• Title/Summary/Keyword: average radiation dose

Search Result 600, Processing Time 0.033 seconds

Evaluation of the Fetal Dose during Prophylactic Placement of Internal Iliac Artery Balloon Occlusion Catheters in Placenta Accreta (유착태반환자의 예방적 내장골동맥 풍선카테터 설치술 시행 시 태아선량 평가)

  • Kim, Dong-Sik;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.313-321
    • /
    • 2016
  • Placenta accrete patients whose mother mortality rates are rather high due to massive bleeding during childbirth need to have Prophylactic placement of Internal Iliac Artery Balloon Occlusion Catheters procedure to reduce amount of blood loss and inoperative transfusion. Nevertheless, studies for mothers inevitably exposed to dose during PIIABOCs procedure have not been published many yet. Therefore, this study is to investigate exact information on radiation dose exposed to fetus during PIIABOCs procedure. Average effective dose of fetus per organ is 2.38~8.83 mGy, measured highest at beam center and followed by eyeball, stomach and bladder. The result showed that the longer fluoroscopy time is used, the closer beam center is and the thicker abdominal thickness is, the more effective dose on fetus is increasing. When using the collimator and protection shown to decrease the effective dose and when using higher the patient table shown to decrease the effective dose. It has been reported that the threshold of deterministic effect is about 100mGy. Deterministic effect was regarded as a factor that would influence on fetus exposed by medical radiation than stochastic effect. Consequently, it concluded that dose exposed on fetus in PIIABOCs procedure was approximately 10% of threshold of deterministic effect with effective dose of 0.49~18.27 mGy.

HEALTH RISK ASSESSMENT OF HOUSEHOLD EXPOSURE TO INDOOR RADON IN ASSOCIATION WITH THE DWELLING'S AGE

  • Shahrokhi, Amin;Shokraee, Forough;Reza, Ali;Rahimi, Hasn
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.155-161
    • /
    • 2015
  • Radon is a naturally occurring radioactive gas and a major indoor contribution of exposure to ionizing radiation in dwellings. $^{222}Rn$ is a health hazard gas what is responsible for thousand lung cancer deaths every year. In this study, indoor radon concentrations present in thirty representative houses in Mahallat city, Iran, were determined in order to estimate lung cancer risk associated with residential radon exposure. Long-term passive method, using CR-39, was used to measure the radon concentration. The results showed an association between the age of the dwellings and the indoor radon concentration that was found, in that the concentration of radon tended to increase as the age of the dwelling also increased. The indoor radon concentrations were calculated to be within the range of $23{\pm}2$ to $350{\pm}26Bq{\cdot}m^{-3}$, with an average of $158Bq{\cdot}m^{-3}$. The annual effective dose from inhaled radon and its decay products was calculated between $0.8{\pm}0.1$ and $12.3{\pm}0.9mSv{\cdot}y^{-1}$, with an average of $5.5mSv{\cdot}y^{-1}$. By taking into consideration the EPA recommendation and ICRP statement, the average annual risk of lung cancer from inhaled radon was calculated as 0.09%, 0.06%, 0.01%, and 0.03% for current smokers (CS), those who had ever smoked (ES), never smokers (NS) and the general population, respectively.

A Study on the Reduction of Patient's Exposure Dose according to the Arrival Time of Contrast Media in Abdominal CT Scan using Bolus Tracking Technique (Bolus tracking 기법을 이용한 복부 CT 검사 시 조영제 도달시간에 따른 환자 피폭선량 감소에 관한 연구)

  • Lee, Seung yong;Han, Dong kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • The purpose of this study is to find out the factors that affect the patient's exposure dose during the abdominal CT scan using the bolus tracking technique, and reducing the radiation exposure to the patient during the abdominal CT scan using the bolus tracking technique by adjusting the delay time according to the corresponding factor. The experiment was divided into two parts, and the first experiment was conducted with 300 patients There were 188 males and 112 females, and their average age was 58±12.18(19~85). In the second experiment, 150 subjects (100 males and 50 females) who were undergoing their follow-up examination among the first experiment subjects, and the difference in dose before and after was compared by applying the delay time according to the influencing factor. As a result of the first experiment, there was a relationship between the arrival time of the contrast media and the heart rate, and it was found that the arrival time decreased as the heart rate increased for both men and women. As a result of the second experiment, the average dose of CTDIvol and DLP before/after applying the delay time according to the heart rate decreased 4.98 mGy and 5.33 mGy·cm in the male group, and 3.54 mGy and 3.88 mGy·cm in the female group. By applying proper delay time according to the patient's heart rate during abdominal CT scan with the bolus tracking technique, the radiation exposure dose of the patient can be reduced.

