• 제목/요약/키워드: average radiation dose

검색결과 600건 처리시간 0.226초

항공승무원의 우주방사선 피폭 저감에 관한 연구 (A Study on the Reduction of Cosmic Radiation Exposure by Flight Crew)

  • 안희복;김규왕;최연철
    • 한국항공운항학회지
    • /
    • 제28권1호
    • /
    • pp.1-6
    • /
    • 2020
  • The purpose of this study is to analyze the radiation dose data of the space crew of the flight crew and to present a plan for the health management of the flight crew on the basis of the analysis. The analysis show that the average exposure dose of the flight attendants continued to rise, and the exposure dose of the flight attendants was five(5) times higher than that of the radiation workers. As a way to reduce the effects of cosmic radiation, this paper suggests appropriate personnel allocation by model, balanced allocation of high and low latitude routes by crew according to the aircraft type, and a low altitude flight plan for high latitude flight. This study will help aviation crew members understand cosmic radiation and trust in the company's policies. In the future, it will be necessary to enhance the flight safety of the crew by deriving meaningful results by analyzing data related to cosmic radiation of various routes.

척추 방사선수술 시 다엽콜리메이터 위치 오차의 임상적 위험성 평가 (Evaluation of Clinical Risk according to Multi-Leaf Collimator Positioning Error in Spinal Radiosurgery)

  • 강동진;오건;신영주;강진규;정재용;이보람
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.527-533
    • /
    • 2023
  • The purpose of this study is to evaluate the clinical risk of spinal radiosurgery by calculating the dose difference due to dose calculation algorithm and multi-leaf collimator positioning error. The images acquired by the CT simulator were recalculated by correcting the multi-leaf collimator position in the dose verification program created using MATLAB and applying stoichiometric calibration and Monte Carlo algorithm. With multi-leaf collimator positioning error, the clinical target volume (CTV) showed a dose difference of up to 13% in the dose delivered to the 95% volume, while the gross tumor volume (GTV) showed a dose difference of 9%. The average dose delivered to the total volume showed dose variation from -8.9% to 9% and -10.1% to 10.2% for GTV and CTV, respectively. The maximum dose delivered to the total volume of the spinal cord showed a dose difference from -14.2% to 19.6%, and the dose delivered to the 0.35 ㎤ volume showed a dose difference from -15.5% to 19.4%. In future research, automating the linkage between treatment planning systems and dose verification programs would be useful for spinal radiosurgery.

옥천층군 일대의 지표방사능과 감마선량 평가 (Evaluation of Terrestrial Gamma Radiation and Dose Rate of the Ogcheon Group Area)

  • 윤욱;조병욱
    • 지질공학
    • /
    • 제30권4호
    • /
    • pp.577-588
    • /
    • 2020
  • 일부 암석의 우라늄 함량이 높은 것으로 알려진 옥천층군 지역의 유효선량을 파악하기 위하여 휴대용 감마선분광분석기를 이용하여 421개 지점에서 지표방사능(40K, eU, eTh)을 측정하였다. 연구지역을 5개의 지질(og1, og2, og3, og4, 화성암)로 구분했을 때 지질별 지표방사능 강도에는 큰 차이가 없었다. 전체 421 암석의 40K, eU, eTh의 함량은 각각 0.7~10.3% (평균 5.2%), 0.6~287.0 ppm (평균 8.5 ppm), 4.0~102.4 ppm (평균 31.3 ppm) 을 보였다. 방사능강도로부터 구한 연구지역의 흡수선량은 28.84~1,714.5 nGy/h의 범위로서(평균 195.4 nGy/h) 지질별 평균값 최저는 og1의 166.3 nGy/h, 최고는 og2의 233.3 nGy/h(중앙값은 198.1 nGy/h였다. 흡수선량으로부터 구한 연구지역의 옥외 유효선량은 0.04~2.10 mSv/y (평균 0.24 mSv/y)의 범위이며 함 우라늄층이 협재된 og2에 위치한 4개 지점을 제외하면 옥외 유효선량이 1 mSv/y를 넘는 지점은 없었다.

