Distribution of the Scatter Ray in Fluoroscopy X-ray Room (투시 검사실 내 공간산란선 분포 측정)

  • Cho, Pyong-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.349-354
    • /
    • 2011
  • The results of the scattery distribution in the fluoroscopy X-ray room were as follows. When the measurement was done at the same height with the table, measured value was 0.78 mGy/min ~ 0.04 mGy/min (95%) within 50 cm and 250 cm. At 50 cm below the table, it was 0.17 mGy/min ~ 0.02mGy/min (86%) and at 50 cm above the table was 1.37 mGy/min ~ 0.05 mGy/min (96%), displaying a decrease. At the same time, the amount of rays were reduced in 50 ~ 60% at the same height with the table than the location 50 cm above the table, 90~95% of reduction rate was observed at 50 cm below the table. For the collimator, comparing to the case when it was completely open, the amount of ray was reduced from 0.78 mGy/min to 0.16 mGy/min at 50cm away and 0.04 mGy/min to 0.01 mGy/min at 250cm away thus approximately 80% on average was reduced when the collimator was reduced to 25%. Comparing with the case when there was a object on the table, the amount of scatter ray was reduced by 96.7% at every location when there is not a object on the table.

Comparison of Lung Ventilation Scan Using Technegas and $^{99m}Tc-DTPA$ Aerosol (Technegas 환기스캔과 $^{99m}Tc-DTPA$ Aerosol 스캔의 비교)

  • Choi, Yoon-Ho;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Keun-Youl;Koh, Chang-Soon;Koong, Sung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.237-243
    • /
    • 1990
  • Pulmonary embolism demands rapid and accurate diagnosis. And ventilation imaging has greatly improved the diagnostic accuracy of pulmonary embolism in addition to perfusion imaging. Agents currently used include xenon-133, krypton-81m and technetium-99m radioaerosols. However radioactive gases are compromised by availability and cost for krypton-81m, radiation dose, gamma energy and non?physiologic behaviour for xenon-133. Radioaerosols of technetium-99m componds are rapidly cleared from the lung after inhalation, and their relative low effeciency (specific radioactivity) and wide distribution of particle sizes make them also suboptimum. A new ventilation agent, Technegas is a suspension of structured graphite ellipsoids with diameter below 20nm, labelled with $^{99m}Tc$ in a carrier gas of Argon. This report describes the authors' clinical experience with Technegas. This is the first reported clinical study of this agent in Korea. A comparison of Technegas and $^{99m}Tc-DTPA$ aerosol was performed in 12 patients with various pulmonary diseases such as COPD, pulmonary tuberculosis and pleural effusion. All patients were studied with $^{99m}Tc-DTPA$ aerosol inhalation and Technegas ventilation. In both studies image quality was assessed (1) semiquantitatively by scoring bronchial and gastric activity, (2) subjectively by direct visual comparison of peripheral lung images and (3) quantitatively by computing the peripheral penetration index(PI) for each lungs. The bronchial activites were seen in 7 out of 12 cases with $^{99m}Tc-DTPA$ aerosol and in 5/12 with Technegas. The gastric activities were seen in 5/12 and 1/12 cases respectively. The average values of PI were 61.26% with $^{99m}Tc-DTPA$ aerosol and 69.20% with Technegas (p>0.05). Using $^{99m}Tc-DTPA$ aerosol, COPD patients showed deposition in the central airways with poor visualization of the peripheral areas of the lungs. In Technegas studies these phenomena were less prominent, and the examination is well tolerated by pateients and requires only a minimum of patient cooperation. With superiority of easy availability and handling, better physical characteristics and favorable Image quality, Technegas is a Promising agent for lung ventilation scanning.

  • PDF

The Role of Gamma Knife Radiosurgery for Prolactin Secreting Pituitary Adenomas (유즙 호르몬 과분비 선종에 대한 감마 나이프 수술의 역할)