Radiation Exposure Dose on Persons Engaged in Radiation-related Industries in Korea (한국에서 방사선 관련 종사자들의 개인피폭선량 실태에 관한 연구)

  • Lim, Bong-Sik
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.185-195
    • /
    • 2006
  • Purpose: This study investigated the status of radiation exposure doses since the establishment of the "Regulations on Safety Management of Diagnostic Radiation Generation Device" in January 6, 1995. Method: The level of radiation exposure in people engaged or having been engaged in radiation-related industries of inspection organizations, educational organizations, military units, hospitals, public health centers, businesses, research organizations or clinics over a 5 year period from Jan. 1, 2000 to Dec. 31, 2004 was measured. The 149,205 measurement data of 57,136 workers registered in a measurement organization were analysed in this study. Frequency analysis, a Chi-square test, Chi-square trend test, and ANOVA was used for data analysis. Results: Among 57,136, men were 40,870(71.5%). 50.3% of them were radiologic technologists, otherwise medical doctors(22.7%), nurse(2.9%) and others(24.1%). The average of depth radiation and surface radiation during the 5-year period were found to decrease each year. Both the depth radiation and surface radiation exposure were significantly higher in males, in older age groups, in radiological technologists of occupation. The departments of nuclear medicine had the highest exposure of both depth and surface radiation of the divisions of labor. There were 1.98 and 2.57 per 1,000 person-year were exposed more than 20 mSv(limit recommended by International Commission on Radiological Protection) in depth and surface radiation consequently. Conclusion: The total exposure per worker was siginifcantly decreased by year. But Careful awareness is needed for the workers who exposed over 20 mSv per year. In order to minimize exposure to radiation, each person engaged in a radiation-related industry must adhere to the individual safety management guidelines more thoroughly. In addition, systematic education and continuous guidance aimed at increasing the awareness of safety must be provided.

  • PDF

Radiation Treatment Planning Evaluation by Internal Target Volume Settings (내부표적체적 설정을 통한 방사선치료계획 평가)

  • Park, Ho-Chun;Han, Jae-Bok;Choi, Nam-Gil
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.8
    • /
    • pp.416-423
    • /
    • 2015
  • The study was conducted targeting 25 patients who underwent the respiratory gated radiation therapy in the abdominal region at Radiation Oncology of a University Hospital from December 2013 to June 2014 and types of cancer included liver(64%), CBD(8%), gastric(8%), GB(8%), pancreas(8%), SMA(4%). The means of ITV and PTV volume are 471.44 cm3 and 425.48 cm3, showing an increase in volume. Normal tissue volume was also found to have increased due to the increase of the section selected from PTV section to ITV section. Right kidney showed a significant increase in differences between increase in normal tissue volume, increase in target volume and increase in therapy irradiation area and difference between the means of dose applied to normal tissue. There was no significant difference in the mean dose applied to normal tissue according to the respiratory average. Both kidneys showed a significant difference in the difference between mean doses of target moving and normal tissue. In this study, both therapy methods through PTV section and ITV section volume setting were appropriate for protection doses of normal tissue and distributed over 95% of the prescribed dose and therefore, it is considered to be okay to be optionally used depending on the patient's therapeutic purpose. But in order to minimize the unexpected side effect, the plan of PTV section and ITV section should be established and used by evaluating normal tissue protection dose.

