• Title/Summary/Keyword: axial force effect

Search Result 386, Processing Time 0.03 seconds

Effect of the height of SCSW on the optimal position of the stiffening beam considering axial force effect

  • Azar, B. Farahmand;Hadidi, A.;Khosravi, H.
    • Structural Engineering and Mechanics
    • /
    • v.41 no.2
    • /
    • pp.299-312
    • /
    • 2012
  • Stiffened coupled shear walls (SCSW) are under axial load resulting from their weight and this axial load affects the behavior of walls because of their excessive height. In this paper, based on the continuum approach, the optimal position of the stiffening beam on the stiffened coupled shear walls is investigated considering the effect of uniformly distributed axial loads. Moreover, the effect of the height of stiffened coupled shear walls on the optimal position of the stiffening beam has been studied with and without considering the axial force effect. A computer program has been developed in MATLAB and numerical examples have been solved to demonstrate the reliability of this method. The effects of the various flexural rigidities of the stiffening beam on the internal forces and the lateral deflection of the structure considering axial force effect have also been investigated.

Effect of Axial Force on Shear Behavior in Reinforced Concrete Beams (RC 부재의 전단거동에 미치는 축력의 영향에 대한 연구)

  • Jeong Jae Pyong;Kim Dae Joong;Yum Hwan Seok;Kim Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.264-267
    • /
    • 2004
  • It is well known that axial tension decreases the shear strength of RC beams without transverse reinforcement, and axial compression increases the shear resistance. What is perhaps not very well understood is how much the shear capacity is influenced by axial load. RC beams without shear reinforcement subjected to large axial compression and shear may fail in a very brittle manner at the instance of first diagonal cracking. As a result, a conservative approach should be used for such members. According to the ACI Code, the concrete contribution is calculated by effect of axial force and the vertical force in the stirrups calculated by $45^{\circ}$ truss model. This study was performed to examine the effect of axial force in reinforced concrete beams.

  • PDF

Soil-structure interaction and axial force effect in structural vibration

  • Gao, H.;Kwok, K.C.S.;Samali, B.
    • Structural Engineering and Mechanics
    • /
    • v.5 no.1
    • /
    • pp.1-19
    • /
    • 1997
  • A numerical procedure for dynamic analysis of structures including lateral-torsional coupling, axial force effect and soil-structure interaction is presented in this study. A simple soil-structure system model has been designed for microcomputer applications capable of reflecting both kinematic and inertial soil-foundation interaction as well as the effect of this interaction on the superstructure response. A parametric study focusing on inertial soil-structure interaction is carried out through a simplified nine-degree of freedom building model with different foundation conditions. The inertial soil-structure interaction and axial force effects on a 20-storey building excited by an Australian earthquake is analysed through its top floor displacement time history and envelope values of structural maximum displacement and shear force.

Vehicle Shudder Associated with Axial Thrust Force of C.V.Joint For Automobile (자동차용 등속조인트의 AXIAL FORCE와 VEHICLE SHUDDER(I))

  • 오승탁
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.2
    • /
    • pp.198-208
    • /
    • 1996
  • The plunge joints of C.V. Joint for vehicle tend to produce a cyclic axial disturbance at a frequency of three of six times shaft speed, in which this distrubance caused by internal frictional effect is related to joint angle, rotational speed, torque, and joint size. This principal axial thrust force might make vehicle shuddered when coinciding with vehicle frequency of tranverse direction, and be one of reasons to have driver feel uncomfortable, unesay, while driving vehicle. The paper makes analysis of axial thrust force & vehicle shudder through computer simulation, comparing the result with experimental data, and reviewing the effect by changing of variables such as dimensions and driving conditions.

  • PDF

Inelastic seismic analysis of RC bridge piers including flexure-shear-axial interaction

  • Lee, Do Hyung;Elnashai, Amr S.
    • Structural Engineering and Mechanics
    • /
    • v.13 no.3
    • /
    • pp.241-260
    • /
    • 2002
  • The effect of shear coupled with axial force variation on the inelastic seismic behaviour of reinforced concrete bridge piers is investigated in this paper. For this purpose, a hysteretic axial-shear interaction model was developed and implemented in a nonlinear finite element analysis program. Thus, flexure-shear-axial interaction is simulated under variable amplitude reversed actions. Comparative studies for shear-dominated reinforced concrete columns indicated that a conventional FE model based on flexure-axial interaction only gave wholly inadequate results and was therefore incapable of predicting the behaviour of such members. Analysis of a reinforced concrete bridge damaged during the Northridge (California 1994) earthquake demonstrated the importance of shear modelling. The contribution of shear deformation to total displacement was considerable, leading to increased ductility demand. Moreover, the effect of shear with axial force variation can significantly affect strength, stiffness and energy dissipation capacity of reinforced concrete members. It is concluded that flexure-shear-axial interaction should be taken into account in assessing the behaviour of reinforced concrete bridge columns, especially in the presence of high vertical ground motion.