  • Hur, Jin Woo;Lim, Young Jin;Leem, Won;Yang, Jae Young;Koh, Jun Seok;Kim, Tae Sung;Rhee, Bong Arm;Kim, Gook Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.3
    • /
    • pp.336-344
    • /
    • 2000
  • Objective : The treatment for prolactin secreting pituitary adenoma(prolactinoma) include pharmacology, surgery, radiation therapy or radiosurgery. The recent development of radiological imaging and microsurgery has made transsphenoidal microsurgery the treatment of choice for most prolactin secreting pituitary adenoma. Despite its low morbidity and mortality, relatively high recurrence and failure rate have been reported. Recent advances in neuroimaging provide a precise targeting in radiosurgery for treatment of prolactin secreting pituitary adenoma. In this regard, Gamma knife radiosurgery has been proposed as an alternative primary treatment modality or adjuvant therapy. Patients and Methods : Twenty three patients with prolactin secreting pituitary adenoma have been treated with Gamma knife radiosurgery in our institute from March 1992 to September 1998. We analyzed clinical, radiological and endocrinological changes in 21 patients who were followed up for an average of 35.7 months. Results : The mean age was 34.9 years and 16 patients were treated with Gamma knife radiosurgery as primary treatment and 5 patients underwent Gamma knife radiosurgery for residual tumors after microsurgery. The margin of the tumor was incorporated within the 40 to 80% and the mean marginal dose was 24.5 Gy. Clinical improvement in the last follow-up were present in 17 cases(81.0%) and 3 of 5 infertility patients became pregnant after Gamma knife radiosurgery. Tumor control rate after Gamma knife radiosurgery was 100%. Endocrinological normalization in the last follow-up were obtained in 12 cases(57.1%). In three cases, hormonal normalizations were present in early period(3-32 months) but serum hormone levels were elevated subsequently. Conclusion : We conclude that the Gamma knife radiosurgery for prolactin secreting pituitary adenoma seems to be safe and effective as adjuvant therapy after microsurgery and primary treatment modality in selective patients.

  • PDF

Calculation of Derived Investigation Levels for Uranium Intake (우라늄 섭취의 유도조사준위 산출)

  • Lee, Na-Rae;Han, Seung-Jae;Cho, Kun-Woo;Jeong, Kyu-Hwan;Lee, Dong-Myung
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.68-77
    • /
    • 2013
  • Derived Investigation levels(DILs) were calculated to protect the workers from the effects of both radiological hazard and chemical toxicity by uranium intake. Investigation Levels(ILs) of committed effective dose of 2 mSv $y^{-1}-6$ mSv $y^{-1}$ and uranium concentration of 0.3 ${\mu}g$ $g^{-1}$ in kidney, based on Korean Nuclaer Safety Act, Korean Occupational Safety and Health Act and current scientific studies of uranium intake were assumed. DILs of radiological hazard and chemical toxicity were then calculated based on the concentration of uranium in air of workplace, the lung monitoring and urine analysis, respectively. As a result, in case of the nuclear fuel fabrication plant where 3.5% enriched uranium is handled, derived investigation level(DIL) for the control of the concentration of uranium in the air of workplace assumed with 15-min acute inhalation was 0.6 mg $m^{-3}$ for all types of uranium. DILs for the control of the average concentration of uranium in air of workplace, assuming an 8-hour workday, were 15.21 ${\mu}g$ $m^{-3}$ of Type F uranium, 0.41-1.23 Bq $m^{-3}$ and 0.13-0.39 Bq $m^{-3}$ for Type M and Type S uranium, respectively. DILs for the lung monitoring assumed with a period of 6-month interval were 0.37-1.11 Bq and 0.39-1.17 Bq in acute and chronic inhalation for Type M, respectively and 0.30- 0.91 Bq and 0.19-0.57 Bq in acute and chronic inhalation for Type S, respectively. Since a detection limit of typical germanium detector for the measurement of 235U activity is 4 Bq, DILs calculated for the lung monitoring were not appropriate. DILs for urine analysis, for which an interval was assumed to be 1 month, were 14.57 ${\mu}g$ $L^{-1}$ based on chemical toxicity after acute inhalation. In addition, acute and chronic inhalation of Type M were calculated 2.85-8.58 ${\mu}g$ $L^{-1}$ and 1.09-3.27 ${\mu}g$ $L^{-1}$ based on the radiological hazard, respectively.

Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography (GATE 시뮬레이션을 사용한 알루미늄 부가필터 두께에 따른 Digital Radiography의 영상 화질 비교 평가)

  • Oh, Minju;Hong, Joo-Wan;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • In X-ray image, the role of filtration through the filter is to reduce the exposure of the patient by using photon which is useful in formation of the image, and at the same time, enhance the contrast of the image. During interaction between photon and object, low energy X-rays are absorbed from the site of a few cm of the first patient's tissue, and high energy X-rays are the one which form the image. Therefore, the radiation filter absorbs low energy X-ray in order to lower the exposure of the patient and improve the quality of the image. The purpose of this study is to compare the effect on the image quality by differences of added filter through simulation image and actual radiation image. For that purpose, we used Geant4 Application for Tomographic Emission (GATE) as a tool for Monte Carlo simulation. We set actual size, shape and material of Polymethylmethacrylate (PMMA) Phantom on GATE and differentiated the parameter of added filter. Also, we took image of PMMA phantom with same parameter of added filter by digital radiography (DR). Than we performed contrast-to-noise ratio (CNR) evaluation on both simulation image and actual DR image by Image J. Finally, we observed the effect on image quality due to different thickness of added filter, and compared two images' CNR evaluation's transitions of change. The result of this experiment showed decreasing in the progress of CNR on both DR and simulation image. It is ultimately caused by decreasing in contrast on image. In theory, contrast decrease with kVp increased. Given that condition, this study found out that filter makes not only decreasing total dose by absorbing low energy of X-ray, but also increasing average energy of X-ray.

Study on Optimized Dispensing of F-18 FDG Auto Dispenser (F-18 FDG 자동분주기의 분주 최적화에 관한 연구)

  • Ji, Bong-Geun;Lee, Sang-Hun;Kim, Jong-Eon;Kim, Won-Tae;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.377-384
    • /
    • 2016
  • This is a study on the optimized dispensing of the auto dispenser used for the purpose of reducing the exposure dose and accurate radiation dose of radioisotope with regard to the PET/CT practitioners. The research method was to find the optimized dispensing method through evaluating the results according to the syringe type, dispensing rate, and vial pressure and through the application of corrected values. As a result of this study, 9.38 mCi has been dispensed on average in the case of 5 ml syringe, and the reproducibility close to 10 mCi was shown at the dispense of 9.55 mCi in the case of 3 ml syringe. In the evaluation according to the dispensing rate, the quantity of radioisotope close to 10 mCi was dispensed at the rate of 5 mm/min when the measurement was carried out by increasing the rate by 5 mm/min units in the order of 5, 10, 15 and 20 mm/min. In the evaluation result according to the vial pressure before/after the use of Needle filter, it was measured to be 9.53 mCi before use and 9.84 mCi after use confirming that the dispensing after using Needle filter showed the optimal value. In addition, in the evaluation of radioactivity before/after the application of corrected values according to the increase in dispense frequency, it was measured 9.53 mCi before correction and 10.07 mCi after correction confirming that the value with correction applied was closer to the quantitative value. Thus, a good optimized method was confirmed to use a 3 ml syringe with dispensing rate of 5 mm/min, to use a Needle filter at dispensing, and to set the corrected value of [$y=0.097{\times}x$] according to the dispensing frequency of equipment.

Optimization of Hybrid Process of(Chemical Coagulation, Fenton Oxidation and Ceramic Membrane Filtration) for the Treatment of Reactive Dye Solutions (반응성 염료폐수 처리를 위한 화학응집, 펜톤산화, 세라믹 분리막 복합공정의 최적화)

  • Yang, Jeong-Mok;Park, Chul-Hwan;Lee, Byung-Hwan;Kim, Tak-Hyun;Lee, Jin-Won;Kim, Sang-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.257-264
    • /
    • 2006
  • This study investigated the effects of hybrid process(chemical coagulation, Fenton oxidation and ceramic UF(ultrafiltration)) on COD and color removals of commercial reactive dyestuffs. In the case of chemical coagulation, the optimal concentrations of $Fe^{3+}$ coagulant for COD and color removals of RB49(reactive blue 49) and RY84(reactive yellow 84) were determined according to the different coagulant dose at the optimal pH. They were 2.78 mM(pH 7) in RB49 and 1.85 mM(pH 6) in RY84, respectively. In the case of Fenton oxidation, the optimal concentrations of $Fe^{3+}\;and\;H_2O_2$ were obtained. Optimal $[Fe^{2+}]:[H_2O_2]$ molar ratio of COD and color removals of RB49 and RY84 were 4.41:5.73 mM and 1.15:0.81 mM, respectively. In the case of ceramic UF, the flux and rejection of supernatant after Fenton oxidation were investigated. After ceramic UF for 9 hr, the average flux of RB49 and RY84 solutions were $53.4L/m^2hr\;and\;67.4L/m^2hr$ at 1 bar, respectively. In addition, the permeate flux increased and the average flux recovery were 98.5-99.9%(RB49) and 91.0-97.3%(RY84) according to adopting off-line cleaning(5% $H_2SO_4$). Finally, COD and color removals were 91.6-95.7% and 99.8% by hybrid process, respectively.

