• 제목/요약/키워드: average sampling interval

검색결과 76건 처리시간 0.025초

도로 유형별 비점오염원의 수질특성 (Water Quality Characteristics of Nonpoint Pollutants based on the Road Type)

  • 장대창;강선홍
    • 상하수도학회지
    • /
    • 제23권5호
    • /
    • pp.631-636
    • /
    • 2009
  • This study has its intention to investigate the water quality of non-point source which is runoff from roads. We have classified and selected twelve sites as city road, industrial road, national road and mountain road by considering their traffic volume and surroundings. Water quality was analyzed based on BOD, COD, SS, T-N and T-P and the concentrations were measured by sampling after rainfall with the interval of 10 minutes, 20 minutes, and 30 minutes. BOD was the highest in city road with 57.6 mg/L and the lowest in mountain road with 45.0 mg/L. For COD, the highest concentration in industrial road was 146.5 mg/L and the lowest was in mountain road with 98.0 mg/L. The run off concentration of SS was up to maximum 630.0 mg/L (average 280.4 mg/L) which was remarkable compared to other types of road. It showed its lowest concentration in national road with 76.0 mg/L. T-N and T-P were the highest in industrial road and the lowest in mountain road. We found out that the runoff concentration was high with large amount of traffic volume and it seemed to be high in city road and industrial road where they were largely affected by their surroundings. Relatively, national road and mountain road seemed to show low concentration as they have less traffic volume and less affected by their surroundings.

Characteristics of Non-Point Pollution from Road Surface Runoff

  • Lee, Chun-Sik;Jang, Seong-Ho
    • 한국환경과학회지
    • /
    • 제19권6호
    • /
    • pp.665-670
    • /
    • 2010
  • Pollutants from urban pavement consists various kinds of substances which are originated from dry deposition, a grind out tire, corrosive action of rain to pavement and facilities and raw materials of the road etc.. These are major pollutants of urban NPS (Non-point source) during rainfall period. However there is not enough information to control such pollutants for appropriate management of natural water quality. In this study of transportation areas, three monitoring stations were set up at trunk road, urban highway and national road in Gyeongnam province. Runoff flow rate was measured at every 15minutes by automatic flow meters installed at the end of storm sewer pipe within the road catchment area for water quality analysis. Data was collected every 15 minutes for initial two hours of rainfall. Additional samples were collected 1-4 hours interval till the end of rainfall. The monitoring parameters were $COD_{Mn}$, SS, T-N & T-P and heavy metals. The average EMCs of TSS and $COD_{Mn}$ were 62.0 mg/L and 24.2 mg/L on the city trunk road, which were higher than those of urban highway and national road, indicating higher pollutant loads due to activities in the city downtown area beside the vehicle. On the other hand, the average EMC of T-N and T-P were in the range of 2.67-3.23 mg/L and 0.19-3.21 mg/L for all the sampling sites. Heavy metals from the roads were mainly Fe, Zn, Cu and Mn, showing variable EMCs by the type of road. From the TSS wash-off analysis in terms of FF(first flush) index, first flush phenomenon was clearly observed in the trunk road(FF : 0.89-1.43). However, such mass delivery behavior was not apparently shown in urban highway(FF : 0.90-1.11) and national road(FF : 0.81-1.41).

데이터 기반 모델에 의한 온실 내 기온 변화 예측 (Data-Based Model Approach to Predict Internal Air Temperature of Greenhouse)

  • 홍세운;문애경;리송;이인복
    • 한국농공학회논문집
    • /
    • 제57권3호
    • /
    • pp.9-19
    • /
    • 2015
  • Internal air temperature of greenhouse is an important variable that can be influenced by the complex interaction between outside weather and greenhouse inside climate. This paper focuses on a data-based model approach to predict internal air temperature of the greenhouse. External air temperature, solar radiation, wind speed and wind direction were measured next to an experimental greenhouse supported by the Electronics and Telecommunications Research Institute and used as input variables for the model. Internal air temperature was measured at the center of three sections of the greenhouse and used as an output variable. The proposed model consisted of a transfer function including the four input variables and tested the prediction accuracy according to the sampling interval of the input variables, the orders of model polynomials and the time delay variable. As a result, a second-order model was suitable to predict the internal air temperature having the predictable time of 20-30 minutes and average errors of less than ${\pm}1K$. Afterwards mechanistic interpretation was conducted based on the energy balance equation, and it was found that the resulting model was considered physically acceptable and satisfied the physical reality of the heat transfer phenomena in a greenhouse. The proposed data-based model approach is applicable to any input variables and is expected to be useful for predicting complex greenhouse microclimate involving environmental control systems.