일반 및 호흡조절 방사선치료계획에서 심장의 흡수선량 변화 (A Change in an Absorbed Dose of the Heart in General and Respiratory Control Radiation Treatment Plans)

  • 양은주;김영재
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.313-319
    • /
    • 2018
  • 방사선 치료시 산란성 등의 피부영향을 피할 수 없으며 내부의 정상장기의 피폭은 피할 수 없다. 방사선 치료의 역사는 정상조직의 흡수선량 감소를 위한 역사라고 해도 과언이 아니다. 특히, 왼쪽 유방암의 방사선 치료시 내부 인접 장기로는 정상유방조직, 심장과 폐를 대표로 들 수 있는데 심장에 발생할 수 있는 부작용은 심정지, 심근경색 등이 있다. 본 논문에서는 왼쪽 유방암 환자의 방사선 치료시 호흡조절기법을 사용한 것과 일반 방사선치료계획을 시행하는 것 사이에 심장의 체적과 선량의 변화를 관찰하여 호흡으로 인해 발생하는 심장의 체적과 선량을 알아보았다. 연구결과 4차원 컴퓨터 단층촬영영상을 기준으로 심장의 체적은 평균 $12.8{\pm}8.7cc$의 차이가 나타났으며 이에 대해 선량은 평균 $17.3{\pm}12.1cGy$의 차이를 보였다. 이러한 체적과 선량의 차이는 향후 방사선 치료시 부작용을 발생시킬 수 있는 우려가 있으므로 호흡조절기법을 활용하여 심장의 정확한 위치를 기반으로 방사선 치료계획을 수립하여야 할 것이다.

방사선 작업종사자의 피폭선량 비교 평가 (Comparative evaluation of radiation exposure in radiation-related workers)

  • 백성민;장은성
    • 한국방사선학회논문지
    • /
    • 제5권4호
    • /
    • pp.195-200
    • /
    • 2011
  • 최근의 방사선 피폭 선량을 조사하여 그 경각심을 일깨워주기 위함이다. 그 분석결과, K병원의 2008년도 평균피폭 선량은 $0.75{\pm}0.26mSv$, 2009년은 $0.67{\pm}0.30mSv$, 2010년은 $0.92{\pm}0.33mSv$였다. P병원은 2008년이 $0.43{\pm}0.13mSv$, 2009년 $0.43{\pm}0.20mSv$, 2010년이 $0.33{\pm}0.85mSv$로 나타났으며, 연령별 평균 피폭선량은 K병원의 20대가 13.39mSv, 30대 8.37mSv, 40대 1.19mSv, 50대 0.28mSv, 60대 0.32mSv로 나타났고 P병원은 20대 0.33mSv, 30대 1.41mSv, 40대 0.83mSv, 50대 1.66mSv, 60대 1.12mSv 였다. 또한 3년간 피폭선량의 평균을 성별로 나누어서 나타냈는데 K병원에서 남자의 피폭선량은 $2.92{\pm}1.03mSv$, 여자의 피폭선량은 $0.94{\pm}0.93mSv$였다. P병원에서의 남자의 피폭 선량은 $0.66{\pm}0.18mSv$이고 여자는 $1.80{\pm}0.60mSv$로 나타났다. 방사선을 취급하는 과별로 받는 년간 평균 피폭 선량은 영상의학과 $1.65{\pm}1.54mSv$, 방사선종양학과 $1.17{\pm}0.82mSv$, 핵의학과 $1.79{\pm}1.42mSv$, 기타 $0.99{\pm}0.51mSv$였으며 상대적으로 저선량율 에너지를 사용하는 핵의학과에서 다른 과와 비교해서 방사선 피폭이 높게 나타났으며(p<0.05), 핵의학과내에서는 특히 동위원소 조작실과 주입실의 년간 평균 피폭량이 $3.69{\pm}1.81mSv$으로 많은 피폭을 받고 있었다(p<0.01). 직종별 연평균 피폭선량은 의사 $1.75{\pm}1.17mSv$, 방사선사 $1.60{\pm}1.39mSv$, 간호사 $0.93{\pm}0.35mSv$, 기타 $1.00{\pm}0.3mSv$로 의사와 방사선사가 다른 직종에 비해 높게 나타났다(p<0.05). 방사선 작업 종사자에 대한 피폭측정 및 평가가 철저히 이루어져 피폭 가능성을 줄이는데 관심과 주의가 필요하며 누적 선량을 최소화하여 방사선 작업 종사자의 건강을 유지하고 증진 시켜야 할 것이다.

