• Title/Summary/Keyword: average error

Search Result 2,635, Processing Time 0.028 seconds

AN ERROR OF SIMPONS'S QUADRATURE IN THE AVERAGE CASE SETTING

  • Park, Sung-Hee;Hong, Bum-Il
    • Journal of the Korean Mathematical Society
    • /
    • v.33 no.2
    • /
    • pp.235-247
    • /
    • 1996
  • Many numerical computations in science and engineering can only be solved approximately since the available infomation is partial. For instance, for problems defined ona space of functions, information about f is typically provided by few function values, $N(f) = [f(x_1), f(x_2), \ldots, f(x_n)]$. Knwing N(f), the solution is approximated by a numerical method. The error between the true and the approximate solutions can be reduced by acquiring more information. However, this increases the cost. Hence there is a trade-off between the error and the cost.

  • PDF

Design and Implementation of a Distance Measurement System using Radar Sensor (레이더 센서를 이용한 거리 측정 시스템의 설계 및 구현)

  • Jang, Si-woong;Jung, Dong-hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.7
    • /
    • pp.1009-1014
    • /
    • 2018
  • In this paper, we have designed and implemented a system that utilizes a radar sensor to measure distance between a sensor and objects. The sensor module creates raw data and uploads the data on the distance measuring system, which detects the presence of objects by using standard deviation and average filters. The experiment found that an algorithm using average filters measured people with error rates of up to 9.7 meters and a maximum error rate of 0.02 meters or less. While in an algorithm using standard deviations, it was found that an object is measured at an error rate of up to a maximum distance of 9.7 meters and a maximum error rate of 0.15 meters. Therefore, we have concluded that if a distance was measured by using a radar sensor, algorithms using average filters resulted in a higher accuracy than standard deviations filters.

SDR Based Modulation Performance of RF Signal under Different Communication Channel

  • Shabana Habib
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.3
    • /
    • pp.182-188
    • /
    • 2024
  • Hardware components are an integral part of Hardware Define Radio (HDR) for seamless operations and optimal performance. On the other hand, Software Define Radio (SDR) is a program that does not rely on any hardware components for its performance. Both of the latter radio programmers utilize modulation functions to make their core components from signal processing viewpoint. The following paper concentrates on SDR based modulation and their performance under different modulations. The bit error rate (BER) of modulations such as PSK, QAM, and PSAM were used as indicators to test channel quality estimation in planar Rayleigh fading. Though it is not commonly used for channel fading, the method of the adder determines the regionally segmented channel fading. Thus, the estimation error of the channel change substantially reduces the performance of the signal, hence, proving to be an effective option. Moreover, this paper also elaborates that BER is calculated as a function of the sample size (signal length) with an average of 20 decibels. Consequently, the size of the results for different modulation schemes has been explored. The analytical results through derivations have been verified through computer simulation. The results focused on parameters of amplitude estimation error for 1dB reduction in the average signal-to-noise ratio, while the combined amplitude deviation estimation error results are obtained for a 3.5 dB reduction

Point Recognition Precision Test of 3D Automatic Face Recognition Apparatus(3D-AFRA) (3차원 안면자동인식기(3D-AFRA)의 안면 표준점 인식 정확도 검증)

  • Seok, Jae-Hwa;Cho, Kyung-Rae;Cho, Yong-Beum;Yoo, Jung-Hee;Kwak, Chang-Kyu;Hwang, Min-U;Kho, Byung-Hee;Kim, Jong-Won;Kim, Kyu-Kon;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.1
    • /
    • pp.50-59
    • /
    • 2007
  • 1. Objectives The Face is an important standard for the classification of Sasang Contitutions. Now We are developing 3D Automatic Face Recognition Apparatus to analyse the facial characteristics. This apparatus show us 3D image of man's face and measure facial figure. We should examine accuracy of position recognition in 3D Automatic Face Recognition Apparatus(3D-AFRA). 2. Methods We took a photograph of Face status with Land Mark by using 3D-AFRA. And We scanned Face status by using laser scanner(vivid 700). We analysed error average of distance between Facial Definition Points. We compare the average between using 3D-AFRA and using laser scanner. So We examined the accuracy of position recognition in 3D-AFRA at indirectly. 3. Results and Conclusions The error average of distance between Right Pupil and The Other Facial Definition Points is 0.5140mm and the error average of distance between Left Pupil and The Other Facial Definition Points is 0.5949mm in frontal image of face. The error average of distance between Left Pupil and The Other Facial Definition Points is 0.5308mm and the error average of distance between Left Tragion and The Other Facial Definition Points is 0.6529mm in laterall image of face. In conclusion, We assessed that accuracy of position recognition in 3D-AFRA is considerably good.