Clinical Application of Gamma Knife Dose Verification Method in Multiple Brain Tumors : Modified Variable Ellipsoid Modeling Technique

  • Hur, Beong Ik;Lee, Jae Min;Cho, Won Ho;Kang, Dong Wan;Kim, Choong Rak;Choi, Byung Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.2
    • /
    • pp.102-107
    • /
    • 2013
  • Objective : The Leksell Gamma Knife$^{(R)}$ (LGK) is based on a single-fraction high dose treatment strategy. Therefore, independent verification of the Leksell GammaPlan$^{(R)}$ (LGP) is important for ensuring patient safety and minimizing the risk of treatment errors. Although several verification techniques have been previously developed and reported, no method has ever been tested statistically on multiple LGK target treatments. The purpose of this study was to perform and to evaluate the accuracy of a verification method (modified variable ellipsoid modeling technique, MVEMT) for multiple target treatments. Methods : A total of 500 locations in 10 consecutive patients with multiple brain tumor targets were included in this study. We compared the data from an LGP planning system and MVEMT in terms of dose at random points, maximal dose points, and target volumes. All data was analyzed by t-test and the Bland-Altman plot, which are statistical methods used to compare two different measurement techniques. Results : No statistical difference in dose at the 500 random points was observed between LGP and MVEMT. Differences in maximal dose ranged from -2.4% to 6.1%. An average distance of 1.6 mm between the maximal dose points was observed when comparing the two methods. Conclusion : Statistical analyses demonstrated that MVEMT was in excellent agreement with LGP when planning for radiosurgery involving multiple target treatments. MVEMT is a useful, independent tool for planning multiple target treatment that provides statistically identical data to that produced by LGP. Findings from the present study indicate that MVEMT can be used as a reference dose verification system for multiple tumors.

Comparison and Analysis of Photon Beam Data for Hospitals in Korea and Data for Quality Assurance of Treatment Planning System (국내 의료기관들의 광자 빔 데이터의 비교 분석 및 치료계획 시스템 정도관리자료)

  • Lee, Re-Na;Cho, Byung-Chul;Kang, Sei-Kwon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.179-186
    • /
    • 2006
  • Purpose: Photon beam data of linear accelerators in Korea are collected, analyzed, and a simple method for checking and verifying the dose calculations in a TPS are suggested. Materials and Methods: Photon beam data such as output calibration condition, output factor, wedge factor, percent depth dose, beam profile, and beam quality were collected from 26 institutions in Korea. In order to verify the accuracy of dose calculation, ten sample planning tests were peformed. These Include square, elongated, and blocked fields, wedge fields, off-axis dose calculation, SSD variation. The planned data were compared to that of manual calculations. Results: The average and standard deviation of photon beam quality for 6, 10, and 15 MV were $0.576{\pm}0.005,\;0.632{\pm}0.004,\;and\;0.647{\pm}0.006$, respectively. The output factors of 6 MV photon beam measured at depth of dose maximum for $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.944{\pm}0.006,\;1.031{\pm}0.006,\;and\;1.055{\pm}0.007$. For 10 MV photon beam, the values were $0.935{\pm}0.006,\;1.031{\pm}0.007,\;1.054{\pm}0.0005$. The collected data were not enough to calculate average, the output factors for 15MV photon beam with field size of $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.941{\pm}0.008,\;1.032{\pm}0.004,\;1.049{\pm}0.014$. There was seven institutions $e{\times}ceeding$ tolerance when monitor unit values calculated from treatment planning system and manually were compared. The measured average MU values for the machines calibrated at SAD setup were 3 MU and 5 MU higher than the machines calibrated at SSD for 6 MV and 10 MV, respectively except the wedge case. When the wedges were inserted, the MU values to deliver 100 cGy to 5 cm depends on manufactures. When the same wedge angle was used, Siemens machine requires more MUs then Varian machine. Conclusion: In this study, photon beam data are collected and analyzed to provide a baseline value for chocking beam data and the accuracy of dose calculation for a treatment planning system.