전뇌 방사선 치료 시 갑상선 차폐체의 주변선량 차폐효과에 대한 유용성 평가 (Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy)

  • 양명식;차석용;박주경;이승훈;김양수;이선영
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.265-272
    • /
    • 2014
  • 목 적 : 전뇌 방사선 치료 시 산란선으로 인하여 영향을 받는 갑상선의 피폭선량을 감소시키기 위해 차폐체를 사용하여 갑상선의 차폐 효과를 평가하고자 한다. 대상 및 방법 : 갑상선의 피폭선량을 측정하기 위해 선형가속기(Clinac iX. VARIAN, USA)를 이용하여 6 MV X선, 300 cGy를 인체모형팬텀에 대향 2문 조사하였다. 갑상선의 입사표면선량을 측정하기 위해 인체모형팬텀의 10번째 슬라이스 표면에 유리선량계 다섯 개를 1.5 cm 간격으로 위치시킨 후 차폐체 미사용, bismuth 차폐체 사용, 0.5 mmPb 차폐체 사용, 자체 제작한 1.0 mmPb 차폐체를 사용하여 각각 5회씩 측정하여 평균값을 산출하였다. 또한, 같은 위치에서 갑상선 심부선량을 측정하기 위해서 인체모형팬텀의 10번째 슬라이스 2.5 cm 깊이에서 유리선량계 다섯 개를 1.5 cm 간격으로 위치시킨 후 차폐체 미사용, bismuth 차폐체 사용, 0.5 mmPb 차폐체 사용, 자체 제작한 1.0 mmPb 차폐체를 사용하여 각각 5회씩 측정하여 평균값을 산출하였다. 결 과 : 갑상선의 입사표면선량은 차폐체 미사용 시 44.89 mGy로 측정되었고, bismuth 차폐체는 36.03 mGy, 0.5 mmPb 차폐체는 31.03 mGy, 자체 제작한 1.0 mmPb 차폐체는 23.21 mGy로 측정되었다. 또한, 갑상선의 심부선량은 차폐체 미사용 시 36.10 mGy로 측정되었고, bismuth 차폐체는 34.52 mGy, 0.5 mmPb 차폐체는 32.28 mGy, 자체 제작한 1.0 mmPb 차폐체는 25.50 mGy로 측정되었다. 결 론 : 전뇌 방사선 치료 시 방사선 조사면 밖의 영역에서 발생하는 이차 산란 및 누출 선량에 의해 영향을 받는 갑상선에 대하여 차폐체를 사용했을 때 갑상선 심부는 약 11~30%, 갑상선 표면은 약 20~48% 정도의 피폭선량 감소 효과가 나타났다. 따라서 전뇌 방사선 치료 시 갑상선 차폐체를 사용함으로써 갑상선을 효과적으로 보호하며 치료를 시행할 수 있을 것으로 사료된다.

Low-dose Radiation Induces Antitumor Effects and Erythrocyte System Hormesis

  • Yu, Hong-Sheng;Liu, Zi-Min;Yu, Xiao-Yun;Song, Ai-Qin;Liu, Ning;Wang, Hao
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권7호
    • /
    • pp.4121-4126
    • /
    • 2013
  • Objective: Low dose radiation may stimulate the growth and development of animals, increase life span, enhance fertility, and downgrade the incidence of tumor occurrence.The aim of this study was to investigate the antitumor effect and hormesis in an erythrocyte system induced by low-dose radiation. Methods: Kunming strain male mice were subcutaneously implanted with S180 sarcoma cells in the right inguen as an experimental in situ animal model. Six hours before implantation, the mice were given 75mGy whole body X-ray radiation. Tumor growth was observed 5 days later, and the tumor volume was calculated every other day. Fifteen days later, all mice were killed to measure the tumor weight, and to observe necrotic areas and tumor-infiltration-lymphoreticular cells (TILs). At the same time, erythrocyte immune function and the level of 2,3-diphosphoglyceric acid (2,3-DPG) were determined. Immunohistochemical staining was used to detect the expression of EPO and VEGFR of tumor tissues. Results: The mice pre-exposed to low dose radiation had a lower tumor formation rate than those without low dose radiation (P < 0.05). The tumor growth slowed down significantly in mice pre-exposed to low dose radiation; the average tumor weight in mice pre-exposed to low dose radiation was lighter too (P < 0.05). The tumor necrosis areas were larger and TILs were more in the radiation group than those of the group without radiation. The erythrocyte immune function, the level of 2,3-DPG in the low dose radiation group were higher than those of the group without radiation (P < 0.05). After irradiation the expression of EPO of tumor tissues in LDR group decreased with time. LDR-24h, LDR-48h and LDR-72h groups were all statistically significantly different from sham-irradiation group. The expression of VEGFR also decreased, and LDR-24h group was the lowest (P < 0.05). Conclusion: Low dose radiation could markedly increase the anti-tumor ability of the organism and improve the erythrocyte immune function and the ability of carrying $O_2$. Low-dose total body irradiation, within a certain period of time, can decrease the expression of hypoxia factor EPO and VEGFR, which may improve the situation of tumor hypoxia and radiosensitivity of tumor itself.

Discrepancies in Dose-volume Histograms Generated from Different Treatment Planning Systems

  • Kim, Jung-in;Han, Ji Hye;Choi, Chang Heon;An, Hyun Joon;Wu, Hong-Gyun;Park, Jong Min
    • Journal of Radiation Protection and Research
    • /
    • 제43권2호
    • /
    • pp.59-65
    • /
    • 2018
  • Background: We analyzed changes in the doses, structure volumes, and dose-volume histograms (DVHs) when data were transferred from one commercial treatment planning system (TPS) to another commercial TPS. Materials and Methods: A total of 22 volumetric modulated arc therapy (VMAT) plans for nasopharyngeal cancer were generated with the Eclipse system using 6-MV photon beams. The computed tomography (CT) images, dose distributions, and structure information, including the planning target volume (PTV) and organs at risk (OARs), were transferred from the Eclipse to the MRIdian system in digital imaging and communications in medicine (DICOM) format. Thereafter, DVHs of the OARs and PTVs were generated in the MRIdian system. The structure volumes, dose distributions, and DVHs were compared between the MRIdian and Eclipse systems. Results and Discussion: The dose differences between the two systems were negligible (average matching ratio for every voxel with a 0.1% dose difference criterion = $100.0{\pm}0.0%$). However, the structure volumes significantly differed between the MRIdian and Eclipse systems (volume differences of $743.21{\pm}461.91%$ for the optic chiasm and $8.98{\pm}1.98%$ for the PTV). Compared to the Eclipse system, the MRIdian system generally overestimated the structure volumes (all, p < 0.001). The DVHs that were plotted using the relative structure volumes exhibited small differences between the MRIdian and Eclipse systems. In contrast, the DVHs that were plotted using the absolute structure volumes showed large differences between the two TPSs. Conclusion: DVH interpretation between two TPSs should be performed using DVHs plotted with the absolute dose and absolute volume, rather than the relative values.