  • PDF

Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife (로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가)

  • Jeong, Young-Joon;Jung, Jae-Hong;Lim, Kwang-Chae;Cho, Eun-Ju
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: The purpose is to evaluate the accuracy of correcting the targeting error through the Target Location System (TLS) for the location change error of the reference point which arises from the movement or motion of patient during the treatment using the CyberKnife. Materials and Methods: In this test, Gafchromic MD-55 film was inserted into the head and neck phantom to analyze the accuracy of the targeting, and then the 6 MV X-ray of CyberKnife (CyberKnife Robotic Radiosurgery System G4, Accuray, US) was irradiated. End to End (E2E) program was used to analyze the accuracy of targeting, which is provided by Accuray Corporation. To compute the error of the targeting, the test was carried out with the films that were irradiated 12 times by maintaining the distance within the rage of $0{\pm}0.2\;mm$ toward x, y, z from the reference point and maintaining the angle within the rage of $0{\pm}0.2^{\circ}$ toward roll, pitch, yaw, and then with the films which were irradiated 6 times by applying intentional movement. And the correlation in the average value of the reference film and the test film were analyzed through independent samples t-test. In addition, the consistency of dose distribution through gamma-index method (dose difference: 3%) was quantified, compared, and analyzed by varying the distance to agreement (DTA) to 1 mm, 1.5 mm, 2 mm, respectively. Results: E2E test result indicated that the average error of the reference film was 0.405 mm and the standard deviation was 0.069 mm. The average error of the test film was 0.413 mm with the standard deviation of 0.121 mm. The result of independent sampling t-test for both averages showed that the significant probability was P=0.836 (confidence level: 95%). Besides, by comparing the consistency of dose distribution of DTA through 1 mm, 1.5 mm, 2 mm, it was found that the average dose distribution of axial film was 95.04%, 97.56%, 98.13%, respectively in 3,314 locations of the reference film, consistent with the average dose distribution of sagittal film that was 95.47%, 97.68%, 98.47%, respectively. By comparing with the test film, it was found that the average dose distribution of axial film was 96.38%, 97.57%, 98.04%, respectively, at 3,323 locations, consistent with the average dose distribution of sagittal film which was 95.50%, 97.87%, 98.36%, respectively. Conclusion: Robotic CyberKnife traces and complements in real time the error in the location change of the reference point caused by the motion or movement of patient during the treatment and provides the accuracy with the consistency of over 95% dose distribution and the targeting error below 1 mm.

  • PDF

Sampling Error of Areal Average Rainfall due to Radar Partial Coverage (부분적 레이더 정보에 따른 면적평균강우의 관측오차)

  • Yoo, Chul-Sang;Ha, Eun-Ho;Kim, Byoung-Soo;Kim, Kyoung-Jun;Choi, Jeong-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.5
    • /
    • pp.545-558
    • /
    • 2008
  • This study estimated the error involved in the areal average rainfall derived from incomplete radar information due to radar partial coverage of a basin or sub-basin. This study considers the Han-River Basin as an application example for the rainfall observation using the Ganghwa rain radar. Among the total of 20 mid-sized sub-basins of the Han-River Basin evaluated in this study, only five sub-basins are fully covered by the radar and three are totally uncovered. Remaining 12 sub-basins are partially covered by the radar to result in incomplete radar information available. When only partial radar information is available, the sampling error decreases proportional to the size of the radar coverage, which also varies depending on the number of clusters. Conditioned that the total area coverage remains the same, the sampling error decreases as the number of clusters increases. This study estimated the sampling error of the areal average rainfall of partially-covered mid-sized sub-basins of the Han- River Basin, and the results show that the sampling error could be at least several % to maximum tens % depending on the relative coverage area.