REPORT OF EXPERIENCE WITH KIMURA'S DISEASE (기무라씨 질환, 5 예 보고)

  • Seel David J.;Park Yoon-Kyu;Lee Kwang-Min
    • Korean Journal of Head & Neck Oncology
    • /
    • v.5 no.1
    • /
    • pp.39-46
    • /
    • 1989
  • Kimura's Disease is a chronic inflammatory and proliferative condition producing subcutaneous masses especially in the head and neck area. This report of our experience with 5 patients with this disease is the first in the Korean surgical literature. Kimura's Disease is thought to be part of the larger spectrum of the entity known as angiolymphoid hyperplasia with eosinophilia (ALHE). It is characterized pathologically by hyperplastic lymphoid follicles, eosinophilic infiltration, and vase 비 ar proliferation. It produces masses which are most common in the area of the parotid, submandibular gland and upper neck. These masses occupy the subcutaneous tissues but also extend into salivary tissue and into upper neck nodes. One of our patients had masses in the groin. The tumors are extremely vascular due to the presence of new proliferative vessels and sinusoids. The average age of our 5 patients was 35, but all but one case were younger than 38 years of age. The male: female ratio was 3 : 2, and the average duration of symptoms was 5,2years. All patients had peripheral blood eosinophilia. All had multiple masses, sometimes symmetrical. The management was surgery alone in one case, surgery and steroids in one case, surgery and radiotherapy in two cases, and all three modalities in one case. The relationship of this entity to ALHE and our experience in the management of this disease are presented. A clinicopathological discrepancy alerted us to the existence of Kimura's Disease. A nineteen-year old male presented with subcutaneous masses over both mastoid areas present for 3 years (Case III). When biopsy on each side was reported as 'eosinophilic granuloma' we submitted the slides to an internationally expert pathologist. Symmetrically occurring tumors in the peri-parotid subcutaneous areas did not fit any category of neoplasm or granuloma known to us. The diagnosis, made by Dr. Gist Fan at the Ochsner Clinic, was Kimura's Disease. We found two additional cases in a review of soft tissue eosinophilic granuloma previously reported at Presbyterian Medical Center, and since then have diagnosed two new cases. These five cases constitute the basis for this, the largest series to be reported in Korea. These vascular, tumor-like lesions of the skin, subcutaneous areas and subjacent structures of the head and neck have been a variety of names, such as angiolymphoid hyperplasia with eosinophilia, eosinophilic hyperplastic lymphogranuloma, angioblastic lymphoid hyperplasia with eosinophilia, histioid hemangioma, and epithelioid hemangioma. The history of this disease spectrum dates back to 1937 when Kimm and Szeto (1) reported 7 cases of 'eosinophilic hyperplastic lymphogranuloma' in the Proceedings of the Chinese Medical Journal. In 1948 Kimura and his associates(2) reported additional cases in Japan under the title 'On the unusual granulation combined with hyperplastic changes of lymphatic tissue.' From then until 1966 several hundred cases were reported in China and Japan. The first report from the West was by Wells and Whimster(3) in the British Journal of Dermatology, in 1969. These authors coined the term, angiolymphoid hyperplasia with eosinophilia (ALHE). Since that time a debate has ensued as to whether Kimura's Disease and ALHE are distinct entities, or whether Kimura's is part of the larger spectrum of ALHE, perhaps a later or advanced phase. From the clinical perspective, surgeons should be aware of the diagnosis of Kimura's Disease not only as part of the differential diagnosis of head and neck tumors but also because these lesions are indolent, and generally require conservative surgical removal as part of the management program. CASE I. A 37-year-old female company employee presented in August 1982 with submental swelling of 12 years' duration and with inguinal swelling of 7 years' duration. The submental mass measured 5x5cm. and the inguinal mass was 8x4cm. in size. Peripheral eosinophilia varying from 14% to 40% was found. On August 20, 1982, the submental mass was removed and a superficial groin dissection was done. In May 1983 an intraoral lesion of the palate was removed. The patient is free of disease. CASE II. A 23-year-old unemployed man visited this hospital for the first time in July, 1984, with swelling of the right cheek present for 6 years. The mass was soft and ill-defined but measured 10x20cm. and extended from the submandibular upper neck to the zygomatic arch, and from the mastoid to the cheek, over the parotid gland. Eosinophilia varying from 27% to 29% was noted in the peripheral blood. On March 21, 1986, the lesion was resected. The procedure comprised an extended superficial parotidectomy from the temporalis fascia to the upper neck. Post-operatively radiotherapy 3000 rad tissue dose was administered using the 6 MeV linear accelerator. The patient remains free of disease. CASE III. A 19-year-old student came to the clinic with masses over both mastoid areas, present 3 years. On the right there were two adjacent lesions, one over the mastoid, the other in the upper jugular level of the neck. On the left it was a single mass over the mastoid. Eosinophilia varied from 13 to 32% in the peripheral blood, and 11.6% in the bone marrow. Incisional biopsy revealed 'eosinophilic granuloma' and a trial of predisolone was employed. The mass increased in size so a small dose of radiation (600 rads) was used, with substantial regression,. The lesion on the left was excised and follwed by 1000 rads radiotherapy. Finally recurrent tumor on the right side was removed on November 5, 1985. The patient remains free of disease. CASE N. A 29-year-old local merchant had had swelling of both upper necks since childhood. At the time of his first visit on March 17, 1986, the right submandibular mass measured 5x3.5cm. and the ,right upper neck and parotid tail mass measured 2.5cm. On the left there were masses in the upper neck, the largest of which measured 2.5cm, and of the parotid tail, 2.0cm. in size.(See Fig. 1) Peripheral eosinophilia of 39% was recorded. Left side partial parotidectomy and resection of the upper neck and subdigstric mases was done on May 2, 1986. The mass involving the right parotid tail and upper neck nodes was removed on Angust 7,1986. Postoperatively the patient was placed on prednisolone 30 mg. per day. No definite masses are palpable. CASE V. A 66-year-old housewife informed us, at the time of her first visit in May, 1986, that she had had multiple neck masses since 10 years ago. On the right side there was a 2.5cm. subcutaneous mass of the upper neck, over the upper jugular chain. On the left there was a 9x4.5cm. mass involving the entire parotid, the post-auricular area and the upper neck. A third mass presented in the submental area and measured 3.5cm. (See Fig. 2) Eosinophilia of 51% was noted in the peripheral blood. partial excision of the left upper neck lesion and complete excision of the submental mass were performed on june 6, 1986. post-operatively she was placed on 20 mg. of prednisolone daily, but when the mass re-grew after two months she was referred to Radiation Therapy for a 2500 rad course of treatment. A barely palpable thickening remains.