ED3를 이용한 방사성동위원소 의약품의 수정체 피폭선량평가 (Estimation of Lens Dose of Radioactive Isotopes Using ED3)

  • 송하진;주용진;장한;동경래;강경원;최은진;곽종길;류재광;정운관
    • 방사선산업학회지
    • /
    • 제11권1호
    • /
    • pp.19-25
    • /
    • 2017
  • It is suggested that the dose limit recommended in the Enforcement Decree of Korea's Nuclear Safety Act should not exceed 150 mSv per year for radiation workers. Recently, however, ICRP 118 report has suggested that the threshold dose of the lens should be reduced to 0.2~0.5 Gy and the mean dose should not exceed 50 mSv per year for an average of 20 mSv over 5 years. Based on these contents, $^{123}I$, $^{99m}Tc$, and $^{18}F-FDG$, which are radioisotope drugs that are used directly by radiation workers in the nuclear medicine department in Korea are expected to receive a large dose of radiation in the lens in distribution and injection jobs to administer them to patients. The ED3 Active Extremity Dosimeter was used to measure the dose of the lens in the nuclear medicine and radiation workers and how much of the dose was received per 1 mCi.

131I 방사성 동위원소 치료에 따른 피폭 선량 연구 (The Study of Radiation Exposed dose According to 131I Radiation Isotope Therapy)

  • 장보석;유승만
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.653-659
    • /
    • 2019
  • 본 연구는 고용량 $^{131}I$ 치료 후 방사선원이 된 퇴원 환자로부터 나오는 방사선 피폭에 관해 외부 선량률을 측정하고, 그에 따른 피폭선량을 예측하는 것이 목적이다. 200 mCi 이상 고용량 $^{131}I$ 치료를 받은 30명의 환자에서 구리링 3개를 이용하여 환자로부터 거리 및 방위각에 따른 선량평가를 시행하였다. 정확한 방사선 계측을 위하여 GM 계측기를 이용하여 2명의 측정자가 방위각 8 포인트와 거리 변화를 주며 계측하였다. 측정값을 기반으로 3가지 예측 시뮬레이션을 설정하여 불특정 다수 일반인에 대한 피폭선량을 계산하였다. 1m 높이에서 방위각에 따른 외부 선량률이 가장 높은 부위는 0도이다. 거리에 따른 선량률은 거리별 방위각의 선량률 평균값을 사용하였다. 거리에 따른 외부 선량률의 최고치는 50, 100, 150 cm에서 각각 $214{\pm}16.5$, $59{\pm}9.1{\mu}Sv/h$, $38{\pm}5.8{\mu}Sv/h$ 이다. 고용량 $^{131}I$ 치료 환자가 대중교통을 이용해서 5시간 이동할 때 반경 50 cm 지점의 옆좌석에 안은 불특정 일반인이 받을 수 있는 피폭선량은 1.14 mSv이다. 소변 통(urin bag)을 착용한 퇴원환자로부터 100 cm 거리에서 4일 동안 간병인이 받을 수 있는 최대 피폭선량은 6.5 mSv이다. 퇴원 환자 귀가로 인해 7일 동안 150 cm 거리에서 보호자가 받을 수 있는 최대 피폭선량은 1.08 mSv이다. 개발된 예측 모델링으로 불특정 $^{131}I$ 치료 환자의 주변 일반인에게 적용하였을 때 연간 선량 한도를 단시간에 초과하는 수준이었다. 따라서 본 연구를 통해 현행 고용량 $^{131}I$ 치료 환자의 퇴원 후 주변의 일반인의 방호체계의 합리적인 가이드라인을 제시하는 데 도움을 줄 수 있을 것으로 사료된다.