Error Rate Enhancement Algorithm for 13.56 MHz Impedance Automatic Matching System (13.56 MHz 임피던스 자동 정합 시스템을 위한 임피던스 에러율 향상 알고리즘)

  • Jang, Kwang-Ho;Park, Su-Yeon;Choi, Jin-Joo;Lee, Dong-Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.7
    • /
    • pp.484-490
    • /
    • 2018
  • This paper describes an algorithm for calculating load impedance by measuring voltage and current components using a VI sensor in a 13.56 MHz impedance automatic matching system. We propose an algorithm that improves the error rate by using an arbitrary complex calibration load instead of the conventional $50{\Omega}$ calibration load. The error rate is targeted to attain average values of $R_{IN}$ and $X_{IN}$ at 1% and 20% or less, respectively. First, the IF frequency is calculated using a mixer to reduce the error rate. Second, when the arbitrary complex load is used as the calibration load, the error rate $R_{IN}$ decreased from 4.7 % to 0.3 % on average, and $X_{IN}$ decreased from 102 % to 18.3 % on average.

Determination of Transferring Period of Several Plants using Image Processing (영상처리를 이용한 작물의 모종시기 결정)

  • 민병로;김웅;김동우;이대원
    • Journal of Bio-Environment Control
    • /
    • v.13 no.3
    • /
    • pp.178-184
    • /
    • 2004
  • This study carried out to develope the vision system which automatically finds out a optimum transferring period of plants (Perilla, Platycodon grandifloums and Lactuca sativa) by using image process-ing. This system mearsured a height, long diameter and short diameter of the three plants with 20 replications. Following results were obtained on each plant. Compared with real data to be measured by hand with the vernier calipers, height, long diameter and short diameter of Perilla showed 0.5 mm average error rate with 1.7%, 4.7 mm average error rate with 3.9% and 5.5 mm average error rate with 6.9% respectively. Those of Platycodon grandifloums showed 2.4 mm with 8.1%, 3.4 mm with 7.2% and 4.0 mm with 10.4% respectively. Those of Lactuca sativa showed 4.0 mm with 9.1 %,3.4 mm with 7.2% and 3.6 mm with 9.4% respectively. The system could be used to transfer accurately the plant seedling, if the system were improved enough to reduce error rate for the optimum transferring period of a plant in the greenhouse.

Edge Enganced Error Diffusion using an Adaptive Threshold Modulation (적응형 임계값 변조를 이용한 경계강조 오차확산법)

  • Gang, Tae-Ha;Hwang, Byeong-Won
    • The KIPS Transactions:PartB
    • /
    • v.8B no.3
    • /
    • pp.319-326
    • /
    • 2001
  • 오차확산법은 중간조 처리에서 우수한 영상의 재현능력을 갖는 기법이다. 그러나 이의 기법은 경계재현 능력이 미약하며, 주기적인 패턴이 발생하여 영상의 화질을 저하시키는 단점이 있다. 본 논문에서는 경계재현의 능력을 개선하기 위한 경계강조법과 주기적인 패턴 발생을 감소시키기 위한 적응형 임계값 변조를 적용하는 방법을 제안하였다. 경계강조를 위한 임계값을 변조는 원영상의 공간적 기울기 정보를 활용하여 수행하였고, 동시에 기울기 정보를 이용하여 청색잡음 마스크를 적응적으로 적용하는 임계값 변조로 주기적인 패턴의 발생을 감소시키도록 하였다. 적응형 임계값 변조를 적용한 실험에서 영상의 주기적인 패턴이 감소된 보다 선명한 경계강조의 중간조 영상을 얻을 수 있었으며, 객관적인 특성분석을 위한 표시오차의 RAPSD, 거리에 따른 경계상관도 및 로컬 평균 일치도의 분석에서 제안한 기법이 효율적임을 확인하였다.

  • PDF

BER Analysis of Coherent Free-Space Optical Systems with Pulsed Noise Jamming (코히런트 무선 광통신 시스템에서 펄스 재밍으로 인한 비트오류율 분석)

  • Park, Hwi-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.3
    • /
    • pp.304-306
    • /
    • 2016
  • In this letter, we investigate the performance of coherent free-space optical(FSO) systems under pulsed noise jamming conditions. In particular, we derive the average bit error probability of the coherent FSO systems with the pulsed noise jamming in a closed-form. Also, we derive the optimal fraction of symbol time of the jammer. We confirm the derived average error probability expressions by the exactly matching Monte-Carlo simulation results.