  • PDF

Measurement of the Mucosal Surface Distance in the Early Gastric Cancer Using CT Gastrography (조기 위암에서 CT Gastrography를 이용한 위점막 표면 거리 측정)

  • Choi, Hyang-Hee;Yu, Wan-Sik;Ryeom, Hun-Kyu;Lee, Jae-Hyuk;Choi, Jae-Jeong;Kim, Hee-Su;Cleary, Kevin;Mun, Seong-Ki;Chung, Ho-Young
    • Journal of Gastric Cancer
    • /
    • v.6 no.3
    • /
    • pp.161-166
    • /
    • 2006
  • Purpose: Recently, the incidence of early gastric cancer (EGC) patients is rapidly increased in Korea. However, they're often not perceptible by surgical palpation or inspection. The aim of this study is 1) to develope a software that can locate the tumor and measure the mucosal distance from an anatomic landmark to the tumor using CT gastrography and 2) to compare the distance measured by the developed software with the distance measured by the pathologic findings. Materials and Methods: Between January 2004 and September 2005, sixty patients (male=45, female=15, mean 57.8 years old) estimated for EGC with preoperative CT scans and undergone gastrectomies in Kyungpook National University Hospital were enrolled in this study. Preoperative CT scans were performed after insufflations of room air via 5 Fr NG tube. The scans included the following parameters: (slice thickness/reconstruction interval: 0.625 mm, kVp: 120, mAs: 200). 3D volume rendering and measurement of the surface distance from the pylorus to the EGC were performed using the developed software. Results: The average difference between the lesion to pylorus distances measured from pathologic specimens and CT gastrography was $5.3{\pm}2.9\;mm(range,\;0{\sim}23\;mm)$. The lesion to pylorus distance measured from CT gastrography was well correlated with that measured from the pathologic specimens (r=0.9843, P<0.001). Conclusion: These results suggest that the surface distance from an anatomic landmark to the EGC can be measured accurately by CT gastrography. This technique could be used for preoperative localization of early gastric carcinomas to determine the optimal extent of surgical resection.

  • PDF

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF