• Title/Summary/Keyword: average sampling interval

Search Result 76, Processing Time 0.026 seconds

Study on the Short Term Exposure Level (STEL) of the Benzene for the Tank Lorry Truck Drivers during Loading Process

  • Park Doo Yong
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.27-31
    • /
    • 2004
  • Some of the petroleum products contain benzene which is well known as a confirmed human carcinogen. For example, gasoline products contain benzene ranging up to several percents by weight. High exposures to the benzene and other organic solvents would be likely to occur during intermittent tasks and or processes rather than continuous jobs such as sampling, repair, inspection, and loading/unloading jobs. The work time for these jobs is various. However, most of work time is very short and the representative time interval is 15 minutes. Thus, it is preferable to do exposure assessment for 15 minute time weighted average which is known as a short time exposure level(STEL) by ACGIH rather than for 8-hours TWA. It is particularly significant to the exposure monitoring for benzene since it has been known that the exposure rate plays an important role to provoke the leukemia. Due to the large variations, a number of processes/tasks, the traditional sampling technique for organic solvents with the use of the charcoal and sampling pumps is not appropriate. Limited number of samples can be obtained due to the shortage of sampling pumps. Passive samplers can eliminate these limitations. However, low sampling rates resulted in collection of small amount of the target analysts in the passive samplers. This is originated the nature of passive samplers. Field applications were made with use of passive samplers to compare with the charcoal tube methods for 15 minutes. Gasoline loading processes to the tank lorry trucks at the loading stations in the petroleum products storage area. Good agreements between the results of passive samplers and those of the charcoal tubes were achieved. However, it was found that special cautions were necessary during the analysis at very low concentration levels.

Somatic Cell Counts in Marrah Buffaloes (Bubalus bubalis) During Different Stages of Lactation, Parity and Season

  • Singh, Mahendra;Ludri, R.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.2
    • /
    • pp.189-192
    • /
    • 2001
  • This study was initiated in an effort to determine the normal mean and variations of the somatic cell count (SCC) in milk of buffaloes as influenced by the milking time, stage of lactation, parity and season. The buffaloes were hand milked at 13 and 11 h. interval during evening and morning respectively. On the day of milk sampling the udders were tested for mastitis by California Mastitis Test (CMT). Only those buffaloes, which were found negative in the CMT, were included in the sampling plan. The mean values for morning and evening were 1.09 (range 0.39-1.76) and $0.97(range\;0.57-2.46){\times}10^5cells/ml$, respectively which did not differ significantly. When data of the morning and evening values was compared on the basis of total cell secretion in milk, even then there was no statistical difference between the morning and the evening values, thereby suggesting that no diurnal variation existed in SCC of milk. Paritywise differences were not significant between the 1st to 5th lactation and above. Similarly stage of lactation effect, when tested at 30 day intervals, did not differ significantly. Significant (p<0.05) correlation coefficients (r) between SCC and milk yield during different stages of lactation and parity suggested that SCC per ml of milk was higher during the later stages of lactation. SCC was higher in primiparous than in multiparous buffaloes. On an average the SCC recorded was $1.0{\times}10^5cells/ml$ of milk irrespective of time of milking, parity and stages of lactation. The SCC was low during cold and hot-dry season but were high during the hot-humid season (p<0.05), the respective values being 0.76, 1.08 and $1.35{\times}10^5cells/ml$. These values were lower than the SCC already reported in cows suggesting less stressful condition of the udder of buffaloes in this study.

Premature Ventricular Contraction Classification through R Peak Pattern and RR Interval based on Optimal R Wave Detection (최적 R파 검출 기반의 R피크 패턴과 RR간격을 통한 조기심실수축 분류)

  • Cho, Ik-sung;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.233-242
    • /
    • 2018
  • Previous works for detecting arrhythmia have mostly used nonlinear method such as artificial neural network, fuzzy theory, support vector machine to increase classification accuracy. Most methods require higher computational cost and larger processing time. Therefore it is necessary to design efficient algorithm that classifies PVC(premature ventricular contraction) and decreases computational cost by accurately detecting feature point based on only R peak through optimal R wave. For this purpose, we detected R wave through optimal threshold value and extracted RR interval and R peak pattern from noise-free ECG signal through the preprocessing method. Also, we classified PVC in realtime through RR interval and R peak pattern. The performance of R wave detection and PVC classification is evaluated by using 9 record of MIT-BIH arrhythmia database that included over 30. The achieved scores indicate the average of 99.02% in R wave detection and the rate of 94.85% in PVC classification.