Characteristics of axial vibration of marine diesel engine crankshafts (박용디이젤기관의 크랭크축계 종진동특성에 관한 연구)

  • 전효중;왕지석;김의간
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.22-28
    • /
    • 1983
  • In former papers which were published already, authors had derived calculation formulae for the axial stiffness and the radial force conversion factor of crankshaft. In this paper, crankthrow axial stiffness and radial force conversion factors of actual engines are calculated by these theoretical formulae and then their characteristics are investigated. As the results, the axial stiffness and the radial force conversion factor of the latest super-long stroke engine are smaller than those of old-type engines. The influence of the former brings down the resonance speed of engine and the latter reduces the exciting force of axial vibration, but as the harmonic component of axial vibration force becomes rather strong, its effect of reducing is considerably canceled. In conclusion, as the latest super-long stroke engine is seemed to be liable to axial vibration of crankshafat, it is recommend that, in the design stage of propulsion shaft, its axial vibration condition must be more carefully checked.

  • PDF

Shear Strength Prediction of Reinforced Concrete Members Subjected In Axial force using Transformation Angle Truss Model (변환각 트러스 모델에 의한 축력을 받는 철근콘크리트 부재의 전단강도 예측)

  • Kim Sang-Woo;Lee Jung-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.6 s.84
    • /
    • pp.813-822
    • /
    • 2004
  • For the prediction of the shear strength of reinforced concrete members subjected to axial force, this paper presents a truss model, Transformation Angle Truss Model (TATM), that can predict the shear behavior of reinforced concrete members subjected to combined actions of shear, axial force, and bending moment. In TATM, as axial compressive stress increases, crack angle decreases and concrete contribution due to the shear resistance of concrete along the crack direction increases in order to consider the effect of the axial force. To verify if the prediction results of TATM have an accuracy and reliability for the shear strength of reinforced concrete members subjected to axial forces, the shear test results of a total of 67 RC members subjected to axial force reported in the technical literatures were collected and compared with TATM and existing analytical models(MCFT RA-STM and FA-STM). As a result of comparing with experimental and theoretical results, the test results was better predicted by TATM with 0.94 in average value of $\tau_{test}/\tau_{ana}$. and $11.2\%$ in coefficient of variation than other truss models. And theoretical results obtained from TATM were not effect by steel capacity ratio, axial force, shear span-to-depth ratio, and compressive steel ratio.

Analytic Study on the Axial Forces of a Double Offset Constant Velocity Joints in Consideration of Friction Effect (마찰을 고려한 이중 오프셋 등속조인트의 축력 해석에 관한 연구)

  • Bae, Byoung-Chul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.120-127
    • /
    • 2008
  • The constant velocity joint(CVJ) used for transmitting torque to the front wheels is an important part in automotive drive system. There are several types of constant velocity joints. Typically, they are classified by fixed and plunging constant velocity joints. The axial force generated in plunging constant velocity joints influences significantly the noise, vibration and harshness. For heaps of time, many constant velocity joint markers have been studying and developing a valid method to reduce the axial force and extensive tests have been carried out on rigs. This paper presents the analysis method to predict the axial force of a double offset constant velocity joint(DOJ), a kind of plunging constant velocity joint, and the influence of ball-cage dimension tolerance on the axial force.

Shear Deformation based on the Biaxial Tension-Compression Theory in Prestressed Concrete Members applied by Axial Loading (이축인장압축장이론에 기반한 PSC보의 전단변형)

  • Jeong, Jae-Pyong;Kim, Dae-Joong;Mo, Gui-Suk;Kim, Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.281-284
    • /
    • 2006
  • ASCE-ACI Committee 426 and 445, on Shear and Torsion, well noted in their report that recent research work regarding shear and torsion had been devoted primarily to members. But it was not logical approach of PSC members applied by axial force based on the shear deformation in web element. And it was not included that the effect of axial is to shift the shear strain(or crack width) in the web element versus the applied shear curve up or down by the amount by which the biaxial tension-compression state varies. The shear strength also increases or decreases, so that the change in shear strain at service load due to the presence of axial load is to some extent changed. Generally, in corresponding beams the shear strain at service load is less in the beam subject to axial compression and greater in the beam subject to axial tension, than in the beam without axial load. In particular, however, no research were available on the shear deformation in shear of PSC members with web reinforcement, subject to axial force in addition to shear and bending. Therefore, this study was basically performed to develop the program for the calculation of the shear deformation based on the shear effect of axial force in prestressed concrete members.

  • PDF

Influence of the axial force on the behavior of endplate moment connections

  • Ghassemieh, Mehdi;Shamim, Iman;Gholampour, Ali Akbar
    • Structural Engineering and Mechanics
    • /
    • v.49 no.1
    • /
    • pp.23-40
    • /
    • 2014
  • In this article, using finite element method of analysis (FEM), behavior of the endplate moment connection subjected to axial force and bending moment is investigated. In the FEM model, all the nonlinear characteristics such as material, geometry, as well as contact have been included. First, in order to verify the numerical model of the connection, an analysis of the endplate moment connection conducted without the application of the axial force. Results obtained from FEM indicating a close and good correlation with the experimental results. Then to investigate the influence of the axial forces, the connections subjected to axial forces as well as the bending moment are analyzed. To observe the overall effect of these actions, the momentaxial force interaction diagrams are drawn. It is observed that the presence of axial force even in a small value can change the behavior of the connection significantly. It is also shown that the axial forces can alter the failure mode of the connection; and therefore it could result in a different than the predicted moment capacity of the connection.