개회로 CO2/H2O 적외선 기체 분석기 보정 인자의 변동성과 장기 플럭스 관측에 미치는 영향 (Variability of Calibration Factors for Open-Path CO2/H2O Infrared Gas Analyzer and Its Effect on Long-Term Flux Measurement)

  • 최태진;윤진일;임종환;박은우;김준
    • 한국농림기상학회지
    • /
    • 제4권2호
    • /
    • pp.103-113
    • /
    • 2002
  • Calibration experiments were executed to document pertinent calibration methods for open-path infrared gas analyzer (OP-2) in field operations and to quantify their performance characteristics in continuous long-term flux measurements. Based on our results, we concluded: (1) flow rate of 2.0 L min$^{-1}$ can be used for calibration instead of the recommended 0.5 L min$^{-1}$ . Such faster flow rate brings the sampled air in the calibration hood at equilibrium within 5 min for $CO_2$ and 10 min for $H_2O$; (2) after reaching equilibrium, two-minute average sampling for related variables per each concentration may be sufficient; (3) use of four concentration is needed to derive the nonlinear calibration equation for water vapor with 1% uncertainty of flux measurement; and (4) the resultant calibration interval for OP-2 for both $CO_2$ and $H_2O$ is approximately one month.

산림 사면에서 토양수분 실측 자료, 평형증발 및 에디-공분산방법을 이용한 토양증발비교 (Comparison of Soil Evaporation Using Equilibrium Evaporation, Eddy-Covariance and Surface Soil Moisture on the Forest Hillslope)

  • 곽용석;김상현;김수진
    • 한국환경과학회지
    • /
    • 제22권1호
    • /
    • pp.119-129
    • /
    • 2013
  • We compared equilibrium evaporation($E_{equili}$) eddy-covariance($E_{eddy}$) with soil moisture data($E_{SMseries}$) which were measured with a 2 hours sampling interval at three points for a humid forest hillslope from May 5th to May 31th in 2009. Accumulations of $E_{eddy}$, $E_{equili}$ for the study period were estimated as 2.52, 3.28 mm and those of $E_{SMseries}$ were ranged from 1.91 to 2.88 mm. It suggested that the eddy-covariance method considering the spatial heterogeneity of soil evaporation is useful to evaluate the soil evaporation. Method A, B and C were proposed using mean meterological data and daily moisture variation and the computations were compared to eddy-covariance method and equilibrium evaporation. The methods using soil moisture data can describe the variations of soil evaporation from eddy-covariance through simple moving average analysis. Method B showed a good matched with eddy-covariance method. This indicated that Dry Surface Layer (DSL) at 14:00 which was used for method B is important variable for the evaluation of soil evaporation. The total equilibrium evaporation was not significantly different to those of the others. However, equilibrium evaporation showed a problem in estimating soil evaporation because the temporal tendency of $E_{equili}$ was not related with the those of the other methods. The improved understanding of the soil evaporation presented in this study will contribute to the understandings of water cycles in a forest hillslope.

전기장 왜란을 이용한 비접촉 스마트 TV 제스처 인식 알고리즘 (Non-Contact Gesture Recognition Algorithm for Smart TV Using Electric Field Disturbance)

