is set at a cross of laser markers located around the iso-center and fixed on the room and on the snout in the gantry. A proton beam or an X-ray beam is exposed onto the ball through a brass collimator of 100 mm ${\times}$ 100 mm and projected onto the imaging plate set at I cm behind the ball. On the axis perpendicular to the thrust axis of the gantry on the imaging plate, a distance between a center of the collimator image and a center of the ball image varies as a cosine function of gantry angles unless the ball is set on the iso-center. An amplitude of the cosine curve shows the distance between the ball and the iso-center, an offset the offset of the collimator, and a phase shift at a zero crossing point the ball direction viewed from the iso-center. We present the relation among the iso-center position, the laser maker position, and the center of proton and X-ray irradiation fields. Its stability and its reproducibility are discussed.

  • PDF

Treatment Planning and Dosimetry of Small Radiation Fields for Stereotactic Radiosurgery (Stereotactic Radiosurgery를 위한 소형 조사면의 선량측정)

  • Chu Sung Sil;Suh Chang Ok;Loh John J.K.;Chung Sang Sup
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.101-112
    • /
    • 1989
  • The treatment planning and dosimetry of small fields for stereotactic radiosurgery with 10 MV x-ray isocentrically mounted linear accelerator is presented. Special consideration in this study was given to the variation of absorbed dose with field size, the central axis percent depth doses and the combined moving beam dose distribution. The collimator scatter correction factors of small fields $(1\times1\~3\times3cm^2)$ were measured with ion chamber at a target chamber distance of 300cm where the projected fields were larger than the polystyrene buildup caps and it was calibrated with the tissue equivalent solid state detectors of small size (TLD, PLD, ESR and semiconductors). The central axis percent depth doses for $1\timesl\;and\;3\times3cm^2$ fields could be derived with the same acuracy by interpolating between measured values for larger fields and calculated zero area data, and it was also calibrated with semiconductor detectors. The agreement between experimental and calculated data was found to be under $2\%$ within the fields. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor regions was performed with dose planning computer system (Therac 2300) and was verified with film dosimetry. The more the number of strips and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. The circular cone, we designed, improves the alignment, minimizes the penumbra of the beam and formats ball shape of treatment area without stellate patterns. These dosimetric techniques can provide adequate physics background for stereotactic radiosurgery with small radiation fields and 10MV x-ray beam.

  • PDF

로켓 모션테이블 실시간 모의시험

  • Sun, Byung-Chan;Park, Yong-Kyu;Choi, Hyung-Don;Cho, Gwang-Rae
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.170-178
    • /
    • 2004
  • This paper deals with six degree-of-freedom HILS(hardware-in-the-loop-simulation) of KSR-III rocket using a TAFMS(three axis flight motion simulator). This TAFMS HILS test is accomplished before main HILS tests in order to verify the control stability in the presence of TAFMS dynamic effects. The TAFMS HILS test includes initial attitude holding tests for INS initial alignment procedures, timer synchronization tests with an auxiliary lift-off signal, real-time calibration tests using an external thermal recorder, open-loop TAFMS operating tests, and final closed-loop TAFMS HILS tests using the TAFMS attitude measurements as inputs to the closed control loop. The HILS tests are accomplished for several flight conditions composed with nominal flight condition, TWD effect added condition, slosh modes and/or bending modes existing condition, and windy condition, etc.

  • PDF

Polarization Analysis of Composite Optical Films for Viewing Angle Improvement of Liquid Crystal Display (액정 디스플레이 시야각 향상을 위한 복합판의 편광특성 분석)

  • Ryu, Jang-Wi;Kim, Sang-Youl;Kim, Yong-Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.4
    • /
    • pp.241-248
    • /
    • 2009
  • We suggest a new method to determine the off-alignment error of the composite film, together with in-plane($R_{in}$) and out-of-plane retardation($R_{th}$) of the compensation film, simultaneously. The composite film consists of a polarizing film and a compensation film for improvement of viewing angle of a liquid crystal display. We regarded the compensation film as o-plate with its optic axis along an arbitrary direction. By using an extended Jones matrix method, the polarization characteristics of the composite film are examined. The calculated Fourier constants, ($\alpha$, $\beta$) curves of the composite film as the azimuth angle is varied at the incident angles of $0^{\circ}$ and $50^{\circ}$, respectively, are used to determine the axis misalignment, the tilt angle and the azimuth angle of the compensation film by adopting the linear regressional analysis technique. Since this method can be applied for the inspection of the composite film even after laminating the polarizing film and the compensation film, it will be useful for simplifying the manufacturing process and reducing the production cost of liquid crystal display panels.

Brief Summary of KSLV-I Upper Stage Kick Motor Development (KSLV-I 상단 킥모터 개발 개요)

  • Lee, Hanju;Lee, Jung Ho;Oh, Seung Hyub
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.1
    • /
    • pp.91-96
    • /
    • 2014
  • KSLV-I (Korea Space Launch Vehicle-I) upper stage KM (Kick Motor) is a solid propulsion system which consists of igniter, SAD (Safety Arming Device), composite case, and submerged nozzle capable of TVC (Thrust Vector Control) actuation. Each subsystem of KM fulfilled development requirements for achieving a flight mission successfully. We confirmed the successful development of KM from the $3^{rd}$ flight test results of NARO on January 30, 2013. This article deals with the requirements of KM and the results on configuration management, mass variation, thrust axis alignment, and major test results and so on.