  • PDF

Evaluation of Clinical Application Model of Optimized Parameter through Analysis of Stability of Radiation Output and Image Quality when Exposure Time Change of Digital Radiography (DR) (디지털 방사선 시스템(DR)의 조사시간 변화 시 방사선 출력과 영상 화질의 안정성 분석을 통한 최적화된 파라미터의 임상 적용 모델 평가)

  • Hwang, Jun-Ho;Choi, Ji-An;Kim, Hyun-Soo;Lee, Kyung-Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.139-148
    • /
    • 2020
  • The purpose of this study is to propose a method to optimize the performance of Digital Radiography (DR) by analyzing the effect of exposure time change on the stability of radiation output and image quality. The experimental method was used to change the exposure time to 50 msec, 100 msec, 200 msec, and 400 msec so that the Percentage Average Error (PAE), Time-to-Radiation Dose Curve, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR) and theses analysis were performed to evaluate the normal operation of parameters, radiation output and image quality. As a result, all the parameters used in the experiment showed the Percentage Average Error in the normal range, and the shorter the exposure time, the stability of radiation output and image quality decrease. In conclusion, it was found that the performance of Digital Radiography can be optimized when stable radiation output and image quality are applied by applying 100 msec ~ 200 msec exposure time.

A Comparison between Portal Dosimetry and Mobius3D Results for Patient-Specific Quality Assurance in Radiotherapy

  • Kim, Sung Yeop;Park, Jaehyeon;Park, Jae Won;Yea, Ji Woon;Oh, Se An
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.107-115
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the clinical quality assurance results of portal dosimetry using an electronic portal imaging device, a method that is extensively used for patient-specific quality assurance, and the newly released Mobius3D for intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Methods: This retrospective study includes data from 122 patients who underwent IMRT and VMAT on the Novalis Tx and VitalBeam linear accelerators between April and June 2020. We used a paired t-test to compare portal dosimetry using an electronic portal imaging device and the average gamma passing rates of MobiusFX using log files regenerated after patient treatment. Results: The average gamma passing rates of portal dosimetry (3%/3 mm) and MobiusFX (5%/3 mm) were 99.43%±1.02% and 99.32%±1.87% in VitalBeam and 97.53%±3.34% and 96.45%±13.94% in Novalis Tx, respectively. Comparison of the gamma passing rate results of portal dosimetry (3%/3 mm) and MobiusFX (5%/3 mm as per the manufacturer's manual) does not show any statistically significant difference. Conclusions: Log file-based patient-specific quality assurance, including independent dose calculation, can be appropriately used in clinical practice as a second-check dosimetry, and it is considered comparable with primary quality assurance such as portal dosimetry.

Effects of Postoperative Radiation Therapy for Prevention of Keloids and Hypertrophic Scars (켈로이드와 비후성 반혼에서 재발을 방지하기 위한 수술후 방사선치료의 효과)

  • Kang, Ki-Mun;Choi, Ihl-Bohng;Kim, In-Ah;Jang, Jee-Young;Shinn, Kyung-Sub
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.269-276
    • /
    • 1997
  • Purpose : To evaluate the effects of surgical excision followed by radiation therapy for Prevention of keloids and hypertrophic scars. Materials and Methods : From October 1987 to April 1995, radiation therapy was applied to 167 sites in 106 patients with surgical excision in an attempt to prevention of recurrence against keloids and hypertrophic scars. The main etiology of the keloids and hypertrophic scars were surgery in $49.2\%,\;trauma\;in\;25.0\%,\;ear-piercing\;in\;5.4\%,\;and\;burn\;in\;5.4\%$, The Patients' ages ranged from 3 to 70 years with a median of 32 years. Radiation therapy used ranged from 6 to 8MeV electron beam. Radiation therapy was delivered within 24 hours of surgical excision. Several dose schedules were used, varing from 400cGy in 1 daily fraction to 1900cGy in 4 daily fractions. The average total dose was 1059cGy, and the average dose per fraction was 433cGy. All patients were followed up from 24 to 114 months with a median follow up of 49 months. Results : The overall recurrence rate was $12.6\%$ (21/167) The overall 1-year and 2-year recurrence rates were $10.2\%\;and\;11.4\%$, respectively Among 21 recurrent sites, seventeen sites $(81\%)$ were confirmed within 12 months after surgical excision. Period to recurrence ranged from 1 month to 47 months with a median recurrence time of 9.6 months, The history of previous therapy was only a significant factor in recurrence. Twenty-four patients had history of previous therapy recurrence rates was significantly higher in this group than those without history of Previous therapy $(22.6\%\;vs.\;11.0\%,\;p=0.04)$. There was no serious complication related to radiation therapy. Conclusion : This study suggests that surgical excision followed by radiation therapy is an effective method of preventing keloids and hypertrophic scars.

  • PDF