Water Saving Irrigation Manual of Red Pepper for the Southern Region of Korea (우리나라 남부권역 노지재배 고추의 물절약형 관개 기준 설정 연구)

  • Eom, Ki-Cheol;Yoo, Sung-Yung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.306-311
    • /
    • 2012
  • Water management is the most important and difficult problems in red pepper cultivation.The water requirement of red pepper is different according to the area as well as climate condition, growth stage and soil texture. Also, the measurement of evapo-transpiration (PET) and crop coefficient (Kc) is very difficult especially in field cultivation. The average PET during 30 years of southern region of korea for the red pepper cultivation was a $2.75mm\;day^{-1}$. The water saving irrigation manual with irrigation interval and amount of irrigation according to growing season and soil texture, are developed based on the lysimeter experiments carried out by the RDA for 11 years about potential evapo-transpiration, crop coefficient for the 17 southern region of korea. The water saving irrigation manual can be used with easy to the farmer without soil sampling and any kinds of sensors measuring soil water status.

Digitally Current Controlled DC-DC Switching Converters Using an Adjacent Cycle Sampling Strategy

  • Wei, Tingcun;Wang, Yulin;Li, Feng;Chen, Nan;Wang, Jia
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.227-237
    • /
    • 2016
  • A novel digital current control strategy for digitally controlled DC-DC switching converters, referred to as Adjacent Cycle Sampling (ACS), is proposed in this paper. For the ACS current control strategy, the available time interval from sampling the current to updating the duty ratio, is approximately one switching cycle. In addition, it is independent of the duty ratio. As a result, the contradiction between the processing speed of the hardware and the transient response speed can be effectively relaxed by using the ACS current control strategy. For digitally controlled buck DC-DC switching converters with trailing-edge modulation, digital current control algorithms with the ACS control strategy are derived for three different control objectives. These objectives are the valley, average, and peak inductor currents. In addition, the sub-harmonic oscillations of the above current control algorithms are analyzed and eliminated by using the digital slope compensation (DSC) method. Experimental results based on a FPGA are given, which verify the theoretical analysis results very well. It can be concluded that the ACS control has a faster transient response speed than the time delay control, and that its requirements for hardware processing speed can be reduced when compared with the deadbeat control. Therefore, it promises to be one of the key technologies for high-frequency DC-DC switching converters.

Considering Aspects for the Revision of Current Bioequivalence Guideline (국내 생물학적 동등성 시험 기준 개정 방향)

  • Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.4
    • /
    • pp.233-242
    • /
    • 2009
  • Bioequivalence (BE) studies provide important information in the overall set of data that ensure the availability of safe and effective medicines to patients and practitioners. Thus its determination of proper criterion for assessing BE is very important. BE is frequently expressed or measured by estimating area under the plasma concentration-time curve (AUC) and maximum concentration ($C_{max}$) that are reflective of systemic exposure. In all countries except Canada, the acceptance criteria of BE is that the 90% confidence interval of difference in the average values of logarithmic AUC and $C_{max}$ between test and reference products is within the acceptable range of log(0.8) ${\sim}$ log(1.25). In Canada, unlike other countries, point estimation instead of applying 90% confidence interval is applied to assess $C_{max}$ which is, in essence, more variable than AUC. We also compared other parts of BE guidelines which include a fed study, average BE (ABE), scaled-ABE, population BE (PBE), individual BE (IBE), dropout & withdrawal, sampling frequency & time and number of subjects. This article reviews the most recent BE guidelines of Korea, USA, Europe, Canada and Japan, highlighting the differences focused on Korean BE guidelines compared to other countries. It will help us to revise BE guideline of Korea reflecting international trends. Finally, it is strongly recommended that the extended acceptance criterion for the highly variable drug among all the considering aspects for the revision of current BE guideline has to be adopted into Korea BE guideline in the nearest future.

Characteristics and Combined Sewer Overflows (합류식 하수관거의 유출 특성 분석 조사)

  • An, Ki-Sun;Jang, Sung-Ryong;Kwon, Young-Ho
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.747-753
    • /
    • 2010
  • It follows in quality and sewage exclusion method of the investigation objective sector and the Combined Sewer Overflows which is suitable in regional characteristics and the confluence area against the rainfall initially a flow and the medulla and measurement - it analyzes the initial rainfall outflow possibility control plan which is suitable in the domestic actual condition and it proposes the monitor ring plan for the long-term flow and pollution load data accumulation. From the research which it sees the Infiltration water/Influent water and CSOs investigation it passes by the phase of hazard chain and Namwon right time 4 it does not hold reverse under selecting, Measurement it used the hazard automatic flow joint seal Sigma 910 machine and in case 15 minute interval of the I/I, it measured a flow at case 5, 15 minute standing of the CSOs. The water quality investigation for the water leakage investigation of the I/I and the sewage from the point which is identical with flow measurement during on-the-spot inspection duration against 6 items which include the BOD sampling and an analysis, when the rainfall analysis for CSOs fundamental investigation analyzed against 18 items which include the BOD sampling. Consequently, for the optimum interpretation invasion water / inflow water of the this investigation area day average the lowest flow - water quality assessment veterinarian optimum interpretation hazard average per day - lowest flow - it averages a medulla evaluation law department one lowest flow evaluation technique and it selects, it presentation collectively from here it gets, position result with base flow analysis of invasion water / inflow water.

Economic-Statistical Design of VSSI$\bar{X}$ Control Charts Considering Two Assignable Causes (두 개의 이상원인을 고려한 VSSI$\bar{X}$ 관리도의 경제적-통계적 설계)

  • Lee, Ho-Joong;Lim, Tae-Jin
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.31 no.1
    • /
    • pp.87-98
    • /
    • 2005
  • This research investigates economic-statistical characteristics of variable sampling size and interval (VSSI)$\bar{X}$charts under two assignable causes. A Markov chain approach is employed in order to calculate average run length (ARL) and average time to signal (ATS). Six transient states are derived by carefully defining the state. A steady state cost rate function is constructed based on Lorenzen and Vance(1986) model. The cost rate function is optimized with respect to six design parameters for designing the VSSI $\bar{X}$ charts. Computational experiments show that the VSSI $\bar{X}$ chart is superior to the Shewhart $\bar{X}$ chart in the economic-statistical sense, even under two assignable causes. A comparative study shows that the cost rate may increase up to almost 30% by overlooking the second cause. Critical input parameters are also derived from a sensitivity study and a few guideline graphs are provided for determining the design parameters.

Design of Acceptance Control Charts According to the Process Independence, Data Weighting Scheme, Subgrouping, and Use of Charts (프로세스의 독립성, 데이터 가중치 체계, 부분군 형성과 관리도 용도에 따른 합격판정 관리도의 설계)

  • Choi, Sung-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.3
    • /
    • pp.257-262
    • /
    • 2010
  • The study investigates the various Acceptance Control Charts (ACCs) based on the factors that include process independence, data weighting scheme, subgrouping, and use of control charts. USL - LSL > $6{\sigma}$ that used in the good condition processes in the ACCs are designed by considering user's perspective, producer's perspective and both perspectives. ACCs developed from the research is efficiently applied by using the simple control limit unified with APL (Acceptable Process Level), RLP (Rejectable Process Level), Type I Error $\alpha$, and Type II Error $\beta$. Sampling interval of subgroup examines i.i.d. (Identically and Independent Distributed) or auto-correlated processes. Three types of weight schemes according to the reliability of data include Shewhart, Moving Average(MA) and Exponentially Weighted Moving Average (EWMA) which are considered when designing ACCs. Two types of control charts by the purpose of improvement are also presented. Overall, $\alpha$, $\beta$ and APL for nonconforming proportion and RPL of claim proportion can be designed by practioners who emphasize productivity and claim defense cost.

Phytoplankton Community in Adjacent Waters of Ulchin Nuclear Power Plant

  • Choi, Hyu Chang;Kang, Yeon Shik;Jeon, In Sung
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.3
    • /
    • pp.426-437
    • /
    • 2004
  • To understand the phytoplankton community in adjacent waters of Ulchin nuclear power plant (UNPP), abundance and the size fractionated $chl-\alpha$ concentrations were evaluated through seasonal interval sampling from April 2003 to February 2004. A total of 211 different phytoplankton species was observed and mean abundance of phytoplankton in each study period ranged from 244,286 to 1,221,779 cells $L^{-1}$. The contributions of microplankton $(>20\mu{m})$ to total phytoplankton abundance ranged from 42.5 to 83.6% (average 66.1%) and those of nanoplankton $(>20\mu{m})$ ranged from 16.4 to 57.5% (average 33.9%). Total chl-$\alpha$ concentrations of phytoplankton ranged from 0.52 to $2.26\mu{g}\;L^{-1}$. The contribution of chl-$\alpha$ concentrations of microplankton was higher than that of nano- and picoplankton through the study period with exception of July 2008. The results of abundances and $chl-\alpha$ concentrations suggest that microplankton has an important role in adjacent waters of UNPP. The diminution of abundances and $chl-\alpha$ concentrations of phytoplankton was observed after passage through the cooling water system, but it was gradually recovered by mixing with the ambient waters. Our results suggested that the influence of thermal discharges on phytoplankton should be restricted within narrow limits around outlet area of thermal effluents.