Determination of Total Knee Replacement Parameter by Simulation (시뮬레이션을 이용한 슬관절 수술 변수 결정)

  • Yoon Y.S.;Park S.H.;Lee S.H.;Choi K.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.881-887
    • /
    • 2005
  • A total knee replacement is an extremely 'position-sensitive' operation; a malposition or a malalignment of the components will lead to a breakage of the component, a fracture around the knee prosthesis, and the limitation of range of the motion, etc. In a conventional total knee replacement, surgeons have to select an appropriate prosthesis according to the shape of the surgical region. A wrong selection may give rise to side effects or to need re-operation. Nevertheless, it is so difficult to choose the most proper prosthesis out of various kinds of prosthesis. This paper presents a surgical planning system for the total knee replacement with an operation simulating method in order to determine the parameters for the total knee replacement operation. We select an alignment axis and a resection angle as major operation parameters in the total knee replacement operation, and introduce the method to determine the major operation parameters with the operation simulator we developed. The simulator is used to determine operation parameters for optimized operations, to select the most appropriate prosthesis, and to analyze the prospective problems of the operation.

  • PDF

Polarization Converting Waveguide Devices Incorporating UV-curable Reactive Mesogen

  • Chu, Woo-Sung;Kim, Sung-Moon;Kim, Jun-Whee;Kim, Kyung-Jo;Oh, Min-Cheol
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.289-292
    • /
    • 2011
  • Reactive mesogen (RM) is an organic liquid crystal molecule that can be self-aligned to have an optic axis of birefringence when coated over a polyimide alignment film. A free-standing optical wave-plate film consisting of RM and low-loss optical polymers was fabricated in this work, and the film was inserted across the polymer waveguide to form an integrated optical polarization converter. For convenient evaluation of the polarization converters, a waveguide polarizer and analyzer were fabricated in series. The polarization conversion efficiency was measured to be 25 dB for the wavelength range from 1520 to 1580 nm. The wave plate exhibited a temperature-dependent retardation of $4.5^{\circ}$ for a temperature change from 25 to $100^{\circ}C$.

Tolerance Analysis and Compensation Method Using Zernike Polynomial Coefficients of Omni-directional and Fisheye Varifocal Lens

  • Kim, Jin Woo;Ryu, Jae Myung;Kim, Young-Joo
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.720-731
    • /
    • 2014
  • There are many kinds of optical systems to widen a field of view. Fisheye lenses with view angles of 180 degrees and omni-directional systems with the view angles of 360 degrees are recognized as proper systems to widen a field of view. In this study, we proposed a new optical system to overcome drawbacks of conventional omni-directional systems such as a limited field of view in the central area and difficulties in manufacturing. Thus we can eliminate the undesirable reflection components of the omni-directional system and solve the primary drawback of the conventional system. Finally, tolerance analysis using Zernike polynomial coefficients was performed to confirm the productivity of the new optical system. Furthermore, we established a method of optical axis alignment and compensation schemes for the proposed optical system as a result of tolerance analysis. In a sensitivity calculation, we investigated performance degradation due to manufacturing error using Code V(R) macro function. Consequently, we suggested compensation schemes using a lens group decentering. This paper gives a good guidance for the optical design and tolerance analysis including the compensation method in the extremely wide angle system.

Mechanical Properties of C-type Mesophase Pitch-based Carbon Fibers

  • Ryu, Seung-Kon;Rhee, Bo-Sung;Yang, Xiao Ping;Lu, Yafei
    • Carbon letters
    • /
    • v.1 no.3_4
    • /
    • pp.165-169
    • /
    • 2001
  • The C-type mesophase pitch-based carbon fiber (C-MPCF) was prepared throuch C-type spinnerette and compared the mechanical properties to those of round type mesophase pitch fiber (R-MPCF) and C-type isotropic pitch fiber (C-iPCF). The tensile strength and modulus of C-MPCF were about 18.6% and 35.7% higher than those of R-MPCF. The tensile strength of C-MPCF was 62% higher than that of C-iPCF of the same $8{\mu}m$ thickness because of more linear transverse texture, which could be easily converted to graphitic crystallinity during heat treatment. The torsional rigidity of C-MPCF was 2.37 times higher than that of R-MPCF. The electrical resistivity of C-MPCF was $8{\mu}{\Omega}{\cdot}m$. The C-iPCF shows far lower electrical resistivity than R-iPCF as well as the mesophase carbon fiber because of better alignment of texture to the fiber axis.

  • PDF

Study on PVA mode using the UV curable reactive mesogen (RM) (광경화성 단분자를 이용한 PVA모드의 8-도메인 형성방안 연구)

  • Kim, Woo-Il;Kim, Sung-Min;Cho, In-Young;Kim, Mi-Young;Son, Jong-Ho;Ryu, Jae-Jin;Kim, Kyeong-Hyeon;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.339-340
    • /
    • 2008
  • The Conventional PVA (patterned vertical alignment) mode showed characteristics of 8-domain using T-T type or C-C type. But these methods have disadvantages such as decreasing aspect ratio and transmittance. In order to resolve these problems, in this paper we have studied a new 8-domain method which is partially using the UV curable reactive mesogen (RM) that is a role in surface stabilization. The characteristic of off-axis color shift is decreased because the part of surface stabilized area is compensated to other area in a pixel. Consequently, the device shows improved color shift by 8-domain.

  • PDF