  • 조정재;김영철
    • 한국멀티미디어학회논문지
    • /
    • 제17권2호
    • /
    • pp.124-131
    • /
    • 2014
  • 본 논문에서는 4-채널 전위계 센서의 배열을 이용한 비접촉 제스처 인식 알고리즘을 제안한다. 주변의 전기장 변화에 민감한 전위계 센서를 스마트기기의 제스처인식에 활용하기 위해서 실내 환경에서 극저주파 대역 EMI(Electro Magnetic Interference) 및 PLN(Power Line Noise) 영향을 최소화하였다. AC 형태의 입력 데이터 값에 10Hz LPF(Low Pass Filter) 및 H/W 샘플링 속도를 고려한 최대 버퍼 값 추출 알고리즘을 적용하여 선형적인 DC 형태의 데이터로 변형한다. 추가적으로 칼만 필터를 적용함으로써 노이즈를 최소화하며, 센서간의 배열을 고려한 데이터 차분 과정을 통해 목표물의 2차원적 움직임 정보를 추출한다. 추출된 데이터 값과 peak 값의 시차정보를 이용하여 DTW(Dynamic Time Warping) 제스처 인식 및 보정 알고리즘을 구현하였으며, 다섯가지 동작 시나리오 테스트 결과 95% 이상의 높은 인식률을 보였다.

일부 우리나라 여대생의 식사 패턴군에 따른 골밀도에 영향을 미치는 요인 분석 (Factors Affecting Bone Mineral Density by Dietary Pattern Group for Some Korean College Women)

  • 송윤주;백희영;유춘희
    • Journal of Nutrition and Health
    • /
    • 제39권5호
    • /
    • pp.460-466
    • /
    • 2006
  • To investigate the effects of dietary patterns on bone mineral density and its biochemical markers among Korean healthy college women for 2 years, 34 female college students were recruited through convenience sampling. Bone mineral density was measured using Dual Energy X-ray Absorptiometry (DEXA) twice at baseline and two years later. Osteocalcin and parathyroid hormone were measured in fasting serum and N-teleopeptides of type collagen (NTx) in urine. Dietary intake was assessed by 24-hour recall method 8 times with average 4-month interval. Dietary patterns with percent energy of each food group using cluster analysis were classified into two groups. The first cluster (n = 16) was characterized with high consumption of bread, snack, fast foods, beverage and considerable of rice so it was determined as 'Modified dietary pattern group'. The second cluster was characterized with high consumption of rice and kimchi so determined as 'Traditional dietary pattern group'. There were no significant difference of age, menarcheal age, body mass index but percent of body fat by pattern groups. The traditional group showed higher value of bone mineral density among lumber spine and all femur sites at baseline and 2 years later but it was not significant after adjusted for percent of body fat. Serum osteocalcin and urine NTx was higher among the traditional group at baseline than the modified group. There were similar proportions of carbohydrate:fat:protein between groups but significantly higher intake of protein, iron, vitamin A among the traditional group. In conclusion, there were two distinctive dietary patterns among Korean college women. There was difference of bone mineral density and its biochemical markers between two patterns. Further research would be necessary to explore the relationship between dietary patterns and health risks for larger-sized and various populations.

주택특성에 관련된 실내 이산화질소 농도에 관한 연구 (A Study on Concentration of Indoor Nitrogen Dioxide in Relation to House Characteristics)

  • 양원호;배현주;김현용;정문식;정문호
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.85-92
    • /
    • 1999
  • Indoor air quality tends to be the dominant contributor to personal exposure because most people spend over 90% of their time indoors. For some contaminants, exposure to indoor air poses a potentially greater health threat than outdoor air exposures. Indoor nitrogen dioxide ($NO_2$) levels are mainly affected gas range, flue gas spillage, kerosene heaters, wood-burning appliances and cigarette smoke. In addition, indoor $NO_2$ levels are influenced by such house characterization as surface reaction and air exchange rate. In this study, the measurements of indoor and outdoor $NO_2$ concentrations were taken using identical protocols, and information was collected on housing characteristics using identical questionnaires in 14 houses out of 15 houses for daily 30 daily 30 days in Brisbane, Australia.The usage of gas range was the most contributing factor in indoor $NO_2$ concentration in relation to house characteristics. Average indoor and outdoor ratios of NO2 concentration in electronic and gas cooking houses were $0.6{\pm}0.1$ and $0.9{\pm}0.2$, respectively. The frequency distributions of $NO_2$ concentration in each house were approximately log-normal Geometric mean of indoor $NO_2$ concentrations of electronic and gas cooking houses for daily 30 days ranged from 2.5 ppm to 11.5 ppm with a mean 6.8 and from 4.7 ppm to 28.6 ppm with a mean 15.6 ppm, respectively. The $NO_2$ concentrations between electronic and gas cooking houses were significantly different (p<0.05). Since each house has different life-style and house characteristics, sampling interval to measure the $NO_2$ levels was recommended above 7 days.

  • PDF

해안지역 대기부유미립자상 물질의 특성에 관한 연구 (A Study on the Characteristics of Ambient Suspended Particulate Matter at Coastal Area, Kangwha)

  • 강공언;우상윤;강병욱;김희강
    • 한국환경보건학회지
    • /
    • 제20권4호
    • /
    • pp.1-9
    • /
    • 1994
  • In order to investigate the regional level of air pollutants at Kangwha island situated on the western coast in Korea, the suspended particulate matter samples were collected by using the low volume air sampler on ten interval from March 1992 to February 1993 and the mass concentration of suspended particulate matter (SPM) and the chemical composition of water-soluble major ionic components in SPM samples were measured. During the sampling period, the average concentration of SPM under diameter 10 $\mu$m was found to be 48 $\mu$g/m$^3$ (+ 12). The seasonal concentration of SPM was showed in order of spring>fall>winter>summer. It was considered that higher concentration on spring than other season was affected by the long-range transport of Yellow sand particulate from China continent and lower concentration on summer by the washout and rainout effect of large rainfall. The content of water-soluble component in SPM samples was founded to be about 31% (14.69 $\mu$g/m$^3$) and 65% was unknown or unanalyzed. The content of cationic component showed in order of NH$_4^+$ (44.6%)>Na$^+$ (21.2%)>K$^+$ (14.7%)>Ca$^{2+}$ (13.6%)>Mg$^{2+}$ (5.9 %) and the content of anionic component SO$_4^{2-}$ (62.5%)>NO$_3^-$ (22.3%)>Cl$^-$ (15.2%), respectively. This fact indicates that ammonium and sulfate ion of water-soluble component in SPM sample were dominant in this region. From the chemical composition of water-soluble component, the most of Na$^+$, Mg$^{2+}$ and Cl$^-$ were originated from seawater source but K$^+$, Ca$^{2+}$ and SO$_4^{2-}$ were originated from other non-marine source. The contribution of seasalt to the composition of precipitation was 23%.

  • PDF

입원환아 부모의 간호요구 (Nursing Needs of Parents with Hospitalized Child)

  • 서영미;권인수;조명옥;최운주
    • Child Health Nursing Research
    • /
    • 제5권1호
    • /
    • pp.59-69
    • /
    • 1999
  • The main purpose of this study is to identify nursing needs of parents who have hospitalized child. Research design is a descriptive survey. The subjects for the study were 79 parents who have hospitalized child at a pediatric ward of one of the general hospital attached to a university in J city. The data was collected by researchers using a structured questionnaire. The questionnaire was Likert type 5 point scale, composed of 5 categories with 61 items. The data was analyzed by SPSS/PC. The results of the study were as follows ; 1) Mean score of nursing needs of subjects were 3.93 at 2nd day of admission and 3.99 at 7th day of admission. 2) Among the categories, the highest nursing need at the End day and 7th day of admission was ‘dilect nursing’, in desending order, ‘facilities and environment’, ‘education and counseling’, ‘nursing assessment’. The lowest nursing need was ‘reference’. 3) Differences between the nursing needs of subjects at 2nd day and 7th day were as follows : (1) By categories, there was a significant difference only in the ‘reference’ categoly(t=2.74, P=.008). (2) By items, there were significant differences in items of ‘to check necessary materials(t=2.31, P=.024)’, ‘to understand family function and family relationship(t=2.12, P=.041)’, ‘to set up study room(t=2.22, P=.030)’, and ‘to mediate parent's meeting group(t=3.89, P=.000)’. The above result indicated that nursing needs of parents with hospitalized child were above average, especially very high in items about disease process, and items directly associated with treatment and nursing care. So, nurses have to focus on information about the patient's state of disease, treatment, test and procedure, and in efficiently giving direct nursing care to implement mure effective care for the hospitalized children and their parents. And some future researche is needed to identify the difference of degree of nursing needs of parents with hospitalized child according to admission duration using a different sample and a longer sampling interval.

  • PDF